01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 September 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for a drydock examination no later than 31AUG2022. Vessel is prohibited from carrying passengers or cargo and prohibited from departure from port until a successful drydock and internal structural examination has been completed.
Vessel is directed to contact the cognizant OCMI if needed to depart port to proceed to drydocking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Vessel did not have current charts on board. Provide current charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 26 April 2022
Resolution: Vessel provided updated electronic charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2022
Resolved
A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The bilge foot and strainer in the #2 compartment was found disconnected. Repair bilge foot/strainer.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 29 April 2022
Resolution: Vessel cleaned and reattached bilge foot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2022
Resolved
Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions. The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The port fuel vent bell was found wasted in way of the flame screen support.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 29 April 2022
Resolution: Vessel received new fuel vent assembly and installed it.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 April 2022
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include - (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Vessel was found with the sewage overboard discharge valve from the MSD tank located in the #2 compartment in the open position. Close and secure the valve using one of the listed methods.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 26 April 2022
Resolution: Vessel chained and locked valve.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 March 2021
Resolved
General alarm and public address systems not operable in bunk room. Demonstrate proper operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel demonstrated operation of GA and PA systems.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Port ring lifebuoy deteriorated. Replace life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel replaced lifebuoy.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021
Resolved
Ground fault indicators not operable. Demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel replaced burnt out bulbs and demonstrated operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021
Resolved
Hertz meter at switchboard not operable. Demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel has hertz readout at pilot station.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 March 2021
Resolved
Vessel does not have DSC VHF radio programmed with MMSI and with GPS input. Provide properly configured DSC VHF radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel attached DSC VHF radios to GPS and demonstrated to attending USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2020
Resolved
Demonstrate proper operation of pressure vessel safety relief valve.
Action required: 10 - Deficiency Rectified
Due 4 February 2020
Resolved 4 February 2020
Resolution: Vessel replaced inoperable relief valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2020
Resolved
Replace broken port MDE expansion tank sight glass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 10 February 2020
Resolution: Vessel replaced sight glass.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 February 2020
Resolved
Provide metallic cable supports every 24" for electrical cables in salon/galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 10 February 2020
Resolution: Vessel provided metal wire hangers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2020
Resolved
Demonstrate proper operation of remote fuel shut off at port generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 10 February 2020
Resolution: Vessel shortened cable and ensured function as well as correcting chafing issue.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020
Resolved
Provide non-conductive mat at switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 10 February 2020
Resolution: Vessel provided rubber matting.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 February 2020
Resolved
Provide current MMSI programmed in to VHF DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 10 February 2020
Resolution: Vessel programmed correct MMSI in to radio.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 10 October 2019
Resolved
Complete a CIC in-service inspection prior to carrying passemgers overnight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Conducted CIC.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 October 2019
Resolved
Replace forward smoke detector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2019
Resolved 16 December 2019
Resolution: Smoke detector provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019
Resolved
Provide a handle and foot steps for emergency egress.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2020
Resolved 6 January 2020
Resolution: Handle and foot steps provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2019
Resolved
Replace 09 mattresses.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 February 2020
Resolution: Vessel elected to remove non-compliant mattresses and reduce overnight accomodations to 10.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019
Resolved
Cap off dead end wiring in E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2019
Resolution: Wires capped off.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019
Resolved
Mount light fixture in E/R port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2019
Resolution: Fixture is mounted.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 May 2019
Resolved
Dewater aft ballast tank IAW stability booklet.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 June 2019
Resolution: Water removed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2019
Resolved
Repair pull cable for stbd remote fuel shut-off valve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 June 2019
Resolution: Pull cables replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2019
Resolved
Provide 02 additional B-II extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2019
Resolution: Fire extinguishers provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 May 2019
Resolved
Provide life raft service certificate by 31MAY19.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 12 June 2019
Resolution: Life raft certificate provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2019
Resolved
Replace and register new EPIRB due to failed test; vessel restricted to 3nm from shore.
Action required: 705 - Other - as specified
Resolved 12 June 2019
Resolution: Epirb replaced and registered with NOAA.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2019
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: First aid kit updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 May 2019
Resolved
Renew FCC Safety Certificate and FCC Station License.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2019
Resolution: FCC Safety Certificate and FCC Station License renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2019
Resolved
Replace fwd lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2019
Resolution: Life ring replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2019
Resolved
Properly mark port fuel shutoff valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: Valves labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 May 2019
Resolved
Replace all deck hatch gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: Gaskets replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2019
Resolved
Provide lock nuts on steering ram mounting bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: Locking nuts installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2019
Resolved
Clean/remove oil soaked rags in E/R.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: rags removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2019
Resolved
Repair minor fuel leak at union on return line to fuel tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2019
Resolved 12 June 2019
Resolution: Leaking pipe replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 May 2018
Resolved
Complete an annual inspection of the vessel. Your vessel was overdue for an annual inspection as of May 20, 2018.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2018
Resolution: Annual Inspection completed.
Operations/Management › Vessel Activity › Underway
Issued 18 May 2017
Resolved
Prior to carrying passengers, make vessel available for underway inspection of propulsion machinery and steering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2017
Resolved 14 September 2017
Resolution: vessel proved proper operation of all steering and machinery.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2017
Resolved
Pay overdue user fees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: Onwer provided email proof of payed user fees.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2017
Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: Stern light replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 May 2017
Resolved
Provide alco testers
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: Owner provided Alco Testers.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 May 2017
Resolved
Hydro test air receiver
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: P/V was HYDRO tested.
Fire Fighting › Fire Main › Condition
Issued 18 May 2017
Resolved
Prove proper operation of fire pump
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: Fire pump tested sat.
Documentation › Certificates/Documents › Permit, Other
Issued 18 May 2017
Resolved
Provide FCC Marine Radio Operator Permit
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 14 September 2017
Resolution: Master provided Marine Radio Operator Permit.