CHULITNA PRINCESS

CHULITNA PRINCESS is a 1998 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1998, most recently in June 2026, along with 36 deficiencies.

Records from 1998 to 2026. Most recent: inspection, 8 June 2026.

Built
1998
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

471044
Flag
UNITED STATES
—
Maury page id
psix-471044

Inspections, by type

Years with a record 23 calendar years (1998–2026)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 10.5 ft × 4.0 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS · LEWISTON, ID, UNITED STATES · built 1998
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portTALKEETNA, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

8 June 2026 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8320110
14 May 2025 Annual Inspection · Administrative Inspection · DAPI Audit · Simplified Stability Test · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8117864
26 December 2024 Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8118019
5 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7889632
22 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7694073
1 November 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7586921
23 May 2022 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7442617
19 July 2021 In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7262094
2 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7221513
2 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6966384
12 June 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6504074
25 April 2018 Simplified Stability Test
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6420651
3 April 2018 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6384654
24 October 2017 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6294117
26 June 2017 COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6187609
17 May 2016 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5886691
13 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4885159
17 May 2012 COI Inspection · Plan Review "T" Boat
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4312476
19 August 2008 DAPI Audit · Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3304006
8 May 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3227571
23 May 2007 MARPOL Annex V Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2939057
11 August 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2747995
17 May 2005 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2582039
1 June 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2135382
23 June 2003 Annual Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1825042
29 May 2002 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1644704
24 May 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1471256
10 June 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1418729
2 July 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 776715
18 May 1999 Initial Certification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1372720
3 June 1998 Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1364679

Deficiency record · 36

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025 Resolved
Install plugs/caps on both quick acting drain valves on both sea strainer to prevent engine room flooding if the valves are accidental bumped or fail.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 21 May 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025 Resolved
Prove proper operation of fuel shutoff valve on the Starboard side.
Action required: 10 - Deficiency Rectified
Due 15 May 2025
Resolved 15 May 2025
Resolution: all sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2025 Resolved
When a vessel makes changes that exceed 2 percent of the vessels weight a new stability test must be conducted. The installation of two new engines exceeds the 2 percent weight change and a new stability test must be completed prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2025
Resolved 15 May 2025
Resolution: New Stability test was condeucted and new Stability letter issued
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 December 2024 Resolved
At each initial and subsequent inspection for certification of a vessel the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems to include: Operation of the main propulsion machinery ahead and astern and operation the control mechanisms. The vessel was re-powered with a newer model engine and must have the installation inspected and conduct sea trials with a marine inspector prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2025
Resolved 15 May 2025
Resolution: Conducted sat sea trials after repower
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Instructions for life jackets was missing, post instructions for the type of life jackets being carried on board. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Photos of placards were recieved via email.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2024 Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights. The all-around white light is missing the lens cover, replace lens cover. 33 CFR 83.23(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 11 June 2024
Resolution: Received photograph with replacement all-around white light lense cover installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 May 2022 Resolved
replace combustible trash can with non combustible trash can with no holes or openings in the side or bottom
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 May 2022 Resolved
replace anchor light and starboard running light
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 22 June 2022
Resolution: all Sat
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 3 June 2020 Resolved
Fume detector not operational. Repair and test prior to operation.
Action required: 10 - Deficiency Rectified
Due 4 June 2020
Resolved 4 June 2020
Resolution: Fume detection node replaced. Positive test conducted.
Documentation › Logs/Records › Drug Test Records
Issued 17 May 2012 Resolved
Provide proof of pre-employment drug test negative results and proof of random test enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2012
Resolution: Provided.
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 17 May 2012 Resolved
Double clamp engine exhaust hoses.
Due 17 June 2012
Resolved 4 June 2012
Resolution: Hoses double clamped.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2012 Resolved
Properly install engine room bilge switch.
Due 1 June 2012
Resolved 4 June 2012
Resolution: Bilge switch installed properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2012 Resolved
Provide 60' line for life ring.
Due 1 June 2012
Resolved 25 May 2012
Resolution: Receipt provided for purchase of product.
Lifesaving › Hand Flares › Quantity
Issued 17 May 2012 Resolved
Provide 2 orange smoke signal or red hand flare. Vessel is limited to voyages of 30 min or less until provided.
Due 1 June 2012
Resolved 25 May 2012
Resolution: Receipt provided for purchase of product.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 17 May 2012 Resolved
Provide first aid kit with contents of 46 CFR 160.041.
Due 1 June 2012
Resolved 25 May 2012
Resolution: Receipt provided for purchase of product.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 17 May 2012 Resolved
Submit plans to Sector Anchorage for engine install to include spec sheet for both old and new engines.
Due 1 June 2012
Resolved 4 June 2012
Resolution: Adequate plans were submitted by vessel operator to successfully evaluate engine installation.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 17 May 2012 Resolved
Install fuel supply and return lines as per 46 CFR 182.720.
Due 1 June 2012
Resolved 4 June 2012
Resolution: Proof was provided of satisfactory materials and installation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2012 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator did not submit drawings, sketches, or written specifications describing the details of the alterations for approval prior to completing alterations the vessel's propulsion systems.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 June 2012
Resolution: The operator was directed to submit plans and specification sheets to Sector Anchorage for engine installation approval. Recommended letter of warning.
Documentation › Certificates/Documents › Stability Letter
Issued 19 August 2008 Resolved
Properly display stability letter at operating station.
Action required: 705 - Other - as specified
Due 19 August 2008
Resolved 19 August 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 August 2008 Resolved
Provide battery cover for battery.
Action required: 705 - Other - as specified
Due 19 August 2008
Resolved 19 August 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 May 2008 Resolved
repair two cracked welds where marked.
Due 19 September 2008
Resolved 19 June 2009
Lifesaving › Hand Flares › Approval
Issued 1 June 2004 Resolved
Provide 3 red hand flares and 3 orage day smokes.
Due 1 July 2004
Resolved 16 July 2004
Resolution: Provide 3 red hand flares and 3 orage day smokes provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 29 May 2002 Resolved
Provide missing BII portable fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2002
Resolution: provided
Engineering › Bilge Water Management System › Pump
Issued 29 May 2002 Resolved
Provide missing portable bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2002
Resolution: provided
Documentation › Certificates/Documents › Stability Letter
Issued 29 May 2002 Resolved
Provide stability letter on board
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2002
Resolution: provided
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 May 2002 Resolved
Provide COD on board
Due 5 June 2002
Resolved 30 May 2002
Resolution: provided
Lifesaving
Issued 18 May 1999 Resolved
INSTALL REFLECTIVE TAPE TO RING BUOY. 46 CFR 185.604
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Lifesaving
Issued 18 May 1999 Resolved
CONDUCT UNDERWAY DRILLS. 46 CFR 185.520 & .524
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
SUBMIT REQUEST TO [name withheld] OF ENGINE SHUTDOWN REQUIRED BY 46 CFR 181.420.
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
PROVIDE ADDITIONAL FIRE EXTINGUISHER. 46 CFR 181.500
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Lifesaving
Issued 18 May 1999 Resolved
PROVIDE 60 FT OF LIFELEINE TO RING BUOY. 46 CFR 180.70
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
POST VAPOR DETECTOR TEST INSTRUCTIONS FROM MFR TEST BOOKLET. 46 CFR 182.480
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Lifesaving
Issued 18 May 1999 Resolved
UPDATE FIRST AID KIT W/ INVENTORY CARD. 46 CFR 160.041
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Fire Fighting
Issued 18 May 1999 Resolved
PROVIDE 3 2.5 GALLON FIRE BUCKETS W/ LINE ATTACHED. 46 CFR 181.610
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
PROVIDE VENT CLOSURES FOR MACHINERY SPACE DUCTS. 46 CFR 182.465
Condition: Unknown
Due 2 July 1999
Resolved 10 August 1999
Lifesaving
Issued 18 May 1999 Resolved
PROVIDE 3 ADDITIONAL TYPE I ADULT PFD. PASSENGER CAPACITY LIMITED TO 15 UNTIL CORRECTED.
Condition: Unknown
Due 1 June 1999
Resolved 10 August 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.