WHARF CAT

WHARF CAT is a 1972 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 51 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 10 April 2026.

Built
1972
Last inspected
10 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WZJ9938
Flag
UNITED STATES
Maury page id
psix-47106

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)71.7 ft × 31.0 ft × 7.1 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 26

10 April 2026 Vessel Attendance · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8322963
10 April 2025 Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8109734
24 October 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8024089
6 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7907681
29 March 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7887026
4 September 2023 In-Service Inspection · Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7784017
3 September 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7787284
25 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7696588
31 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7660631
3 November 2022 Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7605548
27 April 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7439519
26 April 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7438625
24 February 2022 In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7401591
9 November 2021 In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7348036
28 April 2021 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7183032
5 April 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7170615
10 December 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7109775
21 July 2020 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7012560
7 May 2020 Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6950013
29 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6672616
22 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6417110
3 April 2018 Internal Structural Exam · Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6384545
17 April 2017 Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6126378
16 May 2016 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5878584
2 May 2016 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5867597
28 March 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5841885

Deficiency record · 51

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 May 2025 Resolved
Each survival craft must be: stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Inflatable life rafts were improperly secured with straps and a clip, preventing float-free operation and automatic inflation. Route restricted to lakes, bays, and sounds. Reconfigure life raft stowage using approved hydrostatic release units to enable float-free and automatic inflation. Limited to LBS. 705 "Prior to" removing route restriction. 46 CFR 180.130(a)(2)
Action required: 705 - Other - as specified
Resolved 8 May 2025
Resolution: HRUs installed properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The portside fuel shutoff valve was not fully operable; the reach rod did not adequately engage with the handwheel, preventing proper opening and closing of the valve. Rectify the valve control mechanism to ensure full and reliable operation to the satisfaction of the attending marine inspector. 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Reach rod connection was repaired.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 May 2025 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Observed leak in steering linkage at the helm, posing a potential fire hazard and risk of vessel's ability to maneuver safely. Repair leak to the satisfaction of the attending marine inspector. 46 CFR 182.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 13 May 2025
Resolution: Steering gear was inspected at helm with no leak observed. Area was orderly.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2025 Resolved
The intent of this part is to ensure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. The rudder arm mounts on both the starboard and port sides have cracked welds. Cracked welds were observed at all four corners of the starboard-side entrance and at the bottom two corners of the port-side entrance to the accommodation space. Weld repairs performed on various structural frames—particularly those located within the steering gear void—were incomplete. Welding was only carried out on the top side of the frames, with no welding performed underneath, leaving visible cracks. Perform weld repairs in accordance with standards ensuring full weld continuity on all affected joints. All repair work is to be conducted under the oversight and to the satisfaction of the attending marine inspector. 46 CFR 177.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 June 2025
Resolution: Verified all welds have been properly completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The stowage compartments for adult life jackets were not labeled to indicate the quantity or size of life jackets contained within. Label all life jacket stowage compartments clearly to indicate both the number of life jackets stored and their designated size. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 June 2025
Resolution: Verified proper markings on life jacket storage inside main cabin and outside overhead storage
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2025 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date: Charts; Sailing directions; Coast pilots; Light lists; Notices to mariners; Tide tables; Current tables; and all other nautical publications necessary. Charts were outdated, and several required navigational publications were missing or not readily available. Obtain and maintain up-to-date nautical charts (either electronic or paper formats are acceptable) and ensure all required navigation publications are onboard. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 27 May 2025
Resolution: Electronics subscription for updated charts verified. Physical pubs obtained.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025 Resolved
On a vessel of more than 65' in length a commercial fire hose is required IAW 181.320(b)1. One fire hose was found to have a leak. Replace IAW 181.320(b)(1) to the satisfaction of the Marine Inspector. 46 CFR 181.320.b(1)
Action required: 10 - Deficiency Rectified
Resolved 6 May 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 May 2025 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight.. each hatch that provides access to crew or passenger accommodations. Foam weatherstripping needs to be replaced due to missing or damaged to ensure weathertight. 46 CFR 177.13-1 46 CFR 171.124(a) & (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 9 June 2025
Resolution: verified weatherstripping was in place
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's alcohol testing devices on board were all expired. Vessel to get sufficient number of alcohol testing devices readily accessible on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2023
Resolution: Vessel received new alcohol testing devices on board. Verified not expired.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 25 May 2023 Resolved
A vessel must comply with the applicable requirements for any radio installations, as set forth in 47 CFR part 80. Vessel is missing a MF-DSC or MF capable operating on 2670 kHz. Vessel is restricted to Coastwise operations not more than 20 nautical miles offshore. Install MF-DSC or MF radio capable operating on 2670 kHz to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 June 2023
Resolution: Vessel had new SSB radio installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 April 2023 Resolved
Be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. Vessel is missing 01 inflatable buoyant apparatus. Vessel is limited to 34 total persons on board including crew when operating on Oceans Route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2023
Resolution: Vessel had both liferafts services and placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 24 April 2023 Resolved
A vessel must comply with the applicable requirements for any radio installations, as set forth in 47 CFR part 80. Vessel is missing a MF-DSC or MF capable operating on 2670 kHz. Install correct radio to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2023
Resolution: Revised def and issued new one
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:A pressure type connector on each conductor; A solder lug on each conductor; A splice made with a pressure type connector to a flexible lead or conductor; or;A splice that is soldered, brazed, or welded to a flexible lead or conductor. Vessel had wires on starboard side center void on A/C unit not in an enclosure. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2023
Resolution: PLaced wires in junction box
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining and watertight compartment, other than small buoyancy compartments, under all praticable conditions. Suction in stbd void did not produce suction when engaged with pump. Repair to the satisfaction of the USCG Marine Inspector. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2022
Resolved 10 May 2022
Resolution: Wasted bilge piping was replaced with new piping; bilge suction worked satisfactorily.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 9 May 2022 Resolved
WHen operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by EPA, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Vessel's sewage overboard valve is ceased in open position. Repair to the satisfaction of the USCG Marine Inspector. 33 CFR 159.7(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 10 May 2022
Resolution: Seized sewage overboard valve was replaced with brand new ball valve.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Vessel's stern light was not operational. Repair to the satisfaction of the USCG Marine Inspector. Vessel restricted to daylight operations until rectified. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 10 May 2022
Resolution: Stern light wiring was replaced with brand new wire; stern light visible and satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2022 Resolved
An adult lifejacket must be provided for each person carried on board. Vessel has 60 lifejackets adult size on board. Repair or replace additional lifejackets to the satisfaction of the USCG Marine Inspector. Vessel restricted to 60 adults allowed until rectified. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 10 May 2022
Resolution: Vessel received second order of lifejackets to meet the total allowable persons of 84 as stated on their COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2022 Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI was found to be expired as of 27AOR2022 and must be renewed Prior to the Carriage of Passengers. 46 CFR 176.100(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2022
Resolved 10 May 2022
Resolution: COI Renewal complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 December 2021 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspections. Vessel began making alterations to engine room for re-power project without approval of OCMI. Vessel shall not carry passengers until re-power project is complete and machinery meets all operational requirements to the satisfaction of the attending USCG Marine Inspector. 46 CFR 176.20-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2021
Resolved 23 February 2022
Resolution: Vessel successfully completed re-power and machinery meets op requirements.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 April 2021 Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Port steering ram bracket is missing bolts and detaching from support. Prove proper steering operation for port steering apparatus. 46 CFR 182.30-1(a) 10,C
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Cleared on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Port engine room bilge suction is inoperable. Prove proper operation of port bilge suction. 46 CFR 182.30-1(a) 60, c
Action required: 60 - Rectify deficiencies prior to movement
Due 29 April 2021
Resolved 29 April 2021
Resolution: Vessel crew proved proper bilge suction in port engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. Screw-down valve in port and starboard forepeak voids is inoperable. Prove proper operation of valve in forepeak voids. 46 CFR 182.25-5(d) 60, c
Action required: 60 - Rectify deficiencies prior to movement
Due 29 April 2021
Resolved 29 April 2021
Resolution: Vessel crew replaced screw down valves in port and starboard forepeak voids and proved proper operation of reach rod.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021 Resolved
Mechanically propelled "L" vessels shall comply with the provisions of subchapter F of this chapter. Rigid non-metallic materials are acceptable for use in bilge piping systems on all other vessels. Port engine room bilge piping is constructed of PVC. Provide metallic piping in port engine room bilge system, replacing PVC piping and area with "JB Weld" patch.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 April 2021
Resolved 29 April 2021
Resolution: Vessel crew replaced PVC piping with metallic piping.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 July 2020 Resolved
Weak link- Marking- Each link certified by the manufacture to meet the requirements of this subpart must have a corrosion resistant waterproof tag attached to it that has the following information. Buoyant Apparatus/Person Capacity/ Breaking Strength/ Meets USCG/ Made by/ Date. Cannot be read. all must be replaced prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 28 July 2020
Resolution: Replaced buoyant apparatus' with 2 25 man life rafts and 1 50 man inflatable buoyant apparatus.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Wet Exhaust Leak- The engine head, block, and exhaust manifold shall be water jacketed. Port side MDE has water leaking from exhaust flange at the inner hull penetration. 46 CFR 182.20-10(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 August 2020
Resolved 28 July 2020
Resolution: Operator replaced bolts on flange and secured leak.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2020 Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. Pre-employment drug testing in accordance with 46 CFR 16.210 has not been conducted for the crew minimum manning. Results must be in prior to carrying passengers. 28 July 2020, Vessel has min crew to conduct 12 hour operations, Def stays until all crew test results come in.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 13 August 2020
Resolution: All members of required manning crew have been pre-employment drug tested and have passed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 27 July 2020 Resolved
Invalid station bill- the station bill required by this paragraph (a) of this section must set forth the special duties and duty station of each crew member for various emergencies. Posted station bill listed MMC ratings that this vessel does not employ.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 July 2020
Resolution: Updated and correct station bill posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 July 2020 Resolved
Life Jacket Placards- Placards containing instructions for donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has four different types of life jackets and only one type of placard posted. Vessel must have a placard for each type of life jacket prior to carrying passengers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2020
Resolution: Operator printed three additional instruction placards to cover all life jackets on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Lagging- Protective gratings shall be provided at such location where persons or gear might come in contact with the exhaust pipe. (Diesel 182.20-15 sends to gas regs) STBD MDE is missing lagging at the fan area, STBD SSDG and Port SSDG have missing lagging at various areas of the exhaust piping. 46 CFR 185.15-20(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2020
Resolution: New lagging has been applied to the STBD MDE and both SSDG's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Eng Room Fuse Panel- All electrical installations shall be to the satisfaction of the officer in charge of marine inspections. STBD Machinery space has three fuse panels the forward one has missing labeling, the second and third one have open fuses allowing for accidental shock. Must be blanked off for protection of crew. 46 CFR 183.01-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2020
Resolution: All blanks have been covered and labeling has been applied to each fuse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Hydraulic pump guard- Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Port machinery space has a hydraulic pump without guards on rotating machinery. 46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2020
Resolution: New guard has been placed on the rotating portion of the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Cable Run- All electrical installations shall be to the satisfaction of the officer in charge marine inspections. 3rd void space with air handler has cable running port to stbd held up by zip ties. Proper connectors must be installed. 46 CFR 183.01-15 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2020
Resolution: Cabling holders have been installed on run between hulls.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2020 Resolved
In general compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of the vessel. Port bow railing cracked, stbd forward void three cracked structural welds, #2 stbd void cracked weld above potable water tank overhead, Port forward void space two cracked welds on structural beams, #2 port void cracked weld above potable water tank overhead. 46 CFR 177.10-1 (a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2020
Resolution: All weld repairs have been completed to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 July 2020 Resolved
Buoyant apparatus must be approved under approval series 160.010 or other standard approved by the commandant. All buoyant apparatuses are missing approval under 160-010 or other standards approved by the commandant. However all buoyant apparatuses are serviceable. All apparatuses must be replaced or evidence shown that they are approved under 160.010 or other standards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2020
Resolution: Replaced buoyant apparatus with 2 25 man life rafts and 1 50 man inflatable buoyant apparatus.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 July 2020 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire Fighting drills must also be documented for review by the Coast Guard. Training logs for drills were not compiled prior to July 2020. Logs for all drills shall be completed moving forward.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 27 July 2020
Resolution: Logs to be maintained from now on.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2020 Resolved
Portable watertight containers for distress flares and smoke signals shall be clearly marked in legible contrasting letters at least 5 inches high stating, Distress Signals. Container must be marked IAW above standards.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 July 2020
Resolution: Markings placed on container prior to our departure.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 July 2020 Resolved
Each vessel that operates beyond three nautical miles from coastline or on the high seas must have a FCC-type accepted Cat 1 406 mhz epirb, installed to float free. Hydrostatic release unit doesn't have expiration date affixed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 July 2020
Resolution: Owner provided purchase receipt and the HRU was marked based on the day of purchase.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020 Resolved
Vessel dry dock due 30 APR 2020. Prior to carrying passengers, a credit dry-dock must be conducted to the satisfaction of local OCMI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 28 May 2020
Resolution: Completed Credit Dry Dock Exam.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2018 Resolved
01199- Any vessel of at least five net tons wholly owned by a citizen or citizens of the United States is eligible for documentation under this part. This includes, but is not limited to, vessels used exclusively for recreational purposes and vessels used in foreign trade. Vessels Certificate of Documentation expired SEP17.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2018
Resolved 24 May 2018
Resolution: Received notification from NVDC that the vessels apllication for a COD has been recieved and approved.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 22 May 2018 Resolved
05104-Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped MF–DSC frequency transmitter meeting the requirements of §80.1101(c)(3) The MF or MF–DSC transmitter and receiver must be capable of operation on 2670 kHz. Vessels MF radio microphone does not operate. Vessel is restricted to 20 NM of land.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 25 May 2018
Resolution: Vessel installed a new microphone for the radio. All tests SAT
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 April 2018 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be properly insulated. Insulation on the port SSDG was improperly installed along with sections missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2018
Resolved 6 April 2018
Resolution: All insulation was properly installed or replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 3 April 2018 Resolved
At each initial inspection, the firefighting equipment shall be inspected. Vessels fixed firefighting system did not show proper annual service records. Vessel shall provide prof of annual service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2018
Resolved 6 April 2018
Resolution: Vessle provided proper inspection report for the fixed fire fighting system.
Construction/Loadline › Hull › Stringer
Issued 28 April 2017 Resolved
Vessel must comply with the structural design requirements of the aluminum hull vessel standards. Gouge and weld identified areas (5) Port Forward (5) STBD Fwd (2) STBD Laz and (2) Fwd Bullwork rail.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 10 May 2017
Resolution: Inspected weld repair and tested satisfactory.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 April 2017 Resolved
Piping including exhaust gases with temp exceeds 150 degrees must be suitably insulated where necsessary to prevent injury. Replace exhasut lagging Port and Stbd Eng in Kind.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 10 May 2017
Resolution: New lagging pads installed on Vessel. inspected satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 April 2017 Resolved
Vessel w/ installed toilet facility must have a marine sanitation device that complies with 33 CFR 159. Repair hole in MSD discharge pipe above deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 10 May 2017
Resolution: Inspected weld repair tested satisfactory.
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2016 Resolved
Unauthorized version of Coast Pilot on board. 46 CFR 185.20-35
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Vessel has proper Coast Pilot on board.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 May 2016 Resolved
Install a blank in circuit breaker panel in stbd engine room. 46 CFR 183.10-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 25 May 2016
Resolution: Breaker panel repaired.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 May 2016 Resolved
Electrical outlet box in house is burned out. 46 Cfr 176.25-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 25 May 2016
Resolution: Electrical outlet replaced.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 May 2016 Resolved
Circuit breaker panel in bridge is loose/excessive movement.. 46 CFR 183.10-10(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 25 May 2016
Resolution: Breaker panel secured.
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 May 2016 Resolved
Remote fuel shut off in stbd engine room does not operate properly. Secure reach rod to valve and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 25 May 2016
Resolution: Fuel shutoff repaired and secured.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 May 2016 Resolved
Fixed CO2 system is out of service. Needs to be serviced before next operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2016
Resolution: Vessel had all firefighting systems serviced by IFS ([name withheld]) on May 4, 2016.

Casualty record · 1

3 September 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 4 injured · activity 7787284
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.