WHARF CAT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named WHARF CAT
WHARF CAT is a 1972 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1982, most recently in April 2026, along with 188 deficiencies and 1 casualty investigation in 2023.
Records from 1982 to 2026. Most recent: inspection, 10 April 2026.
- Built
- 1972
- Last inspected
- 10 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 188 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
537858
WZJ9938
47106
Flag
UNITED STATES
366936050
Maury page id
psix-47106
Inspections, by type
…with no type recorded15
Years with a record
40 calendar years (1982–2026)
The 89 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)71.7 ft × 31.0 ft × 7.1 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP9099MMSI 366936050 · active · compulsorily equipped · granted 4 December 2024, expires 4 December 2034
WZJ9938MMSI 366936050 · expired · compulsorily equipped · granted 24 May 2014, cancelled 24 August 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 89
10 April 2026
Vessel Attendance · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8322963
10 April 2025
Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8109734
24 October 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8024089
6 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7907681
29 March 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7887026
4 September 2023
In-Service Inspection · Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7784017
3 September 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7787284
25 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7696588
31 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7660631
3 November 2022
Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7605548
27 April 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7439519
26 April 2022
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7438625
24 February 2022
In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7401591
9 November 2021
In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7348036
28 April 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7183032
5 April 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7170615
10 December 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7109775
21 July 2020
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7012560
7 May 2020
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6950013
29 April 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6672616
22 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6417110
3 April 2018
Internal Structural Exam · Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6384545
17 April 2017
Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6126378
16 May 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5878584
2 May 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5867597
28 March 2016
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5841885
1 May 2012
DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4299325
6 May 2009
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3444932
14 September 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3325975
15 May 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3207431
6 May 2008
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3191982
20 March 2007
COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2891452
4 October 2006
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2793667
25 April 2006
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2632948
26 May 2005
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2369844
26 April 2005
Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2342996
7 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2189177
20 April 2004
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2043427
10 April 2003
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1753115
4 June 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626360
10 April 2002
Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1489285
24 May 2001
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1065869
12 April 2001
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1431015
12 May 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1049599
14 April 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1462834
12 April 2000
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1384407
20 May 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 796849
12 April 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1386476
3 April 1999
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510200
21 May 1998
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 792330
12 May 1998
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1437405
30 April 1998
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1449049
10 April 1997
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1453339
7 May 1996
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1083126
11 April 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1417918
3 April 1996
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1459984
13 September 1995
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1192028
11 April 1995
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1385442
15 November 1994
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1438235
8 July 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 862665
25 May 1994
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1170126
24 May 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 859707
12 April 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1389802
10 May 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1144164
8 May 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 75010
12 April 1993
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 841704
12 April 1993
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1143675
4 December 1992
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1145600
10 November 1992
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1136324
16 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 113248
9 April 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1356114
12 April 1991
COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1240273
20 April 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1213095
13 October 1989
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1343905
16 June 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1343416
1 June 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1039497
13 April 1989
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 896900
15 June 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1201499
14 April 1988
Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 896916
22 April 1987
COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000749
22 April 1986
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1310914
22 October 1985
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 991607
29 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1290623
2 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281032
2 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971780
2 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973216
22 September 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965335
1 September 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274056
3 May 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272830
Deficiency record · 188
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 May 2025
Resolved
Each survival craft must be: stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Inflatable life rafts were improperly secured with straps and a clip, preventing float-free operation and automatic inflation. Route restricted to lakes, bays, and sounds. Reconfigure life raft stowage using approved hydrostatic release units to enable float-free and automatic inflation.
Limited to LBS.
705 "Prior to" removing route restriction.
46 CFR 180.130(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The portside fuel shutoff valve was not fully operable; the reach rod did not adequately engage with the handwheel, preventing proper opening and closing of the valve. Rectify the valve control mechanism to ensure full and reliable operation to the satisfaction of the attending marine inspector.
46 CFR 182.20-40(b)(3)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 May 2025
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire,
explosion, machinery failure and personnel injury. Observed leak in steering linkage at the helm, posing a potential fire hazard and risk of vessel's ability to maneuver safely. Repair leak to the satisfaction of the attending marine inspector.
46 CFR 182.01-5(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2025
Resolved
The intent of this part is to ensure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for
safe operation in accordance with the terms of its certificate of inspection. The rudder arm mounts on both the starboard and port sides have cracked welds. Cracked welds were observed at all four corners of the starboard-side entrance and at the bottom two corners of the port-side entrance to the accommodation space. Weld repairs performed on various structural frames—particularly those located within the steering gear void—were incomplete. Welding was only carried out on the top side of the frames, with no welding performed underneath, leaving visible cracks. Perform weld repairs in accordance with standards ensuring full weld continuity on all affected joints. All repair work is to be conducted under the oversight and to the satisfaction of the attending marine inspector.
46 CFR 177.01-5(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The stowage compartments for adult life jackets were not labeled to indicate the quantity or size of life jackets contained within. Label all life jacket stowage compartments clearly to indicate both the number of life jackets stored and their designated size.
46 CFR 185.604(f)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2025
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date: Charts; Sailing directions; Coast pilots; Light lists; Notices to mariners; Tide tables; Current tables; and all other nautical publications necessary. Charts were outdated, and several required navigational publications were missing or not readily available. Obtain and maintain up-to-date nautical charts (either electronic or paper formats are acceptable) and ensure all required navigation publications are onboard.
46 CFR 184.420
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
On a vessel of more than 65' in length a commercial fire hose is required IAW 181.320(b)1. One fire hose was found to have a leak. Replace IAW 181.320(b)(1) to the satisfaction of the Marine Inspector.
46 CFR 181.320.b(1)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 May 2025
Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight.. each hatch that provides access to crew or passenger accommodations. Foam weatherstripping needs to be replaced due to missing or damaged to ensure weathertight.
46 CFR 177.13-1
46 CFR 171.124(a) & (c)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's alcohol testing devices on board were all expired. Vessel to get sufficient number of alcohol testing devices readily accessible on board the vessel.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 25 May 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations, as set forth in 47 CFR part 80. Vessel is missing a MF-DSC or MF capable operating on 2670 kHz. Vessel is restricted to Coastwise operations not more than 20 nautical miles offshore. Install MF-DSC or MF radio capable operating on 2670 kHz to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 April 2023
Resolved
Be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. Vessel is missing 01 inflatable buoyant apparatus. Vessel is limited to 34 total persons on board including crew when operating on Oceans Route.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 24 April 2023
Resolved
A vessel must comply with the applicable requirements for any radio installations, as set forth in 47 CFR part 80. Vessel is missing a MF-DSC or MF capable operating on 2670 kHz. Install correct radio to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:A pressure type connector on each conductor; A solder lug on each conductor; A splice made with a pressure type connector to a flexible lead or conductor; or;A splice that is soldered, brazed, or welded to a flexible lead or conductor. Vessel had wires on starboard side center void on A/C unit not in an enclosure. Repair to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining and watertight compartment, other than small buoyancy compartments, under all praticable conditions. Suction in stbd void did not produce suction when engaged with pump. Repair to the satisfaction of the USCG Marine Inspector.
46 CFR 182.500(a)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 9 May 2022
Resolved
WHen operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by EPA, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Vessel's sewage overboard valve is ceased in open position. Repair to the satisfaction of the USCG Marine Inspector.
33 CFR 159.7(b)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Vessel's stern light was not operational. Repair to the satisfaction of the USCG Marine Inspector. Vessel restricted to daylight operations until rectified.
46 CFR 183.420
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2022
Resolved
An adult lifejacket must be provided for each person carried on board. Vessel has 60 lifejackets adult size on board. Repair or replace additional lifejackets to the satisfaction of the USCG Marine Inspector. Vessel restricted to 60 adults allowed until rectified.
46 CFR 180.71(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2022
Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel's COI was found to be expired as of 27AOR2022 and must be renewed Prior to the Carriage of Passengers.
46 CFR 176.100(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 December 2021
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspections. Vessel began making alterations to engine room for re-power project without approval of OCMI. Vessel shall not carry passengers until re-power project is complete and machinery meets all operational requirements to the satisfaction of the attending USCG Marine Inspector.
46 CFR 176.20-1(a)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 April 2021
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Port steering ram bracket is missing bolts and detaching from support. Prove proper steering operation for port steering apparatus.
46 CFR 182.30-1(a) 10,C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Port engine room bilge suction is inoperable. Prove proper operation of port bilge suction.
46 CFR 182.30-1(a) 60, c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021
Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. Screw-down valve in port and starboard forepeak voids is inoperable. Prove proper operation of valve in forepeak voids.
46 CFR 182.25-5(d) 60, c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021
Resolved
Mechanically propelled "L" vessels shall comply with the provisions of subchapter F of this chapter. Rigid non-metallic materials are acceptable for use in bilge piping systems on all other vessels. Port engine room bilge piping is constructed of PVC. Provide metallic piping in port engine room bilge system, replacing PVC piping and area with "JB Weld" patch.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 July 2020
Resolved
Weak link- Marking- Each link certified by the manufacture to meet the requirements of this subpart must have a corrosion resistant waterproof tag attached to it that has the following information. Buoyant Apparatus/Person Capacity/ Breaking Strength/ Meets USCG/ Made by/ Date. Cannot be read. all must be replaced prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Wet Exhaust Leak- The engine head, block, and exhaust manifold shall be water jacketed. Port side MDE has water leaking from exhaust flange at the inner hull penetration.
46 CFR 182.20-10(b)(1)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2020
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. Pre-employment drug testing in accordance with 46 CFR 16.210 has not been conducted for the crew minimum manning. Results must be in prior to carrying passengers. 28 July 2020, Vessel has min crew to conduct 12 hour operations, Def stays until all crew test results come in.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 27 July 2020
Resolved
Invalid station bill- the station bill required by this paragraph (a) of this section must set forth the special duties and duty station of each crew member for various emergencies. Posted station bill listed MMC ratings that this vessel does not employ.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 July 2020
Resolved
Life Jacket Placards- Placards containing instructions for donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has four different types of life jackets and only one type of placard posted. Vessel must have a placard for each type of life jacket prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Lagging- Protective gratings shall be provided at such location where persons or gear might come in contact with the exhaust pipe. (Diesel 182.20-15 sends to gas regs) STBD MDE is missing lagging at the fan area, STBD SSDG and Port SSDG have missing lagging at various areas of the exhaust piping.
46 CFR 185.15-20(g)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Eng Room Fuse Panel- All electrical installations shall be to the satisfaction of the officer in charge of marine inspections. STBD Machinery space has three fuse panels the forward one has missing labeling, the second and third one have open fuses allowing for accidental shock. Must be blanked off for protection of crew.
46 CFR 183.01-15 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Hydraulic pump guard- Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Port machinery space has a hydraulic pump without guards on rotating machinery.
46 CFR 177.35-15
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Cable Run- All electrical installations shall be to the satisfaction of the officer in charge marine inspections. 3rd void space with air handler has cable running port to stbd held up by zip ties. Proper connectors must be installed.
46 CFR 183.01-15 (a)
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2020
Resolved
In general compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of the vessel. Port bow railing cracked, stbd forward void three cracked structural welds, #2 stbd void cracked weld above potable water tank overhead, Port forward void space two cracked welds on structural beams, #2 port void cracked weld above potable water tank overhead.
46 CFR 177.10-1 (a)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 July 2020
Resolved
Buoyant apparatus must be approved under approval series 160.010 or other standard approved by the commandant. All buoyant apparatuses are missing approval under 160-010 or other standards approved by the commandant. However all buoyant apparatuses are serviceable. All apparatuses must be replaced or evidence shown that they are approved under 160.010 or other standards.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 July 2020
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire Fighting drills must also be documented for review by the Coast Guard. Training logs for drills were not compiled prior to July 2020. Logs for all drills shall be completed moving forward.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2020
Resolved
Portable watertight containers for distress flares and smoke signals shall be clearly marked in legible contrasting letters at least 5 inches high stating, Distress Signals. Container must be marked IAW above standards.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 July 2020
Resolved
Each vessel that operates beyond three nautical miles from coastline or on the high seas must have a FCC-type accepted Cat 1 406 mhz epirb, installed to float free. Hydrostatic release unit doesn't have expiration date affixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
Vessel dry dock due 30 APR 2020. Prior to carrying passengers, a credit dry-dock must be conducted to the satisfaction of local OCMI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2018
Resolved
01199- Any vessel of at least five net tons wholly owned by a citizen or citizens of the United States is eligible for documentation under this part. This includes, but is not limited to, vessels used exclusively for recreational purposes and vessels used in foreign trade. Vessels Certificate of Documentation expired SEP17.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 22 May 2018
Resolved
05104-Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped MF–DSC frequency transmitter meeting the requirements of §80.1101(c)(3) The MF or MF–DSC transmitter and receiver must be capable of operation on 2670 kHz. Vessels MF radio microphone does not operate. Vessel is restricted to 20 NM of land.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 April 2018
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be properly insulated. Insulation on the port SSDG was improperly installed along with sections missing.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 3 April 2018
Resolved
At each initial inspection, the firefighting equipment shall be inspected. Vessels fixed firefighting system did not show proper annual service records. Vessel shall provide prof of annual service.
Construction/Loadline › Hull › Stringer
Issued 28 April 2017
Resolved
Vessel must comply with the structural design requirements of the aluminum hull vessel standards. Gouge and weld identified areas (5) Port Forward (5) STBD Fwd (2) STBD Laz and (2) Fwd Bullwork rail.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 April 2017
Resolved
Piping including exhaust gases with temp exceeds 150 degrees must be suitably insulated where necsessary to prevent injury. Replace exhasut lagging Port and Stbd Eng in Kind.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 April 2017
Resolved
Vessel w/ installed toilet facility must have a marine sanitation device that complies with 33 CFR 159. Repair hole in MSD discharge pipe above deck.
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2016
Resolved
Unauthorized version of Coast Pilot on board. 46 CFR 185.20-35
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 May 2016
Resolved
Install a blank in circuit breaker panel in stbd engine room. 46 CFR 183.10-10
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 May 2016
Resolved
Electrical outlet box in house is burned out. 46 Cfr 176.25-15(a)
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 May 2016
Resolved
Circuit breaker panel in bridge is loose/excessive movement.. 46 CFR 183.10-10(b)
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 May 2016
Resolved
Remote fuel shut off in stbd engine room does not operate properly. Secure reach rod to valve and prove proper operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 May 2016
Resolved
Fixed CO2 system is out of service. Needs to be serviced before next operation.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 May 2009
Resolved
Switchboard located in starboard engine room requires installation of blanks in place of missing circuit breakers.
46CFR183.330
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 May 2009
Resolved
Plug cable penetrations on all switchboards in Starboard engine room 46CFR 183.330
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2009
Resolved
Replace line on ringbuoy 46 CFR 180.70.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 6 May 2009
Resolved
Label remote fuel shut off valve.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 May 2009
Resolved
Label quantity of life vests in each stowage spot.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 22 May 2008
Resolved
Ladder to upper deck is missing one step.
Fire Fighting › Fire Hoses › Connections
Issued 22 May 2008
Resolved
Fire hose tore from coupling when charged.
Construction/Loadline › Hull › Weld
Issued 25 April 2006
Resolved
Gouge and weld cracks on rudder post angle brackets on both port and starboard.
Engineering › Bilge Water Management System › Piping
Issued 25 April 2006
Resolved
Replace broken bracket for bilge pipe in lazarette.
Construction/Loadline › Hull › Weld
Issued 25 April 2006
Resolved
Gouge and weld crack in stanchion in port machinery space.
Construction/Loadline › Hull › Weld
Issued 25 April 2006
Resolved
Gouge and weld cracks in forward deck rails.
Construction/Loadline › Hull › Weld
Issued 25 April 2006
Resolved
Gouge and weld cracks in starboard void space as marked.
Documentation › Certificates/Documents › FCC SSL
Issued 26 April 2005
Resolved
Provide current FCC Safety Certificate.
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 April 2005
Resolved
Provide current copy of U.S. Coast Pilot.
Stability › Unintentional Flooding › General
Issued 26 April 2005
Resolved
Provide visible lights at operating station for each bilge high level alarm (must be separate and distinct).
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 April 2005
Resolved
Provide cover for port aft floodlight on second deck overhang.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 26 April 2005
Resolved
Mark all emergency exits "EMERGENCY EXIT, KEEP CLEAR" on both sides using at least 1 inch lettering (46 CFR 185.30-15)
Construction/Loadline › Structures › Superstructure
Issued 26 April 2005
Resolved
Gouge and weld all cracks around doors and embarkations.
Stability › Watertight Integrity › General
Issued 26 April 2005
Resolved
Provide securing devices for all hatches.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 April 2005
Resolved
Repair/replace door for starboard e/r center distribution panel. Plug/close all openings in panel.
Engineering › Steering Gear System › Rudder
Issued 26 April 2005
Resolved
Gouge and weld cracks on port rudder post angle bracket.
Stability › Intact Righting Energy › General
Issued 26 April 2005
Resolved
Provide evidence of approval for drafts exceeding maximum specified on stability letter (currently 4' 11" aft, and 4' 2" forward.) - Stability letter specifies that the mean draft, as read on the draft marks, shall not exceed 3 feet 1 inch.
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 April 2004
Resolved
Provide Red Cross CPR cards for 50% of crew.
Electrical › Electrical Distribution System (service)
Issued 27 April 2004
Resolved
Block off and remove labels from unused breakers in two bridge electrical panels. LEGACY COMPONENT DESC: Junction Box
Navigation › Electronic Positioning
Issued 27 April 2004
Resolved
Prove proper operation of malfunctioning secondary GPS (GPSMAP 210) or remove from vessel. LEGACY COMPONENT DESC: GPS/DGPS Receiver
Electrical › Electrical Distribution System (service)
Issued 27 April 2004
Resolved
Remove all dead end wires under bridge console. LEGACY COMPONENT DESC: Wiring
Navigation › Collision/Grounding Avoidance
Issued 27 April 2004
Resolved
Paint all side shields for navigation lights black matte. LEGACY COMPONENT DESC: Navigation Lights
Operations/Management › Drills/Instruction
Issued 27 April 2004
Resolved
Replace faded emergency instruction list on bridge.
Engineering › Bilge Water Management System
Issued 27 April 2004
Resolved
Label machinery space bilge high level indicator.
Lifesaving › Buoyant Apparatus
Issued 27 April 2004
Resolved
Prove proper operation of lifefloat light stbd top lifefloat (dead battery).
Lifesaving › Buoyant Apparatus
Issued 27 April 2004
Resolved
Replace three weak links for lifefloats with CG approved links (missing tags).
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 April 2004
Resolved
Prove proper operation of main engine tachometers.
Lifesaving › Lifejacket/PFD (General)
Issued 27 April 2004
Resolved
Replace personal marker lights on 10 adult and 2 child lifejackets. LEGACY COMPONENT DESC: Lights
Electrical › Electrical Distribution System (service)
Issued 27 April 2004
Resolved
Install blanks for missing breakers in stbd engine room. (re-label panels). LEGACY COMPONENT DESC: Junction Box
Electrical › Electric Generation Source (service)
Issued 27 April 2004
Resolved
Replace saltwater suction hoses on port/stbd generators.
Fire Fighting › Fire Pumps
Issued 27 April 2004
Resolved
Permanently mount port fire pump.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 April 2004
Resolved
Replace marine gear hose inboard of port engine (worn through at engine mount).
Engineering › Fuel Oil Service System
Issued 27 April 2004
Resolved
Replace Raycor filter suction hose in port e/r. LEGACY COMPONENT DESC: Hose
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 April 2004
Resolved
Install chaffing gear to protect hose jackets from wear.
Construction/Loadline › Penetrations
Issued 27 April 2004
Resolved
Seal bulkhead penetration between port machinery room and e/r.
Lifesaving › Buoyant Apparatus
Issued 29 April 2003
Resolved
Lash oars with lanyards to lifefloats.
Electrical › Electrical Distribution System (service)
Issued 29 April 2003
Resolved
Replace blanks and fill gaps on junction box in starboard engine room. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 29 April 2003
Resolved
Remove/repair dead end wiring behind generator in starboard engine rom. LEGACY COMPONENT DESC: Wiring
Electrical › Electric Generation Source (emergency)
Issued 29 April 2003
Resolved
Secure generator mounting in port and starboard engine rooms.
Electrical › Electrical Distribution System (service)
Issued 29 April 2003
Resolved
Remove or cover exposed fuse in starboard engine room. LEGACY COMPONENT DESC: Fuse
Fire Fighting › Fire Pumps
Issued 29 April 2003
Resolved
Repair leaking valve on sea suction to fire main pump on port side. LEGACY COMPONENT DESC: Suction Valve
Engineering › Sea-water System (primary cooling)
Issued 29 April 2003
Resolved
Double clamp hose on port main engine sea suction.
Engineering › Steering Gear System
Issued 29 April 2003
Resolved
Replace hydraulic hose on port steering pump. LEGACY COMPONENT DESC: Hydraulic Hose
Electrical › Electric Generation Source (service)
Issued 29 April 2003
Resolved
Repair/replace cover on port generator motor.
Fire Fighting › Combustible Materials
Issued 29 April 2003
Resolved
Remove combustibles from engine rooms (paper towels).
Lifesaving › Buoyant Apparatus
Issued 29 April 2003
Resolved
Patch two blistered areas on top center lifefloat.
Lifesaving › Lifebuoys
Issued 29 April 2003
Resolved
Install corrosion resistant hook on life ring float light.
Lifesaving › Lifejacket/PFD (General)
Issued 29 April 2003
Resolved
Replace worn retro-reflective tape on 27 adult and 2 child life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Communications › Radio Communications
Issued 29 April 2003
Resolved
Mount emergency broadcast placard as operating station.
Navigation › Piloting/Steering
Issued 29 April 2003
Resolved
Provide updated tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Construction/Loadline
Issued 29 April 2003
Resolved
Provide written proposal to enclose railing on upper deck in accordance with 46 CFR 177.900
Lifesaving › Buoyant Apparatus
Issued 29 April 2003
Resolved
Install black polypropylene painters on all life floats or a line that is certified to be ultraviolet resistant.
Lifesaving › Hand Flares
Issued 10 April 2002
Resolved
LABEL FLARE BOX "DISTRESS SIGNALS" LEGACY COMPONENT DESC: Marking
Lifesaving › Lifejacket/PFD (General)
Issued 10 April 2002
Resolved
RENEW RETRO-REFLEXIVE TAPE ON 13 PFD'S. LEGACY COMPONENT DESC: Marking
Engineering › Bilge Water Management System
Issued 10 April 2002
Resolved
RENEW BILGE PIPE HANGER IN PORT AFT LAZARETTE. LEGACY COMPONENT DESC: Piping
Engineering › Steering Gear System
Issued 10 April 2002
Resolved
PLACE DOUBLE NUT OR EQUIVALENT FOR STARBOARD RUDDER RAM. LEGACY COMPONENT DESC: Linkage
Electrical › Electric Supply System (service)
Issued 10 April 2002
Resolved
PLACE CAPS ON BATTERIES. LEGACY COMPONENT DESC: Battery Installation
Engineering › Freshwater System (jacketwater cooling)
Issued 10 April 2002
Resolved
RENEW FRESH WATER PIPING ON BOTH ENGINES. LEGACY COMPONENT DESC: Piping
Electrical
Issued 10 April 2002
Resolved
Rewire/re-route Port and Stbd engineroom blower fans wiring.
Engineering › Bilge Water Management System
Issued 10 April 2002
Resolved
Replace bilge pipe thru bulkhead penetrations & waste plates thru out vsl port/stbd where needed. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Hull
Issued 10 April 2002
Resolved
Weld cracks at port/stbd main deck gateways.
Engineering › Diesel Engine (auxiliary)
Issued 10 April 2002
Resolved
Fix/repair Generator Base mounts iwo engineroom hatch in both enginerooms. LEGACY COMPONENT DESC: Bedplate
Construction/Loadline
Issued 12 April 2001
Resolved
WELD ALL CRACKED WELDS ON PORT AND STBD FORWARD VOID (FORE PEAK COMPT) IN WAY OF AFT BULKHEAD ON OVERHEAD/IN BETWEEN PONTOONS.
Construction/Loadline
Issued 12 April 2000
Resolved
WELD CRACKS IN WAY OF DECK LONGITUDINALS IN THE COLLISION VOID.
Construction/Loadline
Issued 12 April 2000
Resolved
WELD CRACK IN WAY OF SUPERSTRUCTURE DECK ANGLE IN STBD FORWARD VOID.
Lifesaving
Issued 12 April 1999
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILL TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 12 May 1998
Resolved
PROVIDE 3/4 FULL INDICATOR FOR SEWAGE TANK.
Accommodation/Occupational Safety
Issued 12 May 1998
Resolved
1. REPLACE CRACKED PORT WINDOW ON PILOT HOUSE._x001C_ _x001C_ 2. REPLACE CRACKED PILOT HOUSE DOOR WINDOW.
Engineering
Issued 12 May 1998
Resolved
RENEW STARBOARD SHAFT CUTLASS BEARING.
Electrical
Issued 12 May 1998
Resolved
1. SECURE WIRES IN OVERHEAD EVERY 18-24 INCHES._x001C_ _x001C_ 2. REPLACE BROKEN CLAMPS ON DISCHARGE SIDE OF STARBOARD GENERATOR & ON HULLPENETRATION.
Construction/Loadline
Issued 12 May 1998
Resolved
1. REMOVE STEEL PLATE - BILGE LINE, PORT SIDE, MACHINERY ROOM.
Deck/Cargo
Issued 12 May 1998
Resolved
1. REPAIR CRACKED WELD ON PORT FORWARD TOWING BITT IN FOREPEAK.
Construction/Loadline
Issued 12 May 1998
Resolved
1. INSTALL BRACKETS FOR BILGE EDUCTOR PIPING._x001C_ _x001C_
Construction/Loadline
Issued 12 May 1998
Resolved
1. COMPLETE WELDING OF PLATE IN TUNNEL, HULL (BOW)_x001C_ 2. REPAIR CRACK - RUB RAIL, STARBOARD SIDE OUTBOARD, NEAR STEM_x001C_ 3. REPAIR STRESS CRACK STARBOARD INNER HULL 6 FEET FROM STEM._x001C_ 4. REPAIR CRACK IN TRANSOM PLATING, CENTERLINE, UPPER PLATING
Fire Fighting
Issued 30 April 1998
Resolved
Install battery operated smoke detectors that beep when the battery goes low power as per 46 CFR 181.400.
Electrical
Issued 30 April 1998
Resolved
Rewire electrical box in steering space and remove all wire nuts and install compresion connectors as per 46 CFR 183.340.
Lifesaving
Issued 30 April 1998
Resolved
Install proper gooseneck sewage vent with flame screen as per 33 CFR 159.95.
Fire Fighting
Issued 30 April 1998
Resolved
Replace starboard side fire hose before vessel sails as per 46 CFR 181.320.
Documentation
Issued 30 April 1998
Resolved
Post COI in passenger space before vessel sails as per 46 CFR 176.306.
Lifesaving
Issued 30 April 1998
Resolved
Stencil vessel name on EPIRB before vessel sails as per 46 CFR 185.604.
Lifesaving
Issued 30 April 1998
Resolved
properly outfit vessles liferings, one with water light, one with line, onewithout anything as per 46 CFR 180.70.
Construction/Loadline
Issued 3 April 1996
Resolved
Identify source of stray current in vessels engineroom and make repairs to the number two transverse frame as identifyed during drydock exam.
Unknown
Issued 13 September 1995
Resolved
EMPLOYER DRUG PROGRAM MISSING EMPLOYEE ASSISTANCE PROGRAM
Construction/Loadline
Issued 24 May 1994
Resolved
Make permanent repairs to fractures on port and starboard door frames located amidships main deck.
Fire Fighting
Issued 12 April 1994
Resolved
Replace damaged section of fire hose with a new hose.
Electrical
Issued 12 April 1994
Resolved
Install blanks in breaker panel boxes starboard eng room.
Construction/Loadline
Issued 12 April 1994
Resolved
Weld stress cracks on stdb rudder post support bracket, port forward bulkhead in #2 hold and aft section of fore peak by bulkhead in the overhead.
Engineering
Issued 12 April 1994
Resolved
Fix leak in lube oil line stbd eng room over battery box.
Electrical
Issued 12 April 1993
Resolved
PROVIDE CIRCUIT IDENTIFICATION CARD/LABELS FOR PANELBOARDS IN STBD ENGINE ROOM.
Engineering
Issued 12 April 1993
Resolved
SECURE PORT GENERATOR BATTERY CABLES WITH CLAMPS SO THAT THEY DO NOT LAY INBILGES.
Construction/Loadline
Issued 12 April 1993
Resolved
RECLAMP BILGE SUCTION LINES THAT ARE LOOSE.
Engineering
Issued 12 April 1993
Resolved
PROVIDE FLAME SCREENS FOR DIESEL FUEL TANK GOOSENECK VENTS & COMPARTMENT VENTS FOR PORT & STBD MACHINERY ROOMS.
Electrical
Issued 12 April 1993
Resolved
PROVIDE WATERTIGHT STUFFING TUBES ON ALL MOTORS & PANELS LOCATED IN WET/DAMP LOCATIONS.
Construction/Loadline
Issued 12 April 1993
Resolved
RENEW CRACKED THREADED ADAPTER ON STBD MACHINERY ROOM BILGE SUCTION LINE.
Electrical
Issued 12 April 1993
Resolved
PROVIDE GENERATOR DISCONNECT SWITCH HANDLE FOR STBD SWITCHBOARD.
Documentation
Issued 12 April 1993
Resolved
PROVIDE & POST STABILITY LETTER.
Lifesaving
Issued 12 April 1993
Resolved
PROVIDE RETROFLECTIVE TAPE ON ALL LIFEFLOATS AS REQUIRED BY 46 CFR 160.010--3(p)
Navigation
Issued 12 April 1993
Resolved
MAKE PERMANENT REPAIR TO EXCESS PLAY IN STBD RUDDER QUADRANT ARM TO RAM CONNECTION.
Electrical
Issued 20 April 1990
Resolved
REPLACE FITTINGS AND WIRING FOR NAVIGATION LIGHTS ON MAST.
Lifesaving
Issued 20 April 1990
Resolved
PLACE ON BOARD ONE (1) ADDITIONAL COAST GUARD APPROVED ADULT-SIZED PERSONALFLOTATION DEVICE.
Navigation
Issued 20 April 1990
Resolved
REALIGN STERN LIGHT WITHIN LENS.
Construction/Loadline
Issued 13 October 1989
Resolved
GOUGE TO GOOD METAL AND WELD FRACTURES IN CORNERS OF DOORS.
Construction/Loadline
Issued 13 October 1989
Resolved
CROP AND RENEW FRACTURES IN PORT AND STARBOARD PONTOONS IN WAY OF STEM AND BOW RUB RAIL JOINT.
Construction/Loadline
Issued 13 October 1989
Resolved
CROP AND RENEW IN KIND VERTICAL FRACTURE IN COLLISION BULKHEAD IN WAY OF BOTTOM PLATE, TURN OF TUNNEL, PORT SIDE.
Construction/Loadline
Issued 13 October 1989
Resolved
CROP AND RENEW IN KIND BOTTOM PLATE FROM BOW RUB RAIL 6'5" AFT, FROM PORT TO STARBOARD PONTOON SEAMS.
Construction/Loadline
Issued 13 October 1989
Resolved
GOUGE TO GOOD METAL AND REWELD ANCHOR HAWSE MOUNTING AT BOW RAIL AND RUB RAIL.
Construction/Loadline
Issued 13 October 1989
Resolved
GOUGE TO GOOD METAL AND REWELD NUMEROUS FRACTURED AND SEPARATED WELDS THROUGHOUT FOREPEAK AREA.
Construction/Loadline
Issued 13 October 1989
Resolved
CROP AND RENEW IN KIND CRACKED, FACTURED, AND SEPARATED FRAMES THROUGHOUT FOREPEAK SPACE.
Construction/Loadline
Issued 13 October 1989
Resolved
CROP AND RENEW IN KIND TRANSVERSE FRACTURES IN BOTTOM PLATE IN WAY OF COLLISION BULKHEAD AND TURN OF TUNNEL, PORT AND STARBOARD SIDE.
Deck/Cargo
Issued 13 April 1989
Resolved
PORT MAST STAY BROKEN AT SITE OF PREVIOUS REPAIR.
Lifesaving
Issued 13 April 1989
Resolved
PROVIDE STENCILING/TAGS WITH CORRECT NUMBERING INFORMATION FOR PFD STOWAGE.
Fire Fighting
Issued 13 April 1989
Resolved
PROVIDE DOCUMENTATION FOR LATEST HYDROSTATIC TEST OF CO2 CYLINDERS (PORT ENGINEROOM).
Electrical
Issued 13 April 1989
Resolved
REMOVE LOOSE ELECTRIC CABLE IN PORT FOREPEAK.
Lifesaving
Issued 13 April 1989
Resolved
REPLACE REQUIRED RETRO-REFLECTIVE TAPE ON 108 PFDS (98 ADULT, 10 CHILD).
Lifesaving
Issued 13 April 1989
Resolved
PROVIDE CAPACITY TAGS FOR WEAK LINKS (3).
Fire Fighting
Issued 13 April 1989
Resolved
REPLACE PORT FANTAIL B-I FIRE EXTINGUISHER WITH B-II.
Electrical
Issued 13 April 1989
Resolved
REPAIR LOOSE CONNECTION ON LIGHT AFT OF WHEELHOUSE.
Navigation
Issued 13 April 1989
Resolved
STARBOARD RUDDER POST NUT MISSING COTTER PIN. STARBOARD RUDDER RAM SECURINGBRACKET MISSING NUT/PIN.
Electrical
Issued 13 April 1989
Resolved
REMOVE EXCESS BILGE ALARM CABLE AND WATER TEMPERATURE SENDER CABLE IN STARBOARD ENGINE ROOM.
Documentation
Issued 13 April 1989
Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Documentation
Issued 13 April 1989
Resolved
PROVIDE AND POST COPY OF STABILITY DOCUMENTATION.
Electrical
Issued 13 April 1989
Resolved
REPLACE WIRING CONNECTION TO VESSEL'S HORN.
Electrical
Issued 13 April 1989
Resolved
REPLACE WORN WIRE SHIELDING ON PORT FANTAIL FISHING LIGHTS.
Lifesaving
Issued 13 April 1989
Resolved
REPLACE LINE FROM LIFEFLOAT TO WATERLIGHT (BOTTOM FLOAT, CENTER FOREWARD STACK).
Electrical
Issued 13 April 1989
Resolved
ADJUST PORT GENERATOR OVERSPEED PROTECTION TO TRIP AT OR BELOW 65HZ.
Construction/Loadline
Issued 13 April 1989
Resolved
REMOVE MAIN DECK PLATING FORWARD OF PASSENGER AREA FOR INSPECTION OF FOREPEAK AREAS.
Fire Fighting
Issued 13 April 1989
Resolved
INSTALL REMOTE SENSOR FOR FIXED CO2 FIRE EXTINGUISHING SYSTEM IN STARBOARD ENGINE ROOM.
Fire Fighting
Issued 13 April 1989
Resolved
REPLACE MISSING PLASTIC COVER FOR PULL SWITCH FOR FIXED CO2 SYSTEM.
Electrical
Issued 14 April 1988
Resolved
REPAIR OR REPLACE INOPERATIVE OVERSPEED TRIP ON PORT S/S GENERATOR.
Engineering
Issued 29 April 1985
Resolved
REPAIR REACH RODS TO BILGE INDUCTION VALVES IN PORT AND STARBOARD BOW COMPARTMENTS.
Construction/Loadline
Issued 29 April 1985
Resolved
GOUGE AND WELD FRACTURE IN GUNWALE IN WAY OF #3 STARBOARD VIOD COMPARTMENT.
Electrical
Issued 29 April 1985
Resolved
REPAIR AND PROVE OVERSPEED TRIP ON STARBOARD GENERATOR.
Casualty record · 1
3 September 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 4 injured · activity 7787284
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.