Records from 1979 to 2011. Most recent: inspection, 8 December 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
8 December 2011
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4205010
27 September 2006
Deficiency Check · MARPOL Annex V Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2806492
21 August 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2755114
6 June 2006
Inclining Experiment
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2797815
6 April 2005
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2326018
1 September 2000
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1053619
27 April 2000
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816482
23 March 2000
Deadweight Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1406681
14 January 2000
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 814733
6 October 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 722769
6 October 1999
Deficiency Check · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888885
15 September 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 212259
22 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 115405
22 July 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1471721
28 April 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 793037
31 August 1998
Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 799672
8 April 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1124043
20 February 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 781297
24 November 1997
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 775307
4 August 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1117196
12 June 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1110846
17 April 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1100714
11 April 1997
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1106822
11 February 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1110185
3 February 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1104108
30 April 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085904
12 March 1996
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081115
2 November 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880358
13 March 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175680
22 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855916
10 March 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164608
8 October 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843697
29 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150710
9 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831781
12 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834749
25 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944668
8 June 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959992
11 May 1992
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270831
17 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950773
9 January 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 951994
15 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246323
18 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932892
18 March 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247392
11 October 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936081
10 July 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931229
23 January 1990
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212641
14 April 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023060
7 April 1979
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318659
Documentation › Certificates/Documents › Stability Letter
Issued 8 May 2007
No resolution recorded
Vessel restricted from carrying passengers until valid stability letter received by [name withheld].
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Stability Letter
Issued 8 May 2007
No resolution recorded
Vessel restricted from operating as an Oceanographic Research Vessel until valid stability letter received by [name withheld].
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Stability Letter
Issued 27 February 2007
Resolved
Provide valid stability letter to Sector Anchorage OCMI. Vessel restricted from carrying more than 6 passengers until corrected.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Resolution: Cleared this requirement & issued 2 seperate requirements (01 & 02 - No passengers & no operating as ORV until valid stability ltr rcvd by [name withheld]).
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 September 2006
Resolved
Remove powerstrips, extension chords & non-permanent electrical appliances from vessel (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Resolution: Rcvd ltr dtd 09Mar07 indicating removal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 September 2006
Resolved
Remove or properly terminate dead-ended wire - port side beneath operating station (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Resolution: Observed photo w/ wire inserted into newly installed J box.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 September 2006
Resolved
Make anchor light visible from all directions (raise)(extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Resolution: Observed photo w/ anchor light clear of obstructions.
Construction/Loadline › Structures › Door
Issued 27 September 2006
Resolved
Make stbd wheelhouse door handle operable (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Resolution: Rcvd ltr dtd 09Mar2007 indicating repair.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 September 2006
Resolved
Install guards/chains btwn rail & upper deck lab (port/stbd) (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 September 2006
No resolution recorded
Mark vessel name on bow (port & stbd) (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 September 2006
Resolved
Provide updated Coast Pilot & Light List (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 10 October 2006
Resolution: Rcvd ltr dtd 09Mar07 indicating pubs aboard.
Communications › Audible Communications › Bell
Issued 27 September 2006
Resolved
Install 300 mm (11.8") bell (extended due date from 06Oct06 to 10Oct06 per [name withheld] telephone request).
Action required: 705 - Other - as specified
Resolved 7 March 2007
Resolution: Rcvd ltr dtd 09Mar07 that bell was purchased.
Communications › Public Address System › Broadcast Location
Issued 27 September 2006
No resolution recorded
Install fixed public address system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 27 September 2006
No resolution recorded
Provide plans for installation of fixed fire extinguishing system for engine room. Upon approval, install system in accordance with plans - prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Incline Test › General
Issued 6 April 2005
No resolution recorded
Complete Stability calculations and tests for Exposed waters criteria.
Condition: Unknown
Action required: 705 - Other - as specified
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 6 April 2005
Resolved
Complete Hydro tests on air receivers and renew inspection plates. Present for internal inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 September 2006
Resolution: Observed hydrostatic testing certificate dated 20Sep05.
Lifesaving › Lifefloat › Markings
Issued 27 April 2000
Resolved
COMPLETE REPAIRS AND MARKING OF VESSEL'S NAME ON ALL LIFEFLOATS PRIOR TO _x001C_CARRYING PASSENGERS ON VOYAGES BEYOND RIVERS ROUTE.
Condition: Unknown
Due 27 May 2000
Resolved 21 August 2006
Resolution: Deficiency cleared
Documentation › Certificates/Documents › Stability Letter
Issued 23 March 2000
Resolved
VESSEL IS RESTRICTED TO RIVERS ROUTE PENDING APPROVAL OF RESULTS OF THE DEAD WEIGHT SURVEY.
Condition: Unknown
Due 29 June 2000
Resolved 21 August 2006
Resolution: Deficiency corrected on previous inspection.
Navigation
Issued 6 October 1999
Resolved
PRIOR TO SAILING AND NO LATER THAN 13 OCT 99, DEMONSTRATE COMPLIANCE W/ 46CFR177.800(d)(2), FOR THE PILOT HOUSE & ADJCENT ACCOMMODATION AREA.
Condition: Unknown
Due 13 October 1999
Resolved 8 October 1999
Documentation
Issued 6 October 1999
Resolved
NO LATER THAN 03 JAN 2000, DETERMINE NEW LIGHTSHIP DATA, DEMONSTRATE COMPLIANCE WITH APPLICABLE STABILITY CRITERIA, AND OBTAIN APPROVAL (AND REVISED STABILITY LETTER AS APPROPRIATE) FROM COMMANDING OFFICER, MARINE SAFETY CENTER
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 22 July 1999
Resolved
PRIOR TO CARRYING PASSENGERS DEMONSTRATE PROPER LOADING/DRAFT OF VESSEL IN COMPLIANCE WITH VESSELS STABILITY LETTER.
Condition: Unknown
Due 22 July 1999
Resolved 22 July 1999
Engineering
Issued 22 July 1999
Resolved
PROVIDE PROPELLER SHAFT RUNOUT READINGS "CONDITION FOUND REPORT" BOTH PORT AND STBD SHAFTS
Condition: Unknown
Due 15 September 1999
Resolved 28 September 1999
Construction/Loadline
Issued 22 July 1999
Resolved
PROVIDE CONDITION FOUND REPORT "NDT" OF MAIN ENGINE THROUGH HULL EXHAUST PORTS FOR SUSPECTED CRACKS AT 6 & 12 OCLOCK.
Condition: Unknown
Due 15 September 1999
Resolved 28 September 1999
Construction/Loadline
Issued 22 July 1999
Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE TEMP REPAIRS TO CRACKED EXHAUST PIPE, BOTH PORT AND STARBOARD, IN WAY OF THE OVERBOARD DISCHARGE.
Condition: Unknown
Due 21 September 1999
Resolved 28 September 1999
Navigation
Issued 22 July 1999
Resolved
PROVIDE REPAIR TO PORT RUDDER IN WAY OF CRACKED WELD, TOP TO BOTTOM OUTBOARD TRAILING EDGE.
Condition: Unknown
Due 21 September 1999
Resolved 28 September 1999
Construction/Loadline
Issued 22 July 1999
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE VESSEL FOR DRYDOCK EXAMINATION DUE TOGROUNDING.
Condition: Unknown
Due 14 September 1999
Resolved 28 September 1999
Engineering
Issued 22 July 1999
Resolved
SUBMIT PLANS FOR APPROVAL MODIFING CONVERSION OF EXHAUST FROM DRY TO WET ORMODIFY EXHAUST DISCHARGE ABOVE WATERLINE.
Condition: Unknown
Due 22 July 1999
Resolved 22 July 1999
Accommodation/Occupational Safety
Issued 28 April 1999
Resolved
BOTH PRESSURE VESSELS TO BE HYDRO TESTED.
Condition: Unknown
Due 21 May 1999
Resolved 18 May 1999
Construction/Loadline
Issued 31 August 1998
Resolved
PRIOR TO CARRYING PASSENGERS OFF SHORE, MAKE PERMANENT REPAIRS TO CRACK IN WAY OF PORT EXHAUST SIDE SHELL. TEMPORARY REPAIR TO BE MONITORED WHILE UNDERWAY. PERMANENT REPAIRS TO BE STARTED BY 17AUG98. CARRIAGE OF PASSENGERS PROHIBITED AFTER 17AUG98 UNTIL PERMANENT REPAIRS COMPLETED.
Condition: Unknown
Due 13 September 1998
Resolved 18 September 1998
Lifesaving
Issued 8 April 1998
Resolved
PRIOR TO CARRYING MORE THAN 70 PERSONS ON COASTWISE, LAKES, BAYS AND SOUND ROUTE, PROVIDE CG APPROVED PRIMARY LIFE SAVING FOR 45 PERSONS AND THREE (3)CG APPROVED INTERNATIONAL ORANGE RING BUOYS.
Condition: Unknown
Due 8 April 1998
Resolved 6 July 1998
Lifesaving
Issued 3 February 1997
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR ALL 5 LIFERINGS BEFORE NEXT OPERATION.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Construction/Loadline
Issued 3 February 1997
Resolved
PROVIDE BILGE STRAINER & REPAIR CORROSION ON BILGE SUCTION LINE FOR #2 COMPARTMENT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997
Resolved
RE-FASTEN CLAMP ON SEWAGE LINE IN #2 COMPARTMENT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Lifesaving
Issued 12 March 1996
Resolved
CG-835s #1, 2, 4, 5 CAN BE CLEARED ADMINISTRATIVELY BY SENDING LETTER FROM MASTER OF VSL TO MIONY INCLUDE MASTER'S LIC # AT SIGNITURE BLOCK.
Condition: Unknown
Due 14 March 1996
Resolved 16 April 1996
Engineering
Issued 12 March 1996
Resolved
PROPERLY INSTALL REMOTE F/O SHUT-OFF VALVE TO F/O SYSTEM. REMOTE F/O SHUTOFF VALVE MUST BE LOCATED OUTSIDE OF E/R OR WITHIN 12" OF DOOR TO E/R.
Condition: Unknown
Due 12 April 1996
Resolved 30 April 1996
Lifesaving
Issued 12 March 1996
Resolved
PROPERLY MOUNT DONNING INSTRUCTIONS FOR LIFEJACKETS IN PASSENGER AREAS.
Condition: Unknown
Due 14 March 1996
Resolved 16 April 1996
Electrical
Issued 12 March 1996
Resolved
PROPERLY INSTALL COVER STBD SIDE CREWS QUARTERS FWD OF E/R ON LIGHT SWITCH.
Condition: Unknown
Due 14 March 1996
Resolved 16 April 1996
Lifesaving
Issued 12 March 1996
Resolved
PROPERLY INSTALL WHILES ON ALL LIFEJACKETS.
Condition: Unknown
Due 14 March 1996
Resolved 16 April 1996
Engineering
Issued 10 March 1994
Resolved
HYDROTEST TWO (2) PRESSURE VESSELS LOCATED IN ENGINE ROOM IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Construction/Loadline
Issued 10 March 1994
Resolved
REPAIR REMOTE BILGE VALVE HANDLE FOR FOREPEAK.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Fire Fighting
Issued 10 March 1994
Resolved
REPLACE FIRE PUMP GAGE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 12 March 1993
Resolved
PROVIDE ONE CG APPROVED WATERLIGHT FOR RINGBOUY CLOSIST TO PILOT HOUSE.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Documentation
Issued 12 March 1993
Resolved
PROVIDE ORIGINAL STABILITY LETTER ONBOARD._x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Electrical
Issued 12 March 1993
Resolved
PROVIDE PROPER KNOB ON AMMETER SELECTOR SWITCH LOCATED ON GEN SHORETIE CONTROL BOARD IN ENGINEROOM._x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Construction/Loadline
Issued 12 March 1993
Resolved
REPLACE MELTED BILGE OVERBOARD DISCHARGE LINE LOCATED IN THE FORWARD PORT CORNER OF THE ENGINEROOM.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Construction/Loadline
Issued 12 March 1993
Resolved
PROVIDE PORTABLE HAND PUMP FOR FIREFIGHTING AND DEWATING (I PUMP).
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Electrical
Issued 12 March 1993
Resolved
PROVIDE WIRE SECURING BRACKETS FOR THE FOLLOWING ELECTRICAL EQUIPMENT: A. BOTH SOLENOID COILS FOR THE AIRSTART SYSTEM ON BOTH MDE'S. B. PUMP CONTROLSWITCH BOX FOR A/C CHILL WATER PUMP, LOCATED OUTBOARD OF STARBARD MAIN ENGINE.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Documentation
Issued 8 June 1992
Resolved
PROVIDE APPROVED STABILITY CALCULATIONS TO INCLUDE CANOPY, TO LOCAL [name withheld] ARCHITECT INFORMATION, CANOPY MAY BE INSTALLED UNTIL COMPLETION OF THIS REQUIREMENT._x001C_ _x001C_
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Engineering
Issued 11 May 1992
Resolved
REINSTALL KEEL COOLER AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Construction/Loadline
Issued 11 May 1992
Resolved
MAKE APPROVED REPAIR TO 30" CRACK AND SET-IN AT BOTTOM SEAM OF SKEG APPROXIMATELY 20 FEET FORWARD OF AFT END OF SKEG. BEFORE AND AFTER PHOTOGRAPHS OF GOOD QUALITY AND QUANTITY MAY BE SUBMITTED TO ATTENDING USCGMARINE INSPECTOR TO PROVE COMPLIANCE WITH THIS REQUIREMENT.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992