MAURY USCG vessel records Sign in
← All vessels

HULA GIRL

HULA GIRL is a 1972 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1986, most recently in January 2026, along with 49 deficiencies.

Records from 1986 to 2026. Most recent: inspection, 15 January 2026.

Built
1972
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYZ7103
Flag
UNITED STATES
367160070
Maury page id
psix-47121

Inspections, by type

…with no type recorded8
Years with a record 37 calendar years (1986–2026)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 34 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA/WESTPORT · WESTPORT WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 23 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
23 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYZ7103MMSI 367160070 · active · compulsorily equipped · granted 10 January 2017, expires 12 March 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 77

15 January 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8297194
7 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8249453
27 December 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8051360
17 January 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7850194
12 October 2023 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7803703
9 January 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7617933
18 October 2022 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7618313
19 January 2022 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7382185
2 December 2021 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7360672
11 July 2021 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 7252937
13 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7076150
11 October 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6835643
25 September 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6821868
1 October 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6551998
13 October 2017 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6288594
29 September 2017 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6280269
6 October 2016 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6016962
14 October 2015 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5744289
4 October 2015 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5735098
1 October 2014 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4992537
20 October 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3868175
24 September 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326268
4 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3141860
16 October 2007 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3080474
2 October 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3066740
11 June 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2958738
5 October 2006 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2790193
26 April 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2693027
4 January 2006 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2560128
24 October 2005 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2518639
17 November 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2243171
21 October 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2219147
10 February 2004 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2006424
28 October 2003 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928349
21 February 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1744305
30 September 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1679229
5 May 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1614132
15 January 2002 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1477658
25 October 2001 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 772035
14 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 49070
17 October 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 823337
24 January 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 815933
28 December 1999 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811945
9 December 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 812325
30 November 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1446848
2 November 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 796806
20 January 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 790327
20 January 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 796800
13 January 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 810487
5 November 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 803234
23 October 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1468015
24 October 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1458470
10 October 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390616
21 November 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374800
14 February 1996 Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1377711
26 October 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431571
12 October 1994 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1387627
9 November 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 847773
25 October 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1462361
6 November 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 826018
28 October 1992 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1473346
1 April 1992 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 948001
2 March 1992 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 960832
2 March 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961133
10 October 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1247457
5 March 1991 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 905772
5 March 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 938970
29 November 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213761
1 November 1990 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 911298
29 March 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216915
8 March 1990 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 913669
6 March 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 889613
20 September 1988 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042944
7 March 1988 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1029510
10 March 1987 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1029313
9 October 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1315297
10 April 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 999629

Deficiency record · 49

Communications › Radio Communications › EPIRB
Issued 6 October 2016 Resolved
Replace expired EPIRB battery.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 10 October 2016
Navigation › Piloting/Steering › Marine Charts
Issued 2 October 2007 Resolved
Provide the following current navigational charts, 18003, 18500 prior to the carriage of passengers.
Due 2 November 2007
Resolved 2 October 2007
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 24 October 2005 Resolved
Renew hydrostatic release on IBA prior to carrying of passengers.
Due 1 March 2006
Resolved 26 April 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 October 2004 Resolved
Provide proof of service IAW for portable fire extinguishers prior to the carriage of passengers for hire. Operator has been doing his own maintenance, all extinguishers are in good condition, but the maintenance does not meet NFPA-10 requirements for annual service.
Due 21 November 2004
Resolved 17 November 2004
Communications › Radio Communications › EPIRB
Issued 21 October 2004 Resolved
Provide proof of EPIRB NOAA registration. Vessel is restricted to lakes, bays and sounds; and rivers routes until corrected. (Vessel is out of service for the winter).
Due 21 November 2004
Resolved 17 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 September 2002 Resolved
Replace expired medications with medications that have not exceeded their expiration dates.
Due 30 October 2002
Resolved 30 September 2002
Resolution: Received digital pictures of newly purchased medications.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 30 September 2002 Resolved
Provide valid hydrostatic release for vessel's EPIRB. Currently 2002 and 2003 are "scratched out" for expiration date.
Due 30 October 2002
Resolved 30 September 2002
Resolution: Received digital picture of newly installed hydrostatic release showing a 2004 expiraion date.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 September 2002 Resolved
Replace floating waterlight battery. Current battery has no expiration date and the operator could not remember when he had last replaced this item. Advised the operator that he may mark the battery with a label if no expiration date is marked on the battery.
Due 30 October 2002
Resolved 30 September 2002
Resolution: Received a digital picture of a new battery installed with a label indicating the installation date.
Electrical › Electrical Distribution System (service)
Issued 30 September 2002 Resolved
Replace twist-on type connectors (wire nuts) throughout the vessel with approved connectors. LEGACY COMPONENT DESC: Wiring
Due 30 October 2002
Resolved 30 September 2002
Resolution: Received digital pictures of indicated wire splices now joined with approved ''pressure type'' connectors.
Construction/Loadline › Structures
Issued 30 September 2002 Resolved
Make engineroom hatches water-tight. Provide proposal to [name withheld], Oregon. Current arrangement is not watertight and no retaining devices are in place. LEGACY COMPONENT DESC: Machinery Space Opening
Due 30 October 2002
Resolved 21 February 2003
Engineering
Issued 25 October 2001 Resolved
Emergency fuel shut off valves need to be placed in auxiliary fuel tanks._x001C_
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Lifesaving
Issued 25 October 2001 Resolved
Install sign for additional 6 L/Js.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Lifesaving
Issued 25 October 2001 Resolved
Provide appropriate L/J donning placard.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Lifesaving
Issued 17 October 2000 Resolved
Renew light for one adult PFD.
Condition: Unknown
Due 17 November 2000
Resolved 6 November 2000
Lifesaving
Issued 30 November 1999 Resolved
RENEW EXPIRED BATTERIES ON ALL LIFE JACKET LIGHTS.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Navigation
Issued 30 November 1999 Resolved
OBTAIN CURRENT COPY OF COAST GUARD LIGHT LIST.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Documentation
Issued 30 November 1999 Resolved
PROVIDE PROOF OF REQUIRED EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Lifesaving
Issued 23 October 1998 Resolved
Perform required drills in the presence of a Coast Guard marine inspector.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998 Resolved
Provide 3-6 ft. line with detachable clip for ring buoy water light.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998 Resolved
Provide retro reflective tape for ring buoy.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998 Resolved
Provide proper buoyant, UV resistant line for ring buoy.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Navigation
Issued 10 October 1997 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD FOR VHF RADIO.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Fire Fighting
Issued 10 October 1997 Resolved
COMPLETE SATISFACTORY 6-YEAR MAINTENANCE ON ALL PORTABLE DRY CHEMICAL EXTINGUISHERS.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Lifesaving
Issued 10 October 1997 Resolved
PROPERLY LABEL BOTH LIFEFLOATS WITH CAPACITY AND VESSEL NAME.
Condition: Unknown
Due 10 October 1997
Resolved 10 October 1997
Navigation
Issued 26 October 1995 Resolved
PROVE PROPER OPERATION OF SINGLE SIDEBAND RADIO. VESSEL RESTRICTED TO COASTWISE ROUTE UNTIL COMPLETED.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 26 October 1995 Resolved
PROVIDE BATTERY FOR AND PROVE PROPER OPERATION OF EPIRB. VESSEL RESTRICTEDTO COASTWISE ROUTE UNTIL COMPLETED.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Navigation
Issued 12 October 1994 Resolved
PRIOR TO OPERATING AT NIGHT, MAKE REPAIRS TO/ AND PROVE PROPER OPERATION OFPORT RUNNING LIGHT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 2 ADDITIONAL WATERLIGHTS FORPERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 4 ADDITIONAL BATTERIES FOR PERSONAL FLOTATION DEVICE WATERLIGHTS.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Construction/Loadline
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF BILGE PUMPS.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Engineering
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF MAIN PROPULSION ENGINES.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Navigation
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ELECTRONICNAVIGATION EQUIPMENT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE APPROVED WEAK LINK FOR LIFE FLOAT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 12 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 30 METERS (100 FEET) OF ULTRA-VIOLET LIGHT RESISTANT PAINTER FOR LIFE FLOATS HAVING A BREAKING STRENGTH OF 6.7 KN (1500 LBS).
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Documentation
Issued 25 October 1993 Resolved
SHOW PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR PART 16 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Documentation
Issued 2 March 1992 Resolved
SUBMIT SKETCH FOR MSD BEFORE INSTALLING. SHOW PIPELINES, VALVES, VENTS_x001C_ AND TANK CAPACITY.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Accommodation/Occupational Safety
Issued 2 March 1992 Resolved
INSTALL CG APPROVED MSD FOR BOTH TOILETS. OVERBOARD VALVES SHALL BE KEPT_x001C_ CLOSED WHENEVER IN PORT AND WITHIN 3 NM OFFSHORE. POST PLACARD BY EACH VALVE INDICATING "CLOSE IN U.S. WATERS".
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Documentation
Issued 2 March 1992 Resolved
OBTAIN CURRENT COPY OF U.S. COAST PILOT AND SUBCHAPTER T.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Navigation
Issued 5 March 1991 Resolved
PROVIDE SINGLE SIDE BAND RADIO. VESSEL'S ROUTE IS RESTRICTED TO_x001C_ COASTWISE UNTIL RADIO IS PROVIDED.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Construction/Loadline
Issued 1 November 1990 Resolved
MAKE ENGINE ROOM HATCHES WATERTIGHT.
Condition: Unknown
Due 1 November 1990
Resolved 1 November 1990
Lifesaving
Issued 8 March 1990 Resolved
PROVIDE ONE (1) ADDITIONAL PFD LIGHT FOR ADULT PFD.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Engineering
Issued 8 March 1990 Resolved
REPLACE PETCOCK IN STBD FUEL FILTER WITH PLUG.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
PROVIDE FASTENING DEVICES FOR ENGINE ROOM HATCH COVERS.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Lifesaving
Issued 8 March 1990 Resolved
PROVIDE SIX (6) RED FLARES.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Lifesaving
Issued 10 March 1987 Resolved
ONE OF THE PFD WATERLIGHTS WAS NOT OPERATIONAL, MUST BE REPLACED.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Lifesaving
Issued 10 March 1987 Resolved
THREE OF THE FOUR LIFE FLOAT PADDLES WERE NOT ACCEPTABLE, FOUR ACCEPTABLE PADDLES MUST BE PROVIDED.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Navigation
Issued 10 March 1987 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Lifesaving
Issued 10 March 1987 Resolved
LINE ATTACHING LIFE FLOATS TO FLOAT-FREE LINK MUST BE RENEWED.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Fire Fighting
Issued 10 April 1986 Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER FOR ENGINE ROOM/GALLEY PROTECTION FOR A TOTAL OF 2 B-IIS.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.