ATLANTIS

ATLANTIS is a 1998 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in June 2026, along with 28 deficiencies, 1 operational control and 1 casualty investigation in 2007.

Records from 2007 to 2026. Most recent: inspection, 8 June 2026.

Built
1998
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK2544
471258
Flag
UNITED STATES
Maury page id
psix-471258

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)93.9 ft × 25.0 ft × 10.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)93.9 ft × 25.0 ft × 10.0 ft
ITC tonnagegross 206 / net 89
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Dead Weight, Ton
206 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
89 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

8 June 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8378563
21 January 2026 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8305204
18 December 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8285323
11 June 2025 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8157425
29 November 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8040435
22 May 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7916636
30 October 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7815405
28 August 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7780452
10 May 2023 MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7685041
13 June 2022 Deficiency Check · MTSA Verification · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7475933
29 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7352021
16 September 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7313924
22 September 2020 MTSA Verification · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7063089
21 November 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6860228
27 July 2019 Type not recorded
No type recorded · Station Cape May · USCG East District (CGD-E) · Activity 6779472
8 May 2019 Deficiency Check · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6679865
6 June 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6167294
1 March 2017 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6167528
10 January 2017 Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6068520
6 December 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6053277

Deficiency record · 28

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 June 2025 Resolved
At each inspection the operator should have the vessel ready for inspection if its fore protection equipment, including the following: Operation of fire main system. Vessel had hole in fire main piping on discharge side of engine room. 46CFR115.810 (a)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 13 June 2025
Resolution: MI Inspected all welds and witnessed operational test of fire mains. repairs are satisfactory and operational test of fire main was sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 May 2023 Resolved
Seal bulkhead penetrations between engine room and laz. 46 CFR 116.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 18 May 2023
Resolution: Owner sent photos of sealed penetrations.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 June 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated on the vessel's stability letter, the maximum number of passengers allowed on the upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Was was missing sign indicating max. passengers allowed on upper deck. Install sign indicating max. allowable passengers (188). 46 CFR 122.602(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 5 July 2022
Resolution: Upper Deck Marked
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 14 June 2022 Resolved
Each survival craft must be: (1) secured to the vessel by a painter with a float free link. Vessel's painter line is connected to the life floats line with a loose bowline. Properly secure this connection.46 CFR 117.130(a)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 4 August 2022
Resolution: Photos of a new spliced line attached to the painter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2022 Resolved
Placards containing instructions for the donning and use of the life jackets onboard the vessel must be posted..Vessel does not have the correct placards for the type of life jacket carried on board, replace with correct type. 46 CFR 122.516.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2022
Resolved 4 August 2022
Resolution: Posted and apart of orientation video
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 June 2022 Resolved
Vessel has not had fixed fire detection system serviced since its installation. Conduct servicing and provide report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 July 2022
Resolution: Servicing report 19 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 September 2021 Resolved
Exercises must be conducted at least once each calendar year, with no more than 18 months between exercises. Vessel is missing required annual exercise.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 26 October 2021
Resolution: annual security exercise completed.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 23 September 2020 Resolved
The fire control plan (FCP) must show escape routes, areas of refuge, embarkation stations, the location of fire protection and emergency equipment, compartment titles, hazard classification of accommodation and service spaces, and structual protection boundaries. Vessels FCP is missing a significant amount of required information. Vessel is to update the FCP to the satisfaction of an attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 9 November 2020
Resolution: Provided updated FCP
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2020 Resolved
Vessel's current emergency evacuation plan (EEP) is displaying incorrect information. The EEP must be updated to display the current layout of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 2 November 2020
Resolution: Plan updated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 May 2019 Resolved
Make watertight through fittings in #3, 4, 5, and lazarette bulkheads.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 26 June 2019
Resolution: Vessel added fire retardant spray foam in fittings in #3, 4, 5, and lazarette bulkheads.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2019 Resolved
Install chaffing material around electrical wiring in #3 compartment port side framing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 26 June 2019
Resolution: Vessel installed chaffing material around electrical wiring in #3 compartment port side framing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2019 Resolved
Make air compressor wire connection permanent.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 26 June 2019
Resolution: Vessel made air compressor wire connection permanent.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 May 2019 Resolved
Obtain 02 new lifefloat paddles and label with ship's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 26 June 2019
Resolution: Vessel obtained 2 new life float paddles.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2018 Resolved
Install type approved fire detection panel
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 November 2019
Resolution: Cleared during DD inspection. MI believes that this was cleared w/in the time frame but was erroneously left unresolved in MISLE.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2018 Resolved
Install UL489 breaker for new 12 VDC panel in pilot house
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: UL 489 breakers installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2018 Resolved
Prove proper operation of bilge suctions for compartments 2-6
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: All compartment bilge suctions have been tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2018 Resolved
Prove proper operation of electric bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Proper operation of electric bilge pump was verified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2018 Resolved
Provide vessel with a fire axe
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Fire axe on board.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2018 Resolved
Remove dead end wiring in void #3 & #4
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Dead end wiring removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 May 2018 Resolved
Replace port side lazarette hatch gasket
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2018
Resolution: Hatch gasket renewed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 May 2018 Resolved
Crop and renew crack in main deck, stbd side
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 21 November 2019
Resolution: Cleared during DD inspection. MI believes that this was cleared w/in the time frame but was erroneously left unresolved in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 May 2018 Resolved
Re-stencil person capacity on 03 lifefloats, as discussed
Action required: 10 - Deficiency Rectified
Resolved 9 May 2018
Resolution: Person capacity stenciled on lifefloats
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 May 2018 Resolved
Secure paddles to lifefloats with lanyard, to bottom row of floats (03), as discussed
Action required: 10 - Deficiency Rectified
Resolved 9 May 2018
Resolution: Paddles secured
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2018 Resolved
Label lifejacket boxes on main deck with contents, as marked
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2018
Resolution: Lifejacket storage properly marked
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2018 Resolved
Repair cracked welds in void #2 between frame 7-9, stbd side, IWO longitudinal stiffener and round bar
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2018
Resolution: Welds repaired
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2018 Resolved
Repair cracked weld in #4 void IWO overhead longitudinal outboard of fuel tank stbd side
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2018
Resolution: Welds repaired
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 May 2018 Resolved
Make the following bulkhead penetrations watertight: void #3 aft bulkhead port side, void #4 aft bulkhead port side, and lazarette forward bulkhead stbd side (x2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2018
Resolution: Bulkhead penetration watertight
Construction/Loadline › Hull › Bottom Plating
Issued 6 December 2016 Resolved
The vessel has been out of service for an extended period of time. Wastage was noted during the last drydock (which was not completed and no credit was granted). The vessel must complete a full drydock exam and a full renewal inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2017
Resolution: Vessel sold. Deficiency cleared for administrative purposes; special note added instead.

Casualty record · 1

3 August 2007Routine · role: Involved in a Marine Casualty · activity 3020598
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.