MAURY USCG vessel records Sign in
← All vessels

CAP GEORGES

CAP GEORGES is a 1997 tank ship. The Coast Guard has recorded 20 inspections since 2001, most recently in April 2017, along with 11 deficiencies and 4 operational controls.

Records from 2001 to 2017. Most recent: inspection, 19 April 2017.

Built
1997
Last inspected
19 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9128283 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
471281
Flag
GREECE
—
Maury page id
psix-471281

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2001–2017)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46543 - Regulatory (Subpart C or D), Net Ton
146652 - Dead Weight, Ton
171553 - Displacement, Ton
81148 - Convention (Subpart B), Gross Ton
81148 - Regulatory (Subpart C or D), Gross Ton
46543 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

19 April 2017 COE-Dockside · COE-Administrative
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6128352
17 August 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5971330
13 June 2016 COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5905990
12 May 2016 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5875646
28 August 2015 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5222453
2 August 2014 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4932310
2 August 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4941598
1 August 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4941204
25 June 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3246158
7 August 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2738463
21 July 2006 ISPS III Exam · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2720711
5 August 2005 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2452015
5 January 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2278778
19 July 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2138612
8 November 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1702604
8 November 2002 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1702627
26 July 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 756295
25 July 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 200333
25 July 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 292284
25 July 2001 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382369

Deficiency record · 11

Operations/Management › Pollution › Control of Garbage
Issued 25 June 2008 Resolved
2120; Mixed Garbage was found in all containers in the Crew / Officer pantries, which included cigarette butts. We were told smoking was only allowed in the Officer and Crew lounges. The crew could not explain how the cigarette butts got there. The 2/E said they only burned sludge and paper in the incinerator, however we found gasket material and other items.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2008
Resolved 17 August 2009
Resolution: GARBAGE WAS SEPARATED AND LABELED.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 June 2008 Resolved
0330; The sewage treatment plant is not being maintained as per the manufacturers requirements. Daily, weekly, semi-annual and annual test are not being carried out and the crew has not been checking the chlorine test as required.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2008
Resolved 17 August 2009
Resolution: DAILY, WEEKLY, SEMI-ANNUAL, AND ANNUAL TESTS ARE BEING CARRIED OUT AND THE CREW HAS BEEN CHECKING THE CHLORINE TEST AS REQUIRED.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 25 June 2008 Resolved
0950; There are three different types of electrical matting around the distribution panels. There isn't any documentation on board that states any of them meet any type of safety or voltage requirements. The company needs to provide documentation that the electrical matting meets the safety requirements as outlined in SOLAS.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2008
Resolved 17 August 2009
Resolution: RECEICVED DOCUMENTATION REGARDING ELECTRICAL MATTING MEETING SAFETY REQUIREMENTS AS OUTLINED IN SOLAS.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 25 June 2008 Resolved
1399; There is some hydraulic leakage on the forward mooring winch motors located in the Bos'n store. No action has been taken by the crew to repair these and no action has been taken to clean up the oil creating a fire / safety and potential pollution hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: The oil was removed and the engineers were working on finding and correcting the leaks.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 25 June 2008 Resolved
1899; At the base of #1 Blower fan housing unit there are cracks on each side. One is approximately 10cm long and the other is 3cm long. Repairs have been made before to these areas. Class must address this prior to the vessels return from overseas.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 17 August 2009
Resolution: RECEIVED CLASS REPORT STATING THE DEFICIENCY WAS EXAMINED AND REPAIRED TO SATISFACTION.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 25 June 2008 Resolved
1400; Above the doors leading into the Oil Purifier Room there are cracks in the upper right and left-hand corners. No one has addressed there or make any attempts to report them to the company or Class. Class must inspect this prior to the vessels return from an overseas port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 17 August 2009
Resolution: RECEIVED THE CLASS REPORT STATING THE FRACTURES ABOVE THE PURIFIER ROOM DOORS WERE EXAMINED AND REPAIRED TO SATISFACTION.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 25 June 2008 Resolved
2535; The ship's bunker and cargo transfer procedures did not meet the requirements of the Code of Federal Regulations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: Explained to the [name withheld] and Chief Engineer the problems with the Companies O. T. P. and our requirements. Gave the Captain sample copies of both to be followed in the future.
Deck/Cargo › Inert Gas System › IGG Isolating Valve
Issued 25 June 2008 Resolved
1800; While at anchorage the ship was taking on bunker and stores. Due to the lack of personnel available we were unable to test the IGS alarms or Cargo pumps emergency stops. Test would have done would have been simulated failures by removing the wires causing a break in the electrical circuit. Captain was informed that before cargo ops he must have USCG conduct test of systems.
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 17 August 2009
Resolution: SUCCESSFULLY CONDUCTED CARGO PUMP EMERGENCY STOPS.
Lifesaving › Launching Appliances › Davit
Issued 25 June 2008 Resolved
0610; The port aft lifeboat limit switch is not in alignment with the davit. It does not come in contact with the davit to cause it to stop. Fortunately the one forward worked. In addition one of the sprinkler heads on the starboard lifeboat is broken. Class needs to inspect both of these, LSA 4.9 and LSA 6.1.10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2008
Resolved 17 August 2009
Resolution: RECEIVED CLASS REPORT ATTESTING TO PROPER REPAIRS ON BOTH LIMIT SWITCH AND SPRINKLER HEAD.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 June 2008 Resolved
2540; 50% of the crew could not put on their Immersion suits in the time allowed under LSA Code 2.3.1.1.1. Some of the crew are larger than the suits provided. During the fire drill we had one of he crewmembers from the first aid squad lie down in the [name withheld] stretcher. The other members were to secure him for transfer to the hospital. They filed to properly secure him for transfer, LSA 2.3
Action required: 705 - Other - as specified
Due 25 June 2008
Resolved 25 June 2008
Resolution: Discussed these items with the [name withheld] and [name withheld] action must be taken by the company to provide suits of proper size and more training needs to be conducted with use of the stretcher.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 July 2006 Resolved
Tank overfill alarm for 2 stbd had delayed operation, alarming after 2 min. All other alarms activated within 15 seconds of activation allowing for timely response. 46 CFR 39.20-7
Action required: 705 - Other - as specified
Due 21 August 2006
Resolved 7 August 2006
Resolution: Number 2 stbd overfill alarm tested. Audible and visual alarm goes off within 15 seconds.

Ownership record