NEW EASY RIDER

NEW EASY RIDER is a 1972 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2025, along with 22 deficiencies, 3 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2021.

Records from 2016 to 2025. Most recent: inspection, 8 April 2025.

Built
1972
Last inspected
8 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2025
…with no type recorded1
Operational controls 1 with no removal date recorded
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC4782
Flag
UNITED STATES
Maury page id
psix-47132

Documentation record

Registered dimensions (L × B × D)48.5 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 35 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

8 April 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100715
19 March 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8094094
4 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7889854
27 March 2023 Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7659157
21 March 2023 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7650754
16 March 2023 Simplified Stability Test · Plan Review "T" Boat · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7652002
15 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609798
12 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7429082
17 March 2021 Annual Inspection · Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7193742
20 January 2021 Damage Survey · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7129488
4 January 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7119578
3 January 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7121214
30 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6933384
13 February 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6922736
10 July 2019 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6744468
15 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6662600
12 February 2019 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6628359
5 April 2018 Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6385187
16 March 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6373215
8 March 2018 Drydock Exam
Physical examination · USCG Southwest District (dpw) · USCG Southwest District (CGD-SW) · Activity 6370422
22 March 2017 Plan Review "T" Boat · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6109626
4 March 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5826738
22 January 2016 Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5801712

Deficiency record · 22

03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 April 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck. The window by the operation station STBD side and 03 holes in operation cabin area need to be made weather tight.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 10 June 2024
Resolution: Recieved photo of deficiency correction.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 April 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of the condition of the superstructure. Apply temporary FRP repair to STBD side bulkhead on weather deck to the satisfaction of the marine inspector, and submit repair proposal prior to next credit dry dock.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 10 June 2024
Resolution: Recieved photo of temp patch until repair can be completed at next scheduled drydock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. During operational test of vessel’s clean agent system, generator did not automatically shut down. Rectify deficiency through approved servicing facility to satisfaction of attending Marine Inspector. 46 CFR 181.420 (a) (3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
Resolution: Attended vessel to witness deficiency corrections. Conducted test, gernerator shutdown as required.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2023 Resolved
Each halocarbon cylinder forming part of a clean agent fire extinguishing system must be: (1) Retested at least once every 12 years and before recharging if it has been discharged and more than five years have elapsed since the last test; or (2) As an alternative, a cylinder conforming to the requirements of 49 CFR 180.209 (g) may be given the complete external visual inspection in lieu of hydrostatic testing provided for by that section. HFC-227 cylinder is due for 12-year hydrostatic test. Provide servicing records to indicate cylinder was properly hydro-statically tested to attending Marine Inspector. 46 CFR 16.401 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
Resolution: Attended vessel to witness deficiency corrections. Vessel provided documentation of proper servicing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 21 March 2023 Resolved
Except as provided in paragraph (e) of this section, a weathertight door with permanent watertight coamings that comply with the height requirements in table 171.124(d) must be provided for each opening located in a deck house or companionway that— (1) Gives access into the hull; and (2) Is located in— (i) A cockpit; (ii) A well; or (iii) An exposed location on a flush deck vessel. Table 171.124(d) Route: Exposed or partially protected. Height of coaming: 6 inches. Vessel to repair/replace engine room ventilation intakes to comply with height listed requirements, to the satisfaction of the Marine Inspector. 46 CFR 171.124(d) "OLD S"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
Resolution: Attended vessel to witness deficiency corrections. Vessel corrected ventilation intakes to be at least 6 inches above deck.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 March 2023 Resolved
Each EAP education program must include at least the following elements: display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer’s policy regarding drug and alcohol use in the workplace. Missing display of a hot-line number for crewmember assistance. Provide means to display hot-line number visible to crewmembers. 46 CFR 16.401 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
Resolution: Attended vessel to witness deficiency corrections. Vessel had required phone number/info posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 March 2023 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessel’s fixed power pump requires minimum pumping capacity of 10 Gallons Per Minute. Pump is of unknown bilge GPM capacity. Provide information identifying bilge pump capacity to satisfaction of attending Marine Inspector. 46 CFR 182.25-10 “OLD T”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2023
Resolution: Attended vessel to witness deficiency corrections. Vessel provided documentation of rated GPM for bilge pump.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessel that is operating on a Coastwise or Oceans route must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. The vessel is limited to a Limited Coastwise route until the installation of an interconnected fire detection system. 46 CFR 181.405(c)
Action required: 705 - Other - as specified
Resolved 4 April 2023
Resolution: Attending Marine Inspector verified the installation and operation of the fire detectors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 December 2022 Resolved
On a vessel that is operating on a Coastwise or Oceans route, flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel operator to provide information regarding the presence of such items onboard the vessel to a MI. 46 CFR 185.364
Action required: 705 - Other - as specified
Resolved 4 April 2023
Resolution: Attending Marine Inspector verified the vessel policy of no charging of personal devices for passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2021 Resolved
Where flexible nonmettalic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Fuel hoses did not meet the SAE J-1942 requirement. Replace fuel hoses with approved type. 46CFR182.720(e)
Action required: 705 - Other - as specified
Resolved 11 May 2021
Resolution: Operator installed fuel lines that meet SAE J-1942 requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 March 2021 Resolved
Flexibel hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. Fuel lines penetrated bulkhead from lazarette to engine room. Install proper through bulkhead fittings. 46CFR182(e)(3)(ii)
Action required: 705 - Other - as specified
Resolved 11 May 2021
Resolution: Operator installed proper fittings for the fuel lines to run through the forward bulkhead in the laz.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 January 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Determine cause of vessel's sinking and repair to original specifications. Dry dock inspection required prior to no sail being lifted. 46CFR177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2021
Resolution: Cause was determined to be an ineffective lazarette hatch which has been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 January 2021 Resolved
Stability information is required on certain vessels of this section. Enough stability information, including stability calculations and assumptions made to use them, must be provided to allow the master to be able to determine operating guidelines, loading restrictions, and ensure compliance with the applicable intact and damage stability regulations of this chapter. Vessel does not allow for carriage of cargo on its stability letter. Prior to carriage of cargo vessel must undergo stability test in order to add cargo to the stability letter. 46CFR178.210
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2022
Resolution: Amended COI to add Commercial fisheries within the limits of the stability letter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2020 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3' in length, but not more than 6' in length, securing the waterlight around the body of the buoy. Floating waterlight was clipped to grabline. (fixed on spot) 46CFR 180.70(d)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 March 2020
Resolved 30 March 2020
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 April 2019 Resolved
The vessel's Communications Act Radiotelephony Certificate expired in February 2018. The vessel must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. Schedule inspection with FCC-licensed technician, and provide a copy of the updated certificate to the satisfaction of the Marine Inspector. 47CFR80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 26 April 2019
Resolution: Recieved photograph of up-to-date radiotelephony certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2019 Resolved
Each ring life buoy must be marked with Type II retro reflective material. The retro reflective material on the vessel's ring life buoy was worn. Replace the retro reflective tape to the satisfaction of the Marine Inspector. 46CFR185.604(i)
Action required: 10 - Deficiency Rectified
Due 15 April 2019
Resolved 15 April 2019
Resolution: Retro reflective tape renewed to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 April 2019 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release unit for the vessel's IBA was not labeled. Provide HRU service records,and label HRU to the satisfaction of the Marine Inspector. 46CFR185.740(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 April 2019
Resolved 15 April 2019
Resolution: Hydrostatic Release Unit service records provided to MI, and HRU labeled with expiration date to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2019 Resolved
The general construction of the vessel shall be such as to minimize fire hazards. The bulkhead separating the Engine Room from the Lazarette space is not vapor tight. Restore vapor tight bulkhead to the satisfaction of the Marine Inspector. 46 CFR 177.10-5(a) "OLD T"
Action required: 10 - Deficiency Rectified
Due 15 April 2019
Resolved 15 April 2019
Resolution: Vapor barrier repaired to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2019 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across the terminals. The battery box in the Engine Room did not have a protective cover for the terminals. Protect battery terminals to the satisfaction of the Marine Inspector. 46 CFR 183.05-20 (a) "OLD T"
Action required: 10 - Deficiency Rectified
Due 15 April 2019
Resolved 15 April 2019
Resolution: Protective cover for batteries installed to the satisfaction of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2018 Resolved
Conduct COI exam prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2018
Resolution: COI exam completed.
Engineering › Generator (propulsion-electric) › Wiring
Issued 22 March 2017 Resolved
Vessel shall provide approved plans for newly installed generator. Vessel shall not operate generator when carrying passengers for hire until such plans are recieved.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 9 January 2018
Resolution: Plans were submitted and approved by MSC (Project No. P020934), and installations were verified IAW 46 CFR 177.202.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 March 2016 Resolved
Repair navigation lights such that the masthead light and the stern light are operational and IAW International and Inland Navigation Rules. 46CFR183.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 11 March 2016
Resolution: Vessel provided pictures of operational nav lights.

Casualty record · 1

3 January 2021Routine · role: Involved in a Marine Casualty · activity 7121214
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.