JIB VI

JIB VI is a 1972 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1985, most recently in April 2026, along with 107 deficiencies and 2 casualty investigations between 2002 and 2012.

Records from 1985 to 2026. Most recent: inspection, 28 April 2026.

Built
1972
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9324
Flag
UNITED STATES
367100720
Maury page id
psix-47137

Inspections, by type

…with no type recorded9
Years with a record 39 calendar years (1985–2026)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.8 ft × 22.8 ft × 6.7 ft
Registered tonnagegross 80 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLIKIN CRAFT INC · BEAUFORT · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9324MMSI 367100720 · active · compulsorily equipped · granted 28 April 2026, expires 21 March 2036
WYZ7116MMSI not assigned · expired · compulsorily equipped · granted 10 March 1997, cancelled 3 June 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

28 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357648
30 March 2026 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8334373
25 April 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8118038
3 April 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8104325
30 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903571
25 November 2023 Type not recorded
No type recorded · Station Fire Island · USCG Northeast District (CGD-NE) · Activity 7829510
3 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7663399
21 March 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7646805
15 March 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7403279
13 May 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7265527
12 April 2021 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7173364
16 June 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6980320
14 June 2020 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6978424
3 June 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6967605
7 April 2020 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6936379
10 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6681295
15 March 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6642008
23 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488423
28 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379714
6 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361823
13 March 2017 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6103552
31 March 2016 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5844715
21 March 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837288
13 March 2014 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4815669
22 February 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4248079
9 March 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3692001
12 March 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3432110
1 December 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3371765
12 March 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3162767
28 November 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3105693
13 March 2007 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2886875
7 March 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2597047
17 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2535293
8 March 2005 Annual Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2305250
5 March 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2018094
12 November 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1945423
7 March 2003 Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1753452
2 May 2002 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1667187
6 March 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1491438
6 December 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1426694
12 March 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1406881
3 July 2000 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1449342
1 March 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1427787
19 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1037008
3 March 1999 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 799691
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1124545
13 November 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1415102
22 September 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 800870
3 March 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1118393
31 July 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 781475
4 March 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1094087
14 January 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104571
17 September 1996 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 827470
16 February 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880757
16 November 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185967
15 November 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184334
3 May 1995 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869695
13 March 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827677
1 December 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134682
7 March 1994 Drydock Extension · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854946
4 March 1994 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863462
28 February 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165693
25 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837606
17 November 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143196
28 February 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946622
5 December 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264987
8 July 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253516
1 March 1991 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910660
3 December 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905552
1 July 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242875
6 March 1990 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907084
2 March 1989 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889852
22 February 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337608
7 December 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005421
23 February 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002562
26 March 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997199
6 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991833
25 February 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991831
25 February 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299544
27 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285672

Deficiency record · 107

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2025 Resolved
Renew alcohol test swabs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 5 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 April 2025 Resolved
Renew batter in life float light.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 5 May 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2025 Resolved
Fixed CO2 was found with loose supply hose from servicing. Tightened and cleared on the spot.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 25 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2025 Resolved
Double hose clam bilge suction stbd side.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 5 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2025 Resolved
Install new retro reflective material on life ring.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 5 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2025 Resolved
Mark emergency fuel shut offs for gen set in freezer space.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2025
Resolved 5 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2025 Resolved
Install outlet cover for light switch bottom of ladder in freezer space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 5 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 April 2025 Resolved
Install retention lanyards for deck scuttles.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 5 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024 Resolved
Condemned 8 life jackets. Decreased passenger carrying capacity by 8.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2024
Resolved 30 April 2024
Resolution: Replaced lifejackets with new.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2023 Resolved
Fixed system was out for servicing. Issued requirement to install.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2023
Resolved 27 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 21 March 2023 Resolved
Renew hydrostatic release for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2023
Resolved 27 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2023 Resolved
Double up hose clmaps on port & stbd MDE.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 27 April 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2023 Resolved
Foward mast headlight was inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2023
Resolved 27 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2020 Resolved
Reconfigure removeable railings as discussed to secure railings as well as be openable as designed and accepted for recovery of a person in the water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 30 June 2020
Resolution: Attended vessel to inspect railing reconfiguration. All SAT
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 3 June 2020 Resolved
Oily water mixture in the aft steering space and tank void. Pump out and clean bilges IAW vessel's stability letter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2020
Resolved 3 June 2020
Resolution: Bilges pumped out and cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 June 2020 Resolved
Repaint life floats and reinstall retro-reflective to conform with Q specifications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2020
Resolved 3 July 2020
Resolution: Life Floats Painted, restencilled, and retro-reflective tape re-installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2020 Resolved
Flexible hoses used for fuel lines going to the secondary fuel filter were painted and unable to be inspected to determine compliance with SAE J-1942 or equilivent. Replace painted fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2020
Resolved 3 July 2020
Resolution: Offshore diesel marine replaced machined fuel hoses with SAE J1942 equilevents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2020 Resolved
Fire pump was disassembled after sucking in entangled fishing line from the r/w suction. Prove proper operation of the vessels fire main prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2020
Resolved 3 June 2020
Resolution: Fire pump cleared and reassembled. Video proof of the fire pump operational sent to MSD Coram.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 March 2019 Resolved
No vent closures installed to the E.R., protected by a fixed CO2 system
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: Guards installed on MDE and Generator.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 March 2019 Resolved
No closures installed to E.R. openings where the space is protected by CO2.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: Engine room Vent closures installed
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 March 2019 Resolved
Battery for EPIRB found expired since Dec 2018. Restricted Vessel's route to W/I 3nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: New EPIRB purchased and registered. Updated vessel's details.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 March 2018 Resolved
Conduct U/W sea trials following upcoming Credit DD to include emergency drills with CG in attendance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2018
Resolved 23 July 2018
Resolution: O/O conducted u/w drills
Documentation › Markings/Placards › Capacity Marking
Issued 6 March 2018 Resolved
Relabel upper deck capacity
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 July 2018
Resolution: O/O relabeled deck
Lifesaving › Lifefloat › Paddle
Issued 6 March 2018 Resolved
Relabel L/F paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 July 2018
Resolution: O/O properly stenciled paddles
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 March 2018 Resolved
Repair or replace stbd emergency fuel shut off valve reach rod (bent)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 23 July 2018
Resolution: O/O preoperly installed reach rod
Construction/Loadline › Hull › Transverse Frame
Issued 31 March 2016 Resolved
Remove and replace floor timber bolts, 8 in lazarette, 6 in crash compartment and bolt in 2nd frame forward of crash bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 31 March 2016 Resolved
Replace ball valve servicing livewell pump starboard side engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2016
Construction/Loadline › Hull › Transverse Frame
Issued 31 March 2016 Resolved
Repair starboard side outboard drive shaft strut support board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 April 2016
Construction/Loadline › Hull › Bottom Plating
Issued 21 March 2016 Resolved
Complete credit Hull/ISE prior to carrying passengers.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 8 April 2016
Documentation › Certificates/Documents › FCC SSL
Issued 21 March 2016 Resolved
Provide copy of current FCC Station License. (showed valid on internet, but O/O didn't have a copy on board)
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 March 2016 Resolved
Clearly mark RLB w/vessels name.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Communications › Radio Communications › EPIRB
Issued 9 March 2010 Resolved
Provide hydrostatic release for EPIRB prior to sailing beyond 3nm from baseline.
Action required: 705 - Other - as specified
Resolved 19 March 2010
Communications › Radio Communications › EPIRB
Issued 9 March 2010 Resolved
Provide proof of EBIRB registration prior to sailing beyone 3nm from baseline.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 19 March 2010
Lifesaving › Lifebuoys › Serviceable
Issued 9 March 2010 Resolved
Provide new ring buoy.
Due 9 April 2010
Resolved 19 March 2010
Navigation › Piloting/Steering › Marine Charts
Issued 9 March 2010 Resolved
Provide chart for applicable area of operation
Due 9 April 2010
Resolved 19 March 2010
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 9 March 2010 Resolved
Provide updated pool membership report
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 9 March 2010 Resolved
Provide proof of MIS report submission.
Due 9 April 2010
Resolved 19 March 2010
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 9 March 2010 Resolved
Port generator, repair center injector oil leak.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 19 April 2010
Resolution: CORRECTED
Engineering › Fuel Oil Service System › Piping
Issued 9 March 2010 Resolved
Replace unapproved f/o supply piping/hoses as discussed to both generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 March 2010 Resolved
Conduct 12vdc electrical maintenance on all connections as discussed.
Due 9 April 2010
Resolved 19 March 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 March 2010 Resolved
Replace both m/e r/w suction hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 March 2010 Resolved
Repair fwd compt bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Engineering › Fuel Oil Service System › Valve
Issued 9 March 2010 Resolved
Repair and/or adjust all four emergency fuel reach rods as discussed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 March 2010 Resolved
Install metal wire hangars throughout engineering spaces.
Due 9 April 2010
Resolved 19 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 March 2010 Resolved
Conduct leak maintenance, repair, and adjustment to both m/e exhaust systems as discussed.
Due 13 May 2010
Resolved 27 April 2010
Resolution: New clamps fitted.
Communications › Radio Communications › EPIRB
Issued 12 March 2009 Resolved
Provide valid EPIRB registration with updated call sign. Route reduced to NMT 3NM from baseline.
Due 12 April 2009
Resolved 23 March 2009
Engineering › Bilge Water Management System › Piping
Issued 12 March 2009 Resolved
Remove PVC from bilge system to conform with 46 CFR 182.510.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2009
Resolved 23 March 2009
Lifesaving › Lifefloat › Serviceable
Issued 12 March 2009 Resolved
Make all lifefloats conform to 46CFR 160.027, regarding netting, platform, and paddles)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2009
Resolved 23 March 2009
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 1 December 2008 Resolved
Re-mark draft marks on hull. Make sure they are measured from the base line of the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 16 December 2008
Engineering › Bilge Water Management System › Valve
Issued 1 December 2008 Resolved
Renew all four bilge pump overboard discharge control valves at side planking penetrations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 8 April 2016
Resolution: replace valves
Construction/Loadline › Hull › Keel
Issued 1 December 2008 Resolved
Crop out worm borer damaged area at aft end of keel. Insert new wood and treat to prevent further infestation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 16 December 2008
Resolution: Approximately 1" deep dutchman 18'' long and 2" high fitted after worm damaged area cut out. Sealed in place with marine adhesive and mechanically fastened. Coated with anti-fouling paint & protected by worm shoe.
Electrical › Electric Supply System (service) › Cable
Issued 1 December 2008 Resolved
Renew power supply conductor to electric bilge pump in aft compartment. Insure conductors are protected from mechanical damage. Existing conductors were located at bottom of ladder and were stepped on causing the insullation to break down.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 16 December 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 December 2008 Resolved
P & S aft strut bearings R & R by O/O prior to arrival of inspector. All work completed satisfactorily.
Due 1 December 2008
Resolved 1 December 2008
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 12 March 2008 Resolved
Tighten shaft packing on port and stbd MDE.
Due 20 March 2008
Resolved 20 March 2008
Resolution: Tightened shaft packing on port and stbd MDE.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 March 2008 Resolved
Properly label all emergency fuel shut off valves.
Due 20 March 2008
Resolved 20 March 2008
Resolution: Properly labeled all emergency fuel shut off valves.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 March 2008 Resolved
Replace all expired meds in first aid kit with current products.
Due 20 March 2008
Resolved 20 March 2008
Resolution: Replaced all expired meds in first aid kit with current products.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 12 March 2008 Resolved
Provide current copy of Coast Gaurd Nav Rules and tide and current tables aboard vessel.
Due 20 March 2008
Resolved 20 March 2008
Resolution: Provided current copies of Coast Gaurd Nav Rules and tide and current tables aboard vessel.
Communications › Radio Communications › EPIRB
Issued 13 March 2007 Resolved
Vessel is limited to no more than 3 miles from shore until a working/registered EPIRB is installed. Vessel had EPIRB install but it was not working properly and O/O had sent it out for repair or replacement.
Condition: Unknown
Due 13 March 2007
Resolved 16 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 March 2006 Resolved
Replace first aid kit damaged by water.
Condition: Damaged By Earlier Event
Due 1 April 2006
Resolved 4 April 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 7 March 2006 Resolved
Replace water pump
Condition: Unknown
Due 1 April 2006
Resolved 4 April 2006
Engineering › Bilge Water Management System › Piping
Issued 7 March 2006 Resolved
Double hose clamp raw water intake for Genset
Condition: Placed in Improper Service
Due 1 April 2006
Resolved 4 April 2006
Communications › Radio Communications › EPIRB
Issued 8 March 2005 Resolved
Provide EPIRB hydrostatic release, until provided vessel is limited to 3 nautical miles from shore on a coastwise voyage.
Due 18 March 2005
Resolved 21 March 2005
Electrical › Electrical Distribution System (service)
Issued 5 March 2004 Resolved
Label generator breakers in the engineroom breaker panel. LEGACY COMPONENT DESC: Circuit Breaker
Due 5 March 2004
Resolved 9 March 2004
Engineering › Steering Gear System
Issued 5 March 2004 Resolved
Tighten steering bearing support and linkage clamp at the chain drive interface prior to carrying passengers. LEGACY COMPONENT DESC: Linkage
Due 5 March 2004
Resolved 9 March 2004
Engineering › Bilge Water Management System
Issued 5 March 2004 Resolved
Provide strainer for bilge suction in the aft fuel compartment prior to carrying passengers. LEGACY COMPONENT DESC: Strainer
Due 5 March 2004
Resolved 9 March 2004
Electrical › Electric Generation Source (service)
Issued 7 March 2003 Resolved
Generator would only run for one minute, second generator would not run. Repair/renew LEGACY COMPONENT DESC: Power Requirement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2003
Resolved 19 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 March 2003 Resolved
Loss of exhaust cooling alarm not able to test. Conduct test LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2003
Resolved 19 March 2003
Fire Fighting › Fire Main
Issued 7 March 2003 Resolved
Hose installed for fire main. Renew with metalic pipe and conduct operation/hydo test. LEGACY COMPONENT DESC: Material
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2003
Resolved 19 March 2003
Fire Fighting › Fixed Fire Detection System
Issued 7 March 2003 Resolved
Aft sensor in engine room inop. Repair/renew. LEGACY COMPONENT DESC: Heat Detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2003
Resolved 19 March 2003
Personnel › Certificates/Documents/Licenses
Issued 6 March 2002 Resolved
Provide copy of master's license. LEGACY COMPONENT DESC: License, Master
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2002
Resolution: Current copy provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 March 2002 Resolved
Provide proof of enrollment in consortium for the operating season.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2002
Resolution: Copy of contract provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 March 2002 Resolved
Provide 6 year service for B1 extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2002
Resolution: New B1 purchased and mounted on bridge.
Communications › Radio Communications
Issued 6 March 2002 Resolved
Have EPIRB serviced. It activates when not supposed to. Vessel restricted to no farther than 3nm from shore until complete. LEGACY COMPONENT DESC: EPIRB
Due 8 April 2002
Resolved 29 May 2002
Resolution: EPIRB serviced by ACR Tehnologies.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 March 2002 Resolved
Provide aspirin and eyewash for first aid kit. Expired.
Due 8 April 2002
Resolved 18 March 2002
Resolution: New items purchased and placed into kit.
Communications › Alarms/Indicators
Issued 6 March 2002 Resolved
Provide lights for bilge high level alarms independent of auto bilge pumps. LEGACY COMPONENT DESC: High Water Alarm
Condition: Improper Installation
Due 8 April 2002
Resolved 29 May 2002
Resolution: New 5 alarm panel installed and tested,
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2002 Resolved
Install high level alarm in forepeak.
Due 8 April 2002
Resolved 18 March 2002
Resolution: Added float switch to in forpeak for bilge alarm.
Engineering › Fuel Oil Service System › Tank
Issued 6 March 2002 Resolved
Refasten ground wire for fuel tank.
Due 8 April 2002
Resolved 18 March 2002
Resolution: Ground wire refastened.
Fire Fighting
Issued 3 March 1999 Resolved
HYDRO/SERVICE 3 B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 20 March 1999
Resolved 9 March 1999
Lifesaving
Issued 3 March 1999 Resolved
REPLACE WEAK LINK ON BUOYANT APPARATUS
Condition: Unknown
Due 20 March 1999
Resolved 9 March 1999
Lifesaving
Issued 3 March 1999 Resolved
RENEW HYDRO RELEASE ON EPIRB.
Condition: Unknown
Due 20 March 1999
Resolved 9 March 1999
Lifesaving
Issued 4 March 1997 Resolved
PAINT, STENCIL, RENEW RETRO AND LINE ON 10 MAN B/A.
Condition: Unknown
Due 17 March 1997
Resolved 12 March 1997
Lifesaving
Issued 4 March 1997 Resolved
REPAIR LIFE RING.
Condition: Unknown
Due 17 March 1997
Resolved 12 March 1997
Lifesaving
Issued 4 March 1997 Resolved
PROVIDE 2 WORKING FLASHLIGHTS.
Condition: Unknown
Due 17 March 1997
Resolved 12 March 1997
Lifesaving
Issued 4 March 1997 Resolved
PROVIDE 8 NEW CHILD AND 62 NEW ADULT PFD'S WITH STENCIL AND RETRO.
Condition: Unknown
Due 17 March 1997
Resolved 12 March 1997
Construction/Loadline
Issued 17 September 1996 Resolved
MAKE PERMANENT REPAIRS TO PORT EXHAUST FLANGE AND WOOD AROUND FLANGE.
Condition: Unknown
Due 19 September 1996
Resolved 24 September 1996
Engineering
Issued 13 March 1995 Resolved
FILL FUEL TANK TO FULL CAPACITY FOR WORKING PRESSURE TEST.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Lifesaving
Issued 13 March 1995 Resolved
MOUNT MACHINERY GUARD ON FORWARD BELT OF SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 13 March 1995 Resolved
REPAIR COPPER FUEL LINE ON STBD NDE FROM FILTER TO ENGINE FUEL SHUT OFF VALVE (APPROX 8 FEET).
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Construction/Loadline
Issued 1 December 1994 Resolved
REPAIR DECK IWO AREAS MARKED DURING 01DEC94 DRYDOCKING.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Lifesaving
Issued 28 February 1994 Resolved
REINSTALL LIFEFLOATS AND PLACE RETROREFLECTIVE MATERIAL ON EACH AND SHALL NOT CARRY PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Construction/Loadline
Issued 28 February 1994 Resolved
CONDUCT UNDERWAY EXAMINE IN PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Accommodation/Occupational Safety
Issued 28 February 1994 Resolved
PROVE PROPER OPERATION OF MSD SYSTEM AND WASH BASINS.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Engineering
Issued 28 February 1994 Resolved
FREE ALL BILGE STRAINERS OF ICE AND SNOW, SHALL NOT CARRY PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Construction/Loadline
Issued 5 December 1991 Resolved
RENEWED SEA VALVE FOR SHIP SERVICE GENERATOR.
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Construction/Loadline
Issued 5 December 1991 Resolved
REPLACED SEVEN (7) FRAMES AND APPROXIMATELY TWO THIRDS OF THE BULWARK ON_x001C_ THE PORTSIDE.
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Accommodation/Occupational Safety
Issued 1 March 1991 Resolved
REPAIR LADDER TO FWD COMPARTMENT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Construction/Loadline
Issued 1 March 1991 Resolved
CAULK AND SEAL WATERTIGHT BHDS IN WAY OF BILGE PIPING AND MESE CHINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Construction/Loadline
Issued 1 March 1991 Resolved
FREE DOGS ON DECK HATCHES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Construction/Loadline
Issued 3 December 1990 Resolved
BULWALK FRAMES RENEWED ON PORT SIDE
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990 Resolved
APROX. 6 INCH OF SIDE SHELL PLANKING RENEWED ON STBD SIDE MIDSHIP. WASTED INWAY OF BUTT BLOCK.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Lifesaving
Issued 6 March 1990 Resolved
PROVIDE 4 ADULT PFD'S.
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Fire Fighting
Issued 6 March 1990 Resolved
HYDRO TEST BII CO2 W/ 1984
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Electrical
Issued 6 March 1990 Resolved
INSTALL A GROUND FAULT DETECTION SYSTEM ON GROUNDED NEUTRAL 120 VAC SY
Condition: Unknown
Due 6 March 1990
Resolved 6 March 1990
Electrical
Issued 23 February 1987 Resolved
PROVIDE COVER PLATE FOR ENGINEROOM LIGHT SWITCH ON FORWARD BULKHEAD.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Construction/Loadline
Issued 23 February 1987 Resolved
PROVIDE A SECURING CHAIN FOR THE AFT HATCH ON THE MAIN DECK.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Engineering
Issued 23 February 1987 Resolved
REPLACE FLEXIBLE FUEL LINES AND ASSORTED HOSE CLAMPS ON AUXILIARY GENERATORWITH THE PROPER WIRE REINFORCED FLAME SHIELDED HOSE AND CRIMP ON FITTINGS.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Electrical
Issued 23 February 1987 Resolved
PROVIDE METAL WIRE HANGERS WITH CHAFFING GEAR FOR WIRING ON OVERHEAD IN ENGINEROOM.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987

Casualty record · 2

2 May 2002Routine · role: Involved in a Marine Casualty · activity 1667187
29 October 2012Routine · role: Involved in a Marine Casualty · activity 4579237
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.