← All vessels
QUEEN OF HEARTS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named QUEEN OF HEARTS
QUEEN OF HEARTS is a 1972 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in April 2025, along with 60 deficiencies and 1 casualty investigation in 2014.
Records from 1985 to 2025. Most recent: inspection, 21 April 2025.
- Built
- 1972
- Last inspected
- 21 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 60 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2014
Identity
538660
WAN7839
47138
Flag
UNITED STATES
366735920
Maury page id
psix-47138
Inspections, by type
…with no type recorded10
Years with a record
35 calendar years (1985–2025)
The 79 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.5 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 34 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD · WESTPORT, WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHALF MOON BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ8740MMSI 366735920 · active · compulsorily equipped · granted 1 April 2026, expires 1 April 2036
WAN7839MMSI 366735920 · expired · compulsorily equipped · granted 12 May 2015, cancelled 30 August 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 79
21 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116128
12 February 2024
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7862359
5 February 2024
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7844698
13 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7665851
12 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608082
24 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7418119
16 March 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7412320
24 February 2022
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7389663
28 February 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147673
19 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6957675
11 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6924703
25 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914890
25 February 2019
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6622804
17 April 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6392883
22 February 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6359575
4 January 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332509
29 March 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112524
29 January 2016
Administrative Inspection · Annual Inspection · In-Service Inspection · Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5807485
4 October 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5000360
5 March 2014
COI Inspection · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4810066
1 December 2011
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4248493
14 December 2009
Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3648876
3 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437173
17 January 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3130453
6 December 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3105948
1 March 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2986001
28 March 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2607734
13 February 2006
Hull Examination · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2525678
10 January 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2266185
3 February 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1991804
12 December 2003
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1963446
25 November 2003
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1952152
24 March 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1762990
18 March 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1753716
7 May 2002
Simplified Stability Test · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1613716
11 April 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603622
29 March 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1599162
25 March 2002
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1597431
17 February 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1487186
3 December 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387227
24 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1077289
6 February 2001
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1452763
3 April 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1047566
20 January 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1045958
18 January 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1442939
6 December 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375985
1 March 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 799898
25 February 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 800433
25 January 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1427612
22 January 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805421
27 January 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375239
1 December 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774902
24 June 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 776755
27 January 1997
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1102812
30 January 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884262
3 January 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 877054
3 January 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 881580
30 January 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1161511
5 March 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 114424
31 January 1994
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162426
29 November 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847958
2 February 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144803
12 December 1991
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257615
6 February 1991
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 912037
6 August 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 914224
19 June 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1225374
5 March 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234476
1 February 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919909
22 February 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1198601
6 February 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032713
10 June 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 889706
16 February 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023742
2 July 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319473
23 June 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1317684
23 April 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007274
21 April 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1317026
16 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1289268
14 March 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978865
13 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1283018
Deficiency record · 60
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector (MI) identified dead end wires located inside the port side engine room ventilation port. Conduct repairs to the satisfaction of the MI.
46 CFR 183.200(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector identified dead end wires located on top of the wheelhouse, on the port side. Conduct repairs to the satisfaction of the MI.
46 CFR 183.200(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Marine Inspector identified a broken bonding wire on the bait tank pump overboard. Conduct repairs to the satisfaction of the MI.
46 CFR 183.372
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025
Resolved
Each life jacket carried on a vessel on oceans...route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Marine Inspector identified 4 inoperable lights on life jackets. Conduct repairs and inspect all on board life jackets to the satisfaction of the MI.
46 CFR 180.75
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Marine Inspector identified that one of the life float's waterlight was inoperable. Conduct repairs to the satisfaction of the MI.
46 CFR 180.175(a)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 April 2025
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Marine Inspector identified that all life float paddles were not properly lashed to the body of the life float. Conduct repairs to the satisfaction of the MI.
46 CFR 180.175 (f)(2)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2025
Resolved
Electrical equipment exposed to the weather must be watertight. Marine Inspector identified that the sternlight housing mount was cracked and missing a screw, inhibiting watertightness. Conduct repairs to the satisfaction of the MI.
46 CFR 183.210(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
Each...ring life buoy must be marked with Type II retroreflective material...The arrangement...must be as specified by IMO Resolution A.658(16). Marine Inspector identified that the retroreflective material on the ring life buoy was weathered and peeling. Conduct repairs to the satisfaction of the attending MI.
46 CFR 185.604(i)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
Each ring life buoy on a vessel must: (2) Be readily accessible;(3) Be stowed in a way that it can be rapidly cast loose. Marine Inspector assessed that the ring life buoy was not readily accessible. Re-locate to the satisfaction of the attending MI.
46 CFR 180.70(b)
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 21 April 2025
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Marine Inspector identified that fire fighting drills were not properly logged in the vessel log book.
46 CFR 185.524(d)
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 21 April 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Marine Inspector identified that abandon ship and man overboard drills were not properly logged in the vessel log book.
46 CFR 185.520(f)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets. Marine Inspector identified that the fire buckets exceeded 2.5 gallons. Conduct repairs to ensure that the buckets cannot exceed a water capacity above 2.5 gallons.
46 CFR 181.610
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 April 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. Engine Room FWD bulkhead has insufficient vapor tight boundary at both STBD and PORT side bulkhead penetrations near the overhead deck. Additionally, there are multiple existing fastener (screw) holes that require closing. Fill all bulkhead penetrations to achieve sufficient vapor barrier to satisfaction of Marine Inspector.
46 CFR 182.35-1 (a) OLD-T
Documentation › Certificates/Documents › FCC SSL
Issued 17 April 2018
Resolved
FCC Station License is expiered.
Lifesaving › Lifebuoys › Serviceable
Issued 17 April 2018
Resolved
Renew Life Ring (rope is deteriorated).
Lifesaving › Lifefloat › Float-free Link
Issued 28 March 2006
Resolved
Replace corroded weak link on lifefloats.
Engineering › Steering Gear System › Fastener
Issued 28 March 2006
Resolved
Secure properly loose nut on steering gear mount.
Engineering › Fuel Oil Service System › Piping
Issued 7 December 2005
Resolved
Modify flexible hose installation for the stbd engine fuel oil system to comply with 46 CFR 182.720(e).
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2005
Resolved
Remove expired medications from vessel.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 10 January 2005
Resolved
Repair leaks in shaft packing gland.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2005
Resolved
Install metal wire hangers to secure the wiring that runs over the engines.
Engineering › Fuel Oil Service System
Issued 25 November 2003
Resolved
Repair F/O leak on stbd MDE Racor filter swingball valve plumbing. LEGACY COMPONENT DESC: Piping
Engineering › Fuel Oil Service System
Issued 25 November 2003
Resolved
Repair F/O leak on port F/O tank supply valve. Bottom of tank in way of lazarette. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Structures
Issued 25 November 2003
Resolved
Treat E/R overhead framing furring condition port and stbd sides from E/R deck hatch 4 to 5 frames aft along outboard sides of E/R.
Lifesaving
Issued 18 March 2003
Resolved
Properly install life float waterlight lines, 2 lines are incorrect type, 2 lines are incorrect length.
Fire Fighting › Miscellaneous Items
Issued 18 March 2003
Resolved
Label fire buckets and attach lanyards.
Documentation › Certificates/Documents
Issued 18 March 2003
Resolved
Provide and properly post copy of stability letter on vessel. LEGACY COMPONENT DESC: Stability Letter
Stability
Issued 11 April 2002
Resolved
CONDUCT A NEW STABILITY TEST FOR EXPOSED WATERS CARRYING 45 PASSENGERS PRIOR TO 11JULY2002. UNTIL 11JULY2002 THIS VESSEL MAY CONTINUE VOYAGES TO CORDELL BANK AND THE FARALLON ISLANDS WITH PASSENGERS ON A LIMITED COASTWISE ROUTE.
Navigation › Piloting/Steering
Issued 11 April 2002
Resolved
Obtain a new chart(s) of large enough scale (to safely navigate and) to encompass all navigated areas of by the vessel that is up to date prior to 11May2002. Faxed proof of purchase to [phone withheld] will be accepted. LEGACY COMPONENT DESC: Marine Charts
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 11 April 2002
Resolved
Service (weigh) fixed extinguisher in engineroom.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 11 April 2002
Resolved
Recharge or remove extra B-II extinguisher from passenger compartment.
Lifesaving
Issued 18 January 2000
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB.
Documentation
Issued 25 January 1999
Resolved
PROVIDE VALID FCC RADIO OPERATOR PERMIT.
Documentation
Issued 25 January 1999
Resolved
PROVIDE COAST CUARD CERTIFICATE OF DOCUMENTATION WITH CORRECT ADDRESS FOR OWNER.
Electrical
Issued 3 January 1996
Resolved
REMOVE WIRE NUTS AND PROPERLY TERMINATE WIRING ON STBD ENG CLUTCH.
Electrical
Issued 3 January 1996
Resolved
FABRICATE AND INSTALL BATTERY BOX COVER FOR PORT BATTERY BOX IN ENGINE ROOM.
Engineering
Issued 3 January 1996
Resolved
MAKE PROPELLERS AVAILABLE FOR INSPECTION.
Construction/Loadline
Issued 30 January 1995
Resolved
CAP OR COMPLETE PIPING FOR BAIT TANK SUCTION LINE
Deck/Cargo
Issued 31 January 1994
Resolved
PROVIDE AT LEAST 210 FEET OF ANCHOR RODE (LARGER THAN 1/2" DIA LINE OR LARGER THAN 3/8" CHAIN, OR BOTH) TO SUPPLEMENT THE EXISTING 90 FEET ABOARD SO THAT THE TOTAL LENGTH OF ANCHOR RODE IS 300 FEET OR GREATER.
Accommodation/Occupational Safety
Issued 31 January 1994
Resolved
PROVIDE A SUITABLE INSECT SCREEN OVER THE FRESH WATER TANK VENT.
Engineering
Issued 1 February 1990
Resolved
REPLACE THE MISSING DRIVE BELT GUARDS ON BOTH MAIN ENGINES.
Engineering
Issued 1 February 1990
Resolved
REPLACE FLAME SCREENS ON BOTH FUEL TANK VENTS.
Engineering
Issued 6 February 1989
Resolved
INSTALL PROTECTION FOR TWO FUEL TANK REMOTE SHUTDOWNS.
Unknown
Issued 21 April 1987
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS
Unknown
Issued 21 April 1987
Resolved
HYDRO AIR RECEIVER FOR AIR HORN AND REPAIR HORN IF REQUIRED
Unknown
Issued 21 April 1987
Resolved
PROVIDE GLOBES/SHIELDS FOR 4 LIGHTS IN E/R & 2 LIGHTS IN FWD COMPARTMENT.
Unknown
Issued 21 April 1987
Resolved
REPAIR RING BUOY WATERLIGHT.
Unknown
Issued 21 April 1987
Resolved
REPAIR ANCHOR WINDLASS
Unknown
Issued 21 April 1987
Resolved
RESTENCIL BUOYANT APPARATUS.
Unknown
Issued 21 April 1987
Resolved
ATTACH WATERLIGHT TO BUOYANT APPARATUS.
Accommodation/Occupational Safety
Issued 14 March 1985
Resolved
PROVIDE LOCK FOR MSD VALVES.
Engineering
Issued 14 March 1985
Resolved
EXTEND ENGINE ROOM VENT TO BILGE COVER.
Engineering
Issued 14 March 1985
Resolved
CLEAN ENGINE ROOM BILGES.
Lifesaving
Issued 14 March 1985
Resolved
PROVIDE LIFE FLOATS WITH FLOAT LIGHTS.
Construction/Loadline
Issued 14 March 1985
Resolved
PROVIDE LAZERETTE HATCH CHAIN.
Accommodation/Occupational Safety
Issued 14 March 1985
Resolved
POST OPERATING INSTRUCTIONS FOR EACH TOILET.
Lifesaving
Issued 14 March 1985
Resolved
ATTACH LIFE RING FLOAT LIGHT.
Fire Fighting
Issued 14 March 1985
Resolved
SERVICE AT LEAST ONE B-I FIRE EXTINGUISHER AND REMOVE ALL EXTRA UNINSPECTEDFIRE EXTINGUISHERS.
Electrical
Issued 14 March 1985
Resolved
CRIMP WIRE CONNECTIONS IN BUNK ROOM AND ENGINE ROOM.
Electrical
Issued 14 March 1985
Resolved
COVER WIRE JUNCTION BOX IN BUNK ROOM.
Casualty record · 1
4 October 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5000360
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.