Records from 2014 to 2025. Most recent: inspection, 21 April 2025.
Documentation record
Registered dimensions (L × B × D)48.5 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 34 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD · WESTPORT, WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHALF MOON BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
21 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116128
12 February 2024
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7862359
5 February 2024
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7844698
13 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7665851
12 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608082
24 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7418119
16 March 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7412320
24 February 2022
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7389663
28 February 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147673
19 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6957675
11 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6924703
25 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914890
25 February 2019
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6622804
17 April 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6392883
22 February 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6359575
4 January 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332509
29 March 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112524
29 January 2016
Administrative Inspection · Annual Inspection · In-Service Inspection · Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5807485
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector (MI) identified dead end wires located inside the port side engine room ventilation port. Conduct repairs to the satisfaction of the MI.
46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Received photos of heat sealed wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector identified dead end wires located on top of the wheelhouse, on the port side. Conduct repairs to the satisfaction of the MI.
46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Received satisfactory photo of heat sealed wire.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2025
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Marine Inspector identified a broken bonding wire on the bait tank pump overboard. Conduct repairs to the satisfaction of the MI.
46 CFR 183.372
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Received satisfactory photo of bonding wire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025
Resolved
Each life jacket carried on a vessel on oceans...route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Marine Inspector identified 4 inoperable lights on life jackets. Conduct repairs and inspect all on board life jackets to the satisfaction of the MI.
46 CFR 180.75
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photos of corrected lifer jacket light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Marine Inspector identified that one of the life float's waterlight was inoperable. Conduct repairs to the satisfaction of the MI.
46 CFR 180.175(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Observed operational waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 April 2025
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Marine Inspector identified that all life float paddles were not properly lashed to the body of the life float. Conduct repairs to the satisfaction of the MI.
46 CFR 180.175 (f)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photos of life float paddles in their proper configuration.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2025
Resolved
Electrical equipment exposed to the weather must be watertight. Marine Inspector identified that the sternlight housing mount was cracked and missing a screw, inhibiting watertightness. Conduct repairs to the satisfaction of the MI.
46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
Each...ring life buoy must be marked with Type II retroreflective material...The arrangement...must be as specified by IMO Resolution A.658(16). Marine Inspector identified that the retroreflective material on the ring life buoy was weathered and peeling. Conduct repairs to the satisfaction of the attending MI.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photos of ring life buoy retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
Each ring life buoy on a vessel must: (2) Be readily accessible;(3) Be stowed in a way that it can be rapidly cast loose. Marine Inspector assessed that the ring life buoy was not readily accessible. Re-locate to the satisfaction of the attending MI.
46 CFR 180.70(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photos of new location for storage.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 21 April 2025
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Marine Inspector identified that fire fighting drills were not properly logged in the vessel log book.
46 CFR 185.524(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photo copies of log books.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 21 April 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Marine Inspector identified that abandon ship and man overboard drills were not properly logged in the vessel log book.
46 CFR 185.520(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 May 2025
Resolution: Vessel operator provided photo copies of their logbook.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets. Marine Inspector identified that the fire buckets exceeded 2.5 gallons. Conduct repairs to ensure that the buckets cannot exceed a water capacity above 2.5 gallons.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Received photos of satisfactory fire buckets.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 April 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. Engine Room FWD bulkhead has insufficient vapor tight boundary at both STBD and PORT side bulkhead penetrations near the overhead deck. Additionally, there are multiple existing fastener (screw) holes that require closing. Fill all bulkhead penetrations to achieve sufficient vapor barrier to satisfaction of Marine Inspector.
46 CFR 182.35-1 (a) OLD-T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 22 June 2023
Resolution: All open vapor boundries sealed to satisfaction of MI.
Documentation › Certificates/Documents › FCC SSL
Issued 17 April 2018
Resolved
FCC Station License is expiered.
Condition: Improper/Lack of Maintenance
Due 21 April 2018
Resolved 23 April 2018
Resolution: New certificate obtained from FCC.
Lifesaving › Lifebuoys › Serviceable
Issued 17 April 2018
Resolved
Renew Life Ring (rope is deteriorated).
Condition: Improper/Lack of Maintenance
Due 21 April 2018
Resolved 23 April 2018
Resolution: Receipt of purchase sent.