Registered dimensions (L × B × D)57.7 ft × 19.6 ft × 5.5 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BAY BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
18 May 2026
DAPI Audit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8376273
25 February 2026
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8316443
26 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8167747
1 May 2025
Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8126495
24 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7939480
20 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7718710
1 May 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678542
27 April 2023
Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7683784
11 July 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7504644
24 June 2022
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7485697
27 April 2022
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7439472
7 May 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7190241
23 April 2021
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7181188
23 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7146830
23 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7064200
20 June 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6685658
16 April 2019
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6663018
8 August 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6555152
18 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6381110
22 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6248752
6 June 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6223518
12 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6122994
6 April 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5848510
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 May 2026
Resolved
MI witnessed rotted wood on floor beam IWO STBD shaft thru-hull penetration inside fuel tank space. Rotted wood must be removed and replaced with temporary repair prior to passengers. Approved temp repairs will permit operation with a 3nm restriction until permanent repairs are approved and completed in next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2026
Resolved 19 May 2026
Resolution: MI witnessed effective repairs to all 3 rotted floor beams. Temp repairs permit operations with newly restricted route conditions of no more than 3nm from shore until permanent repairs are complete.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 February 2026
Resolved
Attending MI witnessed temp repairs made to rotted structural floor beams in tank space IWO STBD shaft hull penetration. No repair proposal was submitted prior to repairs, repairs were inspected after the fact but deemed acceptable. Vessel is restricted in it's route to operate no more than 3nm from shore until permanent repairs are completed during it's next dry dock and prior to the 2027 operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2027
Resolved 19 May 2026
Resolution: Conducted Temporary repairs, Permanent Repairs will be made at next DDX. a Special Note has been entered.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 June 2022
Resolved
EPIRB battery expired. Vessel restricted to 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2022
Resolved 25 August 2022
Resolution: Owner purchased new EPIRB.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 May 2021
Resolved
Hydro release expired
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 7 May 2021
Resolved 26 May 2021
Resolution: MI attended vessel and cleared requirement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 May 2021
Resolved
Repair or replace port engine tach at helm
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 26 May 2021
Resolution: MI attended vessel and cleared requirement
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 April 2019
Resolved
Open up and make available for inspection port side plank as discussed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 1 May 2019
Resolution: O/O completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 April 2019
Resolved
Open up and make available for inspection stbd. side plank as discusssed
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 1 May 2019
Resolution: O/O completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 April 2019
Resolved
Replace transom planks iwo of port MDE overboard discharge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 1 May 2019
Resolution: O/O completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 April 2019
Resolved
Open up and make available for inspection #1 plank port side of the garboard plank iwo of doubler located near prop
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 1 May 2019
Resolution: O/O completed repair
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2019
Resolved
Replace port side fuel fill pipe
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 17 April 2019
Resolution: O//O conducted permanent repairs
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 April 2019
Resolved
By 30APR20 replace transom planks iwo stbd. side MDE overboard exhaust
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 25 September 2020
Resolution: Replaced transome planks, witnessed my [name withheld] on annual.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 6 June 2017
Resolved
PORT MAIN ENGINE EXHAUST LEAK
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 22 August 2017
Resolution: welded and no longer leaking
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2017
Resolved
MASTHEAD LIGHT INOP
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 August 2017
Resolution: masthead light replaced and operating
Fire Fighting › Nozzles › Number
Issued 6 June 2017
Resolved
MISSING VARI-NOZZLE
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 22 August 2017
Resolution: provided new nozzle
Operations/Management › Pollution › Retention of Oily Mixture
Issued 6 June 2017
Resolved
DIRTY BILGE
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 22 August 2017
Resolution: bilges clean
Communications › Radio Communications › EPIRB
Issued 6 April 2016
Resolved
Make EPIRB inspection ready. Vessel restricted to operating <3 miles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 31 October 2016
Resolution: EPRIB on board vessel with valid battery dates.
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 April 2016
Resolved
Wire compass light to make light operational. Restricted to daylight operations.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 31 October 2016
Resolution: Compass light observed to be working.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 6 April 2016
Resolved
Install new emergency broadcast placard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 31 October 2016
Resolution: New emergency broadcast placard posted at operation station adjacent to radio installation.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 April 2016
Resolved
Complete supervisor EAP training and complete crew training.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 31 October 2016
Resolution: Vessel master's EAP supervisor certificate on board and crew training completed.
Engineering › Bilge Water Management System › Piping
Issued 6 April 2016
Resolved
Cap outboard starboard side bilge line forward of starboard engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 31 October 2016
Resolution: Bilge line forward of starboard main engine capped off.