Inspection history · 64
18 June 2020
Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6980413
2 December 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6900628
6 January 2005
Administrative Inspection · Periodic Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2269993
23 October 2003
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1932054
25 November 2002
Annual Inspection · Internal Structural Exam
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1710238
2 April 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1600612
27 February 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1490073
23 January 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1481072
14 January 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1478637
8 January 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1476836
19 November 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 493228
5 November 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 524196
1 October 2001
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1391696
19 September 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 515556
29 August 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 527498
17 April 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 471400
13 October 2000
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1391390
3 October 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 282789
16 August 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 526003
24 July 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 496948
24 January 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 462274
28 October 1999
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1415263
14 July 1999
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 493911
9 December 1998
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1472013
13 April 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 494801
23 February 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 478364
5 December 1997
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1421434
26 November 1997
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1398768
2 September 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 442080
5 March 1997
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1406090
31 October 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 499321
18 March 1996
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1077571
20 November 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 507466
30 October 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 466730
13 March 1995
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 862185
31 March 1994
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1166903
22 March 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 464171
12 March 1993
COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1379734
30 November 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 832660
29 November 1991
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 938801
15 November 1991
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 936431
27 September 1991
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 936654
20 August 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 940853
25 July 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 441695
25 February 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 471718
19 November 1990
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1211620
28 August 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1219608
16 August 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 437243
16 August 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914739
15 February 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 525375
16 November 1989
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 907042
2 June 1989
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 437150
3 April 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 484327
2 December 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350160
21 November 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206824
5 January 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 506297
23 November 1987
MARPOL Annex II Examination · COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026792
10 November 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1330532
13 July 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 436681
27 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331968
22 April 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319851
18 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991571
9 August 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 497272
16 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970495
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 21 January 2005
Resolved
Place the current COFR on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: A review of the vessel details indicates COD expired in 2012, COI was surrendered at an unknown date. One open deficiency cancelled.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 January 2005
Resolved
Conduct and document annual cargo piping hydrostatic testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: A review of the vessel details indicates COD expired in 2012, COI was surrendered at an unknown date. One open deficiency cancelled.
Construction/Loadline › Markings
Issued 13 May 2003
Resolved
Repaint draft marks ensuring contrast to hull color. 46 CFR 32.05. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 15 May 2003
Resolution: Draft marks painted.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 13 May 2003
Resolved
Repaint stenciling of the cargo pump emergency shutdown sign. 46 CFR 32.50-35 LEGACY COMPONENT DESC: Emergency Shut-down
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 15 May 2003
Resolution: Sign restencilied
Documentation › Certificates/Documents
Issued 13 May 2003
Resolved
Provide proof of a valid Certificat of Financial Responsibility. 33 CFR 138. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2003
Resolved 8 September 2003
Resolution: COFR # 854298-16 issued by NPFC: [name withheld]
Operations/Management › Vessel Safety Management
Issued 10 January 2003
Resolved
Complete the repairs required by the internal structural exam that was conducted on December 5, 2002. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 29 January 2003
Resolution: Owners of the vessel have contracted to have the barge repairs completed at DTC Enviromental, Congo, WV. For ISE credit.
13MAY03: All repairs completed and satisfactory air tests witnessed.
Construction/Loadline
Issued 5 March 1997
Resolved
PERFORM PERIODIC GAUGING OF MIDBODY AS REQUIRED BY 46 CFR 31.10-21(a) AT NEXT DRYDOCKING CONDUCTED AFTER JAN 2002. (30 YEAR ANNIVERSARY)
Condition: Unknown
Due 30 November 2007
Resolved 13 January 2003
Resolution: Not corrected. Put special note in for gauging requirement.
Deck/Cargo
Issued 5 March 1997
Resolved
INSTALL CARGO TANK OVERFILL DEVICES AS REQUIRED BY 33 CFR 155.480.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Construction/Loadline
Issued 20 August 1991
Resolved
CROP OUT AND RENEW OR PROVIDE A SUITABLE REPAIR TO STERN BOX WRAPPER PLATE IN WAY OF THE MAIN DECK WHERE SPIDER-WEB LIKE CRACKING HAS PROPAGATED IN A PREVIOUS REPAIR ATTEMPT. THIS IS TO BE COMPLETED TO THE SATISFACTION OF THEATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Documentation
Issued 16 August 1990
Resolved
PLACE CURRENT COI ONBOARD THE VESSEL.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Deck/Cargo
Issued 16 August 1990
Resolved
REPAIR FAULTY EMERGENCY SHUTDOWN AND PROVE PROPER OPERATION TO COGNIZANT [name withheld] LOADING.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Construction/Loadline
Issued 21 November 1988
Resolved
MAKE PERMANENT REPAIRS TO HORIZONTAL 4" FRACTURE OF SIDE SHELL FORWARD OF STBD FWD DRAFT MARKS AT 8'6" MARK.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Construction/Loadline
Issued 21 November 1988
Resolved
EXAMINE AND MAKE PERMANENT REPAIRS TO 18" VERTICAL FRACTURE AT STBD AFT CORNER OF SIDE SHELL.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Deck/Cargo
Issued 21 November 1988
Resolved
MAKE TWO REACH RODS VAPORTIGHT AT THE DECK.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Deck/Cargo
Issued 21 November 1988
Resolved
PROVIDE FLAME SCREEN FOR #1 STBD CARGO TANK ULLAGE.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Construction/Loadline
Issued 21 November 1988
Resolved
PROVIDE FLAME SCREEN OR CAP FOR STERN VOID GOOSENECK VENT.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Electrical
Issued 21 November 1988
Resolved
PROVIDE PRESSURE TYPE WIRE FITTING ON DEAD END WIRES FOR CENTER ELECT BOX ON STERN AND COVER BOX.
Condition: Unknown
Due 21 November 1988
Resolved 21 November 1988
Construction/Loadline
Issued 10 November 1987
Resolved
VESSEL IS PERMITTED TO PROCEED TO PORT ALLEN MARINE FOR THE PURPOSE OF CONDUCTING A CREDIT DRYDOCK EXAMINATION. VESSEL IS PERMITTED TO PROCEEDWITHOUT CARGO.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987