Records from 1985 to 2014. Most recent: inspection, 7 October 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 71
7 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5000814
2 June 2012
Type not recorded
No type recorded · Boat Forces Unit United States Virgin Islands · USCG Southeast District (CGD-SE) · Activity 4335735
1 July 2011
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4063922
16 November 2010
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3949987
15 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3664672
11 August 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3295210
6 September 2007
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3050934
9 July 2007
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2990308
26 June 2007
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2974352
10 August 2006
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2742404
20 September 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2496033
29 July 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2442070
24 September 2004
Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2204133
30 July 2004
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2150468
29 July 2004
Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2142395
13 November 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1948177
3 October 2003
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1896429
30 September 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1726974
6 August 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1869519
7 July 2003
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1838834
24 September 2002
Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1686007
4 September 2002
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1670210
2 July 2002
MARPOL Annex V Examination · COI Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1639748
17 October 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1366649
24 August 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1071225
14 August 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406998
3 August 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440369
20 October 1999
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448049
2 September 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1118969
1 September 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1029452
6 July 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388853
3 August 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 796042
22 July 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1129177
3 November 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460132
7 August 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783510
17 July 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781193
25 January 1997
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1101202
17 July 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089743
31 May 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084637
20 November 1995
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 874749
27 July 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1079257
6 July 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1185480
13 June 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 176513
1 August 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173860
31 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 145014
26 October 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 826475
7 October 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1134417
10 August 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1139378
20 October 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940233
10 September 1992
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 935737
12 August 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268687
8 November 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244202
7 November 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244054
22 October 1991
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1249679
26 August 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265038
25 June 1991
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246970
18 June 1991
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246968
3 May 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000073
29 August 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1214640
17 January 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917724
30 August 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 932098
2 November 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1200647
14 September 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1041567
21 September 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1313970
14 September 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314463
19 December 1986
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1026985
30 October 1986
COI Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012733
15 September 1986
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024697
15 October 1985
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 985192
15 October 1985
Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1295552
20 September 1985
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298099
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2011
Resolved
Dead or excess wiring under bridge console. Remove excess wires under bridge console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2011
Resolved 11 August 2011
Resolution: Removed dead wires and capped open wires.
Fire Fighting › Fire Pumps › Pressure
Issued 4 August 2011
Resolved
Pump gauge reads 100 psi. Demonstrate correct pressure on fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Resolution: Gauge reading suitable pressure (60 psi).
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 August 2011
Resolved
Extinguishers are mounted with incorrect brackets. Mount "L" brackets for all fire extinguishers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 August 2011
Resolution: Mounted extinguishers with correct brackets.
Documentation › Certificates/Documents › Stability Letter
Issued 4 August 2011
Resolved
Provide new Stability Letter of Intent to accommodate new regulations for passenger weight at 185#.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 10 June 2013
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 August 2011
Resolved
Child/adult life jackets are currently stowed together and the stowage container is not marked with child life jackets. Separate storage of adult and child life jackets and properly mark stowage.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Resolution: Stowed child life jackets on O1 deck below a bench and marked as such.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 4 August 2011
Resolved
Conduct sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Resolution: Conducted satisfactory sea trials.
Fire Fighting › Nozzles › Type
Issued 1 July 2011
Resolved
Nozzles not providing appropriate spray pattern. Provide suitable fire nozzles.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Resolution: Replaced nozzles with brass nozzles.
Construction/Loadline › Hull › Side Shell
Issued 16 November 2010
Resolved
Noted (5) areas on external shell for cropping and renewing w/ 3/8 steel. See narrative for specifics.
Action required: 705 - Other - as specified
Resolved 21 February 2011
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 November 2010
Resolved
Noted nearly all thru-hull opening to be wasted. Clean and make available for inspection. Replace as necessary.
Action required: 705 - Other - as specified
Resolved 21 February 2011
Construction/Loadline › Structures › End Bulkhead
Issued 16 November 2010
Resolved
Noted several areas in the WTB's in the fuel room and aft glass viewing rooms for replacement as original.
Action required: 705 - Other - as specified
Resolved 12 July 2011
Engineering › Bilge Water Management System › Piping
Issued 16 November 2010
Resolved
Noted majority of bilge piping system to be replaced due to wastage.
Action required: 705 - Other - as specified
Resolved 12 July 2011
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 November 2010
Resolved
Noted piping adjacent fuel tank to be wasted. Replace as original.
Action required: 705 - Other - as specified
Resolved 12 July 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2008
Resolved
Provide proof of enrollment in drug and alcohol testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2008
Resolved 11 August 2008
Fire Fighting › Fire Main › Pressure
Issued 11 August 2008
Resolved
Prove proper operation of the fire main prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2008
Resolved 11 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 11 August 2008
Resolved
Replace overboard discharge valve.
Due 18 August 2008
Resolved 21 August 2008
Fire Fighting › Fire Pumps › Pressure
Issued 11 August 2008
Resolved
Replace fire pump.
Due 18 August 2008
Resolved 21 August 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 July 2007
Resolved
Make proper repairs to the hydraulic steering hose and demonstrate proper operations to the satisfaction of an attending marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2007
Resolved 11 July 2007
Construction/Loadline › Hull › Bottom Plating
Issued 20 September 2005
Resolved
CROP OUT 4'X5' AREA OF BOTTOM PLATE IN WAY OF PORT SIDE STEERING COMPARTMENT.
Due 20 October 2005
Resolved 4 October 2005
Construction/Loadline › Hull › Bottom Plating
Issued 20 September 2005
Resolved
REMOVE RUST SCALE BUILD-UP IN WAY OF ENGINEROOM BILGE FOR FURTHER INSPECTION.
Due 20 October 2005
Resolved 4 October 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 September 2005
Resolved
RENEW GENERATOR SEA VALVE.
Due 20 October 2005
Resolved 4 October 2005
Documentation › Logs/Records › Declaration of Inspection
Issued 4 September 2003
Resolved
Provide copy of vessel plans to MSD Marathon for inclusion in vessel's permanent file. LEGACY COMPONENT DESC: Vessel Plans
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 1 August 2005
Electrical › Electric Generation Source (service) › Generator
Issued 4 September 2003
Resolved
Demonstrate satisfactory operation of new generator installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2003
Resolved 1 August 2005
Lifesaving › Buoyant Apparatus
Issued 7 July 2003
Resolved
Provide one Sea Painter with weak link for not more than three grouped buoyant apparatus not later than 07August2003. LEGACY COMPONENT DESC: Sea Painter
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 2 October 2003
Resolution: Witnessed satisfactory installation of weak link for both groups of IBAs
Lifesaving › Buoyant Apparatus
Issued 7 July 2003
Resolved
Renew lifeline on each buoyant apparatus with buoyant line of not less than 3/8 in. not later than 07August2003. LEGACY COMPONENT DESC: Lifeline
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 2 October 2003
Resolution: Witnessed renewed lifeline.
Engineering › Bilge Water Management System
Issued 7 July 2003
No resolution recorded
Renew bilge strainers in lazarett not later than 07August2003. LEGACY COMPONENT DESC: Strainer
Action required: 705 - Other - as specified
Due 7 August 2003 — due date passed with no resolution recorded
Resolution: Witnessed new installation of bilge strainers, all sat.
Construction/Loadline › Structures
Issued 7 July 2003
Resolved
Re-attach transverse frame at fuel tank during next drydock. LEGACY COMPONENT DESC: Transverse Framing
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 2 October 2003
Resolution: Witnessed, all sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 July 2003
Resolved
Make permanent repairs to #2 & #5 ladder rung in fuel tank void during next drydock. LEGACY COMPONENT DESC: Ladder Rung
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 2 October 2003
Resolution: Witnessed, all sat.
Construction/Loadline › Structures
Issued 7 July 2003
Resolved
Re-weld gusset to main deck at hatch to fuel void port-side during next dry dock. LEGACY COMPONENT DESC: Gusset
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 13 November 2003
Resolution: Observed corrected.
Fire Fighting › Fire Hoses
Issued 7 July 2003
Resolved
Renew #1 fire hose not later than 07August2003. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 6 August 2003
Resolution: Received invoice for the purchase of one 50'' firehose.
Lifesaving › Buoyant Apparatus
Issued 7 July 2003
Resolved
Sand and paint buoyant apparatus international orange not later than next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 2 October 2003
Resolution: Completed during drydock period in FT Myers Beach
Engineering › Bilge Water Management System › Eductor
Issued 7 July 2003
No resolution recorded
Provide a means for testing forepeak bilge suction not later than next dry dock.
Action required: 705 - Other - as specified
Due 30 September 2003 — due date passed with no resolution recorded
Resolution: Witnessed satisfactory test of forepeak bilge suction.
Communications › Radio Communications
Issued 2 July 2002
Resolved
Service/replace battery for 406 MHz EPIRB. Currently installed battery expired on 30Jun02. This requirement shall be corrected prior to carrying passengers beyond 3 miles from shore. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 19 July 2002
Resolved 2 July 2002
Resolution: Corrected. owner purchased an registered a new 406 MHz EPIRB.
Electrical › Electrical Distribution System (service)
Issued 2 July 2002
Resolved
Install protective cover off the dead-front type on the breaker panel in the companionway leading to the engineroom. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 2 July 2002
Resolved
Replace wire nuts with pressure connectors in the fire pump controller box, the electrical bilge wires and the temporary junction box tied to the fire main and permanently mount junction box. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 2 July 2002
Resolved
Install metallic wire supports in engine room every 24 inches in accordance with 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected
Engineering › Bilge Water Management System
Issued 2 July 2002
Resolved
Replace (1) bilge hose with approved reinforced hose. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected.
Engineering › Bilge Water Management System
Issued 2 July 2002
Resolved
Renew holed/wasted fitting in engineroom bilge line leading from the electrical bilge pump. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 2 July 2002
Resolved
Repair wires in fire pump control panel and on port MDE so that excessive bare conductors are no longer exposed. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected.
Engineering › Fuel Oil Storage/Transfer System
Issued 2 July 2002
Resolved
Install new 30 x 30 corrosion resistant, metallic, mesh flame screen in way of vessel's fuel vents. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 2 July 2002
Resolved
Remove excess wires for electrical bilge pumps or support wiring so excess does not interfere with the operation of the float switch. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 August 2002
Resolved 4 September 2002
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety
Issued 2 July 2002
Resolved
Install mesh netting or course rails between bulwark and top rail so that no space is greater than 4 inches. Correct not later than 02Sep02. LEGACY COMPONENT DESC: Deck Rail
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 30 September 2002
Resolution: Corrected
Construction/Loadline
Issued 17 October 2001
Resolved
REPAIR/REPLACE DETERIORATED SECTIONS OF HULL PLATE BELOW WATERLINE. SEE CASE DIARY FOR DETAILS.
Condition: Unknown
Due 14 November 2001
Resolved 14 November 2001
Lifesaving
Issued 14 August 2001
Resolved
Retro-reflective tape on PFDs found worn and unserviceable. Replace/renew retro-refective tape on PFDs.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Lifesaving
Issued 14 August 2001
Resolved
Retro-reflective tape missing from 24 inch life ring buoy. Provide Retro- reflective tape for buoy.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Fire Fighting
Issued 14 August 2001
Resolved
Vessel's 110 volt power driven fire pump operated w/insufficient pressure. Prove proper operation of fire pump at minimum of 60 psi IAW 46 CFR 181.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Construction/Loadline
Issued 14 August 2001
Resolved
Vessel's power driven bilge pump/fire pump inoperable at time of inspection. Prove proper operation of mechanical fire pump/bilge pump on starboard main diesel engine.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Construction/Loadline
Issued 6 July 1999
Resolved
Complete high water alarm installation by 20JUL99.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Construction/Loadline
Issued 6 July 1999
Resolved
Prior to 30NOV99, crop & renew the #6 P/S long & transverse frames in forepeak compt.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Construction/Loadline
Issued 6 July 1999
Resolved
Prior to 30NOV99, crop/renew wasted metal @ base of port rudder stock.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Navigation
Issued 6 July 1999
Resolved
Prior to 30NOV99, replace outboard rudder stock brace, stbd side.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 22 July 1998
Resolved
Provide documentation of service for BII fire extinguisher in engine room.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Lifesaving
Issued 22 July 1998
Resolved
Properly mark ring buoys w/retro-reflective material.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Fire Fighting
Issued 22 July 1998
Resolved
No record of annual servicing for fixed Halon F/F system available.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Documentation
Issued 17 July 1997
Resolved
Provide a proper logbook with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 19 August 1997
Lifesaving
Issued 17 July 1997
Resolved
Replace 1 waterlight on 1 life float._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 19 August 1997
Lifesaving
Issued 17 July 1997
Resolved
Affix new retro reflective tape on life floats._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 19 August 1997
Construction/Loadline
Issued 1 August 1994
Resolved
Raise sill height of engineroom door to 6".
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Construction/Loadline
Issued 1 August 1994
Resolved
Crop and renew longitudinal member in aft center viewing port.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Engineering
Issued 1 August 1994
Resolved
Replace f/o fill pipe on portside.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Accommodation/Occupational Safety
Issued 1 August 1994
Resolved
Replace wasted forward void vent on the stbd side.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Construction/Loadline
Issued 1 August 1994
Resolved
Remove ballast in forepeak to allow inspection of hull.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Fire Fighting
Issued 1 August 1994
Resolved
Replace both non-approved fire hose nozzles.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Lifesaving
Issued 1 August 1994
Resolved
Replace port aft side ring buoy.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Accommodation/Occupational Safety
Issued 1 August 1994
Resolved
Remove LP bottle being used for air horn.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Accommodation/Occupational Safety
Issued 1 August 1994
Resolved
Test air compressor relief valve in presence of CG marine inspector.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Electrical
Issued 1 August 1994
Resolved
Remove or cap shore tie recepticle.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Accommodation/Occupational Safety
Issued 10 August 1993
Resolved
Replace 2 existing Type I MSD units certifried for pleasure craft less than65' with CG certified Type II or III suitable for the size and service of the vessel.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
REPLACE GAUGE TO LECTRA-SAN UNIT STBD. SIDE.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Construction/Loadline
Issued 12 August 1992
Resolved
REPLACE SEA WATER HOSES TO MSD'S WITH WIRE REINFORCED TYPE.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Electrical
Issued 12 August 1992
Resolved
PROVIDE COVER FOR 110V JUNCTION BOX PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Construction/Loadline
Issued 25 June 1991
Resolved
AUDIO GAUGE BULKHEAD BELOW MANHOLE COVER IN LAZARETTE AND CROP AND RENEW ASPER ITEM #3._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991
Resolved
PROVIDE 3 BELT GUAGINGS AS WELL AS ONE AT WIND AND WATER STRAKE.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991
Resolved
CROP AND RENEW AREAS IN LAZARETTE COMPARTMENT THAT WERE UT GAUGED IN MAY ORJUNE 1991 AND FOUND TO BE LESS THAN .1875"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991
Resolved
AUDIO GUAGE COLLISION BULKHEAD AND CROP AND RENEW TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991
Resolved
AUDIO GUAGE AFT AND INBOARD BULKHEADS IN PORT AND STARBOARD VOIDS (IN WAY OF MANHOLE COVERS) AND CROP AND RENEW IF NECESSARY TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Fire Fighting
Issued 14 September 1988
Resolved
REPLACE PLASTIC FIRE HOZE NOZZLE WITH ONE OF METALLIC MATERIAL.
Condition: Unknown
Due 14 September 1988
Resolved 14 September 1988
Accommodation/Occupational Safety
Issued 14 September 1987
Resolved
REMOVE EXTENSION CORDS TO TEMPORARY FANS FOR ENGINE ROOM VENTS. PROPERLY INSTALL NEW FORCED AIR VENTS IN THE ENGINE ROOM.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Electrical
Issued 14 September 1987
Resolved
INSTALL A SWITCH AND FUSE ON THE 16 VOLT DC ALARM BELL WIRING WHICH IS PRESENTLY CONNECTED DIRECTLY TO THE BATTERIES IN THE ENGINE ROOM.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Electrical
Issued 14 September 1987
Resolved
MAKE PROPER WIRE CONNECTION TO THE ELECTRIC SUBMERSABLE BILGE PUMP IN THE ENGINE ROOM.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Fire Fighting
Issued 14 September 1987
Resolved
REPLACE THE MISSING HAND PORTABLE FIRE AND BILGE PUMP WITH AN APPROVED PUMP AND ADEQUATE LENGTH OF HOSE.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Engineering
Issued 14 September 1987
Resolved
RELABLE THE EMERGENCY FUEL SHUT OFF VALVE LOCATION.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Electrical
Issued 14 September 1987
Resolved
THE 12 VOLT DC ELECTRICAL SYSTEM HAS NO SWITCHED CIRCUITS; INSTALL FUSED AND SWITCHED CIRCUITS FOR ALL 12 VOLT ELECTRICAL ACCESSORIES.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987