MAURY USCG vessel records Sign in
← All vessels

COWBOY

COWBOY is a 1972 passenger vessel (uninspected). The Coast Guard has recorded 62 inspections since 1985, most recently in October 2008, along with 91 deficiencies and 1 operational control.

Records from 1985 to 2008. Most recent: inspection, 15 October 2008.

Built
1972
Last inspected
15 October 2008
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBA9847
Flag
UNITED STATES
366925220 (licence lapsed)
Maury page id
psix-47161

Inspections, by type

…with no type recorded11
Years with a record 24 calendar years (1985–2008)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.4 ft × 12.8 ft × 6.0 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR & H MARINA INC · SEATTLE, WA, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBA9847MMSI 366925220 · expired · compulsorily equipped · granted 12 February 2004, cancelled 3 May 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 62

15 October 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3356495
19 September 2008 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3328307
18 July 2008 Type not recorded
No type recorded · Station Seattle · USCG Northwest District (CGD-NW) · Activity 3272499
20 June 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3242326
2 April 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3176372
10 September 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3066705
24 July 2007 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3008352
18 July 2007 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 3000028
18 July 2007 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3000057
17 July 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3005211
13 April 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2907421
6 June 2006 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2672038
3 May 2006 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2639859
29 April 2005 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2345627
8 March 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2305898
21 September 2004 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2200582
20 August 2004 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 2171879
3 October 2003 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1917755
9 May 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1617515
26 April 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1613619
5 April 2002 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1601766
1 May 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1063277
10 October 2000 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1055380
15 September 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430914
13 September 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 658137
1 August 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 214949
8 May 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1049559
21 September 1999 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465504
19 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 214367
19 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 228624
14 July 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397203
7 May 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1128652
7 October 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 801968
14 September 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400851
15 September 1997 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380995
5 December 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1461750
4 November 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371568
6 September 1995 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407549
8 September 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 864703
1 July 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466886
20 December 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 849699
17 November 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 836830
2 April 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1150527
4 February 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137048
16 October 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1268267
22 September 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1245767
22 January 1992 Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1257597
20 August 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1252100
24 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1237137
29 April 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1243018
9 October 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 905628
31 July 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 903009
20 July 1990 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 913289
25 July 1989 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1043038
11 May 1989 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1209042
20 July 1988 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1340292
20 April 1988 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1036203
28 May 1987 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1334819
28 April 1987 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1024524
20 June 1986 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1304719
7 June 1985 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1302551
26 March 1985 Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1307828

Deficiency record · 91

Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 October 2008 Resolved
Penetrations found in four water tight bulkheads. Make bulkheads water tight to satisfaction of attending Marine Inspector prior to carrying passengers for hirel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2008
Resolution: Bulkheads made water tight.
Operations/Management › Drills/Instruction › Fire
Issued 15 October 2008 Resolved
Operator not conducting fire and abandon ship drills. Operator must conduct and document required drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2008
Resolution: Witnessed required drills and verified documentation of drills in vsl log.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 October 2008 Resolved
Charts found uncorrected. Operator must provide corrected charts for operating area prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2008
Resolution: Verified that vessel operator has corrected charts on board.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 October 2008 Resolved
MSD overvboard dischard valve found open. Valve must be closed and secured.
Due 15 October 2008
Resolved 15 October 2008
Resolution: valve closed and wire tied in closed position.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 October 2008 Resolved
Fuel shut off valves location and operation not marked. Mark location of fuel shut off and mark operating instructions.
Due 17 October 2008
Resolved 17 October 2008
Resolution: Fuel shut off valve locations and operating instrucitons found marked.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 October 2008 Resolved
EPIRB tests are not being conducted nor logged, Operator must conduct and log EPIRB tests.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2008
Resolved 17 October 2008
Resolution: Witnessed test of EPIRB and verified that tests are being logged.
Engineering › Fuel Oil Service System › Hose
Issued 24 July 2007 Resolved
Renew engine compartment fuel tank fill hoses, port and stbd tanks.
Due 25 November 2007
Resolved 19 March 2008
Resolution: Replaced fuel tank fil hoses, port & starboard tanks.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 24 July 2007 Resolved
Provide proof of FCC Marine Operator permit.
Due 25 November 2007
Resolved 19 March 2008
Resolution: Provided proper proof of FCC Marine Operator permit.
Stability › Unintentional Flooding › General
Issued 24 July 2007 Resolved
Provide plans to make the engine compartment hatch watertight.
Due 25 November 2007
Resolved 19 March 2008
Resolution: Vessel has yet to provide watertight hatch, however routes have been changed
Engineering › Fuel Oil Service System › Valve
Issued 24 July 2007 Resolved
Prove operation of all three fuel cutout valves. Engine compartment must have remote reach rods and shielding. Prior to the carriage of passengers.
Due 25 August 2007
Resolved 25 July 2007
Resolution: Renewed and installed, tested sat.
Documentation › Markings/Placards › Warning Signs
Issued 24 July 2007 Resolved
Label all fuel cutoff valves, prior to the carriage of passengers.
Due 25 August 2007
Resolved 25 July 2007
Engineering › Lubricating Oil Service System › Hose
Issued 24 July 2007 Resolved
Install chaffing gear on reduction gear hoses as needed.
Due 25 November 2007
Resolved 19 March 2008
Resolution: Installed chaffing gear on reduction gear hoses.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 July 2007 Resolved
Repair fuel leak on racor fuel filter. Prior to the carriage of passengers.
Due 25 August 2007
Resolved 25 July 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 July 2007 Resolved
Repair fuel leak on port engine room fuel tank line fitting at tank, prior to the carriage of passengers.
Due 25 August 2007
Resolved 25 July 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 July 2007 Resolved
Repair fuel leak at the aft fuel tank valve, prior to the carriage of passengers.
Due 25 August 2007
Resolved 25 July 2007
Resolution: Valve renewed.
Communications › Alarms/Indicators › Fire Alarm
Issued 24 July 2007 Resolved
Install and prove operation of an USCG approved electrically supervised engine compartment heat detection system to the satisfaction of the attending USCG Marine Inspector.
Due 24 July 2008
Resolved 10 September 2007
Resolution: After further review of NTSB recommendation and NVIC 4-98, it was determined that the installed system is satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 April 2007 Resolved
Prove proper operation of radar.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2007
Resolution: new radar
Engineering › Bilge Water Management System › Not Operational
Issued 13 April 2007 Resolved
Prove proper operation of forward bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Resolution: Tested by STA GRAYS HBR
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 13 April 2007 Resolved
Replace retroreflective material on buoyant apparatus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Fire Fighting › Fire Bucket › Quantity
Issued 13 April 2007 Resolved
Provide one more fire bucket
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Personnel › Training › Fire Fighting Basic
Issued 13 April 2007 Resolved
Conduct drills with deckhand
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2007
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 13 April 2007 Resolved
Prove proper operation of fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 May 2006 Resolved
Required radar onboard for Oceans Route. Radar currently out for repair. Vsl can operate on a Lakes, Bays and Sounds Route until radar is operational.
Due 2 June 2006
Resolved 2 June 2006
Resolution: Radar repaired and installed.
Engineering › Bilge Water Management System › Not Operational
Issued 2 May 2006 Resolved
Prove proper operation of lazerette bilge alarm.
Due 2 June 2006
Resolved 2 June 2006
Resolution: Lazerette bilge alarm repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2006 Resolved
Prove proper operation of masthead light and port running light.
Due 2 June 2006
Resolved 2 June 2006
Resolution: Masthead light working properly.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 May 2006 Resolved
Provide proof of certificate of documentation.
Due 2 June 2006
Resolved 2 June 2006
Resolution: COD valid through May 21, 2007.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 April 2005 Resolved
B-1 extinguisher on bridge servicing past due.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 25 May 2005
Resolution: Rcvd receipt from owner of service
Communications › Radio Communications › EPIRB
Issued 29 April 2005 Resolved
EPIRB past due for servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 25 May 2005
Resolution: Service and corrected by approved maintenance facility
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 September 2004 Resolved
Vessel did not complete the required annual USCG inspection and is currently beyond the 90 day window allowed by the regulations. You are to surrender your USCG COI to the issuing USCG [name withheld] vessel may not carry more than 06 passengers for hire.
Due 21 October 2004
Resolved 29 April 2005
Resolution: Issued new COI effective this date.
Lifesaving › Rigid Liferafts › Buoyant Material
Issued 9 December 2003 Resolved
The life float had numerous cracks that needed to be repaired. The life float also needed new reflective tape. The buoyant line and water light needed to be properly attached to life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2004
Lifesaving › Lifebuoys
Issued 9 December 2003 Resolved
The vessel needs a new life ring with buoyant line and water light properly attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 December 2003 Resolved
The radar was not operable and must be repaired. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 9 January 2004
Resolved 29 April 2005
Resolution: Replaced radar
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 9 December 2003 Resolved
The master needed to provide proof of first aid and CPR training.
Action required: 705 - Other - as specified
Due 9 January 2004
Resolved 3 February 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 December 2003 Resolved
The magnetic compass could not illuminate and needed to be repaired.
Action required: 705 - Other - as specified
Due 9 January 2004
Resolved 3 February 2004
Engineering › Bilge Water Management System
Issued 9 May 2002 Resolved
PROVE PROPER OPERATION OF VESSEL'S BILGE ALARMS (ALL COMPARTMENTS). LEGACY COMPONENT DESC: Interface Detector
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2002
Resolution: RETESTED SAT.
Documentation › Certificates/Documents
Issued 9 May 2002 Resolved
PROVIDE PROPER FCC ISSUED STATION LICENSE. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 26 July 2002
Resolution: FCC cert provided
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 May 2002 Resolved
PROVIDE COAST GUARD APPROVED/ACCEPTED FIRST AID KIT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2002
Resolution: SIGHTED NEW CG APPROVED FIRST AID KIT.
Documentation › Certificates/Documents
Issued 5 April 2002 Resolved
MAKE VESSEL AVAILABLE FOR DRYDOCK EXAMINATION AND REINSPECTION TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO OPERATING WITH PASSENGER. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2002
Resolved 10 May 2002
Resolution: RE-ISSUED COI.
Lifesaving
Issued 15 September 2000 Resolved
Provide proper number of distress signals
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Unknown
Issued 15 September 2000 Resolved
Provide proof that deckhand is enrolled in drug testing program.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 15 September 2000 Resolved
Provide servicing report for fixed CO2 system
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Construction/Loadline
Issued 21 September 1999 Resolved
REPLACE KEEL BOLT NUTS IN CABIN BILGE.
Condition: Unknown
Due 30 October 2000
Resolved 10 May 2002
Resolution: SIGHTED DURING VESSEL''S CREDIT DRYDOCK EXAMINATION.
Fire Fighting
Issued 21 September 1999 Resolved
PROVIDE VENT CLOSURES FOR ENGINE ROOM HATCH COVER VENTILATION DUCTS.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Fire Fighting
Issued 14 July 1999 Resolved
PROVIDE CLOSURES FOR ENGINEROOM NATURAL VENTILATION (CO2 F/F SYSTEM).
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 14 July 1999 Resolved
PROVIDE OPERABLE WATERLIGHT FOR LIFEFLOAT, PRIOR TO CARRYING PASSENGERS FORHIRE.
Condition: Unknown
Due 14 July 1999
Resolved 9 August 1999
Documentation
Issued 14 July 1999 Resolved
POST EMERGENCY BROADCAST PLACARD IN A CONSPICIOUS LOCATION IN THE VICINITY OF VHF RADIO, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 July 1999
Resolved 9 August 1999
Fire Fighting
Issued 14 July 1999 Resolved
PERMANENTLY INSTALL CO2 FIXED FIRE FIGHTING PIPE AND NOZZLE IN ENGINEROOM.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 14 July 1999 Resolved
MOUNT EPIRB IN A FLOAT FREE POSITION, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 July 1999
Resolved 9 August 1999
Construction/Loadline
Issued 14 September 1998 Resolved
RENEW LANYARD FOR HATCH OVER LAZERETTE.
Condition: Unknown
Due 30 September 1998
Resolved 16 October 1998
Navigation
Issued 14 September 1998 Resolved
DOUBLE NUT MOUNTING BOLTS FOR STEERING RAM FOUNDATION.
Condition: Unknown
Due 30 September 1998
Resolved 16 October 1998
Lifesaving
Issued 14 September 1998 Resolved
PROVE PROPER OPERATION OF EPIRB.
Condition: Unknown
Due 30 September 1998
Resolved 16 October 1998
Navigation
Issued 14 September 1998 Resolved
PROVIDE ALL REQUIRED NAUTICAL CHARTS AND PUBLICATIONS AND CORRECT CHARTS ONBOARD.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Electrical
Issued 14 September 1998 Resolved
SECURE ELECTRICAL CABLE FOR LAZERETTE BILGE PUMP.
Condition: Unknown
Due 30 September 1998
Resolved 16 October 1998
Construction/Loadline
Issued 14 September 1998 Resolved
SEAL HOLES IN WATERTIGHT BULKHEAD BETWEEN ACCOMODATION SPACE AND ENGINE ROOM AND BULKHEAD BETWEEN ENGINE ROOM AND LAZZERETTE.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Fire Fighting
Issued 14 September 1998 Resolved
HAVE BI FIRE EXTINGUISHER ON BRIDGE HYDROED AND SERVICED.
Condition: Unknown
Due 30 September 1998
Resolved 16 October 1998
Documentation
Issued 15 September 1997 Resolved
Provide evidence of current documentation certificate.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Construction/Loadline
Issued 15 September 1997 Resolved
Prove proper operation of engine room bilge pump.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Documentation
Issued 15 September 1997 Resolved
Vsl is restricted from carrying passangers until vsl provides evidence of current documentation certificate.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Lifesaving
Issued 15 September 1997 Resolved
Provide emergency brodcast placard.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Navigation
Issued 15 September 1997 Resolved
Update charts with latest notice to mariners corrections.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Construction/Loadline
Issued 15 September 1997 Resolved
Prove proper operation of steering compartment bilge pump.
Condition: Unknown
Due 19 September 1997
Resolved 24 September 1997
Documentation
Issued 4 November 1996 Resolved
MISSING ORIGINAL COPY OF STABILITY LETTER
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Unknown
Issued 4 November 1996 Resolved
POST "CREW ONLY" SIGNS AT BOTTOM OF LADDERS LEADING TO PILOT HOUSE TO BRINGVSL IN COMPLIANCE WITH STABILITY LTR.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Lifesaving
Issued 4 November 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Lifesaving
Issued 4 November 1996 Resolved
REPLACE EXISTING DISTRESS SIGNAL CONTAINER WITH ONE WHICH IS BRIGHT AND WATERTIGHT.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Electrical
Issued 4 November 1996 Resolved
CLEAN EXCESSIVE CORROSION FROM BATTERY TERMINALS IN ENGINE ROOM.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Navigation
Issued 4 November 1996 Resolved
MISSING CURRENT CHARTS FOR AREA OF OPERATION
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Construction/Loadline
Issued 4 November 1996 Resolved
PROVIDE KEEPER CHAIN FOR LAZARETTE HATCH.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Navigation
Issued 4 November 1996 Resolved
REPLACE EMERGENCY STEERING TILLER DUE TO EXCESSIVE CORROSION.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Lifesaving
Issued 8 September 1994 Resolved
LABEL EXTERIOR EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Navigation
Issued 8 September 1994 Resolved
REPAIR AND PROVE OPERATION OF RADAR.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Engineering
Issued 1 July 1994 Resolved
REPLACE CORRODED TROLLING CONTROL LINE.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Navigation
Issued 17 November 1993 Resolved
PROVE PROPER OPERATION OF STARBOARD RUNNING LIGHT AND MASTHEAD RUNNING LIGHT NOT LATER THAN THE DATE INDICATED OR PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993 Resolved
REPLACE RING BUOY PRIOR TO THE CARRIAGE OF PASSENGERS ON NLT 17 DECEMBER 1993.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Fire Fighting
Issued 22 September 1992 Resolved
PROVIDE PROPER SERVICING FOR B-I FIRE EXTINGUISHER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Unknown
Issued 22 September 1992 Resolved
REPLACE VESSEL NAME ON BOW (PORT & STBD) PER 46 CFR 67._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Lifesaving
Issued 22 September 1992 Resolved
PROVE PROPER OPERATION OF RINGBUOY WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Lifesaving
Issued 22 September 1992 Resolved
PROVE PROPER OPERATION OF EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Engineering
Issued 22 September 1992 Resolved
REPLACE FUEL TANK FLAME SCREEN ON AFT STBD FUEL TANK VENT (PAINTED OVER)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Engineering
Issued 20 August 1991 Resolved
REPLACE OR CLEAN FUEL TANK FLAME SCREENS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Documentation
Issued 20 August 1991 Resolved
PROVIDE AND POST FCC STATION LICENSE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Navigation
Issued 20 August 1991 Resolved
PROVIDE UPDATED CHARTS AND PUBS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Lifesaving
Issued 20 August 1991 Resolved
PROVIDE WEAKLINK FOR LIFEFLOAT PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Documentation
Issued 20 July 1990 Resolved
PROVIDE CURRENT T REGULATION.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Engineering
Issued 20 July 1990 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE AND FIRE AND BILGE PUMPS.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Documentation
Issued 20 July 1990 Resolved
PROVIDE CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Documentation
Issued 20 July 1990 Resolved
PROVIDE AND POST STABILITY LETTER.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Lifesaving
Issued 20 July 1990 Resolved
RESTENCIL ALL LIFESAVING GEAR WITH VESSEL'S NEW NAME.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Navigation
Issued 20 July 1990 Resolved
SWING VESSEL FOR NEW DEVIATION CARD.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Navigation
Issued 20 July 1990 Resolved
PROVE PROPER OPERATION OF NAV LIGHTS.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Lifesaving
Issued 20 July 1990 Resolved
PROVIDE PADDLES FOR LIFE FLOAT.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990

Ownership record