← All vessels

ECLIPSE

ECLIPSE is a 1972 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1984, most recently in April 2025, along with 199 deficiencies and 1 operational control.

Records from 1984 to 2025. Most recent: inspection, 29 April 2025.

Built
1972
Last inspected
29 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5562
Flag
UNITED STATES
368217460
Maury page id
psix-47167

Inspections, by type

…with no type recorded14
Years with a record 39 calendar years (1984–2025)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.9 ft × 27.2 ft × 9.7 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUT MARINE CORP · WARREN, RI, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM5603MMSI 368217460 · active · compulsorily equipped · granted 2 September 2021, expires 2 September 2031
WDC5562MMSI 367042980 · expired · compulsorily equipped · granted 8 May 2015, cancelled 21 June 2025 · licensed under a name not among this hull’s recorded names (not shown)
WCB2411MMSI not assigned · expired · compulsorily equipped · granted 4 August 1998, cancelled 20 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 93

29 April 2025 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123035
6 March 2025 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8088977
23 December 2024 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8050554
3 September 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7994860
4 March 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7872458
12 May 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7686766
12 May 2023 Special Consideration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7686833
22 March 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655027
13 December 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601245
27 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331750
3 June 2021 Drydock Exam · Hull Examination · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7214732
6 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6998552
21 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6790211
30 April 2019 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672548
21 August 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6518487
25 May 2017 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6155739
3 May 2017 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6134723
27 January 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6078257
29 March 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842584
13 August 2015 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5214474
14 October 2014 Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5012639
5 August 2014 MTSA Verification · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4944399
11 May 2012 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4308177
20 April 2009 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3457172
18 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320041
7 August 2008 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3291496
3 April 2008 Hull Examination · Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3188787
16 October 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3081038
22 June 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2970420
25 May 2007 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2939878
7 May 2007 MARPOL Annex V Examination · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2925376
26 May 2006 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2659765
18 May 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2654291
10 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582846
16 June 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2392208
16 June 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2392344
19 May 2005 MTSA Verification · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2361691
15 September 2004 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2196605
14 July 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2132921
9 June 2004 Annual Inspection · MARPOL Annex V Examination · MTSA Verification · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2093227
16 October 2003 COI Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1929914
30 July 2003 Hull Examination · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1861303
26 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1666353
16 August 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1662253
2 August 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1655700
30 July 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1654143
2 August 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366520
10 July 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376672
31 July 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406768
5 August 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418576
16 July 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1463489
10 August 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415036
13 November 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 786652
9 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 785979
31 July 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781324
21 July 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 779944
10 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 94128
9 August 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1088750
17 July 1996 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1089678
7 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875538
20 September 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1185309
15 August 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186979
10 August 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871301
21 September 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172229
3 December 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401785
22 September 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840205
10 August 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151153
20 April 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946445
1 April 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261707
25 February 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1317743
25 February 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1230229
3 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917350
28 September 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 902636
7 September 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925490
7 March 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 920323
31 January 1990 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 920455
24 January 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1213982
19 October 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 893632
21 August 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 888050
9 May 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1201022
13 March 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1200603
24 January 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1209131
14 March 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1337842
2 November 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326032
17 September 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314604
29 April 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1011660
20 March 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1007813
15 December 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1008225
24 April 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1000878
20 March 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 995914
22 March 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 985555
16 November 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 977191
22 October 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 974508

Deficiency record · 199

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2025 Resolved
A vessel of more than 19.8 meters (65 feet) in length must have at least one fire axe located in or adjacent to the primary operating station. Vessel missing fire axe on board. Must acquire fire axe within 14 days. 46 CFR 118.600
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 March 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel missing portable battery light near machinery space. Must acquire portable battery light within 14 days. 46 CFR 120.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 March 2025 Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel magnetic compass not mounted inside of wheelhouse. Vessel must properly mount magnetic compass within 14 days. 46 CFR 121.402
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Vessel photographs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2025 Resolved
A loop of tubing or a short length of flexible hose shall be installed in the fuel supply line at or near the engines. Vessel removed fixed piping with unsuitable flex hose. Vessel must replace hose with approved means within 30 days. OLD T 46 CFR 182.20-40(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 March 2025
Resolution: Received photographs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2025 Resolved
All electrical equipment and circuits must be clearly marked and identified. Vessel 12V circuit breaker in the pilot house and 32V circuit breaker in engine room not properly marked. Vessel must mark each breaker within 14 days. 46 CFR 120.220 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 March 2024 Resolved
(a) Each vessel must carry at least one rescue boat unless the cognizant OCMI determines that: (1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water... OCMI allows use of rescue platforms approved IAW NYIC 02/99. USCG MI observed crew unable to utilize Jacob's Ladder as designed/intended during MOB drill. Operator will devise a better rigging system for the operation of current rescue platform arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2024
Resolution: Block and tackle system rigged. SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2024 Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible... USCG MI did not observe charts that were up-to-date. Operator will provide receipt confirming print date of current charts and/or acquire current charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 13 March 2024
Resolution: Charts purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2024 Resolved
(b) Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines... in view of operator. USCG MI observed faulty port engine J/W gage on bridge and entire gage monitor panel was unsecured and loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
(a) All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Forward Storage room overhead wiring and light fixture not properly secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
Storage batteries. Batteries shall be checked for condition and security of stowage. The batteries in the Port & Starboard Engine room start battery boxes need to be prevented from shifting/moving in the box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
(a) Wiring. (1) All wiring shall be run as high as practicable above bilges. In the Engine room, the Port engine starting Battery box has wires running/laying in the bilge, as well as an open-ended wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 March 2024 Resolved
(a) The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05... Engine room ladder well bulkhead penetration is not properly insulated. IAW with regulation and Fire Control Plan, insulate the penetration/maintain fire boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2024 Resolved
(a) Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Both the Port and Starboard engine mounts are loose; when forward or reverse propulsion is engaged, the engines slide forward and aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 March 2024 Resolved
(a) The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05... Provide manufacturer information for installed overhead insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 13 March 2024
Resolution: Operator provided manufacturer information. SAT
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 May 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the officer in charge of marine inspections. Fire extinguisher missing from bracket in aft store room. Replace extinguisher or remove bracket. 46 CFR 181.30(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 12 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exits not marked for main deck and engine room. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2023 Resolved
Each ring life buoy on a vessel must be readily accessible and be stowed in a way it can be rapidly cast loose. Life ring on second deck was not readily accessible. 46 CFR 180.70(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 27 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have required placards posted. 46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Junction box located on the 2nd deck, port side in the overhead was not secure to the bulkhead and had exposed wire nuts. (old T) 183.10-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 19 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Junction box on the aft main deck by the emergency exit was missing the cover plate. (old T0 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not a placard stating the number of passengers permitted on the upper deck. 46 CFR 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 12 May 2023 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew was not familiar with the vessel or their duties.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 7 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(01) of the required (03) Ring Buoy's not in serviceable condition and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(03) of the required (03) Ring Buoy's retro reflective material wasted/worn and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(03) of the required (03) Ring Buoy's requires the vessels name marked on it.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022 Resolved
During the Fire Drill the hose was discovered to have a hole in the line requiring it's renewal.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 December 2022 Resolved
Vessel's Class I Watertight Door installed below deck shall have installed an indicator light for each door which warns when the door is open must be installed on the bridge.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2023
Resolved 2 January 2023
Resolution: Vessel submitted documentation attesting to the installation of the required indicator light on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 December 2021 Resolved
EACH LIFE RING BUOY MUST BE APPROVED IN ACCORDANCE WITH 46 CFR 160.050 IN SUBCHAPTER Q AND BE IN GOOD CONDITION. MI DISCOVERED THAT THE AFT LIFE RING BUOY WAS PUNCTURED WITH EXPOSED FLOATATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 December 2021 Resolved
Vessel shall meet the requirements of subpart 72.05 of sub-chapter H. Incorrect SFP insulation requires replacement in engine room. There are multiple openings in the engine room fire boundaries that require insulation. 46CFR177.10-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2022
Resolution: Received photographs of installed structural fire protection. Vessel is cleared to permit COI'd allowance for passengers. Sector NY Branch Chief will schedule to attend in person to visually view all required areas of installed structural fire protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] stranded cable installed through out boat requires removal/replacement. 46CFR183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: Vessel replaced all stranded cables with OCMI approved cables.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021 Resolved
Multiple deficiencies found not to the satisfaction of OCMI throughout vessel. Burnt/damaged wiring in galley overhead. Improperly secured/installed outlets in void #2. Top deck outlets not marine grade for outdoor use. Broken knobs and missing blanking plates on main generator switchboard. CB's in pilot house not labeled. Battery banks in engine room and pilot house not covered. Dead end wires located in fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI attended vessel to verify proper installation of electrical components.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 December 2021 Resolved
Fire stop missing throughout vessel around wire feed throughs. Ventilation dampener required on galley to accomodation air supply duct.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI attended vessel to verify proper installation of dampener and fire stop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2021 Resolved
Wet exhause hose stbd generator needs double clamp. Replace water lift on stbd generator due to improper repair. Insulate all dry exhaust piping. Port/starboard exhaust systems require overheard support.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2021 Resolved
10BC fire extinguisher missing from pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel replaced fire extinguisher in pilot house.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2021 Resolved
New wood material located in stairwell of main accomodation space. Vessel needs to provide evidence this was a replacement in kind and does not impact fire load calculations.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI verified proper installation of stairwell material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2021 Resolved
Port side top deck ring life buoy grablines need replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel replaced ring life buoy grablines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2021 Resolved
Multiple children and adult lifejackets were either not marked with a vessel name or marked with incorrect vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel properly marked all children/adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2021 Resolved
Vessel must have a rescue boat unless recovery of MOB can be visually observed from the operating station. Vessel recovered MOB from rescue platform at the stern of the vessel with no visibility for master.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel conducted MOB drill with CG presence. Vessel used stbd side side door to properly recover MOB.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2021 Resolved
Vessel currently does not have a general arrangement to verify maximum passenger capacity.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 1 February 2022
Resolution: Operator sent copy of general arrangment. Uploaded in documents section.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 October 2021 Resolved
Vessel shall meet the requirements of subpart 72.05 of sub-chapter H. Incorrect SFP insulation requires replacement in engine room. There are multiple openings in the engine room fire boundaries that require insulation. Vessel passenger capacity reduced to 150 until required insulation is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 October 2021 Resolved
Each vessel shall meet the applicable requirements of subchapter S. Water tight door in storage void does not fully shut and requires repairs/replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Operator provided photographs of operable water tight door.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
THE MARINE EMPLOYER SHALL ENSURE THAT ALL PERSONS DIRECTLY INVOLVED IN A SERIOUS MARINE INCIDENT ARE CHEMICALLY TESTED FOR EVIDENCE OF DANGEROUS DRUGS AND ALCOHOL IN ACCORDANCE WITH THE REQUIREMENTS OF 46 CFR 4.06. PROVIDE VESSEL'S WRITTEN PROTOCOLS FOR MARINE CASUALTY DRUG TESTING WITHIN DAPI PROGRAM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2019
Resolved 22 August 2019
Resolution: Received documentation via email clearing this deficiency.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOUNT AND SECURE THE #2 FOREPEAK HIGH LEVEL FLOAT SWITCH. 46 CFR 176.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2019
Resolved 22 August 2019
Resolution: Received email with pictures showing proper installation of high level alarm float switch.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOUNT AND PROPERLY SECURE THE LOUD HAILER ON THE MAST THAT IS PARTIALLY SECURED WITH ZIP TIES. 46 CFR 176.25-1 (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 August 2019 Resolved
ALL VESSELS OF LESS THAN 100 GRT - ONE MATE (EXCEPT VESSELS ON VOYAGES NOT EXCEEDING 12 HOURS IN DURATION MAY, IF THE [name withheld] TO BE SAFE, BE OPERATED WITHOUT MATES). PROVIDE SENIOR DECKHAND DESIGNATION LETTER.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. PROPERLY SECURE THE UNSECURED ANCHOR ON THE TOP DECK. 46CFR176.25-1 (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 August 2019 Resolved
EACH OUTLET OR JUNCTION BOX MUST HAVE A COVER UNLESS A FIXTURE CANOPY, SWITCH COVER, RECEPTACLE COVER OR OTHER COVER IS USED. REPLACE MISSING JUNCTION BOX COVER ON UPPER DECK STBD SIDE FWD CORNER. 46CFR111.81-3(c)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOVE DEAD END WIRE IN E/R PORT OUTBOARD SIDE @ 3RD LONGITUDINAL GIRDER NEAR "ON/OFF BOX. 46CFR176.25-1 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH OUTLET BOX MUST BE FIXED. PROPERLY SECURE DIMMABLE SWITCH ON UPPER DECK PORT SIDE ABOVE DOOR. 46CFR111.81-9 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH OUTLET BOX MUST BE FIXED. PROPERLY SECURE JUNCTION BOX UPPER DECK PORT SIDE ABOVE DOORWAY. 46CFR111.81-9 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 August 2019 Resolved
ALL PIPING, VALVES AND FITTINGS SHALL BE IAW GOOD MARINE PRACTICE AND SUITABLE FOR THE INTENDED PURPOSE. REPLACE FIRE MAIN PIPING ABOVE STBD MDE THAT HAS 02 PIN HOLE LEAKS. 46CFR181.15-5(c)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 August 2019 Resolved
ALL TOILETS AND WASH BASINS PROVIDED SHALL BE FITTED WITH ADEQUATE PLUMBING. REMOVE OR REPLACE WATER PUMP FOR TOILETS. 46CFR177-5(b)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 August 2019 Resolved
INSURE THAT SCANTLINGS, MATERIAL, FASTENINGS, WORKMANSHIP AND ARRANGEMENT OF EACH VESSEL ARE SUCH TO PROVIDE FOR SAFE OPERATION. REPAIR/REPLACE WASTED SEWAGE TANK SUPPORT BRACKET ON FWD STBD SIDE OF TANK. 46CFR177.01-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH FIXTURE GLOBE, LENS, OR DIFFUSER MUST HAVE A HIGH STRENGTH GUARD OR BE MADE OF HIGH STRENGTH MATERIAL. REPLACE BROKEN LIGHT FIXTURE IN THE AFT PART OF THE LIQUOR STORAGE ROOM. 46CFR111.75-20(B)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REROUTE WIRING FOR GALLEY AC THERMOSTAT.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 August 2018 Resolved
Replace life ring buoy in stern. 46CFR117.70(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Properly mount cables in galley and on 1st void high level alarm. 46CFR120.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Blanks on galley and main distribution panel. 46CFR120.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Repair battery cable to selector switch on starboard engine. 46CFR111.60-11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
Engineering › Bilge Water Management System › Not Operational
Issued 26 May 2017 Resolved
Demonstrate proper operation of fixed bilge dewatering system from all protected compartments.
Action required: 705 - Other - as specified
Resolved 26 May 2017
Resolution: Corrected on the spot. Vessel was eventually able to draw suction from every protected space.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2017 Resolved
Complete credit DD/ISE prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2017
Resolution: Vessel has had a credit DD/ISE and is cleared to operate with passengers.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 29 March 2016 Resolved
Provide proof of MMSI # properly programmed into radio equipment and AIS.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 15 September 2016
Resolution: MMSI entered
Engineering › Fuel Oil Service System › Filter
Issued 29 March 2016 Resolved
Install fuel filter bowl on port MDE.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 15 September 2016
Resolution: Bowl installed
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 March 2016 Resolved
Install 2 emergency lights.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 September 2016
Resolution: Lights installed and tested
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 August 2015 Resolved
Remove 02 deadend cables outside Engine Room.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Construction/Loadline › Penetrations › Gasket
Issued 13 August 2015 Resolved
Renew Engine Room escape scuttle gasket.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Engineering › Compressed Air System (control) › Valve
Issued 13 August 2015 Resolved
Install relief valve on blue bladder tank in Port Side of Engine Room.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 August 2015 Resolved
Clean up loose wires on the starboard exhaust fan.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 August 2015 Resolved
Prove proper payment of User Fees.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Lifesaving › Lifebuoys › Serviceable
Issued 13 August 2015 Resolved
Replace life ring on Starboard bridge wing.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 13 August 2015 Resolved
Replace outlet cover behind bar on 2nd deck.
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 29 March 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 December 2014 Resolved
AB02: Sewage tank vent is wasted and must be replaced in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2015
Resolution: MI inspected newly installed sewage tank vent, vent pipe was new, secure and intact.
Construction/Loadline › Hull › Bottom Plating
Issued 14 October 2014 Resolved
Owner must complete UT belt gauging of the hull to ensure acceptable thickness and ensure no other areas of significant corrosion exist. Ultra Sonic testing will be completed to the satisfaction of the attending [name withheld] activity 5012639 for details
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2014
Resolution: Nav arch conducted UT belt gauging of hull, all sat.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 October 2014 Resolved
AB01: During DD/ISE and repair of hull plate in engine room it was noticed that main switch panel box for MDE batteries is wasted and could cause an electrical hazard. Must replace in kind or submit drawings, material list, and plans to SECNY for approval and conduct operational function test with USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2015
Resolved 8 May 2015
Resolution: MI reviewed plans of the newly installed switch panel and approved design. Installation was to the satisfaction of the attending MI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 August 2014 Resolved
Prove payment of user fees.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2014
Resolution: Received E-Mail from FINCEN showing that User Fees are current.
Lifesaving › Lifebuoys › Serviceable
Issued 5 August 2014 Resolved
Replace Port Side ring buoy
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 12 August 2014
Resolution: Ring buoy replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 August 2014 Resolved
Replace expired items in First Aid Kit (Aspirin & Ammonia Inhalant).
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 22 August 2014
Resolution: Verified expired items replaced.
Construction/Loadline › Structures › Door
Issued 5 August 2014 Resolved
Make permanent repairs to Fire Doors.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 22 August 2014
Resolution: verified satisfactory repair and operation of fire doors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 August 2014 Resolved
Remove dead end wiring (transducer) from space forward of Engine Room
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 12 August 2014
Resolution: Wiring removed
Engineering › Reduction Gearing/Clutches › Bolt
Issued 5 August 2014 Resolved
Replace cotter pins on steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2014
Resolution: Corrected on the spot
Navigation › Piloting/Steering › Marine Charts
Issued 11 May 2012 Resolved
HA02-vessel must provide current charts for operating area.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 18 June 2012
Resolution: Vessel provided charts.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2012 Resolved
HA03-Post visible placard for Emergency Escape Hatch
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 18 June 2012
Resolution: Vessel posted placard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2012 Resolved
HA04-Post signage on liquor hold side for water tight door.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 18 June 2012
Resolution: Vessel posted signage.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2012 Resolved
HA05-Install Guard on light in general hold.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 18 June 2012
Resolution: Light guard installed on guard.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 May 2012 Resolved
HA07-Permanently install wires for lights up to second deck in way of ice Maker.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 18 June 2012
Resolution: Permanently installed wires for lights.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 May 2012 Resolved
HA08- Remove oil from bilges in Engine Room.
Action required: 705 - Other - as specified
Due 6 June 2012
Resolved 18 June 2012
Resolution: Oil removed from bilges.
Documentation › Certificates/Documents › FCC SSL
Issued 20 April 2009 Resolved
Provide a Bridge to Bridge Radiotelephony Certificate.
Due 20 May 2009
Resolved 24 April 2009
Resolution: A new certificate was issued to the vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 April 2009 Resolved
Demonstrate proper operation of all bilge high water alarms.
Due 20 May 2009
Resolved 24 April 2009
Resolution: All bilge high water alarms were tested and found satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 April 2009 Resolved
Properly label all circuit breakers for two distribution panels located in the wheelhouse. All breakers not in service should be removed from the panel and properly blanked off.
Due 20 May 2009
Resolved 24 April 2009
Resolution: All breakers were labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2009 Resolved
Remove extention cords from the bar service area located on the upper deck.
Due 20 May 2009
Resolved 24 April 2009
Resolution: All extention cords were removed as directed.
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 20 April 2009 Resolved
Make repairs to the starboard side generator RPM indicator located in the engine room and demonstrate proper operation of the same.
Due 20 May 2009
Resolved 14 May 2009
Resolution: Received technicians report from the vessel representative documenting the repairs conducted on the RPM Tachometer.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 August 2008 Resolved
Provide cover for the A/C condenser
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 8 September 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 August 2008 Resolved
Provide onboard an additional 66 Adult Type 1 PFD's and 9 Child Type 1 PFD's and label each with vessel's name in accordance with 46 CFR 122.604.
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 7 August 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 August 2008 Resolved
Replace main circuit panel knobs (engine room).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 18 September 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 7 August 2008 Resolved
Replace hose (flex hose) for toilets which connect to salt water pump.
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 8 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 August 2008 Resolved
Properly label all PFD stowage areas with proper number of jackets in each.
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 8 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 August 2008 Resolved
Remove expired/unneeded EPIRB from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2008
Resolved 7 August 2008
Stability › Incline Test › General
Issued 25 May 2007 Resolved
Based on the weight changes submitted to this office on 11MAY2007 Your vessel has experienced a total aggregate weight change in excess of 10% of the approved lightship displacement. In accordance with Marine Safety Center Technical Note 04-95 you are required to conduct a full stability test.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 3 July 2008
Resolution: Incline stability test completed. MSC stability letter isued this date.
Stability › Incline Test › General
Issued 25 May 2007 Resolved
Based on the Marine Safety Center (MSC) review of your calculations your total passenger count is reduced to 325, and the maximum number of passengers carried on the upper deck is 200. This restriction remains in affect until a new stability letter is issued by MSC
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 3 July 2008
Resolution: Incline stability test completed. MSC stability letter issued this date.
Stability › Incline Test › General
Issued 25 May 2007 Resolved
Based on you weight change calculations your vessel is damage sensitive aft. It is imperative your vessel remain in compliance with the draft restrictions on your stability letter (paragraph 3). Prior to getting underway you are required to measure you freeboard to ensure compliance with the draft restrictions and log the readings.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 3 July 2008
Resolution: Incline stability test completed. MSC stability letter issued this date.
Stability › Incline Test › General
Issued 25 May 2007 Resolved
The above requirements must be completed no later than 31OCT2007, at which time the vessel will no longer be allowed to operate with passengers.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 3 July 2008
Resolution: Incline stability test completed. MSC stability letter issued this date.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 7 May 2007 Resolved
Reinstall missing fire boundary insulation around door to crew quarters.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Insulation replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring for chest freezer outlet in crew quarters with metal supports every 24 inches.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Supports installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 May 2007 Resolved
Replace missing junction box cover in crew quarters port side on overhead.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: J-box cover installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring in crew quarters forward bulkhead and aft bulkhead at light fixture with metal supports every 24 inches.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Metal supports installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring for fresh water pumps in liquor room with metal supports every 24 inches.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Metal supports installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Remove or properly enclose dead end cable in engine space above starboard generator behind distribution panel.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Cable placed in enclosure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring in engine space with metal supports every 24 inches at: starboard side battery charger cables; starboard side cables running to distribution panel; and wire port side aft and along aft bulkhead.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Metal supports installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring for bilge high level alarm in forepeak with metal supports every 24 inches.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Metal supports installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2007 Resolved
Secure wiring in life jacket locker on upper deck with metal supports every 24 inches.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Metal supports installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 May 2007 Resolved
Permanently secure AC enclosure near aft stairwell on main deck.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: Enclosure secured.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 May 2007 Resolved
Two child-size life jackets were not in serviceable condition. Number of children allowed onboard is reduced to 35 until this requirement is met.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 22 June 2007
Resolution: 2 new jackets obtained.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 May 2007 Resolved
Properly mark engine room escape hatch in engine room and on main deck. CLEARED ON BOARD.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 7 May 2007
Resolution: Signs posted for markings.
Lifesaving › Lifefloat › Not on Board
Issued 26 May 2006 Resolved
Vessel has removed all of the primary lifesaving . The vessels route is restricted to Lakes, Bays, and Sounds no more than one mile from shore. 46CFR117.207(d)
Action required: 705 - Other - as specified
Resolved 7 May 2007
Resolution: The restriction has been added to the new COI activity # 2830480
Fire Fighting › Means of Escape › Stairways
Issued 26 May 2006 Resolved
The forward fire doors do not meet the means of escape requirements outlined in 46 CFR 116.500(i). The owner must install a panic bar and prove proper operation to the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 19 September 2006
Fire Fighting › Means of Escape › Stairways
Issued 26 May 2006 Resolved
Until the item # PT03 is satisfied you must provide one extra crewmember (in addition to what is required by your COI), who's sole duty is to open the forward fire door incase of an emergency.
Action required: 705 - Other - as specified
Resolved 19 September 2006
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 May 2006 Resolved
Remove the carpet from under the aft fire door.
Due 11 August 2006
Resolved 11 August 2006
Resolution: Received a FAX from [name withheld] lic.# 1078824 stating item has been corrected
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 18 May 2006 Resolved
Provide a descrition of work being done to second deck.
Due 29 May 2006
Resolved 11 August 2006
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 18 May 2006 Resolved
Provide list of materials being installed on second deck.
Due 29 May 2006
Resolved 11 August 2006
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 18 May 2006 Resolved
Provide flammability characteristics of materials being installed on second deck.
Due 29 May 2006
Resolved 11 August 2006
Stability › Incline Test › General
Issued 18 May 2006 Resolved
Provide total amount of weight removed and added to second deck.
Due 29 May 2006
Resolved 11 August 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 May 2005 Resolved
Prove proper operation of holding tank room high level bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 20 May 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 May 2005 Resolved
Replace 2 waterlights on LifeRafts
Due 3 June 2005
Resolved 20 May 2005
Lifesaving › Lifefloat › Paddle
Issued 19 May 2005 Resolved
Label all paddles with vessels name.
Due 3 June 2005
Resolved 20 May 2005
Documentation › Markings/Placards › Capacity Marking
Issued 19 May 2005 Resolved
Label UD with max pass (200).
Due 3 June 2005
Resolved 2 June 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 May 2005 Resolved
Provide fire control plan.
Due 3 June 2005
Resolved 2 June 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 19 May 2005 Resolved
Provide a station bill.
Due 3 June 2005
Resolved 2 June 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 May 2005 Resolved
Designate senior deckhands in writing.
Due 3 June 2005
Resolved 2 June 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 October 2003 Resolved
COMPLETE REQUIRED DRILLS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 9 June 2004
Resolution: Completed satisfactory fire and MOB drills.
Documentation › Certificates/Documents › Stability Letter
Issued 16 October 2003 Resolved
PROVIDE COPY OF APPROVED STABILTY LTR TO LOCAL COTP/[name withheld] PASSENGERS.
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 10 June 2004
Resolution: Faxed copy of stability letter provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 October 2003 Resolved
PROVIDE PROOF OF EPIRB REGISTRATION AND HYDROSTATIC RELEASE EXPIRY DATE.
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 9 June 2004
Resolution: EPIRB properly registered and hydrostatic release documentation provided.
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 October 2003 Resolved
PRESENT VSL TO NYCMI NEW YORK FOR NEW TO ZONE INSPECTION UPON ARRIVAL AND PRIOR TO CONDUCTING PASSENGER OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2004
Resolved 9 June 2004
Resolution: NTZ exam completed.
Lifesaving › Buoyant Apparatus
Issued 30 July 2002 Resolved
Provide three floating water lights. LEGACY COMPONENT DESC: Floating light
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2002
Resolved 31 July 2002
Communications › Radio Communications
Issued 30 July 2002 Resolved
Provide new EPIRB hydrstatic release mechanism. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2002
Resolved 31 July 2002
Electrical › Electric Generation Source (service)
Issued 30 July 2002 Resolved
Provide plan to comply with 46CFR183.10-5(f). LEGACY COMPONENT DESC: Generator rating
Condition: Unknown
Due 15 August 2002
Resolved 23 August 2002
Resolution: Survey was conducted by Wards Electric, results indicated circuit breakers are derated to 80%
Electrical › Electrical Distribution System (service)
Issued 30 July 2002 Resolved
Remove obsolete power panels and switchboards as discusssed with CG Inspector. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 30 August 2002
Resolved 1 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 30 July 2002 Resolved
Relocate emergency escape hatch key for engine room and label hatch. LEGACY COMPONENT DESC: Emergency Escape
Condition: Placed in Improper Service
Due 1 August 2002
Resolved 1 August 2002
Engineering
Issued 2 August 2001 Resolved
Repair/replace deteriorated fuel hoses.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Construction/Loadline
Issued 2 August 2001 Resolved
Provide correct/approved hose for bilge system with proper connections.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Engineering
Issued 2 August 2001 Resolved
Provide missing flame shields for Racor filters.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Construction/Loadline
Issued 2 August 2001 Resolved
Provide permanent closure where it is blanked-off at the hull penetration.,
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Construction/Loadline
Issued 2 August 2001 Resolved
Repair identified leaking areas on Bridge by marine inspector.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Lifesaving
Issued 2 August 2001 Resolved
Provide missing sea rails on stove top.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Electrical
Issued 2 August 2001 Resolved
Provide adequate emergency lighting and signs as identified by marine inspector.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Construction/Loadline
Issued 2 August 2001 Resolved
Repair deteriorated engine room vents on open deck where rain gets into engine room.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Accommodation/Occupational Safety
Issued 2 August 2001 Resolved
Provide means of opening escape hatch located on main deck.
Condition: Unknown
Due 27 August 2001
Resolved 29 August 2001
Documentation
Issued 2 August 2001 Resolved
Current fire plan.
Condition: Unknown
Due 27 August 2001
Resolved 29 August 2001
Documentation
Issued 2 August 2001 Resolved
Provide current Station Bill.
Condition: Unknown
Due 27 August 2001
Resolved 29 August 2001
Lifesaving
Issued 2 August 2001 Resolved
Provide wWeak link for LFs with the proper breaking strength.
Condition: Unknown
Due 27 August 2001
Resolved 29 August 2001
Navigation
Issued 31 July 2000 Resolved
OUTDATED CHARTS AND LIGHT LIST
Condition: Unknown
Due 3 August 2000
Resolved 8 August 2000
Lifesaving
Issued 31 July 2000 Resolved
OARS FOR LIFE RAFT NEED TO BE RE-STENCILED
Condition: Unknown
Due 3 August 2000
Resolved 8 August 2000
Lifesaving
Issued 31 July 2000 Resolved
CLEAR PLASTIC LIGHT COVERS ARE CRACKED
Condition: Unknown
Due 3 August 2000
Resolved 8 August 2000
Lifesaving
Issued 31 July 2000 Resolved
Life jacket reflective tape worn.
Condition: Unknown
Due 3 August 2000
Resolved 8 August 2000
Lifesaving
Issued 31 July 1997 Resolved
INSTALL EPIRB IN A FLOAT FREE MANNER PRIOR TO CARRYING PASSENGERS OUTSIDE THREE NM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Electrical
Issued 31 July 1997 Resolved
PROPERLY CAP LOOSE/DEAD-END CABLES IN ENGINE COMPARTMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Deck/Cargo
Issued 31 July 1997 Resolved
INSTALL VESSEL'S ANCHOR IN READY USE CONDITION, MINIMUM 150' OF LINE, AND PROPERLY SECURE TO VSL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Navigation
Issued 31 July 1997 Resolved
PROVIDE PROPER WATERPROOF CASE/PROPER LABELING FOR DISTRESS SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
PROPERLY SECURE ALL PADDLES FOR LIFEFLOATS TO THE RESPECTIVE PRIMARY DEVICES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Electrical
Issued 31 July 1997 Resolved
INSTALL BATTERY CUTOFFS FOR ALL BATTERY INSTALLATIONS, (SPECIFICALLY, PORT GENERATOR START BATTERY)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
DETERMINE REASON/CAUSE FOR 18"X18" PLYWOOD PATCH ON MSD TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Fire Fighting
Issued 31 July 1997 Resolved
PROVIDE BRONZE OR EQUIVALENT UL STANDARD DUAL PURPOSE NOZZLES FOR ALL FIRE STATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR ALL REQUIRED RING BUOYS/PROPERLY ATTACH WATERLIGHT W/ SNAPHOOK.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
INSTALL BATTENS BETWEEN ALL L/F, BAs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 15 August 1995 Resolved
Repair area around aft stbd chock.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
Clean and prepare for inspection area around shaft sleeves & make ready forinspection.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
Repair area wasted on side plate, 4th panel aft of port side opening.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
Clean sludge from around eng room bilge suction & sea chest area.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Lifesaving
Issued 10 August 1995 Resolved
Attach Water Light to ring bouy by seperate painter.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Lifesaving
Issued 10 August 1995 Resolved
Provide 6 additional adult PFDs & 2 child size. Number of total persons reduced to 357 until item corrected.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Electrical
Issued 10 August 1995 Resolved
Mount watertight door warning light.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Documentation
Issued 10 August 1995 Resolved
Provide pollution placard for eng compt._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Electrical
Issued 22 September 1993 Resolved
120V CIRCUT PANEL ON THE BRIDGE MISSING A BLANK._x001C_
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
LIFEJACKET DONNING INSTRUCTIONS WERE NOT PROVIDED._x001C_
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Navigation
Issued 22 September 1993 Resolved
STEERING CABLE NOT GREASED_x001C_
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Unknown
Issued 22 September 1993 Resolved
DRUG TEST RECORDS NOT AVAILABLE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Documentation
Issued 25 February 1992 Resolved
PROVIDE A WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Engineering
Issued 25 February 1992 Resolved
8: PROVIDE PROPER OPERATION OF LOW LUBE OIL TRIPS WITH AUDIBLE AND VISUAL ALARMS FOR EACH S/S DIESEL GENERATOR.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Engineering
Issued 25 February 1992 Resolved
9: PROVE PROPER OPERATION OF OVER SPEED TRIPS FOR EACH S/S DIESEL GENERATOR
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Lifesaving
Issued 25 February 1992 Resolved
3: REPAIR OR REPLACE ALL RAT DAMAGED LIFE PRESERVERS WITH APPROVED MANUFACTORER'S REPAIR KIT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Lifesaving
Issued 25 February 1992 Resolved
1: PROVIDE (28) ADULT AND (1) CHILD SIZE TYPE 1 LIFE JACKETS._x001C_ _x001C_ VSL IS RESTRICTED TO 335 TOTAL PERSONS UNTIL THIS REQUIREMENT IS MET._x001C_ _x001C_
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Accommodation/Occupational Safety
Issued 25 February 1992 Resolved
4: PROVIDE SUITABLE LATCH FOR OVEN DOOR.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Lifesaving
Issued 25 February 1992 Resolved
5: PROVIDE AND EQUIP ALL BUOYANT APPARATUS AND LIFE FLOAT INSTALLATIONS IN ACCORDANCE WITH 46 CFR 180.15 AND 180.20. VSL IS RESTRICTED TO LAKES,BAYS,AND SOUNDS,NOT MORE THAN 1 MILE FROM SHORE ON THE INTRACOASTAL WATERWAY, MELBOURNE,FLORIDA TO 1 MILE SOUTH OF RICKENBACKER CAUSEWAY MIAMI, FLORIDA.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Accommodation/Occupational Safety
Issued 25 February 1992 Resolved
6: PROPERLY SECURE REFRIGERATORS FROM MOVEMENT.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Fire Fighting
Issued 25 February 1992 Resolved
7: PROVIDE PORTABLE HAND FIRE/BILGE PUMP WITH SUITABLE HOSE IN ACCORDANCE WITH 46 CFR 181.10-5.
Condition: Unknown
Due 25 February 1992
Resolved 25 February 1992
Engineering
Issued 28 September 1990 Resolved
PROVIDE A SUITABLE BILGE SUCTION STRAINER THAT IS AT LEAST THREE TIMES THE DIAMETER OF THE BILGE PIPE IAW 46CRF 182.25-5(B).
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Construction/Loadline
Issued 28 September 1990 Resolved
PROVIDE A DETAILED U.T. REPORT SHOWING THE LOCATION AND HULL THICKNESS AT EACH LOCATION.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Construction/Loadline
Issued 28 September 1990 Resolved
PROVIDE ORIGINAL HULL THICKNESS OF THE PLATES.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Electrical
Issued 28 September 1990 Resolved
PROVIDE A BATTERY BOX WITH A SUITABLE NON-CORROSIVE LINER FOR THE PORT DIESEL GENERATOR AND BLOCK FROM MOVEMENT.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Accommodation/Occupational Safety
Issued 28 September 1990 Resolved
CROP OUT AND INSERT THE WASTED AREA ON THE MSD HOLDING TANK WITH STEEL OF THE SAME DEMENSION.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Accommodation/Occupational Safety
Issued 19 October 1989 Resolved
REMOVE OVEN FROM GALLEY IAW OCMI 28AUG89 LETTER.
Condition: Unknown
Due 19 October 1989
Resolved 19 October 1989
Documentation
Issued 19 October 1989 Resolved
SUPPLY AS BUILT PLANS FOR GALLEY/ACCOMODATION INSTALLATION AT STERN OF VESSEL. THIS SHOULD INCLUDE THE ELECTRICAL PLANS FOR THE GALLEY.
Condition: Unknown
Due 19 October 1989
Resolved 19 October 1989
Accommodation/Occupational Safety
Issued 13 March 1989 Resolved
REMOVE ALL STORES FROM VOID SPACES PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Navigation
Issued 24 April 1986 Resolved
REPLACE BOTH RUDDER CUTLASS BEARINGS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 24 April 1986 Resolved
REPLACE BROKEN WINDOWS AT STBD SIDE OF PILOT HOUSE AND MAIN DECK, PORT, SECOND FROM STERN.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Accommodation/Occupational Safety
Issued 24 April 1986 Resolved
REPAIR FRACTURED HADN RAIL AND BROKEN WELD AT BASE OF HAND RAIL SUPPORT, PORT AFT CORNER OF UPPER DECK.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 20 March 1986 Resolved
RENEW PORT SIDE STERN, MAIN DECK MOORING BITT.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Lifesaving
Issued 22 October 1984 Resolved
HAVE NAME AND CAPACITY OF PERSONS STENCILED ON BUOYANT APPARATUS WHERE NECESSARY. ALSO REMOVE NAMES OF OTHER VESSELS THAT WERE PREVIOUSLY STENCILED ON APPARATUS.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984
Construction/Loadline
Issued 22 October 1984 Resolved
REPLACE 3 BROKEN PANES OF GLASS ON PORT SIDE AND 3 BROKEN PANES OF GLASS STARBOARD SIDE. ALSO REMOVE GLASS PANES FROM WINDOWS 2,3,5,6 AND 7 ON BOTH PORT AND STARBOARD SIDES FOR EXAMINATION OF WINDOW PANES.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984
Lifesaving
Issued 22 October 1984 Resolved
REPLACE ONE (1) WATERLIGHT FOR BUOYANT APPARATUS ON CANOPY DECK.
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.