MAURY USCG vessel records
← All vessels

ECLIPSE

ECLIPSE is a 1972 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in April 2025, along with 64 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 29 April 2025.

Built
1972
Last inspected
29 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC5562
Flag
UNITED STATES
Maury page id
psix-47167

Documentation record

Registered dimensions (L × B × D)79.9 ft × 27.2 ft × 9.7 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUT MARINE CORP · WARREN, RI, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 64 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

29 April 2025 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123035
6 March 2025 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8088977
23 December 2024 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8050554
3 September 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7994860
4 March 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7872458
12 May 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7686766
12 May 2023 Special Consideration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7686833
22 March 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655027
13 December 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601245
27 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331750
3 June 2021 Drydock Exam · Hull Examination · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7214732
6 July 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6998552
21 August 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6790211
30 April 2019 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672548
21 August 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6518487
25 May 2017 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6155739
3 May 2017 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6134723
27 January 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6078257
29 March 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842584

Deficiency record · 64

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2025 Resolved
A vessel of more than 19.8 meters (65 feet) in length must have at least one fire axe located in or adjacent to the primary operating station. Vessel missing fire axe on board. Must acquire fire axe within 14 days. 46 CFR 118.600
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 March 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel missing portable battery light near machinery space. Must acquire portable battery light within 14 days. 46 CFR 120.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 March 2025 Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel magnetic compass not mounted inside of wheelhouse. Vessel must properly mount magnetic compass within 14 days. 46 CFR 121.402
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Vessel photographs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2025 Resolved
A loop of tubing or a short length of flexible hose shall be installed in the fuel supply line at or near the engines. Vessel removed fixed piping with unsuitable flex hose. Vessel must replace hose with approved means within 30 days. OLD T 46 CFR 182.20-40(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 March 2025
Resolution: Received photographs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 March 2025 Resolved
All electrical equipment and circuits must be clearly marked and identified. Vessel 12V circuit breaker in the pilot house and 32V circuit breaker in engine room not properly marked. Vessel must mark each breaker within 14 days. 46 CFR 120.220 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Received photographs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 March 2024 Resolved
(a) Each vessel must carry at least one rescue boat unless the cognizant OCMI determines that: (1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water... OCMI allows use of rescue platforms approved IAW NYIC 02/99. USCG MI observed crew unable to utilize Jacob's Ladder as designed/intended during MOB drill. Operator will devise a better rigging system for the operation of current rescue platform arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2024
Resolution: Block and tackle system rigged. SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2024 Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible... USCG MI did not observe charts that were up-to-date. Operator will provide receipt confirming print date of current charts and/or acquire current charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 13 March 2024
Resolution: Charts purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2024 Resolved
(b) Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines... in view of operator. USCG MI observed faulty port engine J/W gage on bridge and entire gage monitor panel was unsecured and loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
(a) All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Forward Storage room overhead wiring and light fixture not properly secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
Storage batteries. Batteries shall be checked for condition and security of stowage. The batteries in the Port & Starboard Engine room start battery boxes need to be prevented from shifting/moving in the box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2024 Resolved
(a) Wiring. (1) All wiring shall be run as high as practicable above bilges. In the Engine room, the Port engine starting Battery box has wires running/laying in the bilge, as well as an open-ended wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 March 2024 Resolved
(a) The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05... Engine room ladder well bulkhead penetration is not properly insulated. IAW with regulation and Fire Control Plan, insulate the penetration/maintain fire boundary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2024 Resolved
(a) Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Both the Port and Starboard engine mounts are loose; when forward or reverse propulsion is engaged, the engines slide forward and aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 1 April 2024
Resolution: Recieved objective photographic evidence that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 March 2024 Resolved
(a) The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05... Provide manufacturer information for installed overhead insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2024
Resolved 13 March 2024
Resolution: Operator provided manufacturer information. SAT
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 May 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the officer in charge of marine inspections. Fire extinguisher missing from bracket in aft store room. Replace extinguisher or remove bracket. 46 CFR 181.30(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 12 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exits not marked for main deck and engine room. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2023 Resolved
Each ring life buoy on a vessel must be readily accessible and be stowed in a way it can be rapidly cast loose. Life ring on second deck was not readily accessible. 46 CFR 180.70(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 27 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have required placards posted. 46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Junction box located on the 2nd deck, port side in the overhead was not secure to the bulkhead and had exposed wire nuts. (old T) 183.10-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 19 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Junction box on the aft main deck by the emergency exit was missing the cover plate. (old T0 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not a placard stating the number of passengers permitted on the upper deck. 46 CFR 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 23 May 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 12 May 2023 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew was not familiar with the vessel or their duties.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2023
Resolved 7 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(01) of the required (03) Ring Buoy's not in serviceable condition and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(03) of the required (03) Ring Buoy's retro reflective material wasted/worn and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2022 Resolved
(03) of the required (03) Ring Buoy's requires the vessels name marked on it.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2022 Resolved
During the Fire Drill the hose was discovered to have a hole in the line requiring it's renewal.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 28 December 2022
Resolution: Operator submitted documentation attesting to correction of the listed deficiency.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 December 2022 Resolved
Vessel's Class I Watertight Door installed below deck shall have installed an indicator light for each door which warns when the door is open must be installed on the bridge.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2023
Resolved 2 January 2023
Resolution: Vessel submitted documentation attesting to the installation of the required indicator light on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 December 2021 Resolved
EACH LIFE RING BUOY MUST BE APPROVED IN ACCORDANCE WITH 46 CFR 160.050 IN SUBCHAPTER Q AND BE IN GOOD CONDITION. MI DISCOVERED THAT THE AFT LIFE RING BUOY WAS PUNCTURED WITH EXPOSED FLOATATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 December 2021 Resolved
Vessel shall meet the requirements of subpart 72.05 of sub-chapter H. Incorrect SFP insulation requires replacement in engine room. There are multiple openings in the engine room fire boundaries that require insulation. 46CFR177.10-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2022
Resolution: Received photographs of installed structural fire protection. Vessel is cleared to permit COI'd allowance for passengers. Sector NY Branch Chief will schedule to attend in person to visually view all required areas of installed structural fire protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] stranded cable installed through out boat requires removal/replacement. 46CFR183.01-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: Vessel replaced all stranded cables with OCMI approved cables.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021 Resolved
Multiple deficiencies found not to the satisfaction of OCMI throughout vessel. Burnt/damaged wiring in galley overhead. Improperly secured/installed outlets in void #2. Top deck outlets not marine grade for outdoor use. Broken knobs and missing blanking plates on main generator switchboard. CB's in pilot house not labeled. Battery banks in engine room and pilot house not covered. Dead end wires located in fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI attended vessel to verify proper installation of electrical components.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 December 2021 Resolved
Fire stop missing throughout vessel around wire feed throughs. Ventilation dampener required on galley to accomodation air supply duct.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI attended vessel to verify proper installation of dampener and fire stop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2021 Resolved
Wet exhause hose stbd generator needs double clamp. Replace water lift on stbd generator due to improper repair. Insulate all dry exhaust piping. Port/starboard exhaust systems require overheard support.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2021 Resolved
10BC fire extinguisher missing from pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel replaced fire extinguisher in pilot house.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2021 Resolved
New wood material located in stairwell of main accomodation space. Vessel needs to provide evidence this was a replacement in kind and does not impact fire load calculations.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 14 January 2022
Resolution: MI verified proper installation of stairwell material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2021 Resolved
Port side top deck ring life buoy grablines need replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel replaced ring life buoy grablines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2021 Resolved
Multiple children and adult lifejackets were either not marked with a vessel name or marked with incorrect vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel properly marked all children/adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2021 Resolved
Vessel must have a rescue boat unless recovery of MOB can be visually observed from the operating station. Vessel recovered MOB from rescue platform at the stern of the vessel with no visibility for master.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 28 December 2021
Resolution: Vessel conducted MOB drill with CG presence. Vessel used stbd side side door to properly recover MOB.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2021 Resolved
Vessel currently does not have a general arrangement to verify maximum passenger capacity.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 1 February 2022
Resolution: Operator sent copy of general arrangment. Uploaded in documents section.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 October 2021 Resolved
Vessel shall meet the requirements of subpart 72.05 of sub-chapter H. Incorrect SFP insulation requires replacement in engine room. There are multiple openings in the engine room fire boundaries that require insulation. Vessel passenger capacity reduced to 150 until required insulation is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2022
Resolved 6 January 2022
Resolution: Operator sent sufficient evidence of deficiency rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 October 2021 Resolved
Each vessel shall meet the applicable requirements of subchapter S. Water tight door in storage void does not fully shut and requires repairs/replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Operator provided photographs of operable water tight door.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
THE MARINE EMPLOYER SHALL ENSURE THAT ALL PERSONS DIRECTLY INVOLVED IN A SERIOUS MARINE INCIDENT ARE CHEMICALLY TESTED FOR EVIDENCE OF DANGEROUS DRUGS AND ALCOHOL IN ACCORDANCE WITH THE REQUIREMENTS OF 46 CFR 4.06. PROVIDE VESSEL'S WRITTEN PROTOCOLS FOR MARINE CASUALTY DRUG TESTING WITHIN DAPI PROGRAM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2019
Resolved 22 August 2019
Resolution: Received documentation via email clearing this deficiency.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOUNT AND SECURE THE #2 FOREPEAK HIGH LEVEL FLOAT SWITCH. 46 CFR 176.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2019
Resolved 22 August 2019
Resolution: Received email with pictures showing proper installation of high level alarm float switch.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOUNT AND PROPERLY SECURE THE LOUD HAILER ON THE MAST THAT IS PARTIALLY SECURED WITH ZIP TIES. 46 CFR 176.25-1 (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 August 2019 Resolved
ALL VESSELS OF LESS THAN 100 GRT - ONE MATE (EXCEPT VESSELS ON VOYAGES NOT EXCEEDING 12 HOURS IN DURATION MAY, IF THE [name withheld] TO BE SAFE, BE OPERATED WITHOUT MATES). PROVIDE SENIOR DECKHAND DESIGNATION LETTER.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. PROPERLY SECURE THE UNSECURED ANCHOR ON THE TOP DECK. 46CFR176.25-1 (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 August 2019 Resolved
EACH OUTLET OR JUNCTION BOX MUST HAVE A COVER UNLESS A FIXTURE CANOPY, SWITCH COVER, RECEPTACLE COVER OR OTHER COVER IS USED. REPLACE MISSING JUNCTION BOX COVER ON UPPER DECK STBD SIDE FWD CORNER. 46CFR111.81-3(c)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REMOVE DEAD END WIRE IN E/R PORT OUTBOARD SIDE @ 3RD LONGITUDINAL GIRDER NEAR "ON/OFF BOX. 46CFR176.25-1 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH OUTLET BOX MUST BE FIXED. PROPERLY SECURE DIMMABLE SWITCH ON UPPER DECK PORT SIDE ABOVE DOOR. 46CFR111.81-9 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH OUTLET BOX MUST BE FIXED. PROPERLY SECURE JUNCTION BOX UPPER DECK PORT SIDE ABOVE DOORWAY. 46CFR111.81-9 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 August 2019 Resolved
ALL PIPING, VALVES AND FITTINGS SHALL BE IAW GOOD MARINE PRACTICE AND SUITABLE FOR THE INTENDED PURPOSE. REPLACE FIRE MAIN PIPING ABOVE STBD MDE THAT HAS 02 PIN HOLE LEAKS. 46CFR181.15-5(c)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 August 2019 Resolved
ALL TOILETS AND WASH BASINS PROVIDED SHALL BE FITTED WITH ADEQUATE PLUMBING. REMOVE OR REPLACE WATER PUMP FOR TOILETS. 46CFR177-5(b)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 August 2019 Resolved
INSURE THAT SCANTLINGS, MATERIAL, FASTENINGS, WORKMANSHIP AND ARRANGEMENT OF EACH VESSEL ARE SUCH TO PROVIDE FOR SAFE OPERATION. REPAIR/REPLACE WASTED SEWAGE TANK SUPPORT BRACKET ON FWD STBD SIDE OF TANK. 46CFR177.01-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
EACH FIXTURE GLOBE, LENS, OR DIFFUSER MUST HAVE A HIGH STRENGTH GUARD OR BE MADE OF HIGH STRENGTH MATERIAL. REPLACE BROKEN LIGHT FIXTURE IN THE AFT PART OF THE LIQUOR STORAGE ROOM. 46CFR111.75-20(B)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019 Resolved
INSPECTION SHALL BE IAW STANDARDS ACCEPTABLE AS GOOD MARINE PRACTICE. REROUTE WIRING FOR GALLEY AC THERMOSTAT.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Received pictures rectifying outstanding deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 August 2018 Resolved
Replace life ring buoy in stern. 46CFR117.70(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Properly mount cables in galley and on 1st void high level alarm. 46CFR120.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Blanks on galley and main distribution panel. 46CFR120.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2018 Resolved
Repair battery cable to selector switch on starboard engine. 46CFR111.60-11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2018
Resolved 4 September 2018
Resolution: CG OK
Engineering › Bilge Water Management System › Not Operational
Issued 26 May 2017 Resolved
Demonstrate proper operation of fixed bilge dewatering system from all protected compartments.
Action required: 705 - Other - as specified
Resolved 26 May 2017
Resolution: Corrected on the spot. Vessel was eventually able to draw suction from every protected space.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2017 Resolved
Complete credit DD/ISE prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2017
Resolution: Vessel has had a credit DD/ISE and is cleared to operate with passengers.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 29 March 2016 Resolved
Provide proof of MMSI # properly programmed into radio equipment and AIS.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 15 September 2016
Resolution: MMSI entered
Engineering › Fuel Oil Service System › Filter
Issued 29 March 2016 Resolved
Install fuel filter bowl on port MDE.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 15 September 2016
Resolution: Bowl installed
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 March 2016 Resolved
Install 2 emergency lights.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 September 2016
Resolution: Lights installed and tested

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.