Records from 2007 to 2026. Most recent: inspection, 26 January 2026.
Inspection history · 24
26 January 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8301611
28 October 2024
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024094
18 September 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999465
20 September 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7795299
25 April 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7676797
14 December 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609101
23 September 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7318634
30 August 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7300307
27 August 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7298132
4 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7049840
5 December 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6868853
24 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841181
10 June 2019
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6709156
20 May 2019
Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6688332
12 September 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6538856
11 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6537675
20 November 2017
Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6310214
26 October 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6295619
22 September 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6272621
8 August 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6235046
22 September 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6007586
13 August 2016
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5973011
10 June 2016
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5905729
21 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5860399
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 January 2026
Resolved
As appropriate for its intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2026
Resolved 12 February 2026
Resolution: Charts brought onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 October 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Remote fuel shut off valves are not marked with directions of operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 4 November 2024
Resolution: Install label with directions for use
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 October 2024
Resolved
A passenger accommodation space must not contain any item that could injure a passenger, unless such an item is adequately shielded or isolated. Starboard window is broken in lower accommodation space.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 4 November 2024
Resolution: Window replaced with new
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 October 2024
Resolved
Provision shall be made by means of plugs, covers. etc., to prevent the admission of air into the space protected. Engine room fire dampeners were found wasted and holed.
46 CFR 181.20-35
(Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2024
Resolved 4 November 2024
Resolution: Dampener replaced with new.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 December 2022
Resolved
There are several penetrations on engine room bulkheads. Cable runs need to be sealed and make watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2022
Resolution: All penetrations were sealed as requested by MI
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2022
Resolved
Engineroom ventilation clousures are broken due to excessive corrosion. Attached ventilation and ensure they seal correctly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2022
Resolution: Vessel attached hinges to hull and added a rubber gasket on the edges of clousure. All sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2022
Resolved
There are 3 fuel leaks on stbd side engine and one fuel leak on mid engine. Clean all piping and retest.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2022
Resolution: Crew replaced all fittings and gaskets on raicor filters. Test sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2022
Resolved
There 3 missing strainers on bilge pick ups. Replace with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2022
Resolution: Crew added new strainers to piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2022
Resolved
All electric bilge pumps were loose. Pumps should be permanently attached to prevent them from moving. Re attached them and test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2022
Resolution: All bilge pumps were attached to the lowest point possible. Test sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 September 2020
Resolved
Piping in vital systems shall comply with the provisions in Subchapter F. In void #1 and #2, approximately 2 feet of bilge piping above the bilge pick up is made of rubber hose vice metal pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 8 September 2020
Resolution: Recieved pictures detailing proper repair of the bilge pick up lines in void #1 and #2.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
Vsl is broadcasting invalid IMO # and Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2018
Resolution: While running a query in VIVS, all information for the vessel had been updated and AIS was broadcasting the proper information.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 September 2017
Resolved
Make temporary repairs to holed bulkhead IWO keel generator space, forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2017
Resolution: Repair was inspected from both sides, bulkhead thru holes were filled with belzona, both side were covered with 3/4 plywood appx. 18' x 10' and epoxied, 2 thru bolts were installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 September 2017
Resolved
Make permanent repair to holed bulkhead IWO keel generator space. Provide permanent repair proposal.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 15 December 2017
Resolution: Bulkhead was cropped and renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 22 September 2017
Resolved
Replace throttle cable conduit in void #1.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 5 October 2017
Resolution: Replaced throttle cable conduit.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 22 September 2017
Resolved
Replace engine belt driving bilge pump on port engine.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 5 October 2017
Resolution: Replaced engine belt driving bilge pump on port engine.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 September 2017
Resolved
Fill holes in aft bulkhead of generator space.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 5 October 2017
Resolution: Filled holes in aft bulkhead of generator space.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2017
Resolved
Repair emergency light fixture adjacent to emergency escape hatch in engine room.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 5 October 2017
Resolution: Repaired emergency light fixture adjacent to emergency escape hatch in engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 September 2017
Resolved
Terminate dead end cable in junction box.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 22 September 2017
Engineering › Lubricating Oil Service System › Inlet
Issued 22 September 2017
Resolved
Repair leak from starboard engine lube oil sensor.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 22 September 2017
Resolution: Starboard engine lube oil sensor was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 September 2017
Resolved
Issued 835 for engine room fire suppresion system to be inspected, tag expired august 2017, not to carry passengers until system inspected and recipt e-mailed to [email withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 1 September 2017
Resolution: RCV e-mailed report servicing system 1500L
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 August 2017
Resolved
Center engine found with oil leak & exhaust leak on stbd exhaust pipe. Repair leak and make exhaust pipe available for inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 14 August 2017
Resolution: Vessel rep. provided verbal repair proposal.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 August 2017
Resolved
Make exhaust piping repairs in engine room on center engine available for inspection once completed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 23 August 2017
Resolution: repairs made replaced expansion joint.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 August 2017
Resolved
Make exhaust piping repairs in space aft of the engine room available for inspection once completed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 23 August 2017
Resolution: weld repairs made tested SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 14 August 2017
Resolved
Repair oil leak found on center engine.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 1 September 2017
Resolution: system altered to capture vapors.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 August 2017
Resolved
Make void aft of the engine room safe for entry and make exhaust pipes available for inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 14 August 2017
Resolution: Vessel rep. provided repair proposal.
Construction/Loadline › Hull › Weld
Issued 10 June 2016
Resolved
Make permanent repairs to leaking weld in steering compartment IWO port rudder post, to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 27 June 2016
Resolution: Completed plate insert to the satisfaction of the attending Marine Inspector.