Records from 1985 to 2017. Most recent: inspection, 16 October 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 76
16 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6288334
29 March 2017
Deficiency Check · MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6110043
26 September 2016
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6009398
30 March 2016
MTSA/ISPS Verification · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5843834
29 September 2015
Drydock Exam · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5749472
5 June 2014
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4880493
24 May 2012
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4321499
28 February 2012
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4257326
24 February 2012
Simplified Stability Test
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4244678
23 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4229652
19 February 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3682216
12 May 2009
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3473897
10 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3261237
12 May 2008
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3204401
6 May 2008
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3199785
5 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2980600
24 May 2007
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2938847
16 May 2007
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2931330
24 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806997
24 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2807000
7 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2792816
26 May 2006
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2659495
22 May 2006
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2659493
27 May 2005
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2369550
24 May 2005
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2365607
20 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363303
9 August 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2160513
7 June 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2091472
2 June 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2086332
28 May 2004
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2080587
25 May 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2077640
24 May 2004
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2075381
21 April 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2049192
6 March 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2019367
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999512
28 May 2003
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1803563
20 May 2003
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1798390
29 May 2002
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1716118
20 May 2002
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1716117
29 May 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1461432
21 May 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387132
22 May 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436385
19 May 2000
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436386
25 May 1999
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1391030
10 May 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378680
27 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1129538
26 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381263
2 June 1997
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1380894
7 June 1996
Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1385736
3 June 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355826
12 June 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1187504
1 June 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355265
25 May 1995
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358769
22 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1023626
15 June 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1401879
14 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1018520
31 May 1994
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354736
20 December 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850249
22 June 1993
COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463772
7 June 1993
Deficiency Check · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451866
2 February 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1132824
28 July 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 949817
28 July 1992
Inclining Experiment
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373740
29 June 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 962923
4 June 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948800
28 June 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 920930
14 June 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1218142
12 September 1990
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 914744
5 September 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 888834
24 October 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1202678
2 September 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039984
4 November 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021411
8 August 1987
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1336341
3 November 1986
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1010483
16 August 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1292602
5 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1290638
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 March 2017
Resolved
log monthly EPIRB test
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: updated EPIRB log
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 March 2017
Resolved
make vent covers to install quickly
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: covers have hook and pile tape to install quickly
Lifesaving › Lifefloat › Paddle
Issued 29 March 2017
Resolved
attached paddles to lifefloat
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: Paddles are attached to lifefloats
Lifesaving › Lifebuoys › Serviceable
Issued 29 March 2017
Resolved
Renew both life rings
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: New USCG approved life rings onboard
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 March 2017
Resolved
Crewmen need to be on company's consortium list
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: Proof of crew enrollment provided
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 March 2017
Resolved
renew light float on life ring
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 13 April 2017
Resolution: New light float installed
Construction/Loadline › Hull › Hull Plating
Issued 26 September 2016
Resolved
sevaral boubles in paint on PT and STBD hull
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 October 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 September 2016
Resolved
trnsverse frame in storage space has wood rot in way of keel bolt
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 October 2016
Communications › Radio Communications › EPIRB
Issued 1 April 2016
Resolved
Register EPIRB with NOAA and place new decal on EPIRB.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 13 April 2016
Resolution: Received valid registration.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 April 2016
Resolved
Provide contract with chemical testing program for current year.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 11 April 2016
Resolution: Received new contract for the current year.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 April 2016
Resolved
Renew expired Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 11 April 2016
Resolution: Received copy of new certificate.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 1 April 2016
Resolved
Remove all flamable products from vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2016
Resolution: Witnessed crew remove all flamables from vessel.
Construction/Loadline › Hull › Hull Plating
Issued 29 September 2015
Resolved
Make repairs to rotted Garboard Strake at frame 2, port and starboard sides.
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Engineering › Bilge Water Management System › Valve
Issued 29 September 2015
Resolved
Replace frozen bilge valve in mid-aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2015
Resolved
Remove dead-ended wires from vessel.
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Communications › Radio Communications › EPIRB
Issued 24 February 2012
Resolved
Prior to carrying passengers, renew battery for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2012
Resolved 20 March 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2012
Resolved
Provide, install and prove proper operation of "Not Under Command" and Restricted in Their Ability to Maneuver navigation lights as per Rule 27 and ANNEX 1 of Navigation Rules, International-Inland (72 COLREGS). Electrical installation shall meet 46 CFR Subchapter "J".
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 14 September 2012
Resolution: Rcvd email with pics of proper operation of lights and light tower.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 24 February 2012
Resolved
Provide and place on board, all day shapes as required to meet Rule 27 of Navigation Rules, International-Inland (72 COLREGS). Demonstrate means to properly display same.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 14 September 2012
Resolution: Rcvd email with pics of all day shapes required.
Personnel › Training › Familiarization Training
Issued 24 February 2012
Resolved
Prior to carrying passengers, conduct crew drill for Fire, Man Overboard and Abandon Ship. Upon completion, log same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2012
Resolved 20 March 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2012
Resolved
Prior to carrying passengers, provide suitable anchor light.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2012
Resolved 20 March 2012
Engineering › Steering Gear System › Rudder Stock
Issued 24 February 2012
Resolved
Prior to carrying passengers, provide tiller or other means to perform emergency steering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2012
Resolved 20 March 2012
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 February 2012
Resolved
Prior to carrying passengers, provide proof of enrollment of all crewmembers in a company random drug testing consortium.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 February 2012
Resolved
Provide valid alcohol testing equipment for crew to satisfy the 2-hour rule for a Serious Marine Incident (SMI).
Action required: 705 - Other - as specified
Due 30 March 2012
Resolved 20 March 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 24 February 2012
Resolved
Prove proper operation of gauges at each operating station that indicate engine revolutions per minute (RPM), jacket water discharge temperature and lubricating oil pressure as per 46 CFR 182.410(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 13 September 2012
Resolution: Obsvd proper operation of gauges at operating station.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 February 2012
Resolved
Prior to carrying passengers, provide a licensed Master that is enrolled in the Company Random Drug Testing Consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2012
Resolved 20 March 2012
Communications › Radio Communications › EPIRB
Issued 12 May 2008
Resolved
PROVIDE AND INSTALL NEW HYDROSTATIC RELEASE UNIT (HRU) FOR EPIRB.
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 17 May 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 May 2008
Resolved
IMPLEMENT A COMPANY DRUG AND ALCOHOL TESTING PROGRAM AS PER 46 CFR 16, 46 CFR 4.06, 49 CFR 40 AND 33 CFR 95.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 10 June 2008
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 May 2007
Resolved
RENEW ALL BATTERIES FOR PFD LIGHTS AND MAKE LOG ENTRY IN OFFICIAL LOG BOOK.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 May 2007
Resolved
RENEW ALL BATTERIES FOR LIFEFLOAT FLOATING ELECTRIC WATERLIGHT AND MAKE LOG ENTRY IN OFFICIAL LOG BOOK.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2007
Resolved
RENEW ALL BATTERIES FOR STARBOARD AFT RING BUOY FLOATING ELECTRIC WATERLIGHT AND MAKE LOG ENTRY IN OFFICIAL LOG BOOK.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 24 May 2007
Resolved
UPDATE SAFETY MANAGEMENT SYSTEM (SMS) TO INCORPORATE COMPANY POLICY IN REGARDS TO THE CHEMICAL TESTING FOLLOWING SERIOUS MARINE INCIDENTS (TWO (2) HOUR RULE).
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Lifesaving › Lifebuoys › Stowage
Issued 24 May 2007
Resolved
HARD SPLICE LIFELINE AND FLOATING ELECTRIC LIGHT LINE FOR STARBOARD AFT RING BUOY.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 May 2007
Resolved
HARD SPLICE EACH LIFEFLOAT PAINTER AND ELECTRIC WATERLIGHT LINE
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 May 2007
Resolved
PROVIDE MEANS ASHORE TO DOCUMENT, PROVIDE AND COMMUNICATE PASSENGER INFORMATION FOR EACH VOYAGE.
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 5 June 2007
Engineering › Fuel Oil Service System › Filter
Issued 16 May 2007
Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS FOR HIRE, PROVIDE AND INSTALL STEEL FLAME SHIELD FOR STARBOARD RACOR FUEL OIL FILER/SEPERATOR.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 24 May 2007
Stability › Unintentional Flooding › General
Issued 16 May 2007
Resolved
PRIOR TO RE-FLOATING, DISASSEMBLE, CLEAN, INSPECT AND REPAIR, AS NECESSARY, STARBOARD SEA WATER STRAINER.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 17 May 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 May 2007
Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS FOR HIRE, SEAL ALL OPENINGS FOUND IN AFT ENGINEROOM BULKHEAD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 24 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2006
Resolved
GRIND OUT CHINE PLANK ROTTED AREAS FWD PORTSIDE FOR FURTHER INSPECTION
Due 22 May 2006
Resolved 22 May 2006
Resolution: PLANK TO BE RENEWED DUE TO RESULTS OF DETAILED INSPECTION.
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2006
Resolved
REMOVE ROTTED WOOD ALONG CHINE PLANK AFT PORTSIDE FOR FURTHER INSPECTION.
Due 22 May 2006
Resolved 22 May 2006
Resolution: AREAS TO BE REPAIRED WITH OVERSIZE BUNGS AND FASTENER RENEWAL.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 May 2006
Resolved
BRACKET AND SUPPORT PORT AND STBD WATERLIFTS/MUFFLERS FOR MAIN ENGINES.
Due 22 May 2006
Resolved 24 May 2006
Communications › Radio Communications › EPIRB
Issued 28 May 2004
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, RENEW EPIRB ANTENNEA.
Due 28 May 2004
Resolved 28 May 2004
Engineering › Steering Gear System
Issued 24 May 2004
Resolved
Renew port upper rudder bearing. LEGACY COMPONENT DESC: Rudder Bearing
Due 28 May 2004
Resolved 28 May 2004
Engineering › Bilge Water Management System
Issued 24 May 2004
Resolved
Renew Cargo Hold bilge pump discharge hose in its entirety, starboard side. LEGACY COMPONENT DESC: Hose
Due 28 May 2004
Resolved 28 May 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 May 2004
Resolved
Make permanent repairs to leaking main engine exhaust pipe flanges located in port forward and aft ends of Cargo Hold. LEGACY COMPONENT DESC: Piping (exhaust)
Due 28 May 2004
Resolved 28 May 2004
Stability › Watertight Integrity
Issued 24 May 2004
Resolved
Renew port, aft overboard flexible hose steel clamp found broken and leaking.
Due 28 May 2004
Resolved 28 May 2004
Construction/Loadline › Structures
Issued 24 May 2004
Resolved
Make permanent repairs to and renew hardware in way of port rudder hull frame attachment, as shown.
Due 28 May 2004
Resolved 28 May 2004
Electrical › Electrical Distribution System (service)
Issued 24 May 2004
Resolved
Remove dead-ended electrical wiring found on starboard side of lazarette. LEGACY COMPONENT DESC: Wiring
Due 28 May 2004
Resolved 28 May 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 May 2004
Resolved
Renew all wrappings located on starboard main engine exhaust piping in Cargo Hold. LEGACY COMPONENT DESC: Piping (exhaust)
Due 28 May 2004
Resolved 28 May 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 May 2004
Resolved
Make permanent repairs to leaking main engine exhaust piping in starboard side of Cargo Hold. LEGACY COMPONENT DESC: Piping (exhaust)
Due 28 May 2004
Resolved 28 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 May 2004
Resolved
Make permanent repairs to starboard, forward deck rail mounting, as shown. LEGACY COMPONENT DESC: Deck Rail
Due 28 May 2004
Resolved 28 May 2004
Documentation › Logs/Records › Drug Test Records
Issued 28 May 2003
Resolved
PROVIDE PROOF THAT CREWMAN IS 46 CFR 16 COMPLIANT
Due 28 May 2003
Resolved 28 May 2003
Navigation › Piloting/Steering › Marine Charts
Issued 28 May 2003
Resolved
PROVIDE UPDATED CHARTS FOR OPERATING AREA
Due 28 May 2003
Resolved 28 May 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 May 2003
Resolved
MAKE COMPASS LIGHT OPERATIONAL. VESSEL RESTRICTED TO DAYTIME OPERATIONS UNTIL CORRECTED
Due 28 May 2003
Resolved 28 May 2003
Lifesaving › Lifebuoys
Issued 28 May 2003
Resolved
RENEW LIFERING LINE, PAINTER, AND WATERLIGHT LINE
Due 28 May 2003
Resolved 28 May 2003
Construction/Loadline › Hull
Issued 20 May 2003
Resolved
RENEW 3 KNEES IN ENGINE ROOM STBD SIDE AS DESIGNATED BY CG INSPECTOR
Due 23 May 2003
Resolved 28 May 2003
Lifesaving
Issued 29 May 2001
Resolved
INSTALL ADEQUATE LIFESAVING CAPACITY FOR 26 PERSONS. UNTIL CORRECTED, VESSEL RESTRICTED TO 18 PERSONS FOR INTERNATIONAL TRAVEL.
Condition: Unknown
Due 29 May 2001
Resolved 5 September 2001
Engineering
Issued 29 May 2001
Resolved
REPAIR PORT PROPULSION SHAFT NO LATER THAN 29JUN01.
Condition: Unknown
Due 29 June 2001
Resolved 5 September 2001
Lifesaving
Issued 29 May 2001
Resolved
RENEW EPIRB ANTENNEA PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 May 2001
Resolved 5 September 2001
Lifesaving
Issued 29 May 2001
Resolved
RENEW RETRO REFLECTIVE TAPE ON 24 LIFEJACKETS IDENTIFIED BY CG INSPECTOR.
Condition: Unknown
Due 29 May 2001
Resolved 5 September 2001
Lifesaving
Issued 29 May 2001
Resolved
RENEW HYDROSTATIC EPIRB HYDROSTATIC RELEASE NO LATER THAN 29JUN01.
Condition: Unknown
Due 29 June 2001
Resolved 5 September 2001
Documentation
Issued 2 June 1997
Resolved
PROVIDE COPY OF SAFETY RADIO CERTIFICATE
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Navigation
Issued 2 June 1997
Resolved
PROVIDE ANCHOR LIGHT.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 7 June 1996
Resolved
RENEW RETRO-REFLECTIVE TAPE ON ADULT LIFE PRESERVERS AS NEEDED.
Condition: Unknown
Due 15 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 3 June 1996
Resolved
Remove ceiling in transom and repair/replace framing in way of natural air vents. Make this area available for inspection by the Coast Guard.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 3 June 1996
Resolved
Repair/replace bulkhead between engine room and lazarette in way of port overhead due to wasted wood. Make available for Coast Guard inspection.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 3 June 1996
Resolved
Properly cap MSD intake. Remove cork and 5200/bondo. Use a metallic plug or cap that is threaded to the intake penetration.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 3 June 1996
Resolved
Repair/replace steering pillar block on the starboard side due to wastage.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 1 June 1995
Resolved
REPLACE BOW LIGHT BULB._x001C_
Condition: Unknown
Due 3 June 1995
Resolved 3 June 1995
Lifesaving
Issued 1 June 1995
Resolved
REPLACE RETROREFLECTIVE TAPE ON LIFEJACKETS AS REQUIRED._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 1 June 1995
Resolved
REPLACE GRABLINES ON BOTH RINGBUOYS._x001C_
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 15 June 1994
Resolved
REPLACE DETERIORATED AND MISSING REFLECTIVE TAPE ON ALL LIFE PRESERVERS AS NECESSARY.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 15 June 1994
Resolved
INSTALL REFLECTIVE TAPE ON ALL RING BOUYS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Documentation
Issued 31 May 1994
Resolved
PROVIDE DESCRIPTION OF COMPANY'S DRUG TESTING PROGRAM.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Lifesaving
Issued 22 June 1993
Resolved
REPLACE 60 FT. LINES ON FORWARD RING BUOY.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993
Resolved
REPLACE GRAB LINES ON TWO AFT RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 7 June 1993
Resolved
SHAFT COOLING HOSES NEED TO BE DOUBLE CLAMPED.
Condition: Unknown
Due 29 June 1993
Resolved 23 June 1993
Construction/Loadline
Issued 7 June 1993
Resolved
ENGINE ROOM BILGES NEED CLEANING, OWNER TO CLEAN UP EXCESS WATER AND OIL. _x001C_
Condition: Unknown
Due 29 June 1993
Resolved 23 June 1993
Electrical
Issued 7 June 1993
Resolved
110 VOLT OUTLETS IN DIVE LOCKER ARE BADLY DETERIORATED, OWNER TO REPAIR OR REMOVE OUTLETS AND ALL ASSOCIATED WIRING.
Condition: Unknown
Due 29 June 1993
Resolved 23 June 1993
Engineering
Issued 7 June 1993
Resolved
FUEL FILTER ON PORT MDE HAS NO PROTECTIVE COVER, OWNER TO REPLACE GLASS GLOBE OR PROVIDE PROPER STEEL BOWL.
Condition: Unknown
Due 29 June 1993
Resolved 23 June 1993
Unknown
Issued 29 June 1992
Resolved
PRESENT THE PRESSURE VESSELS ASSOCIATED WITH THE SCUBA TANK FILLING CASCADESYSTEM FOR INSPECTION.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Construction/Loadline
Issued 29 June 1992
Resolved
PROVIDE POSITIVE CLOSING VALVES FOR ALL THROUGH HULL FITTINGS WHICH _x001C_ PENETRATE THE HULL AND ARE LESS THAN 6 INCHES FROM THE WATER LINE.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Fire Fighting
Issued 29 June 1992
Resolved
PROVIDE PROOF THAT ALL FIRE EXTINGUISHERS HAVE BEEN SERVICED WITHIN THE_x001C_ PAST YEAR PRIOR TO TAKING ANY PASSENGERS FOR HIRE.
Condition: Unknown
Due 30 June 1992
Resolved 10 July 1992
Electrical
Issued 29 June 1992
Resolved
LEAD/OR FIBERGLASS LINE THE BATTERY BOX FOR THE BATTERY SERVING THE_x001C_ VHF RADIO ON THE VESSEL'S FLYING BRIDGE.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Documentation
Issued 29 June 1992
Resolved
COORDINATE SIMPLIFIED STABILITY TEST W/MSD ST. THOMAS INSPECTORS. THE_x001C_ VESSEL IS NOT TO ENGAGE IN AN INTERNATIONAL VOYAGE W/ MORE THAN 12 _x001C_ PAX UNTIL THE VESSEL RECEIVES A STABILITY LTR.
Condition: Unknown
Due 30 August 1992
Resolved 4 June 1993
Lifesaving
Issued 29 June 1992
Resolved
REPLACE MISSING AND DETERIORATED REFLECTIVE TAPE ON PFDS
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 29 June 1992
Resolved
PROVIDE A VALVE ON THE BILGE PIPE WHERE IT PENETRATES THE COLLISION BULKHEAD EITHER IN THE FORWARD BERTHING SPACE OR WITHIN THE FOREPEAK. IF LOCATED IN THE FOREPEAK THE VALVE MUST CAN BE REMOTELY ACTUATED FROM THE MAIN DECK.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Fire Fighting
Issued 29 June 1992
Resolved
INSTALL A MANUAL OVERRIDE, ACCESSIBLE FROM THE HELM, ON THE VESSEL'S FIXED CARBON DIOXIDE FIRE FIGHTING SYSTEM FOR THE ENGINE ROOM. _x001C_
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 12 September 1990
Resolved
PROVIDE 12 ROCKET FLARES FOR INTERNATIONAL ROUTE.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Fire Fighting
Issued 12 September 1990
Resolved
INSTALL APPROPRIATE VENT CLOSURE DEVICES ON ALL ENGINE ROOM VENTS TO ENSUREPROPER OPERATION OF THE FIXED CO2 FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 5 August 1985
Resolved
CONDUCT REQUIRED OPERATIONAL TESTS DURING THE SCHEDULED UNDERWAY EXAM.
Condition: Unknown
Due 5 August 1985
Resolved 5 August 1985