Records from 1986 to 1998. Most recent: inspection, 17 August 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
17 August 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1131823
10 June 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 792713
13 February 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112647
24 September 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115867
22 August 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1409557
7 May 1996
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388020
22 August 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390108
1 September 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460732
3 May 1994
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382762
23 August 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 846361
23 August 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1391889
23 September 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 935274
27 August 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 959961
6 May 1992
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961517
8 January 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958441
8 January 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958443
12 December 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257585
12 November 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257017
10 October 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1248937
27 August 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1251736
16 October 1990
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907654
27 August 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1240215
3 May 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 924018
3 January 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1217699
29 August 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1044611
13 March 1989
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 898058
25 October 1988
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 889958
28 September 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1194385
2 November 1987
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1023552
27 August 1987
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1339273
30 April 1986
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1296831
26 February 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 988300
Lifesaving
Issued 24 September 1997
Resolved
PROVIDE A COMPLETE MARINE FIRST AID KIT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Documentation
Issued 24 September 1997
Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG TESTING PROGRAM. INCLUDE MIS REPORT,EAP TRAINING, DISPLAY OF LITERATURE.
Condition: Unknown
Due 24 October 1997
Resolved 30 October 1997
Electrical
Issued 24 September 1997
Resolved
PROVIDE ONE PORTABLE FLASHLIGHT FOR ENGINE COMPARTMENT-EMERGENCY LIGHTING.
Condition: Unknown
Due 24 October 1997
Resolved 30 October 1997
Construction/Loadline
Issued 24 September 1997
Resolved
STENCIL OUTSIDE OF EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 24 October 1997
Resolved 30 October 1997
Lifesaving
Issued 24 September 1997
Resolved
POST PFD DONNING INSTRUCTION PLACARD FOR ADULT AND CHILD JACKETS.
Condition: Unknown
Due 24 October 1997
Resolved 30 October 1997
Navigation
Issued 24 September 1997
Resolved
INSTALL STERNLIGHT. THE VESSEL IS RESTRICTED TO NO OPERATIONS IN REDUCED VISIBILITY AND BETWEEN SUNSET AND SUNRISE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Electrical
Issued 24 September 1997
Resolved
REMOVE DEADENDED CABLE IN BATTERY COMPARTMENT AND INSTALL CIRCUIT PROTECTION (FUSES) ON UNPROTECTED CIRCUITS.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 24 September 1997
Resolved
ATTACH A 3' TO 6' LANYARD TO RING BUOY LIGHT WHICH ATTACHES TO A RING BUOY WITH DETACHABLE CLIP.
Condition: Unknown
Due 24 October 1997
Resolved 30 October 1997
Engineering
Issued 22 August 1996
Resolved
Identify location of exhaust leak in lazarette and make repairs.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Accommodation/Occupational Safety
Issued 22 August 1996
Resolved
Mark overboard discharge valve for MSD with placard prohibiting discharge of sewage within 3 nm of land.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Electrical
Issued 22 August 1996
Resolved
Remove deadend wires in lazarette.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Lifesaving
Issued 22 August 1996
Resolved
Replace line on Buoyant Appartatus.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Construction/Loadline
Issued 22 August 1996
Resolved
Repair as original deck above the lazarrette.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Documentation
Issued 22 August 1996
Resolved
Prove enrollment of deck hand in drug testing program.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Lifesaving
Issued 22 August 1996
Resolved
Install EPIRB in a location free of rigging.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Lifesaving
Issued 22 August 1996
Resolved
Replace line on ringbuoy.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Navigation
Issued 1 September 1994
Resolved
REPLACE OR REPAIR 360 DEGREE MAST LIGHT PRIOR TO OPERATING AT NIGHT OR IN INCLIMATE WEATHER.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Navigation
Issued 1 September 1994
Resolved
PROVIDE ON BOARD A CURRENT, APPROVED LIGHT LIST FOR APPLICIBLE OPERATING AREA.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Fire Fighting
Issued 27 August 1992
Resolved
PROVIDE ONE (1) USCG APPROVED TYPE B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Construction/Loadline
Issued 27 August 1992
Resolved
PROVIDE INDICATING LIGHT IN PILOT HOUSE FOR AUTO BILGE PUMP.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Lifesaving
Issued 27 August 1992
Resolved
PROVIDE FIVE (5) ADULT TYPE I PFD'S AND ONE (1) CHILD PFD - VSL RESTRICTED_x001C_TO 9 TOTAL P.O.B. UNTIL DEFICIENCY CORRECTED.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Navigation
Issued 27 August 1992
Resolved
PROVIDE TILLER FOR EMERGENCY STEERING.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Deck/Cargo
Issued 27 August 1992
Resolved
INSTALL GASKET AROUND ENG ROOM HATCH COMBING - CONDUCT HOSE TEST TO PROVE WEATHERTIGHT.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Accommodation/Occupational Safety
Issued 27 August 1991
Resolved
CLOSE OVERBOARD VALVE FROM HOLDING TANK WHEN IN TERRITORIAL WATERS AND INSIDE THE BASELINE FROM WHICH THE TERRITORIAL SEA IS MEASURED, ALSO PROVIDE POLLUTION PLACARD._x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Engineering
Issued 27 August 1991
Resolved
REPLACE PETCOCK IN FUEL OIL FILTER WITH PLUG AND/ OR PLUG PETCOCK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Engineering
Issued 27 August 1991
Resolved
PROVE ACCEPTABILITY OF FUEL SUPPLY LINE HOSE OR REPLACE WITH ACCEPTABLE FLEXIBLE HOSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Engineering
Issued 27 August 1991
Resolved
MOVE FUEL TANK VENT THROUGH-HULL FITTINGS AS HIGH AS POSSIBLE ABOVE WATERLINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Documentation
Issued 27 August 1991
Resolved
CONDUCT SIMPLIFIED STABILITY TEST FOR EXPOSED WATERS OR PROVE SISTER VESSELSTATUS WITH A VESSEL ALREADY APPROVED FOR EXPOSED WATERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Fire Fighting
Issued 27 August 1991
Resolved
MARK LOCATION OF B-II DRY CHEMICAL FIRE EXTINGUISHER ON CABINET FRONT IN WHICH IT IS INSTALLED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Engineering
Issued 27 August 1990
Resolved
PROVIDE FLAME IMPINGEMENT BOWL FOR RACOR FUEL FILTER.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Lifesaving
Issued 27 August 1990
Resolved
PROVIDE 60' HEAVING LINE FOR RING BUOY.
Condition: Unknown
Due 27 August 1990
Resolved 27 August 1990
Electrical
Issued 28 September 1988
Resolved
WHERE SPRING CLIPS ARE BEING USED, PROVIDE PERMANENT CONNECTIONS ON BATTERY TERMINALS FOR BILGE PUMP WIRING. IN ACCORDANCE WITH 46 CFR 183.05-20 (C), AND PROVIDE IN-LINE FUSES.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Fire Fighting
Issued 28 September 1988
Resolved
PROVIDE TWO NEW B-II FIRE EXTINGUISHERS OR HAVE HYDROSTATIC TEST CONDUCTED ON THOSE PRESENTLY IN USE.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
PROVIDE SECURING DEVICE FOR ENGINE ROOM HATCH, IN ACCORDANCE WITH 46 CFR 171.124 (B)(1).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
PROVIDE MEANS TO ATTACH ALL HATCHCOVERS TO THE HATCH FRAME,COAMING,ECT, TO PREVENT THEIR LOSS AS PER 171.124 (B)(2).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Fire Fighting
Issued 27 August 1987
Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER FOR THE GALLEY.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987
Resolved
PROPERLY LINE BATTERY BOXES WITH SUITABLE MATERIAL TO CONFORM TO 46 CFR 183.05-20(D).
Condition: Unknown
Due 27 August 1987