← All vessels
PRIVATEER
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named PRIVATEER
PRIVATEER is a 1972 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in July 2026, along with 188 deficiencies and 3 casualty investigations between 2002 and 2026.
Records from 1985 to 2026. Most recent: inspection, 4 July 2026.
- Built
- 1972
- Last inspected
- 4 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 188 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2002–2026
Identity
539573
WDK5808
47180
Flag
UNITED STATES
368068510
Maury page id
psix-47180
Inspections, by type
…with no type recorded10
Years with a record
38 calendar years (1985–2026)
The 82 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)83.8 ft × 22.0 ft × 6.6 ft
Registered tonnagegross 77 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEW BERN SHIPYARDS INC · NEW BERN, NC, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 18 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK5808MMSI 368068510 · active · compulsorily equipped · granted 5 December 2018, expires 5 December 2028
WDF8361MMSI 367494050 · expired · compulsorily equipped · granted 9 June 2011, cancelled 14 August 2021
WDF4592MMSI 367453620 · expired · compulsorily equipped · granted 22 May 2010, cancelled 25 July 2020
WYZ7447MMSI not assigned · expired · compulsorily equipped · granted 19 February 1998, cancelled 9 August 2008
WCR4199MMSI not assigned · expired · voluntarily equipped · granted 8 May 1995, cancelled 9 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 82
4 July 2026
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8431753
21 October 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8256541
13 October 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8259484
30 September 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8225506
13 November 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034535
7 October 2024
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8151108
25 July 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967026
5 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7874569
6 November 2023
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7821070
31 May 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701719
9 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648653
6 April 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7425288
6 December 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363492
17 May 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7203011
10 November 2020
Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7093314
7 April 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923888
28 September 2018
Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6550817
10 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6537114
5 September 2018
Hull Examination · Annual Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6531303
7 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6407938
5 April 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118245
30 December 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064029
15 September 2016
Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6001433
10 February 2016
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813112
24 November 2015
Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5769931
26 August 2014
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4967311
26 August 2014
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4987666
7 May 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4304909
14 May 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3475135
9 October 2008
Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3341264
7 May 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3201538
4 January 2007
COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2850149
9 June 2006
Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2674802
11 May 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2354825
17 May 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2069981
28 April 2003
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1781824
17 March 2003
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1758420
10 December 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1717619
10 December 2002
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1723436
28 October 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1696963
2 October 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1683402
16 April 2002
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1605258
30 June 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 7859
16 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1470017
17 April 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361426
15 April 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 790452
27 October 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 805109
28 May 1998
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791736
16 April 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 789838
6 November 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1108408
6 May 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1096113
21 April 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105847
27 March 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1094620
29 May 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1181020
17 April 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1080302
7 June 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 223041
4 May 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1032895
19 April 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 864103
14 March 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1143104
19 April 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 857974
12 April 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166969
19 April 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1132945
31 March 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 833377
21 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952466
24 April 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 949058
21 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 949056
10 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1243461
2 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 931582
25 April 1990
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 919701
4 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1212477
25 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 892056
30 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1201850
24 January 1989
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 892554
25 March 1988
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 991037
30 July 1987
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1333234
24 April 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1012752
6 April 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1309759
9 October 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007712
21 May 1986
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023247
22 April 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1000157
22 April 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 987696
8 April 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 981116
Deficiency record · 188
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 September 2025
Resolved
Fire pump pressure gauge is nonfunctional. Replace gauge to properly show 60 psi operating pressure. 46 CFR 181.10-1 (c)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 September 2025
Resolved
Vessel did not have charts available. Make charts available. 46 CFR 184.420 (a)(1)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025
Resolved
Electrical equipment must be installed to protect from electrical hazards. Vessels shore side electrical connection was missing cover and the electrical box is extremely corroded. Replace electrical connection cover and box.46 CFR 183.200
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2025
Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Several life float paddles were damaged and not labeled with the vessel name. Replace damaged paddles and label accordingly. 46 CFR 180.175
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025
Resolved
Both port and stbd reduction gear shifting cables were found improperly attached with a wooden brackets. Provide each reduction gear shifting cable with
permanent metal supports. 46 CFR 182.220
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025
Resolved
Both drip less shaft seals were found with non-approved water hose attached from the main engine. Replace both hoses with approved water hose. 46 CFR 182.720
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2025
Resolved
The fire extinguisher installed in the engine room was found to be a 2-A. Provide the engine room with a 40-B:C. 46 CFR181.500
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025
Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring in FWD Hold, portside had exposed dead end wire. Properly remove or cover to prevent potential shock or fire hazards and update date wiring diagram. 46 CFR 183.200.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025
Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical outlet in FWD Hold, portside was missing cover. Properly cover outlet socket. 46 CFR 183.200
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Two overhead lights are being powered by an extension cord. Remove extension cord and install permanently electrical outlet to power the lights and update date wiring diagram. 46 CFR 183. 200(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025
Resolved
Vessel is in the process of installing new electrical generators. Provide electrical plans for vessel’s power distribution. 46 CFR 177.202.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 September 2025
Resolved
The sewage tank overboard discharge piping was found with epoxy on the welds. The overboard piping was found with ratchet straps used as support. Provide piping with permanent piping support brackets and make weld repairs to failed area on sewage tank piping. Repair at next drydock.
46 CFR 184.704
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. In the FWD holed MI found old, used transducer in the portside bilge. At next dry-dock remove old transducer to prevent possible flooding hazards. 46 CFR 176.830
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2024
Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings.
Fuel lines to both generators were attached to fitting with hose clamps.
Replace with factory assembled hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2024
Resolved
Engine room flooded with approximately 6 feet of water while at the dock due to a failed hose. repair or replace affected equipment and conduct operation test in the presence of marine inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 March 2024
Resolved
EPIRB battery is expired. Replace the battery on the EPIRB. Vessel is restricted to no more than 3NM from shore until rectified. Cite: 46 CFR 180.64
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024
Resolved
Vessel did not have alcohol test swabs on board. Vessel is restricted to voyages that will prevent crew from getting to alcohol testing ashore within two (02) hours of an incident until rectified. Cite: 46 CFR 185.212
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2024
Resolved
Both generator fuel return fuel filters are installed without flame impingement bowls. Install manufacturer approved flame impingement bowls for all non-metallic fuel filters that do not currently have them equipped. Cite: 46 CFR 182.455(b)(6)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024
Resolved
Two (02) power-taps were located under the main console in the pilothouse. Remove the identified power-taps in the pilot house. Cite: 46 CFR 183.200(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024
Resolved
Main engine room distribution panel had an open/bare breaker opening. Install a blank cover or fuse for the opening on the affected distribution panel. Cite: 46 CFR 183.330
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024
Resolved
“Wire nuts” were utilized for wire terminations in the utility closet on the portside of the main deck. Either place these connections in junction boxes or replace the “wire nuts” with pressure type connectors. Cite: 46 CFR 183.340(i)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2024
Resolved
Ring buoys were found to have insufficient retro reflective tape. Replace the retro tape on affected ring buoys. Cite: 46 CFR 180.70
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2024
Resolved
Various items were missing from the first aid kit. Replace missing items in first aid kit. Cite: 46 CFR 184.710
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 March 2024
Resolved
Vessels charts and nav pubs are out of date. Provide up to date charts and nav pubs. Cite: 46 CFR 184.420
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 November 2023
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Found several watertight bulkheads with wire runs penetrating the bulkhead. Make all watertight bulkheads watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 March 2023
Resolved
All exposed hazards, such as gears or rotating machinery, must be properly protected by a cover, guard or rail. Must install guard over the port main engine rotating belt head.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2023
Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least one (01) inch numbers and letters at the entranceway to that deck.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022
Resolved
FLOATING WATERLIGHT FOR PORT INBOARD LIFEFLOAT ARRANGEMENT WAS INOP DURING INSPECTION. CREW REPLACED BATTERY BEFORE CONCLUSION OF INSPECTION.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 11 December 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Steering gear void space; Bilge suction strainer coroded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2020
Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. Cap fuel piping from unused fuel tank in steering gear void (or make/mark fuel shut off reach rod operable).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2020
Resolved
Each hose must be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies. Replace STBD side main deck fire hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2020
Resolved
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required. Replace Main deck Portable Fire extinguisher found rusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020
Resolved
Remove extension cord from forward void leading to refer box. Secure wiring at 24 inch intervals. Due 07July2020.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 April 2020
Resolved
Install guards around compressor wheels/belt in forward tank void. Due 07July2020.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2020
Resolved
Install flame impingement bowl on generator fuel filter. Due 07July2020.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 April 2020
Resolved
Service fuel shutoff valves. Due 07July2020.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020
Resolved
Mount battery behind generator to prevent falling. Due 07July2020.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020
Resolved
Crop out burnt cable in tank room void. Secure wiring at 24 inch intervals. Due 07July2020.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2020
Resolved
Replace floating water light batteries on ring buoy and life float. Due 07July2020.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 September 2018
Resolved
C/R wasted void vents/fills on main deck X 4.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 September 2018
Resolved
Prove proper operation of fire pump with 2 hoses at 50 psi.
Fire Fighting › Fire Pumps › Arrangement
Issued 7 May 2018
Resolved
Provide controls for fire pump operation at the operating station.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2018
Resolved
Demonstrate proper operation of the mast headlight
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 May 2018
Resolved
Make proper repairs to leaking MSD pipe.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 May 2018
Resolved
Provide plans for approval for the new exhaust installations.
Construction/Loadline › Structures › Superstructure
Issued 7 May 2018
Resolved
Remove jagged hand rails on the outside of the bridge cat walk.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 7 May 2018
Resolved
Maintain MSD overboard valve closed within 3NM of land. Valve was found in the open position inport at the dock at Seafourth Landing Mission Bay San Diego. This was corrected on the spot by the diection of the attending MI
Construction/Loadline › Structures › Superstructure
Issued 7 May 2018
Resolved
Provide a handle for the water tight hatch to the MSD space
Lifesaving › Hand Flares › Expired
Issued 5 April 2017
Resolved
Provide non-expired distress signals.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 April 2017
Resolved
Replace cover for generator battery.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 April 2017
Resolved
Make lifebuoy light operational.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 April 2017
Resolved
Provide master with Marine Radio Operator Permit.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2017
Resolved
EPIRB drills have not been logged.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 April 2017
Resolved
Fix railing in navigational area.
Documentation › Markings/Placards › Warning Signs
Issued 5 April 2017
Resolved
Emergency broadcast placard is missing.
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 April 2017
Resolved
Replace all retro reflective tape on lifefloats.
Lifesaving › Lifefloat › Float-free Link
Issued 5 April 2017
Resolved
Provide float-free link with proper tags.
Lifesaving › Lifefloat › Serviceable
Issued 5 April 2017
Resolved
Replace or service 02 lifefloats.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 April 2017
Resolved
Label forward lifejacket storage compartment.
Lifesaving › Lifefloat › Markings
Issued 5 April 2017
Resolved
Stencil name onto liferafts.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 5 April 2017
Resolved
Survival craft needs to be ready for immediate use. Install ladder to access lifefloats.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017
Resolved
Make bilge alarm in the forward galley operational.
Operations/Management › Drills/Instruction › Fire
Issued 5 April 2017
Resolved
Crew requires fire fighting training for equipment operations and protocol.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 5 April 2017
Resolved
Provide fire pump with 50 GPM pressure.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 September 2016
Resolved
Add courses no greater than 4 inches between each around the wheelhouse.
Documentation › Certificates/Documents › Stability Letter
Issued 11 February 2016
Resolved
Post stability letter at the operating station
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2016
Resolved
1. The vessel is severely overdue for required annual inspection. Conduct annual inspection
prior to carrying passengers for hire
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 February 2016
Resolved
Properly mark all life jacket stowage lockers
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2016
Resolved
Provide guards on all rotating machinery in the engine room;main shafts, bilge pumps.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2016
Resolved
Provide di=electric matting for generator electrical disrubution panel.
Lifesaving › Lifebuoys › Serviceable
Issued 10 February 2016
Resolved
renew upper life ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 February 2016
Resolved
Renew all batteries for water lights on life ring buoys and life floats
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 February 2016
Resolved
Provide current FCC radio telephony safety certificate
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 10 February 2016
Resolved
Provide radio operators permit.
Stability › Incline Test › General
Issued 24 November 2015
Resolved
Submit a detailed list of items to be added, or removed, including weight estimates and calculation tot eh Marine safety center in accordance with NTN-04-95
Engineering › Bilge Water Management System › Piping
Issued 24 November 2015
Resolved
Install proper piping for STBD main engine bilge pump (suction and discharge)
Engineering › Bilge Water Management System › Not Operational
Issued 26 August 2014
Resolved
REMOVE EXCESSIVE OILY WATER FROM BILGES.
Engineering › Bilge Water Management System › Not Operational
Issued 26 August 2014
Resolved
PROVE PROPER OPERATION OF HIGH LEVEL BILGE ALARM.
Communications › Radio Communications › EPIRB
Issued 14 May 2009
Resolved
Renew epirb battery
Documentation › Logs/Records › Logbook (official)
Issued 14 May 2009
Resolved
Provide vessel log book
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 May 2009
Resolved
Label all bilge alarms on bridge console
Personnel › Training › Rules of the Road
Issued 14 May 2009
Resolved
Provide copy of rules of the road book
Operations/Management › Drills/Instruction › Safety Orientation
Issued 14 May 2009
Resolved
Label emergency fuel shut offs
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 May 2009
Resolved
Renew worn lifeline
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 May 2009
Resolved
Renew retro tape on ring buoy
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2009
Resolved
secure or remove wire nuts on circ pump stbd side engineroom
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 October 2008
Resolved
Renew wasted deck plating in galley hold.
Construction/Loadline › Structures › Scuttle
Issued 9 October 2008
Resolved
Repair or renew to make water tight, all interior scuttles and hatches on main deck.
Lifesaving › Hand Flares › Quantity
Issued 7 May 2008
Resolved
Replace one orange smoke flare
Fire Fighting › Fire Hoses › Connections
Issued 7 May 2008
Resolved
Replace missing spanner fwd stbd fire station
Engineering › Bilge Water Management System › Piping
Issued 7 May 2008
Resolved
Replace PVC bilge piping in tank room w/ proper metallic piping
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 7 May 2008
Resolved
Provide lock for MSD overboard valve
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2008
Resolved
Replace lifering body line & nylon keeper on lifering aft of pilot house
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2008
Resolved
Repair upper mast red nav light
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 May 2008
Resolved
Replace 5 unservicable lifejackets
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 May 2008
Resolved
Repair/replace all lagging on exhaust piping
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 May 2008
Resolved
Repair exhaust leaks in engine room
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 May 2008
Resolved
Crop & renew wasted muffler thru bulkhead pipe
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 7 May 2008
Resolved
Install guard on generator
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2008
Resolved
Properly wire all accessory wires off generator batteries.
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 May 2008
Resolved
Properly label 12volt panel
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 May 2008
Resolved
Install cover on 110 volt panel
Engineering › Freshwater Generation System › Piping
Issued 7 May 2008
Resolved
Properly mount potable water pressure tank
Engineering › Bilge Water Management System › Piping
Issued 7 May 2008
Resolved
Crop and renew stbd, fwd wasted bilge overboard pipe
Electrical › Electric Generation Source (service) › Generator
Issued 7 May 2008
Resolved
Properly mount generator altenator
Engineering › Bilge Water Management System › Interface Detector
Issued 7 May 2008
Resolved
Repair wiring on all bilge high level alarms and properly mount switches
Lifesaving › Hand Flares › Expired
Issued 4 January 2007
Resolved
Provide 2 red flares
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 January 2007
Resolved
Provide 2 ring buoy lights
Lifesaving › Lifefloat › Capacity
Issued 4 January 2007
Resolved
Provide two lifefloats with a total capacity of 44 POB
Communications › Radio Communications › EPIRB
Issued 4 January 2007
Resolved
Provide new hydrostatic release for epirb.
Engineering › Bilge Water Management System › Not Operational
Issued 4 January 2007
Resolved
Exercise bilge manifold system in all compartments.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 January 2007
Resolved
provide bilge alarm at opoerating station.
Engineering › Fuel Oil Service System › Valve
Issued 9 June 2006
Resolved
Label the emergency fuel shut offs.
Lifesaving › Lifefloat › Paddle
Issued 8 May 2006
Resolved
Replace all of the lifefloat paddles.
Lifesaving › Lifefloat › Lifeline
Issued 8 May 2006
Resolved
Replace as needed, the life lines on the lifefloats.
Lifesaving › Lifefloat › Serviceable
Issued 8 May 2006
Resolved
Repair any and all holes and fractures in the lifefloats with manufacture approved repair kits.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 May 2006
Resolved
Provide and install lifejacket doning placards.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 May 2006
Resolved
Repair excessive leaking on the port shaft packing.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 May 2005
Resolved
Prior to carrying passengers, conduct fire & man overboard drills in the presence of a Marine Inspector.
Operations/Management › Drills/Instruction › Fire
Issued 11 May 2005
Resolved
Provide a log or other record of crew drills and training when completed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 May 2005
Resolved
Prove proper operation of bilge high water alarm in tank room.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 May 2005
Resolved
Provide approved boat cable to power 12-volt potable water pump in galley hold. Remove all associated dead-ended cable & wiring IWO same.
Engineering › Bilge Water Management System › Piping
Issued 17 May 2004
Resolved
Prior to carrying passengers, prove proper operation of fixed bilge pumping capability.
Engineering › Fuel Oil Service System › Piping
Issued 17 May 2004
Resolved
Prior to carrying passengers, repair fuel and/or lube oil leaks on generator.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2004
Resolved
Provide and prove proper operation of a second fixed bilge pump. Until completed vessel may continue to operate with the existing sump pump and hose available on board at all times. LEGACY COMPONENT DESC: Pump
Communications › Radio Communications
Issued 17 May 2004
Resolved
Provide an emergency broadcast placard.
Engineering › Bilge Water Management System
Issued 28 April 2003
Resolved
Prove proper operation of combination bilge/fire pump. LEGACY COMPONENT DESC: Pump
Operations/Management › Drills/Instruction
Issued 28 April 2003
Resolved
Conduct fire and man overboard drills with new crew members, and properly enter them in the vessel's training/drill log. LEGACY COMPONENT DESC: Fire
Engineering › Bilge Water Management System
Issued 10 December 2002
Resolved
Properly installcheck/stop check valves in the two emergency bilge suction lines (one port & one starboard). To be completed to the satisfaction of the attending marine inspector but no later than 10 Jan 03. LEGACY COMPONENT DESC: Valve
Stability › Watertight Integrity
Issued 28 October 2002
Resolved
Properly install (Watertight) or remove wires and repair holes (3) in collision bulkhead and forward bulkhead.
Engineering › Bilge Water Management System
Issued 28 October 2002
Resolved
Make proper repairs to deteriorated section of Bilge suction line, located in engine room, for #6 void space. LEGACY COMPONENT DESC: Piping
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 April 2002
Resolved
Replace cover to control panel to water pump in engine room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 April 2002
Resolved
Replace panel covers to distribution panels in engine room.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 April 2002
Resolved
Cap outlet boxes in engine room.
Fire Fighting › Miscellaneous Items
Issued 16 April 2002
Resolved
Provide spanner wrench for fire main stations. LEGACY COMPONENT DESC: Spanner wrench
Engineering › Bilge Water Management System › Manifold
Issued 16 April 2002
Resolved
Properly label the bilge manifold system.
Engineering › Bilge Water Management System
Issued 16 April 2002
Resolved
Prove proper operation of bilge pump and piping system. LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System
Issued 16 April 2002
Resolved
Instal and prove proper operation of high level alarms. LEGACY COMPONENT DESC: high level alarms
Fire Fighting › Miscellaneous Items
Issued 16 April 2002
Resolved
Replace flame screen 30 X 30 mesh to day tank fuel vent. LEGACY COMPONENT DESC: flame screens
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 April 2002
Resolved
Mark fuel shut off valves accordingly.
Navigation › Collision/Grounding Avoidance
Issued 16 April 2002
Resolved
Provide proper size (300 mm) bell near pilot house. LEGACY COMPONENT DESC: bell
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 April 2002
Resolved
Service all portable fire extinguishers.
Documentation › Markings/Placards
Issued 16 April 2002
Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: Emergency Broadcast
Lifesaving › Buoyant Apparatus
Issued 16 April 2002
Resolved
Provide proper 21 and over weaklink to starboard sea painter. LEGACY COMPONENT DESC: Weaklink
Accommodation/Occupational Safety › Occupational Safety
Issued 16 April 2002
Resolved
Repair door hatch to pilot house LEGACY COMPONENT DESC: door handles
Lifesaving › Buoyant Apparatus
Issued 16 April 2002
Resolved
Ensure sea painters are configured properly to the BAs and the BAs are spaced accordingly.. LEGACY COMPONENT DESC: sea painter
Lifesaving › Liferaft Equipment
Issued 16 April 2002
Resolved
Mark oars with vessel's name and attach two to a lifefloat. LEGACY COMPONENT DESC: Oars
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 April 2002
Resolved
Mark storage of children and adult lifejackets accdordingly.
Engineering › Bilge Water Management System › Pump
Issued 16 April 2002
Resolved
Provide portable bilge pump that will reach the bottom of the forepeak.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 April 2002
Resolved
Ensure lifebuoy ring is repaired.
Engineering › Bilge Water Management System › Pump
Issued 16 April 2002
Resolved
Remove or replace submersible bilge pumps. If replaced, ensure positive stop closure valves are installed at the overboard discharge through hull.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2002
Resolved
Remove all extension cords (2-E/R, galley, pilot house, tv, and reefers)
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2002
Resolved
Remove power cords from the galley and pilot house.
Documentation › Logs/Records
Issued 16 April 2002
Resolved
Provide proof of log entries for MOB, fire drills, and emg steering.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 April 2002
Resolved
Provide copy of tides, currents, light list, charts, and coast pilot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2002
Resolved
Remove all dead end wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2002
Resolved
Ensure fire pump is hard wired directly to an outlet box.
Communications › Radio Communications
Issued 16 April 2002
Resolved
Renew NOAA registration to EPIRB and replace battery. Show proof of servicing record.
Vsl restricted to no more than 3 miles from shore. LEGACY COMPONENT DESC: EPIRB
Documentation › Markings/Placards › Capacity Marking
Issued 16 April 2002
Resolved
Ensure that second deck is marked accordingly for the number of passengers listed on the Stability Letter.
Engineering
Issued 17 April 2000
Resolved
TIGHTEN FUEL SUPPLY LINE CONNECTION TO THE PORT MAIN DIESEL ENGINE.
Engineering
Issued 17 April 2000
Resolved
REPLACE DAMAGED FLEXIBLE FUEL RETURN LINE TO STARBOARD MAIN ENGINE.
Documentation
Issued 16 April 1998
Resolved
VESSEL TO PROVIDE SATISFACTORY DOCUMENTATION INDICATING COMPLIANCE WITH ALLDRUG TESTING REQUIREMENTS.
Engineering
Issued 16 April 1998
Resolved
PROPERLY LABEL EMERGENCY FUEL OIL SHUTOFFS AND PASSENGER CAPACITY OF UPPER DECK.
Lifesaving
Issued 17 April 1996
Resolved
MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODEING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREW MEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Lifesaving
Issued 17 April 1996
Resolved
LABEL UPPER DECK CAPACITY PLATE.
Lifesaving
Issued 17 April 1996
Resolved
REINSTALL REFLECTIVE MATERIAL ON THE BUOYANT APPARATUS AS POINTED OUT BY THE INSPECTOR.
Engineering
Issued 17 April 1996
Resolved
REPLACE FLAME SCREEN ON THE AFTER FUEL OIL TANK.
Lifesaving
Issued 17 April 1996
Resolved
REPAIR OR REPLACE 2 RING BUOYS WITH HOLES.
Engineering
Issued 19 April 1995
Resolved
REPLACE PRESSURE GAUGE TO AIR COMPRESSOR AND PROVE PROPER OPERATION OF RELIEF VALVE NO LATER THAN 01 MAY 1995.
Navigation
Issued 19 April 1995
Resolved
PROPERLY CONNECT STEERING GEAR NO LATER THAN 01 MAY 1995 (WITH COTTER PINS OR DOUBLE NUT).
Lifesaving
Issued 19 April 1995
Resolved
PRIOR TO OPERATION, PROVIDE NEW PFD'S IN SUFFICIENT NUMBER TO COMPLY WITH CERTIFICATE OF INSPECTION.
Lifesaving
Issued 19 April 1995
Resolved
RENEW IN KIND, ROTTED GRAB LINES ON TWO RING BOUYS, PRIOR TO OPERATION.
Construction/Loadline
Issued 14 March 1995
Resolved
APPROXIMATE 2' X 6' X 3/8" INSERT PLATE INSTALLED IN BOTTOM ON PORT SIDE OFKEEL OUTBOARD 2' AND FROM TRANSOM TO 6' FORWARD.
Navigation
Issued 19 April 1994
Resolved
PROVE PROPER OPERATION OF AVENGER III LORAN C.
Electrical
Issued 19 April 1994
Resolved
PRIOR TO VESSEL'S OPERATION, PROVE PROPER OPERATION OF SHIPS SERVICE GENERATOR.
Lifesaving
Issued 19 April 1994
Resolved
REMOVE OUTDATED CLASS A EPIRB FROM VESSEL.
Construction/Loadline
Issued 12 April 1994
Resolved
PROVIDE RESULTS OF BELT HULL GAUGINGS. PERFORM BELT GAUGINGS MINIMUM OF SEVEN BELTS, ONE IN EACH WATER TIGHT COMPARTMENT, AND TWO IN THE ENGINE ROOM. START AT WIND AND WATERLINE AND GO TO KEEL ENSURING AT LEAST TWO GAUGINGS IN EACH PLATE IN EACH COMPARTMENT.
Construction/Loadline
Issued 19 April 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE MAKE PERMANENT REPAIRS TO PORT MAIN ENGINE CLUTCH DRIVEN BILGE/FIRE PUMP AND PROVE OPERATIONAL TO ATTENDING COAST GUARD MARINE INSPECTOR AND NOT LATER THAN 24 APRIL 1993.
Lifesaving
Issued 24 April 1992
Resolved
CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE AND ABANDON SHIP PRIOR TO CARRYING PASSENGERS. DRILLS ARE TO BE CONDUCTED IN THE PRESENCE OF A U. S. COAST GUARD MARINE INSPECTOR AND COMPLETED NO LATER THAN 24 MAY 92.
Lifesaving
Issued 25 April 1990
Resolved
INSTALL PENDANTS AS NEEDED ON LIFEFLOATS.
Construction/Loadline
Issued 25 April 1990
Resolved
REPAIR E/R AND STOREROOM HATCHES.
Construction/Loadline
Issued 25 April 1990
Resolved
ADJUST SCUTTLE TO FUEL TANK SPACE
Lifesaving
Issued 25 April 1990
Resolved
INSTALL ADDITIONAL WEAK LINK FOR LIFEFLOATS.
Navigation
Issued 25 May 1989
Resolved
VESSELS RADIO, RADAR, LORAN, DEPTHSOUNDER NOT INSTALLED.
Construction/Loadline
Issued 25 May 1989
Resolved
CENTER PILOT HOUSE WINDOW MISSING.
Construction/Loadline
Issued 22 April 1986
Resolved
CAP OLD BAIT BOX DRAIN LINE IN #2 COMPARTMENT
Engineering
Issued 22 April 1986
Resolved
PROVIDE AN ADDITIONAL FIXED POWER BILGE PUMP
Casualty record · 3
10 December 2002Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 1717619
13 October 2025Routine · role: Involved in a Marine Casualty · 1 injured · activity 8259484
4 July 2026Routine · role: Involved in a Marine Casualty · activity 8431753
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.