Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5808
Flag
UNITED STATES
Maury page id
psix-47180

Documentation record

Registered dimensions (L × B × D)83.8 ft × 22.0 ft × 6.6 ft
Registered tonnagegross 77 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEW BERN SHIPYARDS INC · NEW BERN, NC, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 18 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 75 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

4 July 2026 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8431753
21 October 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8256541
13 October 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8259484
30 September 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8225506
13 November 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8034535
7 October 2024 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8151108
25 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967026
5 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7874569
6 November 2023 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7821070
31 May 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701719
9 March 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648653
6 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7425288
6 December 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363492
17 May 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7203011
10 November 2020 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7093314
7 April 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923888
28 September 2018 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6550817
10 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537114
5 September 2018 Hull Examination · Annual Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6531303
7 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6407938
5 April 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118245
30 December 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064029
15 September 2016 Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6001433
10 February 2016 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813112

Deficiency record · 75

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 September 2025 Resolved
Fire pump pressure gauge is nonfunctional. Replace gauge to properly show 60 psi operating pressure. 46 CFR 181.10-1 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 16 October 2025
Resolution: Fire main pressure gauge is now operating above 60 psi.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 September 2025 Resolved
Vessel did not have charts available. Make charts available. 46 CFR 184.420 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 7 October 2025
Resolution: Charts were made available.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Electrical equipment must be installed to protect from electrical hazards. Vessels shore side electrical connection was missing cover and the electrical box is extremely corroded. Replace electrical connection cover and box.46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 20 November 2025
Resolution: Electrical shore connection has been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2025 Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Several life float paddles were damaged and not labeled with the vessel name. Replace damaged paddles and label accordingly. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 13 October 2025
Resolution: New paddles have been purchased, labeled and attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025 Resolved
Both port and stbd reduction gear shifting cables were found improperly attached with a wooden brackets. Provide each reduction gear shifting cable with permanent metal supports. 46 CFR 182.220
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 20 November 2025
Resolution: Reduction gear brackets are now made of steel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025 Resolved
Both drip less shaft seals were found with non-approved water hose attached from the main engine. Replace both hoses with approved water hose. 46 CFR 182.720
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 7 October 2025
Resolution: Water hose has been replaced for port and stbd shaft seals.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2025 Resolved
The fire extinguisher installed in the engine room was found to be a 2-A. Provide the engine room with a 40-B:C. 46 CFR181.500
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 7 October 2025
Resolution: Proper portable fire extinguisher has been placed in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring in FWD Hold, portside had exposed dead end wire. Properly remove or cover to prevent potential shock or fire hazards and update date wiring diagram. 46 CFR 183.200.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 20 November 2025
Resolution: Dead end wire has been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical outlet in FWD Hold, portside was missing cover. Properly cover outlet socket. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 7 October 2025
Resolution: Electrical outlet now has a cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Two overhead lights are being powered by an extension cord. Remove extension cord and install permanently electrical outlet to power the lights and update date wiring diagram. 46 CFR 183. 200(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 20 November 2025
Resolution: Extension cord has been removed, and an outlet has been permanently installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Vessel is in the process of installing new electrical generators. Provide electrical plans for vessel’s power distribution. 46 CFR 177.202.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 25 November 2025
Resolution: Electrical plans have been submitted and approved for the generators.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 September 2025 Resolved
The sewage tank overboard discharge piping was found with epoxy on the welds. The overboard piping was found with ratchet straps used as support. Provide piping with permanent piping support brackets and make weld repairs to failed area on sewage tank piping. Repair at next drydock. 46 CFR 184.704
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 November 2025
Resolution: Sewage piping has been renewed, and permanent piping support has been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. In the FWD holed MI found old, used transducer in the portside bilge. At next dry-dock remove old transducer to prevent possible flooding hazards. 46 CFR 176.830
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 October 2025
Resolution: Transducer has been rewired and put into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2024 Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings. Fuel lines to both generators were attached to fitting with hose clamps. Replace with factory assembled hoses.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2024
Resolution: Fuel lines were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2024 Resolved
Engine room flooded with approximately 6 feet of water while at the dock due to a failed hose. repair or replace affected equipment and conduct operation test in the presence of marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2024
Resolution: 0/0 replaced affected equipment and an operational test was conducted on annual inspection.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 March 2024 Resolved
EPIRB battery is expired. Replace the battery on the EPIRB. Vessel is restricted to no more than 3NM from shore until rectified. Cite: 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 6 March 2024
Resolution: Vessel acquired a new EPIRB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024 Resolved
Vessel did not have alcohol test swabs on board. Vessel is restricted to voyages that will prevent crew from getting to alcohol testing ashore within two (02) hours of an incident until rectified. Cite: 46 CFR 185.212
Action required: 705 - Other - as specified
Resolved 6 March 2024
Resolution: Vessel acquired new swabs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2024 Resolved
Both generator fuel return fuel filters are installed without flame impingement bowls. Install manufacturer approved flame impingement bowls for all non-metallic fuel filters that do not currently have them equipped. Cite: 46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 13 March 2024
Resolution: Bowls were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024 Resolved
Two (02) power-taps were located under the main console in the pilothouse. Remove the identified power-taps in the pilot house. Cite: 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 6 March 2024
Resolution: Vessel acquired UL listed surge protectors to replace the power taps and plans to replace them with permanent installations within 30 days.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024 Resolved
Main engine room distribution panel had an open/bare breaker opening. Install a blank cover or fuse for the opening on the affected distribution panel. Cite: 46 CFR 183.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Vessel installed a blank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024 Resolved
“Wire nuts” were utilized for wire terminations in the utility closet on the portside of the main deck. Either place these connections in junction boxes or replace the “wire nuts” with pressure type connectors. Cite: 46 CFR 183.340(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Pressure connectors were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2024 Resolved
Ring buoys were found to have insufficient retro reflective tape. Replace the retro tape on affected ring buoys. Cite: 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Additional retro tape was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2024 Resolved
Various items were missing from the first aid kit. Replace missing items in first aid kit. Cite: 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 13 March 2024
Resolution: A new first aid kit was acquired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 March 2024 Resolved
Vessels charts and nav pubs are out of date. Provide up to date charts and nav pubs. Cite: 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 7 March 2024
Resolution: Up-to-date charts and pubs were acquired.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 November 2023 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Found several watertight bulkheads with wire runs penetrating the bulkhead. Make all watertight bulkheads watertight.
Action required: 705 - Other - as specified
Resolved 6 December 2023
Resolution: Corrected as required - [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 March 2023 Resolved
All exposed hazards, such as gears or rotating machinery, must be properly protected by a cover, guard or rail. Must install guard over the port main engine rotating belt head.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 17 March 2023
Resolution: Verify by emailed pics
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2023 Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least one (01) inch numbers and letters at the entranceway to that deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 17 March 2023
Resolution: Verified by emailed pics
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2022 Resolved
FLOATING WATERLIGHT FOR PORT INBOARD LIFEFLOAT ARRANGEMENT WAS INOP DURING INSPECTION. CREW REPLACED BATTERY BEFORE CONCLUSION OF INSPECTION.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 11 December 2020 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Steering gear void space; Bilge suction strainer coroded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2021
Resolved 16 December 2020
Resolution: Deficiency satisfied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2020 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. Cap fuel piping from unused fuel tank in steering gear void (or make/mark fuel shut off reach rod operable).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2021
Resolved 16 December 2020
Resolution: Deficiency satisfied.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2020 Resolved
Each hose must be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies. Replace STBD side main deck fire hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2021
Resolved 16 December 2020
Resolution: Deficiency satisfied.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2020 Resolved
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required. Replace Main deck Portable Fire extinguisher found rusted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2021
Resolved 16 December 2020
Resolution: Deficiency satisfied.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020 Resolved
Remove extension cord from forward void leading to refer box. Secure wiring at 24 inch intervals. Due 07July2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Removed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 April 2020 Resolved
Install guards around compressor wheels/belt in forward tank void. Due 07July2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Compressor removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2020 Resolved
Install flame impingement bowl on generator fuel filter. Due 07July2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 April 2020 Resolved
Service fuel shutoff valves. Due 07July2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020 Resolved
Mount battery behind generator to prevent falling. Due 07July2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2020 Resolved
Crop out burnt cable in tank room void. Secure wiring at 24 inch intervals. Due 07July2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Removed wire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2020 Resolved
Replace floating water light batteries on ring buoy and life float. Due 07July2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 5 May 2020
Resolution: Replaced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 December 2018
Resolution: No longer in VIVS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 September 2018 Resolved
C/R wasted void vents/fills on main deck X 4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Replaced vents/fills.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 September 2018 Resolved
Prove proper operation of fire pump with 2 hoses at 50 psi.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2019
Resolution: Verified new pump installation and operation.
Fire Fighting › Fire Pumps › Arrangement
Issued 7 May 2018 Resolved
Provide controls for fire pump operation at the operating station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 6 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 May 2018 Resolved
Demonstrate proper operation of the mast headlight
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 6 June 2018
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 May 2018 Resolved
Make proper repairs to leaking MSD pipe.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 6 June 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 May 2018 Resolved
Provide plans for approval for the new exhaust installations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 18 June 2018
Construction/Loadline › Structures › Superstructure
Issued 7 May 2018 Resolved
Remove jagged hand rails on the outside of the bridge cat walk.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 18 June 2018
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 7 May 2018 Resolved
Maintain MSD overboard valve closed within 3NM of land. Valve was found in the open position inport at the dock at Seafourth Landing Mission Bay San Diego. This was corrected on the spot by the diection of the attending MI
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: MSD ovbd valave was closed by the direction of the attending MI
Construction/Loadline › Structures › Superstructure
Issued 7 May 2018 Resolved
Provide a handle for the water tight hatch to the MSD space
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 18 June 2018
Lifesaving › Hand Flares › Expired
Issued 5 April 2017 Resolved
Provide non-expired distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 April 2017 Resolved
Replace cover for generator battery.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 April 2017 Resolved
Make lifebuoy light operational.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 April 2017 Resolved
Provide master with Marine Radio Operator Permit.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: Provided Marine Radio Operator Permit for master
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2017 Resolved
EPIRB drills have not been logged.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 April 2017 Resolved
Fix railing in navigational area.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Documentation › Markings/Placards › Warning Signs
Issued 5 April 2017 Resolved
Emergency broadcast placard is missing.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 April 2017 Resolved
Replace all retro reflective tape on lifefloats.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Lifefloat › Float-free Link
Issued 5 April 2017 Resolved
Provide float-free link with proper tags.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 15 May 2017
Resolution: Provided proper tags on float-free links.
Lifesaving › Lifefloat › Serviceable
Issued 5 April 2017 Resolved
Replace or service 02 lifefloats.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 April 2017 Resolved
Label forward lifejacket storage compartment.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Lifefloat › Markings
Issued 5 April 2017 Resolved
Stencil name onto liferafts.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 April 2017
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 5 April 2017 Resolved
Survival craft needs to be ready for immediate use. Install ladder to access lifefloats.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: Installed ladder to access the survival crafts.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017 Resolved
Make bilge alarm in the forward galley operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Operations/Management › Drills/Instruction › Fire
Issued 5 April 2017 Resolved
Crew requires fire fighting training for equipment operations and protocol.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 5 April 2017 Resolved
Provide fire pump with 50 GPM pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 September 2016 Resolved
Add courses no greater than 4 inches between each around the wheelhouse.
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 19 October 2016
Documentation › Certificates/Documents › Stability Letter
Issued 11 February 2016 Resolved
Post stability letter at the operating station
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 22 February 2016
Resolution: Stability letter properly posted on the bridge
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2016 Resolved
1. The vessel is severely overdue for required annual inspection. Conduct annual inspection prior to carrying passengers for hire
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 February 2016
Resolved 11 February 2016
Resolution: Completed annual inspection
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 February 2016 Resolved
Properly mark all life jacket stowage lockers
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 22 February 2016
Resolution: Owner properly marked all life jacket stowage lockers
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2016 Resolved
Provide guards on all rotating machinery in the engine room;main shafts, bilge pumps.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 22 February 2016
Resolution: Guards installed on all rotating machinery
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2016 Resolved
Provide di=electric matting for generator electrical disrubution panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 22 February 2016
Resolution: Di-electric matting was placed on deck in front of main distribution panel.
Lifesaving › Lifebuoys › Serviceable
Issued 10 February 2016 Resolved
renew upper life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 February 2016
Resolution: Upper life ring buoy was replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 February 2016 Resolved
Renew all batteries for water lights on life ring buoys and life floats
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 February 2016
Resolution: All batteries were renewed
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 February 2016 Resolved
Provide current FCC radio telephony safety certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: FCC safety certification was renewed
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 10 February 2016 Resolved
Provide radio operators permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 February 2016
Resolution: Radio operator permit was renewed.