Records from 1985 to 1992. Most recent: inspection, 27 October 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
27 October 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 952808
5 April 1990
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1239604
28 March 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1243442
10 October 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 998921
13 June 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1036495
16 May 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1205132
7 July 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 897472
24 May 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1196519
13 October 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1319974
31 August 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1338972
21 August 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1030992
9 August 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1338082
3 April 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1030972
7 October 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1005647
3 October 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1006283
22 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1309927
31 July 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 999725
19 August 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 983226
30 July 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1288607
Engineering
Issued 13 June 1989
Resolved
VESSEL DOES NOT HAVE AN OPERABLE 25 GPM BILGE PUMP.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
REQUIRE A WATER TIGHT CONTAINER FOR THE FLARES.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Electrical
Issued 13 June 1989
Resolved
A BATTERY CABLE THAT IS NO LONGER USED NEEDS TO BE REMOVED.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Construction/Loadline
Issued 13 June 1989
Resolved
STBD STERN AREA HAS BEEN DAMAGED BY BANGING AGAINST THE DOCK.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Engineering
Issued 13 June 1989
Resolved
REPLACE THE STBD ENGINE AND OUT DRIVE.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
REQUIRED AN ADDITIONAL 22 ADULT AND 2 CHILDERN PFDS
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
PFD STORAGE WAS NOT PROPERLY MARKED.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
REQUIRE TWO ADDITIONAL RED FLARES.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Lifesaving
Issued 13 June 1989
Resolved
REQUIRE THREE ADDITIONAL ORANGE SMOKE.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Navigation
Issued 24 May 1988
Resolved
RECONNECT STBD STEERING ROD.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Fire Fighting
Issued 24 May 1988
Resolved
SERVICE ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Accommodation/Occupational Safety
Issued 24 May 1988
Resolved
REPLACE BROKEN WINDOWS WITH TEMPERED GLASS WINDOWS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988
Resolved
ONE VENTILATION DUCT IN EACH OF THE ENGINE COMPARTMENTS SHALL EXTEND TO A POINT NEAR THE BOTTOM OF THE COMPARTMENT.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988
Resolved
REMOVE EXCESS OIL FROM THE STBD BILGE.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988
Resolved
RECONNECT THE PORT EMERGENCY FUEL SHUT OFF.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
PROVIDE 6 HAND RED FLARES AND 6 ORANGE SMOKE DISTRESS SIGNALS OR 12 COMBINATION RED FLARES AND ORANGE SMOKE DISTRESS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
PROVIDE WATERTIGHT CONTAINER FOR THE DISTRESS SIGNALS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 9 August 1987
Resolved
PROVIDE 2 ADULT LIFE PRESERVERS. TOTAL PERSONS ALLOWED REDUCED TO 101 UNTIL NEW LIFE PRESERVERS ARE PLACED ON BOARD.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Navigation
Issued 9 August 1987
Resolved
STARBOARD STEERING UNIT TO BE REPAIRED.
Condition: Unknown
Due 9 August 1987
Resolved 9 August 1987
Documentation
Issued 22 September 1986
Resolved
PROVIDE EVIDENCE THAT VESSEL IS PROPERLY DOCUMENTED WITH THE COAST GUARD REGIONAL DOCUMENTATION CENTER.
Condition: Unknown
Due 22 September 1986
Resolved 22 September 1986
Construction/Loadline
Issued 31 July 1986
Resolved
REPAIR FAUCETS IN MALE/FEMALE HEADS
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Documentation
Issued 31 July 1986
Resolved
PROVIDE VALID FCC RADIO LICENSE.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Accommodation/Occupational Safety
Issued 31 July 1986
Resolved
THROUGH BOLT UPPER DECK STBD. RAIL EXIT TO PREVENT CHILDREN'S TAMPERING.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Lifesaving
Issued 31 July 1986
Resolved
PROVIDE 22 ADULT LIFE PRESERVERS. PASSENGER CAPACITY REDUCED TO 76 PERSONSUNTIL NEW LIFE PRESERVERS ARE PLACED ON BOARD.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Lifesaving
Issued 31 July 1986
Resolved
REPAIR UNDERSEAT LIFEJACKET STOWAGE TO PROVIDE FOR VENTILATION AND KEEP LIFE PRESERVERS OFF DECKING.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Electrical
Issued 31 July 1986
Resolved
REMOVE ALLIGATOR CLIPS FROM STBD. BATTERY BOX AND PROVIDE PERMANENT INVERTER CONNECTIONS.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Navigation
Issued 31 July 1986
Resolved
REPLACE STERN LIGHT WITH LIGHT OF APPROVED TYPE WITH CORRECT ARC OF ILLUMINATION.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Accommodation/Occupational Safety
Issued 31 July 1986
Resolved
PROVIDE HORIZONTAL ENCLOSURE OF LOWER TWO-THIRDS OF UPPER DECK RAILS TO PROVIDE CHILREN'S PROTECTION.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Accommodation/Occupational Safety
Issued 31 July 1986
Resolved
SAFETY BOLT MAIN DECK STBD. EXIT DOOR TO PREVENT CHILDREN'S TAMPERING.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Accommodation/Occupational Safety
Issued 31 July 1986
Resolved
TIGHTEN LAG BOLTS HOLDING DOWN UPPER DECK RAILS; ALL AROUND.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Electrical
Issued 31 July 1986
Resolved
REMOVE DEAD WIRE RUNS TO BOTH ENGINE COMPARTMENTS.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Electrical
Issued 31 July 1986
Resolved
REMOVE INVERTER EXTENSION CORDS AND INSTALL PROPER GROUNDED MARINE TYPE RECEPTICLES FOR PORTABLE ELECTRICAL APPLIANCES.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Engineering
Issued 31 July 1986
Resolved
REPLACE PORT FUEL FILL HOSE, PROPERLY GROUNDED, AND DOUBLE HOSE CLAMP AT EACH END.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Engineering
Issued 31 July 1986
Resolved
PROVIDE RIGID, NON-COMBUSTIBLE, INTAKE DUCTING TO PORT/STBD. ENGINE COMPARTMENT RUN TO A POINT JUST ABOVE THE BILGES.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Lifesaving
Issued 30 July 1985
Resolved
PROVIDE 17 ADDITIONAL ADULT PFD'S FOR A TOTAL OF 103.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985