← All vessels
PELAGIC II
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northwest District (CGD-NW) · Other hulls named PELAGIC II
PELAGIC II is a 1972 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1986, most recently in March 2026, along with 42 deficiencies and 1 casualty investigation in 2009.
Records from 1986 to 2026. Most recent: inspection, 18 March 2026.
- Built
- 1972
- Last inspected
- 18 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
539994
WDN6486
47195
Flag
UNITED STATES
368355000
Maury page id
psix-47195
Inspections, by type
…with no type recorded2
Years with a record
37 calendar years (1986–2026)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)42.3 ft × 14.2 ft × 7.7 ft
Registered tonnagegross 35 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH PLASTICS INC · TACOMA, WA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDEER HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN6486MMSI 368355000 · active · compulsorily equipped · granted 2 March 2023, expires 2 March 2033
WDH2044MMSI 338562000 · expired · compulsorily equipped · granted 30 October 2013, cancelled 30 December 2023
WDB5100MMSI 369317000 · expired · compulsorily equipped · granted 26 August 2003, cancelled 9 November 2013
WTY9134MMSI not assigned · expired · compulsorily equipped · granted 25 May 1994, cancelled 25 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
18 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320424
6 May 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8129806
19 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8096583
12 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8092890
21 February 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7870475
8 March 2023
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7651280
22 March 2022
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420731
1 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7167700
22 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7156751
16 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926327
19 March 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636226
20 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6627941
13 March 2018
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370810
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360544
14 March 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108371
23 February 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6098780
4 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5827156
18 March 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4816063
26 March 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3703599
23 March 2009
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3443916
26 March 2008
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3166441
14 March 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2887400
21 February 2007
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2875226
6 February 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2868449
28 February 2006
Simplified Stability Test · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2831824
3 March 2005
Hull Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2306591
25 March 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2029148
17 March 2003
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1757075
14 February 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1486742
5 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1468195
18 February 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1410240
17 March 1999
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384036
17 March 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406459
10 March 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414954
17 March 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404323
14 February 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380760
14 March 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1078563
16 February 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416241
15 March 1995
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1358646
10 March 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1456146
1 February 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 852703
4 October 1993
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1157648
5 February 1993
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 832019
5 February 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1471648
9 April 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 952221
4 February 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943770
13 May 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 927780
25 April 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 929745
26 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1212356
15 March 1991
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1239312
4 February 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995782
9 October 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907149
5 February 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 900374
7 April 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1197236
10 February 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1036900
16 May 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1040304
9 October 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1014386
29 April 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1013157
6 February 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1319530
2 May 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987072
13 March 1986
Re-Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1307646
Deficiency record · 42
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 March 2025
Resolved
"A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter" The vessel has on board 3 electronic red flares that aren't approved in accordance with § 160.021.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 March 2025
Resolved
"Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required... The operator is responsible for the proper operation of the station." The vessels owner/operator never obtained an FCC Radio Operator Permit.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 March 2025
Resolved
"Portable fire extinguishers shall be located so as to be convenient to the space protected." The portable fire extinguisher located at the operating station was not mounted in a bracket and was able to roll freely in the space between the aft window and bench.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 March 2025
Resolved
"The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable." Cables penetrating the top of the bulkhead on the starboard side between the steering gear and engine room were not properly sealed and insulated.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 19 March 2025
Resolved
"The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency..." The vessel's owner/operator did not maintain records or logs pertaining to the adequate training of the crew to respond during an emergency.
Lifesaving › Lifefloat › Float Free
Issued 11 March 2016
Resolved
Re-install float free link arrangement for port life float so painter does not snag on line canister. 46 CFR 180.20-1(a)(2)
Engineering › Bilge Water Management System › Valve
Issued 18 March 2014
Resolved
Overboard bilge discharge valve not properly installed in engine compartment.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 18 March 2014
Resolved
Lifeline inside canister on buoyant apparatus was tangled preventing proper payout.
Documentation › Certificates/Documents › FCC SSL
Issued 30 March 2010
Resolved
Operator is required to have an FCC radio operators license IAW 46CFR184.502. Obtain appropriate license IAW with cite.
Engineering › Bilge Water Management System › Pump
Issued 30 March 2010
Resolved
Portable bilge pump was inoperable when tested. Fix or replace portable bilge pump to operable condition IAW 46CFR182.520(a)
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 March 2009
Resolved
Batteries are not protected from falling objects as required by 46 CFR 183.354(b). Issued 835 requiring owner to provide adequate protection for batteries.
Lifesaving › Lifefloat › Platform
Issued 26 March 2008
Resolved
Repair port LF. Damage appears to be from bird pecking at float material.
Lifesaving › Lifebuoys › Serviceable
Issued 26 March 2008
Resolved
Replace worn out Lifering.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 February 2007
Resolved
Holding tank valve leaking. Refurbish or renew prior to placing vessel back into the water.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 March 2005
Resolved
Owner did not have COD on-board vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 3 March 2005
Resolved
The starboard life-float did not have a CG approved weak link. This shall be corrected prior to carrying more than 24 passengers.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 March 2005
Resolved
The port life float needed a new buoyant line for the waterlight.
Lifesaving › Lifefloat › Paddle
Issued 3 March 2005
Resolved
The paddles for the p/s life floats needed to be attached.
Lifesaving › Lifefloat › Serviceable
Issued 3 March 2005
Resolved
The vessel's life ring and p/s life floats needed to be repaired.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 March 2005
Resolved
The life ring needed retro reflective tape.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 March 2005
Resolved
The engine room fixed fire extinguishing system must be capable of shutting engines down upon discharge.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 March 2005
Resolved
Two life jackets need to be marked with vessel's name.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2005
Resolved
The children's life jackets must be stowed separately from the adult life jackets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 3 March 2005
Resolved
Vessel needs life jacket donning placards.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 March 2005
Resolved
Magnetic compass light was inoperable and needs to be replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 March 2005
Resolved
Vessel must obtain CG light list.
Lifesaving › Lifebuoys
Issued 17 March 2003
Resolved
The life bouy was deteriorated beyond repair and needs to be replaced.
Lifesaving › Rigid Liferafts
Issued 17 March 2003
Resolved
Surface of life float is deteriorated and needs to be repaired. LEGACY COMPONENT DESC: Buoyant Material
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 March 2003
Resolved
Vessel had improper type of fire extinguisher in the galley and must replace it with a type A-II/B-II.
Engineering › Bilge Water Management System
Issued 14 February 2002
Resolved
NO VISUAL AND AUDIBLE BILGE ALARMS. LEGACY COMPONENT DESC: Interface Detector
Electrical › Lighting (service)
Issued 14 February 2002
Resolved
INPROPER LIGHTS INSTALLED IN ENG ROOM. NOT UL APPROVED. LEGACY COMPONENT DESC: Lighting Fixture
Construction/Loadline
Issued 16 February 1996
Resolved
IAW 46CFR171.124 THE AFT HARTCH TO THE STEERING COMPARTMENT MUST BE MADE WATERTIGHT & HAVE A SECURING DEVICE ATTACHED.
Documentation
Issued 5 February 1993
Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION
Electrical
Issued 5 February 1993
Resolved
INSTALL BATTERY BOX FOR BOOSTER BATTERY IN CENTER OF ENGINE ROOM
Construction/Loadline
Issued 5 February 1993
Resolved
REPAIR HOLES IN WATERTIGHT BULKHEAD BETWEEN LAZARETTE AND ENGINE ROOM_x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 4 February 1992
Resolved
LOOSE AND IMPROPERLY ENDED WIRE
Engineering
Issued 4 February 1992
Resolved
EMERG STOP CABLE ON PORT ENGINE WORN.
Navigation
Issued 4 February 1992
Resolved
STEERING TIE BAR ON PORT RUDDER POST NOT DOUBLE BOLTED OR COTTER PINNED
Unknown
Issued 4 February 1992
Resolved
CRACKS IN STAINLESS STEEL RAILING.
Construction/Loadline
Issued 25 April 1991
Resolved
REDUCE AFTER DECK CANOPY TO A LEGNTH NOT EXCEEDING 18.5 FEET AFT OF THE MAIN CABIN.
Construction/Loadline
Issued 4 February 1991
Resolved
CONDUCT SIMPLIFIED STABILITY TEST TO ACCOUNT FOR RECENT ADDITION OF CANOPY STRUCTURE ON STERN OF VESSEL, OR REMOVE CANOPY STRUCTURE. TO BE ACCOMPLISHED PRIOR TO PLACING VESSEL BACK INTO SERVICE, BUT NO LATER THAN 19MAR91.
Lifesaving
Issued 6 February 1987
Resolved
MAXIMUM PASSENGERS ALLOWED SHALL REMAIN AT 22 UNTIL THE WORKLIST DATED 06FEB87 IS COMPLETED.
Casualty record · 1
29 September 2009Routine · role: Involved in a Marine Casualty · activity 3606855
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
WESTERN PRINCE II (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.