Records from 1984 to 2025. Most recent: inspection, 29 May 2025.
Inspection history · 127
29 May 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8135388
9 January 2025
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8060046
15 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8016718
12 June 2024
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7933519
8 May 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7907612
11 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7824116
11 November 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7824122
7 September 2023
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7787136
2 May 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7625974
31 March 2023
Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7631911
9 February 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7635162
2 February 2023
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7625972
28 December 2022
Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613957
8 November 2022
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7591720
12 September 2022
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7557008
19 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7482296
3 February 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7368749
17 September 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7314847
30 July 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7256055
5 April 2021
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7165151
17 December 2019
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6875501
16 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6817096
12 July 2019
Damage Survey · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6747186
18 April 2019
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6659822
18 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6665642
27 March 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6358912
26 April 2017
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127818
18 April 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127667
13 September 2016
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6000042
31 July 2016
Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5959980
30 March 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5843298
22 August 2014
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4965569
12 August 2014
Type not recorded
No type recorded · USCGC EDISTO (WPB 1313) · USCG Southwest District (CGD-SW) · Activity 4969788
9 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4340725
29 December 2011
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4216993
7 August 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4109531
19 January 2010
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3665671
28 December 2009
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3656173
14 April 2009
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3476259
20 September 2008
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3331787
21 February 2008
Hull Examination · Deficiency Check · Simplified Stability Test · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3151271
10 April 2007
Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2905493
27 September 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2789893
31 July 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2732060
10 July 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2709873
21 April 2006
Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2630237
24 February 2005
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2298609
23 February 2005
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2298168
25 January 2005
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2280172
21 December 2004
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2263341
10 June 2004
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2094782
5 May 2004
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2060228
27 April 2004
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2054441
12 April 2004
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2044132
29 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1782176
26 February 2003
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1749758
18 December 2002
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1721183
22 October 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1694472
23 May 2002
Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1660360
7 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1613908
22 May 2001
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1064866
10 May 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395719
27 February 2001
Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366099
5 February 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369990
4 January 2001
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1056907
25 August 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421918
13 August 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 108
22 February 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393344
11 February 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365580
8 January 2000
Type not recorded
No type recorded · CGC POINT BRIDGE · USCG Southwest District (CGD-SW) · Activity 1517359
11 October 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 37864
29 June 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1079865
18 May 1999
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360882
25 April 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 151116
1 March 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 797421
10 February 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 122381
10 February 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372493
17 January 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 71538
8 January 1999
Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364967
19 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 43966
10 February 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388471
9 February 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1107527
27 July 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 23680
13 February 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1448860
6 January 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354074
27 February 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427189
4 January 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437042
3 July 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 73611
20 May 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 46930
2 March 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355151
16 February 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1455253
4 January 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355091
26 June 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 96801
21 June 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022110
5 May 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 221739
5 May 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 221947
18 February 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405554
6 January 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1431311
1 March 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376945
27 May 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 13976
19 April 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353374
2 April 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1269889
13 February 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376865
6 March 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901168
11 February 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 906714
7 January 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223323
22 February 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928191
19 January 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1243070
8 January 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213847
3 March 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1197079
24 February 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1044671
7 February 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1338215
15 April 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1340575
31 March 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992726
1 March 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1026379
11 February 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1020588
7 January 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011850
26 February 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1311443
23 January 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308034
16 December 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1333645
29 September 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321095
13 March 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 993187
20 February 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990045
31 January 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294641
16 May 1985
Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 984515
25 March 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 986482
20 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284343
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 May 2025
Resolved
A system protecting a manned space must be fitted with an approved time delay and alarm arranged to require the alarm to sound for at least 20 seconds or the time necessary to escape from the space, whichever is greater, before the agent is released into the space. Alarms must be conspicuously and centrally located. The alarm must be powered by the extinguishing agent. Vessel's fixed fire shutdown for all four engines was inconsistent during testing. Provide fire service technician report attesting to system service and testing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2025
Resolution: Relays replaced and fire service testing and report received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring Buoy's grab lines are UV damaged. Replace ring life buoy and life line.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 June 2025
Resolution: Vessel replaced ring buoy and life line.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 29 May 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Safetyradiotelephony cert was expired. Get new insepction and certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
Resolution: Beacon completed repairs and completed inspection. Issued 10 June 2025.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First Aid kit does not meet ISO 18813:2006 (4.12) or equivalent. Provide first aid kit as per ISO Standard 18813:2006 or equivalent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 June 2025
Resolution: Vessel provided first aid kit contents list and ISO equivalent contents.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 29 May 2025
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan.(b) Each garbage management plan under paragraph (a) of this section must be in writing and—(1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77;(2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and(3) Designate the person who is in charge of carrying out the plan. Provide garbage management plan to inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
Resolution: Garbage management plan provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and
and systems, including the following:(a) Inspection of
of all cable as far as practicable without undue disturbance of the cable or electrical apparatus;
Accommodation lighting junction boxes are missing cable
glands and over junction box limit. Provide line diagram
of vessel's electrical distribution for the accommodation bunk room to verify circuit design and
overcurrent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 23 June 2025
Resolution: Vessel is completing drawings and MI and vessel will revisted upon completion.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Monthly inspections required by NFPA 10 may be conducted
by the owner, operator, person-in-charge, or a designate
member of the crew. Vessel added the monthly fire
inspections into the underway checklist.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 May 2025
Resolution: Vessel added to captain's attestation checklist.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact
with energized parts. Vessel's operating station crew
bunks had undocuemented 12 vdc terminals supplying fans
and usb outlets. Vessel removed power supply and
disconnected all wiring from service.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 May 2025
Resolution: Vessel removed operating station crew bunk VDC exposed terminals and wiring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel is missing emergency radio broadcast placard. Create and post placard IAW 46 CG 184.510 Recommended Emergency Broadcast Instruction to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
Resolution: Broadcast placard posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected smoke detectors in the galley and lazarette did not activate while testing the machinery space detector. Repair smoke detectors and provide test to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Verified galley and lazarette interconnected function.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:(i) Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Lazarette fire extinguisher service date was Feb 2023 and beyond annual NFPA servicing requirement. Provide valid servicing record to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Serviced by IFS on 8May24.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2024
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Four life jacket lights did not activate upon testing. Provide valid test of life jacket lights to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: (4) lifejackets lights were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2024
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Corrosion-resistant nozzle onboard vessel was leaking and not functioning as designed. Provide replacement corrosion-resistant nozzle for required fire hose to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Hose replaced and all (3) nozzles.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 8 May 2024
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. Vessel master could not provide proof of chemical testing consortium enrollment. Provide valid chemical testing enrollment to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 4 June 2024
Resolution: Vessel master onboard during inspection is now enrolled in PEACE consortium.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2024
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel had several combustible waste receptacles onboard. Remove all combustible waste receptacles and replace with non-combustible type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 4 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 May 2024
Resolved
A Certificate of Documentation is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. COD was expired onboard the vessel. Provide valid COD to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 June 2024
Resolution: Vessel provided photo evidence of valid COD.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2024
Resolved
The Rules concerning shapes shall be complied with by day. Vessel is required to carry shapes for signaling purposes for restricted in ability to maneuver (ball, diamond, ball) and vessel not under command (ball, ball). Provide day shapes to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 June 2024
Resolution: Vessel provided photo evidence of day shapes.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 May 2024
Resolved
The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;(b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and(c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel could not provide any previous test records for the required EPRIB monthly test. Vessel master provided new inspection log and performed monthly inspection on site. Deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel conducted EPIRB test on site and recorded in montly log.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 May 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the by the owner, operator, person-in-charge, or a designate member of the crew. Vessel could not provide any record of required NFPA monthly portable fire extinguisher inspections. Vessel master did provide new monthly log and performed and recorded the inspection on site. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel completed monthly inspection on site. Found one extinguisher in the lazarette service expired. Vessel logged in monthly inspection log.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 May 2024
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drills. Vessel could not provide any logs or proof of past completion of fire drills. Fire drill was preformed for machinery space during annual inspection. Master accurately logged the event. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel updated drill log with all three drills completed for annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 May 2024
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel could not provide logs or proof of past completion of MOB or abandon ship drills. MOB and abandon ship drills were conducted during annual inspection. Master accurately logged the event. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel completed all three drills during annual inspection. Master logged all drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The fixed fire suppression system did not shut down the engines or generator in the engine space upon activation of the pressure sensor. Engine space power ventilation is designed to be shut down upon generator shut down. Prior to vessel departure, demonstrate proper operation of engine and ventialtion shut downs upon activation of the fixed fire suppression system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Vessel replaced pressure switch and relay assembly and demonstrated proper operation.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release was found to be two years over expiration date. Provide current hydrostatic release prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Vessel provided new EPIRB hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's anchor light was not functioning. Provide functioning anchor light prior to 16MAY23.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 25 May 2023
Resolution: Vessel installed new anchor light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit analgesic medications were found expired. Provide first aid kit meeting ISO 18813:2006(E).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Vessel provided a new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Provide accurate life jacket location markings of required size.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Vessel marked life jacket locations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. Two dead end cables found under pilothouse console. Remove cables or terminate ends in accordance with 46 CFR 183.320.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Cable was found to be speaker cable which will be used by vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Vessel was unable to provide a current NOAA EPIRB registration. Provide current registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 3 May 2023
Resolution: Vessel renewed registration and provided new registration documentation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 March 2023
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Lower bunk rooms are not fitted with emergency lighting. Provide emergency lighting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel provided emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2023
Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (i) Bulwarks; (ii) Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or (iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Bow gate was found broken off. Replace gate or provide sufficient rail courses.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel repaired and re-installed bow gate.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 March 2023
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. During inspection excessive decay was found in the port side of the engine space, specifically along horizontal hull stiffeners, in way of the deck sink drain penetration and in way of the forward end of the outboard longitudinal deck stiffener. Remove rot to good wood and treat remaining wood.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 12 June 2023
Resolution: Vessel removed rot and treated with Smiths and West System.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2023
Resolved
Suitable storm rails or hand grabs must be installed where necessary in passageways, at deckhouse sides, and at ladders and hatches. The starboard side ladder rail was loose on the external ladder from the main deck to the upper deck. Repair rail.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel repaired rail.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. A wood screw was accidently driven into a 100 Amp circuit cable running through the forward bunk room space. Replace cable in kind or provide plans for modification.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Vessel repaired damaged conduit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023
Resolved
All cable and wire must not be installed with sharp bends. Cable installations throughout vessel were found installed with sharp bends. Remove bends.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel removed sharp bends.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Terminal blocks were found throughout vessel with no protective enclosure. Provide enclosures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel provide protection from shock on terminal blocks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. In-line fuses for watch alarm system were found to be an improper type. Provide approved cartridge type fuses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 2 February 2023
Resolution: Vessel switched fuses to an approved type.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023
Resolved
Each circuit breaker must meet UL 489 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant, and be of the manually reset type designed for: (1) Inverse time delay; (2) Instantaneous short circuit protection; and (3) Switching duty if the breaker is used as a switch. Vessel was unable to demonstrate compliance of newly installed breaker for roving watch alarm system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel removed non-UL listed breaker.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not install an interconnected fire detection system by 27DEC2022.
Vessel is restricted to a LIMITED COASTWISE route until it's compliance with the interconnected fire detection requirements of 46 CFR 181.405 have been verified by a USCG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Vessel installed interconnected fire detection and a rving watch alarm system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 August 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started.
Vessel replaced galley stove/oven, chest freezer and added a dishwasher. Provide data plates showing change in amperage draw for affected circuits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 22 August 2022
Resolution: Vessel provided model numbers.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 August 2022
Resolved
An individual may not be engaged or employed, including self-employment, on a vessel in a position as master, operator, or person in charge for which a credential is required by law or regulation unless all crewmembers covered by this section are subject to the random testing requirements of this section.
Vessel crew included two mariners who were part of a different marine employer's program. Provide documentation that shows marine employer's notification in case of positive random drug testing results.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 27 August 2022
Resolution: Vessel provided current covered crew list showing assigned crew.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 3 February 2022
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must be equipped as required in 47 CFR 80.905(a)(3). Vessel does not have a functioning DSC-MF, DSC-SSB or GMDSS-approved Inmarsat ship earth station. Issued FCC Safety Radiotelephony certtificate states that the vssel is equipped with MF and HF radios. Provide appropriate radio equipment of provide FCC authorization for use of satellite phone in lieu of the above equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel repaired SSB.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 February 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual alarm for anchor locker high level alarm not operable. Repair and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel deomonstrated proper operation of alarm.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. The bilge high level alarm in the fore peak was found with an improper splice. Properly splice conductor.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel provided proper butt connection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 February 2022
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have records of monthly portable fire extinguisher inspections. Provide record.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel conducted February and March checks and provided logs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022
Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. Vessel was unable to demonstrate relief of safety valve at set pressure. Demonstrate safety relief valve to satisfaction of the attending USCG marine inspector. Until resolved, vessel is prohibited from using installed pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2022
Resolved 23 March 2022
Resolution: Vessel bench tested valve and installed on tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2021
Resolved
Bilge systems must be fitted with a check valve in the bilge line. Bilge system found witout check valves. Provide check valves in bilge lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel installed check valves.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 April 2021
Resolved
Rail courses are required every four inches. Upper deck rails not fitted with courses. Provide courses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 30 April 2021
Resolution: Vessel provided rail courses at 4" intervals.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 April 2021
Resolved
VHF DSC radio must be provided with MMSI and GPS input. VHF installation found without MMSI and GPS. Provide ppoperly configured DSC VHF radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel proeprly provisioned radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021
Resolved
Ring life buoy grab lines deteriorated. Renew grab lines or replace ring buoy.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel provided new ring buoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 April 2021
Resolved
Records of EAP training for employees and supervisors not available. Provide training and documentation.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel provided EAP training and logged it.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 April 2021
Resolved
Significant rot found throughout lazarette. Remove rot to satisfaction of attending USCG Marine Inspector. Following verification of removal, treat wood. Areas of concern include but are not limited to: port side forward overhead in way of water tank vent, port water tank supports, decking supports forward/midships, longitudinal floor beams.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 30 April 2021
Resolution: Vessel repaired rotted areas.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 January 2020
Resolved
Provide ammeter for battery charging system in pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2020
Resolved 21 January 2020
Resolution: Vessel installed ammeter for battery charging circuit in the pilot house.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 January 2020
Resolved
Repair latch and gasket for port engine room ventilation closure and repair hole in starboard engine room ventilation passage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel repaired holed area in starboard ventilation and repaired latch and gasket in port ventilation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 January 2020
Resolved
Properly mount bilge high level float switch in lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel re-mounted switch.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 January 2020
Resolved
Provide single version of emergency procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel reviewed and consolidated emergency instructions.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 16 October 2019
Resolved
Matress must meet 46cfr1632 unless O/O can prove they were installed prior to 03/11/1996.
O/O shall change out matresses or provide a statement attesting to its compliant to old T.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 January 2020
Resolution: Vessel provided signed statement attesting that mattresses were installed prior to March 1996 and applied No-Burn fire retardent spray.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 October 2019
Resolved
Vessel shall have covered metal trash containers in all lounge areas.
Vessel had plastic trash containers in these spaces.
Vessel shall provide metal trash containers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2019
Resolution: Proper trash cans provided.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 October 2019
Resolved
Vessel shall have a P.A. system and a General alarm for overnight accommodations.
Vessel did not have adequate coverage of both systems.
Provide a speaker in the bunk room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2019
Resolution: PA system corrected.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 March 2018
Resolved
Renew expired FCC safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2018
Resolved 28 March 2018
Resolution: Certificate renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 March 2018
Resolved
Update first aid kit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 28 March 2018
Resolution: Kit updated.
Communications › Radio Communications › EPIRB
Issued 27 March 2018
Resolved
Renew EPIRB battery or register a new EPIRB with NOAA, Restriced to 03NM from shore.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 28 March 2018
Resolution: Owner registered a new EPIRB.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 March 2018
Resolved
Mark top of escape hatch.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Hatch marked.
Engineering › Pressure Vessel › Shell Plate
Issued 5 May 2017
Resolved
Hydro test P/V or replace.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 28 June 2017
Engineering › Bilge Water Management System › Strainer
Issued 26 April 2017
Resolved
Replace bilge pick-up in forward peak.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 26 April 2017
Resolution: Bilge pick-up replaced on the spot.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2017
Resolved
Dry bilges in bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilges dry.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 April 2017
Resolved
Secure overhead light in stbd forward stores room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 26 April 2017
Resolution: Light fixture secured on the spot.
Deck/Cargo › Holds/Tanks › Hatch
Issued 26 April 2017
Resolved
Install inspection port for visual access under water tanks in bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 28 June 2017
Engineering › Bilge Water Management System › Pump
Issued 26 April 2017
Resolved
Secure bilge pump in E/R and re-position to allow nearby valve to close properly.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilge pump secure and re-positioned.
Engineering › Bilge Water Management System › Hose
Issued 26 April 2017
Resolved
Replace damaged bilge pump hoses in E/R.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilge pump hoses replaced.
Engineering › Bilge Water Management System › Manifold
Issued 26 April 2017
Resolved
Replace PVC elbow with metallic at bilge manifold for bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Metallic elbow installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 April 2017
Resolved
Secure in place stbd sewage pump.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Sewage pump secure.
Lifesaving › Buoyant Apparatus › Capacity
Issued 18 April 2017
Resolved
Provide 24” USCG-approved orange ring buoy
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: 24" ring provided.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 April 2017
Resolved
Clean mfg data plate on pressure vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Data plate cleaned
Engineering › Compressed Air System (control) › Fitting
Issued 18 April 2017
Resolved
Clean and inspect, or replace, pipe fitting on bottom of pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Pipe fitting cleaned and inspected sat.
Documentation › Certificates/Documents › FCC SSL
Issued 18 April 2017
Resolved
Renew FCC SSL
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 27 March 2018
Resolution: Renewed.
Engineering › Steering Gear System › Rudder Stock
Issued 18 April 2017
Resolved
Renew port rudder packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Packing renewed and tested sat underway.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 March 2016
Resolved
Provide current U.S. Coast Pilot & Light List
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2016
Resolved
Provide most recent firefighting equipment servicing report.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 30 March 2016
Resolved
Install suitable storm rail or grab rail ro provide safe access to IBA.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Engineering › Steering Gear System › Rudder Stock
Issued 30 March 2016
Resolved
Adjust port rudder packing to stanch leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 March 2016
Resolved
Mount jct box for aft starboard compressor on bulkhead or stanchion well above bilge. Ensure jct box will close securely without duct tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 29 December 2011
Resolved
1. Exercise Fuel S/O valve. Relocate handle shut off pull cable so it doesn't fall into the space.
Due 29 January 2012
Resolved 2 January 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 29 December 2011
Resolved
2. Replace all E/R 12 V welding cable.
Due 29 January 2012
Resolved 2 January 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 December 2011
Resolved
3. Provide top cover for generator selector switch box.
Due 29 January 2012
Resolved 2 January 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 29 December 2011
Resolved
4. Secure loose wiring in galley.
Due 29 January 2012
Resolved 2 January 2012
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 January 2010
Resolved
PRIOR TO CARRYING OVERNIGHT PASSENGERS, REPLACE TWO SMOKE DETECTORS IN BERTHING.
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 20 January 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 January 2010
Resolved
REPLACE RING BUOY LINE (60').
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 January 2010
Resolved
Replace hydraulic steering hose between ram & directional valve (inboard hose).
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Documentation › Markings/Placards › Official Number (US)
Issued 19 January 2010
Resolved
Affix EPIRB registration decal to EPIRB.
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 January 2010
Resolved
Replace lamp cord with approved marine cable (power cable for soft drink dispenser).
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 19 January 2010
Resolved
Replace generator fuel supply line (hose).
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Documentation › Markings/Placards › Capacity Marking
Issued 19 January 2010
Resolved
Stencil maximum passenger capacity of upper deck (10).
Action required: 705 - Other - as specified
Due 19 February 2010
Resolved 23 February 2010
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 April 2009
Resolved
Make air receiver available for insp at next scheduled CG Insp
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 28 December 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 10 April 2007
Resolved
Provide valid radiotelephone certificate for SSB.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 16 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 April 2007
Resolved
Provide five additional L/J's. Crew and passenger are reduced to 37 until the L/Js are provided.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 April 2006
Resolved
Install nav light red/white/red for restrictive maneuverability during dive ops.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 9 May 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 21 April 2006
Resolved
Secure dryer and provide lint trap.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 26 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006
Resolved
Replace STBD gen set exhaust coolant hose.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 26 April 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 April 2006
Resolved
Label electrical breaker box in the E/R.
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 26 April 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 25 January 2005
Resolved
Clean vent screens and ducts for bunk room ventilation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Construction/Loadline › Structures › Deck Plating
Issued 25 January 2005
Resolved
Make cut in deck board to facilitate ball valve closure for starboard generator cooling water intake.
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 25 January 2005
Resolved
Renew B-II portable fire extinguisher for galley.
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2005
Resolved
Remove dead-end wiring in engine room.
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 25 January 2005
Resolved
Repair/replace exhaust vent for engine room on port side of deckhouse.
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 January 2005
Resolved
Properly mount hoses/piping for head flushwater system on forward bulkhead in engine room.
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 23 February 2005
Lifesaving › Buoyant Apparatus
Issued 27 April 2004
Resolved
Noted perimeter grab lines on 12 person and 6 person life floats located on top of pilot house were deteriorated. Required O/O to replace. Replacement commenced prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 27 April 2004
Resolved
Noted extensive flake rust on bottom of one of the required B-II portable fire extinguishers. Required O/O to replace. O/O already had a new extinguisher on order to replace. New extinguisher placed on vsl 4/29/04. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 29 April 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 April 2004
Resolved
Noted the closure device for the engine room ventilation supply duct would not close securely. O/O purchased and installed weatherstripping along perimeter of vent closure which allowed vent door to close tightly.
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Fire Fighting › Miscellaneous Items
Issued 27 April 2004
Resolved
Noted smoke detector on starboard side of berthing compartment did not operate when tested. O/O replaced prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2004
Resolved
Install req'd communications equipment IAW FCC regulations 47CFR80 for a Small Passenger Vessel with a operating route not to exceed 100 NM from the mainland shore. Vessel's route is restricted to not more than 20 nm from the mainland shore until the above item has been corrected. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 10 April 2007
Documentation › Certificates/Documents › FCC SSL
Issued 12 April 2004
Resolved
Update vessel FCC SSL to reflect new equipment installed to comply w/comms. equipment requirements for 100 nm from shore operational route. Vessel's route is restricted to not more than 20 nm from the mainland shore until the item has been corrected. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 10 April 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 April 2003
Resolved
Renew or replace ring buoy light.
Action required: 705 - Other - as specified
Due 29 May 2003
Resolved 29 May 2003
Resolution: Replaced ring buoy light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 April 2003
Resolved
Prove proper operation of the anchor light.
Action required: 705 - Other - as specified
Due 29 May 2003
Resolved 29 April 2003
Resolution: Proved proper operation of the anchor light.
Construction/Loadline › Hull › Hull Plating
Issued 23 May 2002
Resolved
Repair damaged area to stem and hull caused by recent allision with submerged object.
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 24 May 2002
Engineering › Bilge Water Management System
Issued 7 May 2002
Resolved
Prove proper operation of bilge high water alarm for lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 7 May 2002
Documentation › Safety/Response Plans/Programs
Issued 7 May 2002
Resolved
Provide proof of current entollment and annual MIS report for 2001 for company chemical testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2002
Resolved 7 May 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 May 2002
Resolved
Relocate discharge control actuator for engine room fixed fire suppression system in accordance with 46 CFR 181.410(b). LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 22 October 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 May 2002
Resolved
Post activation instructions for engine room fixed fire suppression system in accordance with 46 CFR 185.612.
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 22 October 2002
Electrical › Electric Supply System (service)
Issued 7 May 2002
Resolved
Provide covers for aft batteries in engine room. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 22 October 2002
Electrical › Electrical Distribution System (service)
Issued 7 May 2002
Resolved
Renew all "SO" electrical cable throughout vessel where the voltage exceeds 50 VAC. Item to be completed prior to receiving credit for next biennial hull exam. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 26 February 2003
Resolution: Renewed all "SO" eclectrical cable throughout the vessel where the voltage exceeded 50 VAC.
Engineering › Compressed Air System (control)
Issued 7 May 2002
Resolved
Prove proper operation of safety relief valve on air receiver in lazarette. Vessel is restricted from utilizing air receiver until corrected.
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 26 February 2003
Resolution: Proved proper operation of safety relief valve on the air receiver in lazarette.
Documentation › Certificates/Documents
Issued 7 May 2002
Resolved
Provide current copy of FCC safety radiotelephony certificate. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 22 October 2002
Documentation
Issued 10 May 2001
Resolved
Update FCC ststion license to include 406 EPIRB.
Condition: Unknown
Due 10 June 2001
Resolved 7 May 2002
Navigation
Issued 10 May 2001
Resolved
Renew the lens on the port and starboard running light.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Navigation
Issued 10 May 2001
Resolved
Renew or updtae the lightlist.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Electrical
Issued 25 August 2000
Resolved
SUBMIT PLANS TO REPLACE ALL NON-APPROVED ELECTRICAL WIRING IN THE VESSEL'S AC ELECTRICAL SYSTEM USING APPROVED WIRING.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Fire Fighting
Issued 25 August 2000
Resolved
SUBMIT PLANS TO INSTALL FIRE DETECTION SYSTEM FOR GALLEY GREASE EXTRACTION HOOD IAW MOC POLICY LETTER 4-98.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Navigation
Issued 11 February 2000
Resolved
As required by 46 CFR 54.01-5 Provide copy of manufactures plans for installed class II pressure vessel in way of lazarette.
Condition: Unknown
Due 11 February 2000
Resolved 11 February 2000
Fire Fighting
Issued 11 February 2000
Resolved
INSTALL GREASE EXTRACTION HOOD AS REQUIRED BY 46 CFR 181.400(D)/46CFR 181.425.
Condition: Unknown
Due 11 February 2000
Resolved 11 February 2000
Lifesaving
Issued 11 February 2000
Resolved
RENEW 1 CHILD PFD. VESSEL IS RESTRICTED TO OPERATING WITH NO MORE THAN 5 CHILDREN.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Lifesaving
Issued 11 February 2000
Resolved
RENEW PFD LIGHT ON 1 ADULT PFD.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Documentation
Issued 11 February 2000
Resolved
POST EAP INFORMATION.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Documentation
Issued 11 February 2000
Resolved
PROVIDE COPY OF LATEST MIS FORM OR LETTER STATING CONSORTIUM SUBMITTED ON COMPANY'S BEHALF.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Lifesaving
Issued 11 February 2000
Resolved
HAVE AND MAINTAIN ON BOARD URINE COLLECTION KITS PER 46 CFR 16.240/46CFR4.06
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Engineering
Issued 11 February 2000
Resolved
RENEW F/O HOSE FROM MANIFOLD TO F/O FILTER. USE A-I OR A-II STYLE APPROVEDHOSE.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Electrical
Issued 11 February 2000
Resolved
RENEW ALL SO ELECTRICAL CABLE THROUGHOUT VESSEL WHERE THE VOLTAGE EXCEEDS 50VAC.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 May 2002
Resolution: Cleared and reissued to be completed prior to credit for next hull exam.
Fire Fighting
Issued 11 February 2000
Resolved
REPAIR AS NEW STBD GENERATOR SHUTDOWN ON FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Electrical
Issued 11 February 2000
Resolved
INSTALL BACKING PLATE ON HOT WATER HEATER IN LAZARETTE.
Condition: Unknown
Due 11 March 2000
Resolved 22 February 2000
Construction/Loadline
Issued 10 February 1999
Resolved
RENEW ALL BILGE NON-METALLIC HOSE IN WAY OF ENGINEROOM USE USCG A-II OR B- I, B-II APPROVED HOSE.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Lifesaving
Issued 10 February 1999
Resolved
RENEW WEAK LINK ON LIFEFLOATS IN WAY OF CABIN TOP
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Lifesaving
Issued 10 February 1999
Resolved
MARK QTY OF ADULT PFD'S ON STORAGE MARKINGS IN WAY OF ACCOMODATION
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Lifesaving
Issued 10 February 1999
Resolved
ATTACH 70 FT LINE TO LIFERING BUOY AND INSTALL RETROREFLECTIVE ON RING BUOY
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Engineering
Issued 8 January 1999
Resolved
Repalce suction and return fuel lines with CG approved fuel lines and fittings for both generators.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Engineering
Issued 8 January 1999
Resolved
Replace raw water suction hose for both propulsion and generator engines from sea valve to suction side of strainers.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 8 January 1999
Resolved
Repair fwd stanchions port and stbd. side in engine room.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 January 1999
Resolved
Replace bowl guard on stbd generator racor fuel filter.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 January 1999
Resolved
Replace both generators supply and return fuel lines with CG approve hose and fittings.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Electrical
Issued 8 January 1999
Resolved
Remove portable temporary fan from engine room.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Fire Fighting
Issued 8 January 1999
Resolved
Have portable fire ext. stbd. side accomadation space recharged.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Electrical
Issued 8 January 1999
Resolved
Install cover over opening in electrical panel for dive air compressor.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 8 January 1999
Resolved
Conduct underway checkride in the prescence of attending marine inspector.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999
Resolved
Repair hand rail on port side leading from dive platform.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 January 1999
Resolved
Label fuel shut off valves.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 January 1999
Resolved
Tighten drive belt for raw water pump on port aux. generator.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 8 January 1999
Resolved
Clean to good wood and treat wood rot in engine room port side overhead under hot tub.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 8 January 1999
Resolved
Remove dry rot clean to good wood and treat bilge area stbd. side forward of battery boxes.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Engineering
Issued 8 January 1999
Resolved
Replace exhaust cooling hose on port-misd,u propulsion engine.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Construction/Loadline
Issued 8 January 1999
Resolved
Repair or replace forepeak bilge suction valve and prove operation.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Unknown
Issued 10 February 1998
Resolved
Replace the generator exhaust.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Unknown
Issued 10 February 1998
Resolved
Replace or repair all four life floats.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Navigation
Issued 18 February 1994
Resolved
PROVIDE & MAINTAIN ON VESSEL ALL CURRENT CHARTS, PUBS & COPY OF SUBCHAPTER "T" REGULATIONS IAW 46 CFR 185.20-35 FOR AREA OF OPERATION.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Engineering
Issued 18 February 1994
Resolved
PROVIDE PROPER BOND BETWEEN FUEL FILL & FUEL TANK.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Lifesaving
Issued 18 February 1994
Resolved
CONDUCT U/W EMERGENCY DRILLS WITH CG MARINE INSPECTOR IN ATTENDANCE NLT 18 MAR 94.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Electrical
Issued 18 February 1994
Resolved
REMOVE ELECTRICAL CABLE FROM RAW WATER PIPING IN WAY OF LAZARETTE & PROPERLY SECURE CABLE IAW 46 CFR 183.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Electrical
Issued 18 February 1994
Resolved
PROPERLY LABEL ALL PWR PNLS & DISTRIBITION PNLS.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Electrical
Issued 18 February 1994
Resolved
REMOVE WIRE NUTS & PROVIDE & INSTALL APPROVED WIRE CONNECTERS FOR ELECTRICAL WIRING IN WAY OF PORT PASSENGER BERTHING COMPT.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Electrical
Issued 18 February 1994
Resolved
REMOVE ALL UNUSED DEAD ENDED WIRE & PROPERLY SECURE ALL WIRE RUNS USING APPROVED WIRING METHODS IAW 46 CFR 183. PROVIDE & INSTALL PROPER TERMINAL STRIPS FOR BATTERY SWITCHES & REMOVE EXCESS WIRES FROM BTY TERMINALS TO PREVENT EXPLOSION/FIRE HAZARD.
Condition: Unknown
Due 18 March 1994
Resolved 25 May 1994
Navigation
Issued 13 February 1992
Resolved
BRING VESSEL'S CHARTS AND PUBLICATIONS INTO COMPLIANCE WITH 46 CFR 185.20- 25.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 13 February 1992
Resolved
PROVIDE STERN LIGHT WITH LENS, VESSEL IS NOT TO OPERATE UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Electrical
Issued 13 February 1992
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING IN BERTHING AREA STARBOARD SIDE.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Electrical
Issued 13 February 1992
Resolved
REMOVE WIRE NUTS THROUGHOUT THE VESSEL, MAKE PROPER SPLICES.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Electrical
Issued 13 February 1992
Resolved
PROPERLY BLOCK UNUSED OPENINGS IN CIRCUIT BREAKER BOXES IN ENGINE COMPARTMENT.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Documentation
Issued 13 February 1992
Resolved
PROVIDE VESSEL WITH VALID F.C.C. RADIO TELEPHONE CERTIFICATE, VESSEL IS NOTTO CARRY PASSENGERS FOR HIRE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 11 February 1991
Resolved
REMOVE SLOP FROM STEERING RAM TO YOKE CONNECTION BOLT.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Accommodation/Occupational Safety
Issued 11 February 1991
Resolved
RENEW TWO HOLED DIVE COMPRESSOR INTAKE HOSES IN LAZARETTE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Fire Fighting
Issued 11 February 1991
Resolved
REPLACE OR REPAIR BROKEN HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Fire Fighting
Issued 11 February 1991
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AND PROVIDE THIS OFFICE WITH SERVICE REPORT PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Accommodation/Occupational Safety
Issued 7 January 1991
Resolved
HOOK UP STARBOARD MARINE SANITATION DEVICE HOLDING TANK VENT HOSE.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Construction/Loadline
Issued 7 January 1991
Resolved
RENEW AND REALIGN STARBOARD MAIN ENGINE RAW WATER INTAKE AND STARBOARD GENERATOR RAW WATER INTAKE FLEXIBLE HOSES WHERE KINKED AND INSTALL WIRE WOUND TYPE.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Construction/Loadline
Issued 7 January 1991
Resolved
CAULK AREA OF DECK AROUND FILLS FOR FUEL TANK AND STBD FRESH WATER TANK._x001C_ GRIND AND TREAT ROT UNDER DECK AROUND THESE FILLS.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Construction/Loadline
Issued 7 January 1991
Resolved
FILL THE FOLLOWING HOLES IN TRANSVERSE BULKHEADS: (A) WIRE PENETRATION IN COLLISION BULKHEAD (B) PORT SIDE OF FORWARD LAZARETTE BULKHEAD (C) TRANSOMWHERE FLOOD LIGHT WIRE PENETRATES.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Fire Fighting
Issued 7 January 1991
Resolved
INSTALL FLAME SCREEN AT FUEL TANK VENT.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Electrical
Issued 7 January 1991
Resolved
REPLACE ALL WIRE NUTS WITH CRIMP ON TYPE FOR ELECTRICAL WIRING.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Lifesaving
Issued 22 February 1990
Resolved
REPAINT BOTH BRIDGE LIFE FLOATS.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
PROVIDE PROPER SUPPORT FOR POTENTIOMETER FOR VOLTAGE REGULATOR.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
PROVIDE COVER FOR JACUZZI SUB-PANEL; INCLUDE CIRCUIT BREAKER.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
REMOVE OR RELOCATE 32-VOLT LIGHT FIXTURE, STARBOARD SIDE IN WAY OF ENGINE- ROOM VENTILATION.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
PROVIDE COVER FOR OPENING IN SECONDARY CIRCUIT BREAKER PANEL FOR AIR COMPRESSOR.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Construction/Loadline
Issued 22 February 1990
Resolved
PROVIDE CAPTURE CHAIN FOR POREPEAK WATERTIGHT HATCH.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
REMOVE ALL WIRE NUTS FROM VESSEL AND MAKE PROPER SPLICES/CONNECTIONS.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Fire Fighting
Issued 22 February 1990
Resolved
PROVIDE HOLDER FOR BRIDGE B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 8 January 1990
Resolved
PROVIDE PROPER METAL SUPPORTS FOR WIRING EVERY 18 INCHES ON HORIZONTAL AND 24 INCHES ON VERTICAL RUNS.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Construction/Loadline
Issued 8 January 1990
Resolved
PLUG HOLE IN AFT ENGINEROOM BULKHEAD FOR CABLE PENETRATION.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Construction/Loadline
Issued 8 January 1990
Resolved
REPAIR CONDENSER WATER DISCHARGE LINE AT STBD EXHAUST PORT.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Engineering
Issued 8 January 1990
Resolved
FREE-UP OR REPLACE BILGE SUCTION VALVE AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Construction/Loadline
Issued 8 January 1990
Resolved
REPAIR BR0KEN WINDOW IN STBD SIDE OF PASSENGER LOUNGE.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Construction/Loadline
Issued 8 January 1990
Resolved
REPAIR IMPROPERLY PLUMBED STBD MAIN ENGINE BLOW BY DISCHARGE HOSE TO THRU HULL.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Accommodation/Occupational Safety
Issued 8 January 1990
Resolved
PROVIDE PLANS FOR NEW ENGINE ROOM VENTILATION SYSTEM TO INCLUDE AT LEAST ONE VENT REACHING NEAR THE BOTTOM OF THE BILGES.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 8 January 1990
Resolved
INSTALL SPLASH GUARD UNDER DIESEL RETURN CONNECTS ABOVE FUSE BOX ON FORWARDENGINEROOM BULKHEAD.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 8 January 1990
Resolved
PROVIDE COVERS FOR: 12 VOLT FUSE BOX, SWITCH TO FAN MOTOR ON VENTS, 220 VOLT BREAKER PANEL.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Navigation
Issued 8 January 1990
Resolved
PROPERLY MOUNT BAIT TANK PUMP ON STBD AFT SIDE OF ENGINEROOM.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Fire Fighting
Issued 24 February 1989
Resolved
PROVIDE A FLAME SCREEN AT FUEL VENT STARBOARD SIDE.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Lifesaving
Issued 24 February 1989
Resolved
REPLACE OUTDATED EPIRB BATTERY.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Fire Fighting
Issued 24 February 1989
Resolved
REPLACE TWO B-I WITH TWO B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Engineering
Issued 31 March 1988
Resolved
PROVIDE AND PROVE OPERATION OF STBD MAIN ENGINE.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Electrical
Issued 11 February 1988
Resolved
PROVIDE MACHINERY GUARD FOR STBD GENERATOR AND REPLACE 2 WIRE-NUT TYPE CONNECTORS WITH CRIMP-ON TYPE.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Lifesaving
Issued 11 February 1988
Resolved
RESTENCIL RING BUOY.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Lifesaving
Issued 11 February 1988
Resolved
STENCIL AND TIE DOWN PADDLES TO TOP LIFE FLOAT.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Engineering
Issued 20 February 1986
Resolved
REPAIR PORT EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Engineering
Issued 20 February 1986
Resolved
REPAIR FUEL FILTERS ON MAIN ENGINES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
TWO BLOCK BATTERY IN PILOTHOUSE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
INSTALL LIGHT COVER IN PILOTHOUSE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
INSTALL NEW PANEL DOOR ON 110 VOLT BREAKER BOX.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Accommodation/Occupational Safety
Issued 20 February 1986
Resolved
SUBMIT AIR COMPRESSOR INSTALLATION TO THIS OFFICE FOR APPROVAL.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 November 1984
Resolved
PROVIDE INFO ON NEW COMPRESSOR AND WIRING, INCLUDING CURRENT LOAD AND OVER CURRENT PROTECTION.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Construction/Loadline
Issued 20 November 1984
Resolved
REMOVE SWIM STEP CABLE FROM TRANSOM PENETRATION AND FILL HOLE. ADD BACKING BLOCK.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Electrical
Issued 20 November 1984
Resolved
REMOVE ALL OPEN END ELECTRICAL WIRES IN LAZARETTE.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Lifesaving
Issued 20 November 1984
Resolved
PROVIDE 13 ADULT AND 1 CHILD PFD'S. VESSEL MAY NOT CARRY MORE THAN 36 TOTAL PERSONS.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984
Construction/Loadline
Issued 20 November 1984
Resolved
CROP OUT AND REPLACE BROKEN OVERHEAD BEAM IN LAZARETTE.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984