PEACE is a 1972 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2016, most recently in May 2025, along with 81 deficiencies, 2 operational controls, 1 with no removal date recorded and 10 casualty investigations between 2004 and 2022.

Records from 2004 to 2025. Most recent: inspection, 29 May 2025.

Built
1972
Last inspected
29 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2025
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBF3649
Flag
UNITED STATES
Maury page id
psix-47196

Documentation record

Registered dimensions (L × B × D)60.4 ft × 21.9 ft × 7.6 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRUSSEL A IZOR · VENICE, CA, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portVENTURA, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

31 inspections, each with its date, unit and type; 81 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 10 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

29 May 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8135388
9 January 2025 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8060046
15 October 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8016718
12 June 2024 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7933519
8 May 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7907612
11 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7824116
11 November 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7824122
7 September 2023 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7787136
2 May 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7625974
31 March 2023 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7631911
9 February 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7635162
2 February 2023 Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7625972
28 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613957
8 November 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7591720
12 September 2022 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7557008
19 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7482296
3 February 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7368749
17 September 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7314847
30 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7256055
5 April 2021 Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7165151
17 December 2019 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6875501
16 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6817096
12 July 2019 Damage Survey · Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6747186
18 April 2019 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6659822
18 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6665642
27 March 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6358912
26 April 2017 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127818
18 April 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6127667
13 September 2016 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6000042
31 July 2016 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5959980
30 March 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5843298

Deficiency record · 81

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 May 2025 Resolved
A system protecting a manned space must be fitted with an approved time delay and alarm arranged to require the alarm to sound for at least 20 seconds or the time necessary to escape from the space, whichever is greater, before the agent is released into the space. Alarms must be conspicuously and centrally located. The alarm must be powered by the extinguishing agent. Vessel's fixed fire shutdown for all four engines was inconsistent during testing. Provide fire service technician report attesting to system service and testing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2025
Resolution: Relays replaced and fire service testing and report received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2025 Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring Buoy's grab lines are UV damaged. Replace ring life buoy and life line.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 June 2025
Resolution: Vessel replaced ring buoy and life line.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 29 May 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Safetyradiotelephony cert was expired. Get new insepction and certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
Resolution: Beacon completed repairs and completed inspection. Issued 10 June 2025.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First Aid kit does not meet ISO 18813:2006 (4.12) or equivalent. Provide first aid kit as per ISO Standard 18813:2006 or equivalent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 June 2025
Resolution: Vessel provided first aid kit contents list and ISO equivalent contents.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 29 May 2025 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan.(b) Each garbage management plan under paragraph (a) of this section must be in writing and—(1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77;(2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and(3) Designate the person who is in charge of carrying out the plan. Provide garbage management plan to inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
Resolution: Garbage management plan provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and and systems, including the following:(a) Inspection of of all cable as far as practicable without undue disturbance of the cable or electrical apparatus; Accommodation lighting junction boxes are missing cable glands and over junction box limit. Provide line diagram of vessel's electrical distribution for the accommodation bunk room to verify circuit design and overcurrent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 23 June 2025
Resolution: Vessel is completing drawings and MI and vessel will revisted upon completion.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designate member of the crew. Vessel added the monthly fire inspections into the underway checklist.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 May 2025
Resolution: Vessel added to captain's attestation checklist.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Vessel's operating station crew bunks had undocuemented 12 vdc terminals supplying fans and usb outlets. Vessel removed power supply and disconnected all wiring from service.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 May 2025
Resolution: Vessel removed operating station crew bunk VDC exposed terminals and wiring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2025 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel is missing emergency radio broadcast placard. Create and post placard IAW 46 CG 184.510 Recommended Emergency Broadcast Instruction to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
Resolution: Broadcast placard posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected smoke detectors in the galley and lazarette did not activate while testing the machinery space detector. Repair smoke detectors and provide test to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Verified galley and lazarette interconnected function.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:(i) Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Lazarette fire extinguisher service date was Feb 2023 and beyond annual NFPA servicing requirement. Provide valid servicing record to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Serviced by IFS on 8May24.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2024 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Four life jacket lights did not activate upon testing. Provide valid test of life jacket lights to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: (4) lifejackets lights were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2024 Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Corrosion-resistant nozzle onboard vessel was leaking and not functioning as designed. Provide replacement corrosion-resistant nozzle for required fire hose to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Hose replaced and all (3) nozzles.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 8 May 2024 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. Vessel master could not provide proof of chemical testing consortium enrollment. Provide valid chemical testing enrollment to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 4 June 2024
Resolution: Vessel master onboard during inspection is now enrolled in PEACE consortium.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel had several combustible waste receptacles onboard. Remove all combustible waste receptacles and replace with non-combustible type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 4 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 May 2024 Resolved
A Certificate of Documentation is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. COD was expired onboard the vessel. Provide valid COD to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 June 2024
Resolution: Vessel provided photo evidence of valid COD.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2024 Resolved
The Rules concerning shapes shall be complied with by day. Vessel is required to carry shapes for signaling purposes for restricted in ability to maneuver (ball, diamond, ball) and vessel not under command (ball, ball). Provide day shapes to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 June 2024
Resolution: Vessel provided photo evidence of day shapes.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 May 2024 Resolved
The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;(b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and(c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel could not provide any previous test records for the required EPRIB monthly test. Vessel master provided new inspection log and performed monthly inspection on site. Deficiency rectified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel conducted EPIRB test on site and recorded in montly log.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 May 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the by the owner, operator, person-in-charge, or a designate member of the crew. Vessel could not provide any record of required NFPA monthly portable fire extinguisher inspections. Vessel master did provide new monthly log and performed and recorded the inspection on site. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel completed monthly inspection on site. Found one extinguisher in the lazarette service expired. Vessel logged in monthly inspection log.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 May 2024 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drills. Vessel could not provide any logs or proof of past completion of fire drills. Fire drill was preformed for machinery space during annual inspection. Master accurately logged the event. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel updated drill log with all three drills completed for annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 May 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Vessel could not provide logs or proof of past completion of MOB or abandon ship drills. MOB and abandon ship drills were conducted during annual inspection. Master accurately logged the event. Deficiency rectified on site.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2024
Resolution: Vessel completed all three drills during annual inspection. Master logged all drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2023 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. The fixed fire suppression system did not shut down the engines or generator in the engine space upon activation of the pressure sensor. Engine space power ventilation is designed to be shut down upon generator shut down. Prior to vessel departure, demonstrate proper operation of engine and ventialtion shut downs upon activation of the fixed fire suppression system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Vessel replaced pressure switch and relay assembly and demonstrated proper operation.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB hydrostatic release was found to be two years over expiration date. Provide current hydrostatic release prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2023
Resolution: Vessel provided new EPIRB hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's anchor light was not functioning. Provide functioning anchor light prior to 16MAY23.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 25 May 2023
Resolution: Vessel installed new anchor light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit analgesic medications were found expired. Provide first aid kit meeting ISO 18813:2006(E).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Vessel provided a new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Provide accurate life jacket location markings of required size.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Vessel marked life jacket locations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. Two dead end cables found under pilothouse console. Remove cables or terminate ends in accordance with 46 CFR 183.320.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 25 May 2023
Resolution: Cable was found to be speaker cable which will be used by vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 May 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Vessel was unable to provide a current NOAA EPIRB registration. Provide current registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2023
Resolved 3 May 2023
Resolution: Vessel renewed registration and provided new registration documentation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 March 2023 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Lower bunk rooms are not fitted with emergency lighting. Provide emergency lighting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel provided emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2023 Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (i) Bulwarks; (ii) Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or (iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Bow gate was found broken off. Replace gate or provide sufficient rail courses.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel repaired and re-installed bow gate.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 March 2023 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. During inspection excessive decay was found in the port side of the engine space, specifically along horizontal hull stiffeners, in way of the deck sink drain penetration and in way of the forward end of the outboard longitudinal deck stiffener. Remove rot to good wood and treat remaining wood.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 12 June 2023
Resolution: Vessel removed rot and treated with Smiths and West System.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2023 Resolved
Suitable storm rails or hand grabs must be installed where necessary in passageways, at deckhouse sides, and at ladders and hatches. The starboard side ladder rail was loose on the external ladder from the main deck to the upper deck. Repair rail.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel repaired rail.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. A wood screw was accidently driven into a 100 Amp circuit cable running through the forward bunk room space. Replace cable in kind or provide plans for modification.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Vessel repaired damaged conduit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023 Resolved
All cable and wire must not be installed with sharp bends. Cable installations throughout vessel were found installed with sharp bends. Remove bends.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel removed sharp bends.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Terminal blocks were found throughout vessel with no protective enclosure. Provide enclosures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel provide protection from shock on terminal blocks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. In-line fuses for watch alarm system were found to be an improper type. Provide approved cartridge type fuses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 2 February 2023
Resolution: Vessel switched fuses to an approved type.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2023 Resolved
Each circuit breaker must meet UL 489 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant, and be of the manually reset type designed for: (1) Inverse time delay; (2) Instantaneous short circuit protection; and (3) Switching duty if the breaker is used as a switch. Vessel was unable to demonstrate compliance of newly installed breaker for roving watch alarm system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2023
Resolved 31 March 2023
Resolution: Vessel removed non-UL listed breaker.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not install an interconnected fire detection system by 27DEC2022. Vessel is restricted to a LIMITED COASTWISE route until it's compliance with the interconnected fire detection requirements of 46 CFR 181.405 have been verified by a USCG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Vessel installed interconnected fire detection and a rving watch alarm system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 August 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Vessel replaced galley stove/oven, chest freezer and added a dishwasher. Provide data plates showing change in amperage draw for affected circuits.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 22 August 2022
Resolution: Vessel provided model numbers.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 August 2022 Resolved
An individual may not be engaged or employed, including self-employment, on a vessel in a position as master, operator, or person in charge for which a credential is required by law or regulation unless all crewmembers covered by this section are subject to the random testing requirements of this section. Vessel crew included two mariners who were part of a different marine employer's program. Provide documentation that shows marine employer's notification in case of positive random drug testing results.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 27 August 2022
Resolution: Vessel provided current covered crew list showing assigned crew.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 3 February 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must be equipped as required in 47 CFR 80.905(a)(3). Vessel does not have a functioning DSC-MF, DSC-SSB or GMDSS-approved Inmarsat ship earth station. Issued FCC Safety Radiotelephony certtificate states that the vssel is equipped with MF and HF radios. Provide appropriate radio equipment of provide FCC authorization for use of satellite phone in lieu of the above equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel repaired SSB.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 February 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual alarm for anchor locker high level alarm not operable. Repair and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel deomonstrated proper operation of alarm.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2022 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. The bilge high level alarm in the fore peak was found with an improper splice. Properly splice conductor.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel provided proper butt connection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 February 2022 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have records of monthly portable fire extinguisher inspections. Provide record.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 18 March 2022
Resolution: Vessel conducted February and March checks and provided logs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2022 Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. Vessel was unable to demonstrate relief of safety valve at set pressure. Demonstrate safety relief valve to satisfaction of the attending USCG marine inspector. Until resolved, vessel is prohibited from using installed pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2022
Resolved 23 March 2022
Resolution: Vessel bench tested valve and installed on tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2021 Resolved
Bilge systems must be fitted with a check valve in the bilge line. Bilge system found witout check valves. Provide check valves in bilge lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel installed check valves.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 April 2021 Resolved
Rail courses are required every four inches. Upper deck rails not fitted with courses. Provide courses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 30 April 2021
Resolution: Vessel provided rail courses at 4" intervals.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 April 2021 Resolved
VHF DSC radio must be provided with MMSI and GPS input. VHF installation found without MMSI and GPS. Provide ppoperly configured DSC VHF radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel proeprly provisioned radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021 Resolved
Ring life buoy grab lines deteriorated. Renew grab lines or replace ring buoy.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel provided new ring buoy.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 April 2021 Resolved
Records of EAP training for employees and supervisors not available. Provide training and documentation.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel provided EAP training and logged it.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 April 2021 Resolved
Significant rot found throughout lazarette. Remove rot to satisfaction of attending USCG Marine Inspector. Following verification of removal, treat wood. Areas of concern include but are not limited to: port side forward overhead in way of water tank vent, port water tank supports, decking supports forward/midships, longitudinal floor beams.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 30 April 2021
Resolution: Vessel repaired rotted areas.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 January 2020 Resolved
Provide ammeter for battery charging system in pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2020
Resolved 21 January 2020
Resolution: Vessel installed ammeter for battery charging circuit in the pilot house.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 January 2020 Resolved
Repair latch and gasket for port engine room ventilation closure and repair hole in starboard engine room ventilation passage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel repaired holed area in starboard ventilation and repaired latch and gasket in port ventilation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 January 2020 Resolved
Properly mount bilge high level float switch in lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel re-mounted switch.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 January 2020 Resolved
Provide single version of emergency procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 21 January 2020
Resolution: Vessel reviewed and consolidated emergency instructions.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 16 October 2019 Resolved
Matress must meet 46cfr1632 unless O/O can prove they were installed prior to 03/11/1996. O/O shall change out matresses or provide a statement attesting to its compliant to old T.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 January 2020
Resolution: Vessel provided signed statement attesting that mattresses were installed prior to March 1996 and applied No-Burn fire retardent spray.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 October 2019 Resolved
Vessel shall have covered metal trash containers in all lounge areas. Vessel had plastic trash containers in these spaces. Vessel shall provide metal trash containers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2019
Resolution: Proper trash cans provided.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 October 2019 Resolved
Vessel shall have a P.A. system and a General alarm for overnight accommodations. Vessel did not have adequate coverage of both systems. Provide a speaker in the bunk room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2019
Resolution: PA system corrected.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 March 2018 Resolved
Renew expired FCC safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2018
Resolved 28 March 2018
Resolution: Certificate renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 March 2018 Resolved
Update first aid kit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 28 March 2018
Resolution: Kit updated.
Communications › Radio Communications › EPIRB
Issued 27 March 2018 Resolved
Renew EPIRB battery or register a new EPIRB with NOAA, Restriced to 03NM from shore.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 28 March 2018
Resolution: Owner registered a new EPIRB.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 March 2018 Resolved
Mark top of escape hatch.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Hatch marked.
Engineering › Pressure Vessel › Shell Plate
Issued 5 May 2017 Resolved
Hydro test P/V or replace.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 28 June 2017
Engineering › Bilge Water Management System › Strainer
Issued 26 April 2017 Resolved
Replace bilge pick-up in forward peak.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 26 April 2017
Resolution: Bilge pick-up replaced on the spot.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 April 2017 Resolved
Dry bilges in bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilges dry.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 April 2017 Resolved
Secure overhead light in stbd forward stores room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 26 April 2017
Resolution: Light fixture secured on the spot.
Deck/Cargo › Holds/Tanks › Hatch
Issued 26 April 2017 Resolved
Install inspection port for visual access under water tanks in bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 28 June 2017
Engineering › Bilge Water Management System › Pump
Issued 26 April 2017 Resolved
Secure bilge pump in E/R and re-position to allow nearby valve to close properly.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilge pump secure and re-positioned.
Engineering › Bilge Water Management System › Hose
Issued 26 April 2017 Resolved
Replace damaged bilge pump hoses in E/R.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Bilge pump hoses replaced.
Engineering › Bilge Water Management System › Manifold
Issued 26 April 2017 Resolved
Replace PVC elbow with metallic at bilge manifold for bunk room.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Metallic elbow installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 April 2017 Resolved
Secure in place stbd sewage pump.
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 5 May 2017
Resolution: Sewage pump secure.
Lifesaving › Buoyant Apparatus › Capacity
Issued 18 April 2017 Resolved
Provide 24” USCG-approved orange ring buoy
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: 24" ring provided.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 April 2017 Resolved
Clean mfg data plate on pressure vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Data plate cleaned
Engineering › Compressed Air System (control) › Fitting
Issued 18 April 2017 Resolved
Clean and inspect, or replace, pipe fitting on bottom of pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Pipe fitting cleaned and inspected sat.
Documentation › Certificates/Documents › FCC SSL
Issued 18 April 2017 Resolved
Renew FCC SSL
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 27 March 2018
Resolution: Renewed.
Engineering › Steering Gear System › Rudder Stock
Issued 18 April 2017 Resolved
Renew port rudder packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 5 May 2017
Resolution: Packing renewed and tested sat underway.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 March 2016 Resolved
Provide current U.S. Coast Pilot & Light List
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2016 Resolved
Provide most recent firefighting equipment servicing report.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 30 March 2016 Resolved
Install suitable storm rail or grab rail ro provide safe access to IBA.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Engineering › Steering Gear System › Rudder Stock
Issued 30 March 2016 Resolved
Adjust port rudder packing to stanch leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 March 2016 Resolved
Mount jct box for aft starboard compressor on bulkhead or stanchion well above bilge. Ensure jct box will close securely without duct tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016

Casualty record · 10

5 May 2004Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 2060228
10 July 2006Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 2 dead · activity 2709873
27 September 2006Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 2789893
20 September 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3331787
7 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4109531
9 June 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4340725
19 February 2013Routine · role: Involved in a Marine Casualty · activity 4535680
22 August 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4965569
13 September 2016Routine · role: Involved in a Marine Casualty · activity 6000042
8 November 2022Routine · role: Subject of Search and Rescue · serious marine incident, as classified · 1 dead · activity 7591720
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.