MILLENNIUM

MILLENNIUM is a 1998 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in June 2026, along with 40 deficiencies — 1 with no resolution recorded —, 1 operational control and 9 casualty investigations between 2001 and 2016.

Records from 2001 to 2026. Most recent: inspection, 23 June 2026.

Built
1998
Last inspected
23 June 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG2854
472007
Flag
UNITED STATES
Maury page id
psix-472007

Documentation record

Registered dimensions (L × B × D)110.0 ft × 32.6 ft × 9.8 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)110.0 ft × 32.6 ft × 9.8 ft
ITC tonnagegross 312 / net 123
BuilderDUCLOS CORP · SOMERSET, MA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portQUONSET POINT, RI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
123 - Convention (Subpart B), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
312 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

23 June 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8412035
19 June 2025 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8163344
9 July 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7954005
23 April 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7900101
12 October 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7807385
21 July 2023 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7744525
23 June 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7723579
14 June 2023 Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7715270
15 May 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7688890
24 August 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7295237
24 November 2020 Internal Structural Exam · Drydock Exam · Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7100683
25 June 2020 Examination of Repairs · Load Line/Change of Employment · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7017302
14 May 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6953562
13 February 2020 DAPI Audit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6920737
6 March 2019 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6637644
1 March 2019 Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6634202
29 November 2018 Examination of Repairs · Plan Review (Other than "T")
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6591118
5 November 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6572826
27 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6524146
17 July 2018 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6482588
9 February 2018 Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6353566
26 September 2017 Load Line/Change of Employment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6275298
7 August 2017 Load Line/Change of Employment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6237350
5 July 2017 Load Line/Change of Employment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6198239
26 June 2017 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6187523
14 April 2017 DAPI Audit · Load Line/Change of Employment · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6117512
5 October 2016 Load Line/Change of Employment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6012709
11 May 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5876484
27 April 2016 MTSA/ISPS Verification · Load Line/Change of Employment · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5863558
19 January 2016 Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5863653

Deficiency record · 40

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2026 No resolution recorded
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. After reviewing records, MIs observed vessel's last annual inspection was conducted in April 2024. Vessel's COI has lapsed. COI Renewal Inspection must be conducted prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2023 Resolved
All micro processor or computer based system must meet part 62 in subchapter F and operational testing of machinery essential to the routine operation must be tested at each COI inspection; approved DVTP must be conducted once every 5 years at the COI inspection or for cause as needed, must complete DVTP prior to NTZ/COI inspection certification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2023
Resolution: Completed DVTP with manufacture rep and vessel crew.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 July 2023 Resolved
Vessel's fire detection system has a trouble alarm showing; this must be investigated and repaired to original type approval of the system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2023
Resolution: Part finally recieved and installed, all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2023 Resolved
Vessel's FCC documentation has incorrect call sign, must receive new documents from FCC with correct call sign.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2023 Resolved
Spare breakers on the bridge were energized, must properly identify all breakers or secure spare as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2023 Resolved
Fire extinguisher on the 2nd deck IWO snack bar does not have a bracket, must put correct bracket into place.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2023 Resolved
Vessel does not have enough fire extinguishers on the main deck as per NVIC 9-97 due to it being designated a 5A space; must add 3 A-II fire extinguishers to the main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2023 Resolved
The vessel updated the bow area between hulls to accommodate the Seastreak landings, must update the GA and fire control plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 August 2023
Resolution: Received plans.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 21 July 2023 Resolved
Vessels type III MSD tank has a temporary patch on the aft plate; this must be properly repaired at the next Dry-Dock June 2025.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: MSD tank was repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 June 2021 Resolved
Vessel must undergo an annual inspection within three months before of after each anniversary date. Anniversary date 01MAR2021, vessel overdue. Request updated route for SECSENE and complete annual inspection within 30 days.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 8 August 2023
Resolution: Vessel completed a COI Inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Provide causative analysis explaining the nature of the crack. Provide repair proposal for approval and execute satisfactory repair proposal for port jet room crack in metal adjacent the overhead hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2021
Resolution: Repaired to the satisfaction of the [name withheld] number 7100683
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 27 July 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Provide and execute a permanent repair proposal for the port and starboard sewage tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2021
Resolution: Repaired to the satisfaction of the attending [name withheld] 7100683.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020 Resolved
Exhaust gas must not leak from the piping or any connections. Repair exhaust gas leak in the port jet room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2021
Resolution: Repaired to the satisfaction of the [name withheld] number 7100683
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2020 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place in the space where the extinguishing agent cylinders are stored. Location of stored CO2 (port and starboard CO2 voids) did not have operation instructions posted. Post proper instructions within 7 days. 46 CFR 122.612(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2020
Resolved 22 May 2020
Resolution: Vessel rep provided photos of posted instructions.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 May 2020 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. At the base of access ladder to starboard engine room, there is large portion of shaft that is not suitably protected against personnel injury. Install proper guard over exposed shaft. 46 CFR 116.960
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2020
Resolved 17 July 2020
Resolution: Rep provided photo of installed guard.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 14 May 2020 Resolved
A vessel must comply with the applicale design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. Port side containment for fuel fill was missing mechanical plug for containment. 46 CFR 121.702
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2020
Resolved 14 May 2020
Resolution: Plug replaced during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 March 2019 Resolved
Each survival craft must be stowed in a way that permits manual release from its securing arrangements. Two 100 person inflatable buoyant apparatus are secured on brackets at the uppermost deck without means of manual release from its securing location. Each device is too heavy for crew to move to launching door on either side of the vessel. Vessel to be restricted to operations no greater than 1nm from shore until suitable manual release of all survival craft can be achieved to the satisfaction of the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2019
Resolved 28 January 2020
Resolution: Operator submitted photos showing new locations for the additional 50 person IBA's to mitigate the need for the IBA which are too heavy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 March 2019 Resolved
Piping used in a vital system must meet 46CFR 56.60.Nonmetallic flexible hose used in vital systems must be in accordance with SAE J1942. Four flex hoses in service for each main engine reduction gear cooling lines do not meet SAE J1942 standards. Replace reduction gear cooling line flex hoses for each main engine to meet standards in accordance with 46CFR 56.60.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 13 March 2021
Resolution: Cleared to the satisfaction of the [name withheld] number 7100683
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 March 2019 Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel in accordance with the terms of the Certificate of the Inspection. Crack witnessed on doubler plate on starboard bridgewing. Vessel must determine extent of damage and make permanent repair to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 28 January 2020
Resolution: Operator submitted photos of weld repair of doubler plate on deck.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: Call Sign from expired FCC License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 19 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2018 Resolved
Port pull station in salon broken zone 1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2018
Resolved 31 July 2018
Resolution: New pull station installed, tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 July 2018 Resolved
Fire panel ER card fault.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 August 2018
Resolved 6 August 2018
Resolution: New card installed / test sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 12 February 2018 Resolved
C/R 2' section of discharge exhaust pipe as original located in S/S jet room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2018
Resolution: C/R 2' section to good metal, inserted new flange connection on both ends of exhuast pipe section. All sat
Construction/Loadline › Structures › Deck Plating
Issued 12 February 2018 Resolved
C/R P & S side dech plate above jet room due to cracking.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2018
Resolution: C/R P and S side with inserts as original. Port side approximate 24"X30" insert, hose tested all sat. Starboard side approximate 15"X24" insert, hose tested all sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 February 2018 Resolved
S/S #3 void space, inset causing 03 longitudnal frames to distort and welds are cracked, re-weld all marked sections.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2018
Resolution: Re-welded all areas of concern, all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 February 2018 Resolved
02 tabs located on aft deck for lifeline attachments are wasted, replace and weld in as original.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2018
Resolution: Replaced tabs in kind, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 26 September 2017 Resolved
Inset on fwd stbd side quarter, caused two side shell longs to bend and welds to crack. Both port and stbd jet rooms have substantial pitting on all structures including plating, longs and transverses. Both items are to be addressed during next DD/ISE per issued COI by April, 2018.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 19 April 2018
Resolution: Work Completed, all sat.
Engineering › Reduction Gearing/Clutches › Bearing
Issued 26 June 2017 Resolved
Bearing failure in #4 transmission.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 7 August 2017
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 25 April 2017 Resolved
Low lube oil pressure alarm not functioning for the #3 MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 27 April 2017
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 14 April 2017 Resolved
Galley had a rubber trash can. Replace with metalic trash can.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 25 April 2017
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 14 April 2017 Resolved
Prove proper installation and servicing of IBAs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 25 April 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 April 2017 Resolved
Replace lanyard for light to lifering on the second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 25 April 2017
Communications › Radio Communications › EPIRB
Issued 14 April 2017 Resolved
EPIRB out for servicing. Prove proper installation and servicing of EPIRB.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 25 April 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2017 Resolved
1st aid kit missing instructions and inventory list.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 25 April 2017
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 April 2017 Resolved
Missing logs for testing of EPIRB. Provide a log for the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 25 April 2017
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 May 2016 Resolved
Repair low oil pressure alarms on #2 and #3 main engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 5 May 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 May 2016 Resolved
Repair announciator on #4 main engine alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 5 May 2016
Construction/Loadline › Structures › Door
Issued 2 May 2016 Resolved
Repair aft door latches so doors will secure properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 5 May 2016
Communications › Radio Communications › Cellular Telephone Capability
Issued 2 May 2016 Resolved
Provide Satalite phone and test as a condition of the SOLAS Exemption Certificate.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 5 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2016 Resolved
Provide ammonia inhalents and iodine applicators for 1st aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2016
Resolved 5 May 2016

Casualty record · 9

19 May 2001Routine · role: Involved in a Marine Casualty · 1 injured · activity 96320
9 January 2004Routine · role: Involved in a Marine Casualty · activity 1981775
15 January 2004Routine · role: Involved in a Marine Casualty · activity 2001264
22 January 2004Routine · role: Involved in a Marine Casualty · activity 1991301
2 March 2005Routine · role: Involved in a Marine Casualty · activity 2315300
11 July 2009Routine · role: Involved in a Marine Casualty · activity 3533004
11 August 2011Routine · role: Involved in a Marine Casualty · activity 4192624
17 June 2013Routine · role: Involved in a Marine Casualty · activity 4637705
11 May 2016Routine · role: Involved in a Marine Casualty · activity 5876484
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MILLENIUM (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.