Records from 1998 to 2018. Most recent: inspection, 7 August 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
7 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6503239
22 February 2017
MTSA Verification · ACP Periodic Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6092887
14 September 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6000919
5 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5870062
30 March 2016
ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5843981
6 March 2016
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5870339
6 October 2014
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4998271
4 June 2012
MARPOL Annex I Examination · ACP Annual Oversight · MARPOL Annex V Examination · MTSA/ISPS Verification · DAPI Audit
Physical examination · Activities Europe · Activity 4326637
23 July 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3609859
18 June 2008
Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 3225795
6 September 2007
Annual Inspection
Physical examination · Activities Europe · Activity 2955071
17 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751245
28 May 2006
Internal Structural Exam · Annual Inspection · Hull Examination · ACP Annual Oversight
Physical examination · Activities Europe · Activity 2632784
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501636
14 August 2005
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2443893
3 June 2005
Deficiency Check
Physical examination · Activities Europe · Activity 2377694
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293967
14 February 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2291913
20 January 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2277714
10 September 2004
Re-Inspection
Physical examination · Activities Europe · Activity 2181754
21 June 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2067383
20 February 2004
Security Inspection
Physical examination · Activities Europe · Activity 2009802
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979552
16 September 2003
ACP COI Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1905591
11 June 2003
Internal Structural Exam · Re-Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1814396
23 July 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1654535
10 July 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443215
3 July 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379498
28 June 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424948
28 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047511
21 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454658
26 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360780
18 June 1998
Inclining Experiment · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392941
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 7 August 2018
Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Electrical › Electric Generation Source (service) › Generator
Issued 14 September 2016
Resolved
Prove operation of ship service generators. May be cleared by attending classification society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2016
Resolution: Class society verified repairs. Accepted class society verification as vessel is ACP.
See documents for related email/clearance.
Electrical › Electric Generation Source (service) › Generator
Issued 25 July 2016
Resolved
Demonstrate successful operation of ship's service generators prior to sailing.
Action required: 705 - Other - as specified
Resolved 14 September 2016
Resolution: Re-issued above COI to allow of clearance by Class society as vessel is enrolled into ACP Program.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 4 June 2012
Resolved
Ensure arrangements are provided for an alarm to be given of a fuel line failure for the high pressure fuel line system for all diesel engines having a continuous output of 375KW or more
Condition: Improper/Lack of Maintenance
Due 4 July 2012
Resolved 1 July 2012
Resolution: Letter received from Caterpillar stating the 3500 engine produces the high pressure at the injection unit.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 June 2012
Resolved
Ensure proper operating Marine Sanitation Device to the satisfaction of the attending ABS Surveyor.
Received email on 03Jul12 from the vessel operator stating this was corrected. No report from ABS
Condition: Improper/Lack of Maintenance
Due 4 July 2012
Resolved 24 August 2012
Resolution: Cleared by class after wintness of satisfactory test.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 June 2012
Resolved
Ensure proper operating Oily Water Separator to the satisfaction of the attending ABS Surveyor. All Oily bilge water to be retained on board and properly disposed of ashore until proof of proper operation of the OWS .
Received email on 03Jul12 from the vessel operator stating this was corrected. No report from ABS
Condition: Improper/Lack of Maintenance
Due 4 July 2012
Resolved 24 August 2012
Resolution: Cleared by class after wintness of satisfactory test.
Operations/Management › Pollution › Control of NOx
Issued 4 June 2012
Resolved
Ensure bunker samples are kept and maintained as required by Marpol VI.
Received email on 03Jul12 from the vessel operator stating this was corrected. No report from ABS
Condition: Improper/Lack of Maintenance
Due 4 July 2012
Resolved 24 August 2012
Resolution: Verified by class that vessel is now following proper procedure. notified by e-mail dtd 24AUG12 kept in ACTEUR vessel file.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2012
Resolved
Ensure proper operation of forward and aft mast anchor lights to the satisfaction of the attending ABS surveyor.
Received email on 03Jul12 from the vessel operator stating this was corrected. No report from ABS
Condition: Improper/Lack of Maintenance
Due 4 July 2012
Resolved 24 August 2012
Resolution: Cleared by class after wintness of satisfactory test. Notified via e-mail dated 24AUG12 and filed in ACTEUR vessel folder.
Construction/Loadline › Structures › Door
Issued 4 June 2012
Resolved
Repair cracked welds on stbd side embarkation door aft of pilot house main deck
Received email on 03Jul12 from the vessel operator stating this was corrected. No report from ABS
Condition: Damaged By Earlier Event
Due 4 July 2012
Resolved 24 August 2012
Resolution: Cleared by class after wintness of satisfactory test. Notified via e-mail dtd 24AUG12 and filed in ACTEUR vessel folder.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 June 2012
Resolved
Ensure all lighting fixtures are explosion proof in the paint locker to the satisfaction of the attending ABS surveyor.
Condition: Improper Installation
Due 4 July 2012
Resolved 24 August 2012
Resolution: Cleared by class after wintness of satisfactory install. Notified via e-mail 24AUG12 and filed in ACTEUR vessel folder.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 July 2009
Resolved
ITEM to be verified upon next CG attendance: Prove vessel's ability to follow ECO's drug & alcohol policy as it pertains to marine casualties and incidents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 16 August 2010
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 23 July 2009
Resolved
Provide a training manual accessible to the crew in accordance with SOLAS III 19/4, ensure it reflects the actual equipment onboard.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 July 2009
Resolved
properly secure SCBA bottles.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 July 2009
Resolved
ITEM to be verified upon next CG attendance: replace the line on the 0-1 deck buoys with new UV resistant line.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 16 August 2010
Fire Fighting › Fire Hydrants › Material
Issued 23 July 2009
Resolved
repair starb'd main deck fire hose box
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 23 July 2009
Resolved
replace rescue boat searchlight
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 23 July 2009
Resolved
ensure the resuce boat is outfitted with oar.
Condition: Unknown
Due 22 September 2009
Resolved 23 July 2009
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 July 2009
Resolved
replace or repair starboard side radar.
Due 28 July 2009
Resolved 24 July 2009
Engineering › Thrusters › Shaft
Issued 23 July 2009
Resolved
ensure that Z-drives do not drift from commanded position when operated from steering room.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Engineering › Thrusters › Tunnel
Issued 23 July 2009
Resolved
make adjustments to ensure all Z-DRIVE position indicators are aligned.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 23 July 2009
Resolved
ITEM to be verified upon next CG attendance: repair broken starb'd forward MDE shaft RMP gauge.
Due 22 September 2009
Resolved 16 August 2010
Engineering › Thrusters › Gland
Issued 23 July 2009
Resolved
repair hydraulic leaks to drop-down thruster.
Due 22 September 2009
Resolved 23 July 2009
Engineering › Bilge Water Management System › Manifold
Issued 23 July 2009
Resolved
label the bilge manifold valves.
Due 23 September 2009
Resolved 23 July 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 July 2009
Resolved
ITEM to be verified upon next CG attendance: repair emergency lighting in the engine control room.
Due 22 September 2009
Resolved 16 August 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 23 July 2009
Resolved
label port steering station clutch indicator in steering room as "clutch in" to match starboard station.
Action required: 705 - Other - as specified
Due 22 September 2009
Resolved 23 July 2009
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 June 2008
Resolved
Install steering disparity alarm IAW 46 CFR 113.43. See MSC approval letter E2-0703260 dated 30 Oct 07. Rec'd email from vsl master stating that the alarm has been installed and operating normally. The item will remain open until next USCG attendance to verify installation and operational check.
Due 15 October 2008
Resolved 16 August 2010
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 5 September 2007
Resolved
Replace expired line throwing appliance.
Item reported cleared via E-mail dated 01/10/07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 22 June 2008
Lifesaving › Launching Appliances › Falls
Issued 5 September 2007
Resolved
Replace falls for fast rescue boat in accordance with Manufactures requirements and SOLAS Chapter III regulation 20.4.1 This requirement is to be satisfied prior to the vessel departing dry-dock.
Item reported cleared via E-mail dated 01/10/07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 22 June 2008
Lifesaving › Launching Appliances › Release Mechanism
Issued 5 September 2007
Resolved
Conduct inspection of rescue boat winch, davit and hook release gear by approved manufactor's representitive.
Item reported cleared via E-mail dated 01/10/07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 22 June 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 28 May 2006
Resolved
Provide three spare batteries for the handheld GMDSS radios. This item was converted to an outstanding condition of class and reported cleared by ABS Lagos on May 31, 2006. Def will remain open for verification by CG inspector at next annual exam.
Action required: 705 - Other - as specified
Due 19 December 2007
Resolved 6 September 2007
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 28 May 2006
Resolved
Provide two spare SCBA air bottles. This item was converted to an outstanding condition of class and reported cleared by ABS Lagos on May 31, 2006. Def will remain open until verification by CG inspector at next annual exam.
Action required: 705 - Other - as specified
Due 19 December 2007
Resolved 6 September 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 28 May 2006
Resolved
Prove proper operation of the #1 SSDG over-speed. This item was converted to an outstanding condition of class and reported cleared by ABS Lagos on May 31, 2006. Def will remain open until verification by CG inspector at next annual exam.
Action required: 705 - Other - as specified
Due 19 December 2007
Resolved 6 September 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 August 2005
Resolved
Provide most recent editions of the following publications: List of Radio Signals, Intl Code of Signals, Tide and Current Tables, Sailing Directions and CFR Subchapter "L."
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 29 November 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 14 August 2005
Resolved
Replace/Recharge fire extinguisher #12.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 14 September 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Engineering › Pressure Vessel › Marking and Stamping
Issued 14 August 2005
Resolved
Provide data plate for relief on starboard air receiver.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 29 November 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 August 2005
Resolved
Provide non-conductive deck matting behind ECR switchboard.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 1 September 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 August 2005
Resolved
Repair OWS drain valve. Valve is leaking by.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 20 August 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 14 August 2005
Resolved
Replace inoperative alarm/status lights on ECR panel board.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 29 November 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 August 2005
Resolved
Clean excessive oil iwo drop down thruster deck and under thruster engine.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 15 August 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 August 2005
Resolved
Properly mount thermal detector above bulk tank compressor.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 20 August 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Lifesaving › Inflatable Liferafts › Capacity
Issued 14 August 2005
Resolved
Provide adequate life rafts iaw SOLAS 74, Chap III, Reg. 31.1.3.1, Reg. 31.1.3.2, Reg. 31.1.3.3 & Reg. 31.1.3.4 (Vessel required to have rafts on each side which will accommodate 150% of the total persons on board. In addition, if any one raft is lost or rendered unserviceable there shall be sufficient rafts available on each side for 100% of the persons on board.) Refer to narrative.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 29 November 2005
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 August 2005
Resolved
Proof proper operation of pressure gauge for port start air receiver.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 20 August 2005
Resolution: Cleared by e-mail. Deficiency will remain open pending on-scene verification by a Marine Inspector.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 10 September 2004
Resolved
Conduct external audit of ISM and provide results to cognizant [name withheld] audit to be completed prior to 17Sep04
Condition: Placed in Improper Service
Due 17 September 2004
Resolved 27 December 2004
Resolution: Completed by ABS
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 10 September 2004
Resolved
Provide approval letter for cargo securing manual verifying comments contained in 24MAR99 interim approval ltr have been completed prior to 10OCT04
Due 31 January 2005
Resolved 20 January 2005
Personnel › Certificates/Documents/Licenses › STCW Certificate, Navigation Watch Rating
Issued 10 September 2004
Resolved
Provide STCW certificates as "member of navigation watch" for all ab's and ordinary seaman. To be completed prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2004
Resolved 10 September 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 10 September 2004
Resolved
Vessel is limited to near coastal voyages whenever mates are assigned who only hold near costal endorsements
Due 29 September 2004
Resolved 27 December 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 September 2004
Resolved
Do not use OWS until Chief Engineer proves proper operation and testing procedures.
Condition: Placed in Improper Service
Due 10 October 2004
Resolved 27 December 2004
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 10 September 2004
Resolved
Prove proper testing of all P-tank relief valves.
Due 10 October 2004
Resolved 27 December 2004
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 September 2004
Resolved
Install electrical mat on floor of emergency generator room.
Due 10 October 2004
Resolved 10 September 2004
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 10 September 2004
Resolved
Install strobe light on fire detector (alarm) system in engine room.
Due 31 January 2005
Resolved 16 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 10 September 2004
Resolved
Provide on board vessel engine automation test procedures approved by USCG (MSC)
Due 10 October 2004
Resolved 27 December 2004
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 10 September 2004
Resolved
Prove proper operation of engine automation engine protections as required by 46CFR58.
Due 10 October 2004
Resolved 27 December 2004
Pollution Prevention/Response › Prevention Equipment
Issued 27 June 2003
Resolved
Repair OWS and provide proof of proper operation. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 27 June 2003
Resolved
Provide proof of annual hydro test for transfer hoses. LEGACY COMPONENT DESC: Transfer Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2003
Resolved 7 August 2003
Lifesaving › Rocket Parachute Flares
Issued 27 June 2003
Resolved
Provide (1) additional flare for a total of (12). LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Fire Fighting › Firemans Outfit
Issued 27 June 2003
Resolved
Provide (2) SOLAS approved flashlights for the fireman outfits. LEGACY COMPONENT DESC: Lantern (Electric Safety Lamp)
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2003
Resolved
Provide vessel with an oxygen analyzer as per SOLAS, chapter VI, regulation 3. LEGACY COMPONENT DESC: Oxygen Analyzer
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Engineering › Compressed Air System (start air)
Issued 27 June 2003
Resolved
Replace relief valve on the aft air compressor. LEGACY COMPONENT DESC: Compressor
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Communications › Internal Communications System
Issued 27 June 2003
Resolved
Repair the sound powered phone light in the rudder room. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2003
Resolved 7 August 2003
Operations/Management › Drills/Instruction
Issued 27 June 2003
Resolved
Provide an emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Operations/Management › Drills/Instruction
Issued 27 June 2003
Resolved
Provide a Lifesaving Signals and Helicopter Recovery Placard. LEGACY COMPONENT DESC: Lifesaving Signals and Helicopter Recovery Placard
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Engineering › Fuel Oil Service System
Issued 27 June 2003
Resolved
Replace or remove all petcocks on fuel filters to allow for plugs. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 27 July 2003
Resolved 7 August 2003
Communications › Alarms/Indicators › Fire Alarm
Issued 23 July 2002
Resolved
REPAIR FIRE ALARM BELL IN CONTROL ROOM.
Due 23 August 2002
Resolved 23 July 2002
Communications › Visual Communication › Red Warning Signal
Issued 23 July 2002
Resolved
REPAIR GENERAL ALARM LIGHT IN ENGINEROOM AND DRY BULK SPACES.
Due 23 August 2002
Resolved 23 July 2002
Documentation › Markings/Placards
Issued 23 July 2002
Resolved
PROVIDE AND POST ALL REQUIRED IMO SYMBOLS. LEGACY COMPONENT DESC: IMO SYMBOLS
Due 23 August 2002
Resolved 23 July 2002
Stability › Watertight Integrity
Issued 23 July 2002
Resolved
ADJUST ALL WATERTIGHT DOORS. LEGACY COMPONENT DESC: DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 July 2002
Lifesaving › Launching Appliances › Falls
Issued 23 July 2002
Resolved
RENEW OR END FOR END RESCUE BOAT DAVIT CABLE.
Due 23 August 2002
Resolved 24 July 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 July 2002
Resolved
MISSING CURRENT COPY OF TIDE TABLES.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2002
Resolved 23 July 2002
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 July 2002
Resolved
PROVIDE PROPER LOCATION FOR STORAGE AND CHARGING OF BATTERIES ON THE 02 DECK LEVEL.
Due 23 August 2002
Resolved 23 July 2002
Deck/Cargo
Issued 26 March 1999
Resolved
Prior to loading grade E cargo install proper valves on liquid mud pipes atliquid mud tanks. Present valves can be locked out from remote operation._x001C__x001C_ _x001C_
Condition: Unknown
Due 31 March 1999
Resolved 2 April 1999