C - EMPRESS

C - EMPRESS is a 1998 offshore supply vessel. The Coast Guard has recorded 37 inspections since 1998, most recently in May 2016, along with 88 deficiencies, 1 operational control and 2 casualty investigations between 2006 and 2012.

Records from 1998 to 2016. Most recent: inspection, 13 May 2016.

Built
1998
Last inspected
13 May 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9203825 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY2841
472074
Flag
UNITED STATES
366908000 (licence lapsed)
Maury page id
psix-472074

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (1998–2016)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 745
ITC dimensions (L × B × D)221.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 745
BuilderINGALLS SHIPYARDS · PASCAGOULA MS, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it745 - Convention (Subpart B), Net Ton
4854 - Displacement, Ton
3219 - Dead Weight, Ton
2092 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY2841MMSI 366908000 · expired · compulsorily equipped · granted 22 February 2008, cancelled 9 June 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHESTER MORRISON Offshore Supply Vessel · MISLE 512985 · 30 October 2006 · activity 2821595

Inspection history · 37

13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876258
17 October 2014 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5006979
13 October 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5029339
29 August 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4968871
22 August 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4967782
5 May 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4850945
13 February 2012 MTSA/ISPS Verification · Annual Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4228521
2 December 2010 Drydock Exam · MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3880568
13 February 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3435764
30 December 2008 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3394810
3 November 2008 Administrative Inspection · Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356349
22 September 2008 Administrative Inspection · Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3339995
28 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245353
2 January 2008 Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3123555
30 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2821595
28 September 2006 Hull Examination · Administrative Inspection · Re-Inspection · Cargo Tank Internal · MTSA/ISPS Verification · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2789323
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2749789
8 November 2005 Annual Inspection
Physical examination · Activities Europe · Activity 2530662
15 October 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2529271
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501663
14 May 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2421813
5 April 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2326597
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293920
27 January 2005 COI Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2271704
13 July 2004 Administrative Inspection
Administrative · Activities Europe · Activity 2131348
16 June 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2095159
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979564
25 September 2003 Internal Structural Exam · Periodic Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1856637
30 January 2003 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1737483
26 September 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1922945
9 August 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361651
7 July 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051898
11 January 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449285
23 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778363
11 March 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799272
19 November 1998 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436151
23 July 1998 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1130359

Deficiency record · 88

Stability › Watertight Integrity › General
Issued 13 February 2012 Resolved
Replace gasket and adjust escape hatches for Forepeak and After Steering.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Stability › Watertight Integrity › General
Issued 13 February 2012 Resolved
Adjust upper Engine Room and CO2 Room watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 February 2012 Resolved
Provide and prove proper operation of the Control Room smoke detector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 February 2012 Resolved
Make operable the Control Room emergency light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 13 February 2012 Resolved
Provide whistle and light for Control Room and After Steering lifejackets.
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 8 March 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 13 February 2012 Resolved
Replace flex hose on Paint Locker CO2 bottle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Electrical › Electric Supply System (service) › Transformer
Issued 13 February 2012 Resolved
Provide cover for the 440v transformer box in CO2 Room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 February 2012 Resolved
Adjust various fire screen doors throughout the vessel.
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 8 March 2012
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 13 February 2012 Resolved
Re-charge 4 spare air bottles and provide maintenance to the Bridge SCBA.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2012
Communications › Radio Communications › EPIRB
Issued 13 February 2012 Resolved
Renew EPIRB bracket/housing.
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 8 March 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 February 2012 Resolved
Renew stbd aft lifering floatlight.
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 8 March 2012
Accommodation/Occupational Safety › Ventilation › General
Issued 13 February 2012 Resolved
Replace gaskets on stack covers and emergency generator vent closure.
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 17 February 2012
Construction/Loadline › Markings › Load Line Mark
Issued 2 December 2010 Resolved
Paint/mark load line deck line.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Communications › Radio Communications › EPIRB
Issued 2 December 2010 Resolved
Provide proof of current EPIRB registration.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Lifesaving › Line-Throwing Appliances › Lines
Issued 2 December 2010 Resolved
Remove tools and trash from auxiliary line box.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 3 December 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2010 Resolved
Provide and install protective guard for electrical contactor in the Emergency Generator Room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 December 2010 Resolved
Make emergency lights operable in the Emergency Generator Room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 2 December 2010 Resolved
Make repairs and conduct operational tests of all fire dampers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Documentation › Logs/Records › Oil Record Book
Issued 2 December 2010 Resolved
Obtain and utilize the correct Oil Record Book Revision 01/07.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 12 May 2011
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 2 December 2010 Resolved
Provide a drug and alcohol policy in accordance with 46 CFR Part 16.
Action required: 705 - Other - as specified
Due 3 December 2013
Resolved 2 December 2010
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 2 December 2010 Resolved
Provide approved plans for the modifications and installation of the "SWACO" system.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 17 May 2011
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 2 December 2010 Resolved
Make proper repairs to the engine monitoring panel in E.C.R. (extinguished indicators).
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 3 December 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 December 2010 Resolved
Provide a line diagram for fixed CO2 extinguishing system at the weather deck pull station for Engine Room and 01 deck pull station for the emergency generator.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Stability › Watertight Integrity › General
Issued 2 December 2010 Resolved
Adjust all water tight doors throughout the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 2 December 2010 Resolved
Make permanent repairs to to the port MDE jacket water leak.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Engineering › Fuel Oil Service System › Piping
Issued 2 December 2010 Resolved
Make permanent repairs to the port generator F/O leak at the primary filters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Engineering › Fuel Oil Service System › Valve
Issued 2 December 2010 Resolved
Label the emergency generator fuel stop.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 3 December 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2010 Resolved
Properly dead-end loose wires in the emergency generator room.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 2 December 2010 Resolved
Provide properly secured and working heat detector in the emergency generator room.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 18 May 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 January 2008 Resolved
Prove proper operation of the OWS. Keep all oily water onboard to be discharged on shore.
Due 4 January 2008
Resolved 2 January 2008
Resolution: Received letter signed by [name withheld], Master of C-EMPRESS attesting to the satisfactory operation of the unit.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 2 January 2008 Resolved
Prove proper operation of port em steering and throttle.
Due 4 January 2008
Resolved 2 January 2008
Resolution: Received letter signed by [name withheld], Master of C-EMPRESS attesting to the satisfactory operation of the unit.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 2 January 2008 Resolved
Replace stbd emergency engine RPM indicator
Due 4 January 2008
Resolved 2 January 2008
Resolution: Received letter signed by [name withheld], Master of C-EMPRESS attesting to the satisfactory operation of the unit.
Fire Fighting › Fire Pumps › Pressure
Issued 2 January 2008 Resolved
Repair fire pump pressure gauge on bridge.
Due 4 January 2008
Resolved 2 January 2008
Resolution: Received letter signed by [name withheld], Master of C-EMPRESS attesting to the satisfactory operation of the unit.
Fire Fighting › Fire Pumps › Pressure
Issued 2 January 2008 Resolved
Repair fire pump pressure gauge on bridge.
Due 4 January 2008
Resolved 2 January 2008
Resolution: Received letter signed by [name withheld], Master of C-EMPRESS attesting to the satisfactory operation of the unit.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 28 September 2006 Resolved
Install flange shield on fuel transfer manifold flanges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 September 2006 Resolved
Properly wire in emergency light in emergency generator room. Splices with wire nuts is not authorized.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Engineering › Fuel Oil Service System › Flange
Issued 28 September 2006 Resolved
Install SOLAS spray tape on all pressurized piping > 26 psi.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 28 September 2006 Resolved
Renew light bulb in emergency generator switchboard for low oil pressure alarm.
Due 10 December 2006
Resolved 13 November 2006
Lifesaving › Rescue Boat › Markings
Issued 28 September 2006 Resolved
Renew SOLAS tape where ripped and peeling up.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 November 2005 Resolved
Prove proper operation of OWS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2005
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 30 November 2005 Resolved
Ensure proper operation of fire monitor. Missing flex coupling from the engine water cooling system. Prime mover in-operable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 30 November 2005 Resolved
Prove proper operation of the marine sanitation device. * Reported as completed by email. Must be verified by a Marine Inspector.
Due 1 January 2006
Resolved 29 December 2005
Resolution: Cleared by e-mail.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 November 2005 Resolved
Replace the cracked window in the engine control room.
Due 1 January 2006
Resolved 9 November 2006
Fire Fighting › Nozzles › Condition
Issued 30 November 2005 Resolved
Install fire swing motor on the port side monitor.
Due 1 January 2006
Resolved 9 November 2006
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 30 November 2005 Resolved
Repair port generator and port main crankcase ventilator winslow filter drain.
Due 1 January 2006
Resolved 29 December 2005
Resolution: Cleared by e-mail dated 29 December 2005.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 30 November 2005 Resolved
Oil record book not maintained in accordance with instructions. All machinery space operations to be recorded seperately from cargo operations. Vessel had no record of using the OWS since 12 October 2005.
Due 1 January 2006
Resolved 9 November 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 November 2005 Resolved
Complete automation testing in accordance with company safety management policy. * Reported as completed by email. Must be verified by a Marine Inspector.
Due 15 December 2005
Resolved 9 November 2006
Fire Fighting › Fire Hydrants › Condition
Issued 15 October 2005 Resolved
Repair port fire monitor
Due 15 October 2005
Resolved 30 November 2005
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 15 October 2005 Resolved
Repair fire alarm panel
Due 15 October 2005
Resolved 30 November 2005
Lifesaving › Rescue Boat › Construction
Issued 15 October 2005 Resolved
Repair rescue boat IAW acceptable fiberglass marine pratices
Due 15 October 2005
Resolved 30 November 2005
Lifesaving › Rescue Boat › Hull (rigid)
Issued 14 May 2005 Resolved
Found additional damage during def check for repaired grab rail. Vessel is resting on davit ram and chaffing hull iwo stiffener. Also found small punctures in port bow and deteriorated shell plugs in the gunwale. Contact boat manufacturer regarding damaged areas for recommendations. Also modify davit rests to raise boat off ram.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 30 November 2005
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 27 January 2005 Resolved
Prior to 1 May 2005 provide CG approved hydrostatic releases for life rafts. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 14 May 2005
Resolution: CG approved hydro releases onboard.
Operations/Management › Cargo Transfer/Lightering › Making a Connection
Issued 27 January 2005 Resolved
Prior to 27 March 2005 conduct satisfactory 1.5 MAWP pressure test of oil transfer hoses. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Due 27 April 2006
Resolved 14 May 2005
Resolution: Crew removed hoses from vessel.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 January 2005 Resolved
Prior to 27 March 2005 update oil transfer procedures to include person in charge designations and line diagrams. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Due 27 April 2006
Resolved 14 May 2005
Resolution: Procedures updated.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 27 January 2005 Resolved
Prior to 27 March 2005 update new hire program to address requirements of Shipboard Marine Oil Pollution Emergency Plan. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Due 27 April 2006
Resolved 14 May 2005
Resolution: New hire program updated.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 27 January 2005 Resolved
Prior to 27 March 2005 update cargo securing manual as required by approval letter and resubmit for final approval.
Due 27 March 2005
Resolved 14 May 2005
Resolution: Cargo securing manual updated and approved by ABS.
Engineering › Pressure Vessel › Relief Valve
Issued 27 January 2005 Resolved
Prior to 27 March 2005 conduct satisfactory pressure test of bulk tank relief valves.
Due 27 March 2005
Resolved 26 February 2005
Resolution: RECEIVED LETTER ATTESTING RELIEF VALVES WERE TESTED AND FOUND SAT.
Lifesaving › Lifebuoys › Size
Issued 27 January 2005 Resolved
Prior to 27 March 2005 provide 4 kilo ring buoys for bridge wing ring buoys. Based on email dated 31 March 2005 extended deadline two months while parts are on order. /s/ [name withheld]
Due 27 May 2005
Resolved 30 November 2005
Lifesaving › Buoyant Smoke Signals › General
Issued 27 January 2005 Resolved
Prior to 27 March 2005 provide CG approval info for bridge wing emergency light/smokes. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Due 27 April 2006
Resolved 14 May 2005
Resolution: Proper bridge wing emergency smokes provided onboard.
Communications › Alarms/Indicators › General Alarm
Issued 27 January 2005 Resolved
Prior to 27 March prove proper operation of engine room emergency strobe lights. Based on email dated 31 March 2005 extended deadline two months while parts are on order. /s/ [name withheld]
Due 27 May 2005
Resolved 30 November 2005
Lifesaving › Rescue Boat › Construction
Issued 27 January 2005 Resolved
Prior to 27 March 2005 provide repair plan for fast rescue craft to address missing rail/temp repairs to screw holes in hull. Received email dated 31 March 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Due 27 April 2006
Resolved 14 May 2005
Resolution: Revised deficiency and entered again based on onboard verification.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 July 2004 Resolved
Provide inspection of Fixed and portable firefighting systems by sept 2004.
Condition: Unknown
Due 30 September 2004
Resolved 27 January 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 July 2004 Resolved
Provide liferaft servicing by September 2004
Condition: Unknown
Due 30 September 2004
Resolved 27 January 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 November 2003 Resolved
Stencil Emergency Fuel shut downs not properly marked including direction of turn for OFF.
Due 6 December 2003
Resolved 27 January 2005
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 5 November 2003 Resolved
Ensure all required rescue boat equipment is stowed onboard the rescue boat (all equipment stowed in bridge house)
Due 6 December 2003
Resolved 27 January 2005
Navigation
Issued 25 September 2003 Resolved
- Ensure vessel has proper charts and required navigational publications (sailing directions, tide, current, light list).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2003
Navigation › Emergency Steering
Issued 25 September 2003 Resolved
Ensure the maneuvering information sheet has the warning posted at the bottom as per 33 CFR 164.35 (g)(7).
Due 25 November 2003
Resolved 13 November 2003
Resolution: On 13Oct03 received email from the [name withheld], master C-EMPRESS, stating that all outstanding items on the CG-835 had been corrected.
Navigation
Issued 25 September 2003 Resolved
Ensure vessel has simple operating instructions with a block diagram, showing the change over procedures for the remote steering gear control system permanently displayed on the navigational bridge and the steering gear compartment as per 33 CFR 164.35 (k).
Due 25 November 2003
Resolved 13 October 2003
Resolution: On 13Oct03 received email from the [name withheld], master C-EMPRESS, stating that all outstanding items on the CG-835 had been corrected.
Construction/Loadline
Issued 25 September 2003 Resolved
Ensure the Emergency Escape Hatches for the engine room and forward hold can be easily opened
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2003
Construction/Loadline
Issued 25 September 2003 Resolved
Ensure piping in #6 starboard ballast tank are properly repaired
Due 25 November 2003
Resolved 13 October 2003
Resolution: On 13Oct03 received email from the [name withheld], master C-EMPRESS, stating that all outstanding items on the CG-835 had been corrected.
Construction/Loadline
Issued 25 September 2003 Resolved
Ensure piping in the forward anti-roll tank is properly repaired.
Due 25 November 2003
Resolved 13 October 2003
Resolution: On 13Oct03 received email from the [name withheld], master C-EMPRESS, stating that all outstanding items on the CG-835 had been corrected.
Engineering
Issued 25 September 2003 Resolved
Ensure pressure vessel (in the paint locker) for fuel shut down has a pressure gauge to read pressure of the tank
Due 25 November 2003
Resolved 13 October 2003
Resolution: On 13Oct03 received email from the [name withheld], master C-EMPRESS, stating that all outstanding items on the CG-835 had been corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 September 2003 Resolved
Ensure EEBD is located in the Engine Room Control space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2003
Construction/Loadline
Issued 25 September 2003 Resolved
Owner / Operator must provide evidence that the U.S. Coast Guard granted permission to conduct an Under Water Exam in lieu dry dock in 19Nov01(date the vessel was required to have a Credited Coast Guard dry docking).
Due 25 November 2003
Resolved 1 October 2003
Resolution: On 01Oct03 [name withheld], ACID, MSO New Orleans sent email stating that due to a paper work error the M/V C-EMPRESS did have a credit dry dock conducted by ABS on behalf of the U.S. Coast Guard. Entry of the dry dock updated in MISLE by MSO New Orleans
Lifesaving › Rocket Parachute Flares › General
Issued 25 September 2003 Resolved
Ensure parachute flares are Coast Guard approved
Due 6 December 2003
Resolved 27 January 2005
Fire Fighting
Issued 25 September 2003 Resolved
Fire alarm panel Trouble Light (fault) was on. Corrected by technician while onboard.
Due 5 November 2003
Resolved 5 November 2003
Deck/Cargo
Issued 25 September 2003 Resolved
Bench test the pressure relief valves for the bulk tanks and liquid mud shutdown air tank (total of 5 relief valves)
Due 6 December 2003
Resolved 6 December 2003
Resolution: Received email from the master attesting the above pressure relief valves were tested and were found to be in proper working order.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 25 September 2003 Resolved
Ensure NOAA sticker is placed on the EPIRB
Due 6 December 2003
Resolved 27 January 2005
Engineering
Issued 19 November 1998 Resolved
Racor filters have plastic plugs in bottom of flame shields, plugs are for alarm wires. Replace with metallic plugs.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Navigation
Issued 19 November 1998 Resolved
Provide GMDSS installation report and copy of application for Safety Radio Cert.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Documentation
Issued 19 November 1998 Resolved
Provide list of piping systems that contain miter cut joints and approved plans for those systems._x001C_ Miter cuts were used instead of fittings as indicated on plans.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Lifesaving
Issued 19 November 1998 Resolved
Provide straps for stokes litter to hold victim in litter.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Navigation
Issued 19 November 1998 Resolved
Prove proper operation of Port propeller RPM gauge.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Navigation
Issued 19 November 1998 Resolved
Prove proper operation of EOT warning horn at emergency steering location.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Lifesaving
Issued 19 November 1998 Resolved
Provide instructions for rescue boat davit operations.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Documentation
Issued 19 November 1998 Resolved
Correct training manual to show boarding, launching and clearing of rescue boat. Recovery, stowage and securing of rescue boat. Manual onboard has rescue platform information not rescue boat.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Electrical
Issued 19 November 1998 Resolved
Install Auto start and load shedding on main generators swithboards.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998
Lifesaving
Issued 19 November 1998 Resolved
Install appropriate IMO symbols for lifesaving equipment as required.
Condition: Unknown
Due 19 November 1998
Resolved 19 November 1998

Casualty record · 2

30 October 2006Routine · role: Involved in a Marine Casualty · activity 2821595
20 March 2012Routine · role: Involved in a Marine Casualty · activity 4269509
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.