Inspection history · 22
13 July 2026
In-Service Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8437489
5 May 2025
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113848
22 October 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8040706
8 May 2023
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7688879
10 May 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7447507
1 March 2022
Deficiency Check · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7403118
7 February 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7392253
20 September 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339398
24 September 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7064904
5 August 2020
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026301
28 May 2020
COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6962560
1 October 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6859480
11 April 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667700
20 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619895
12 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599665
27 September 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6547681
10 October 2017
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6289540
3 July 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6198902
1 June 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167142
10 January 2017
Plan Review "T" Boat · Inclining Experiment · Construction Oversight · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6093854
26 October 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6032996
14 April 2016
In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5873678
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 July 2026
Resolved
During an In-Service Inspection, MI's found multiple hull plate fractures allowing the ingress of water into the #2 void. Crop and renew affected areas to the satisfaction of Coast Guard Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2026
Resolved 21 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 10 May 2022
Resolved
The man overboard recovery davit is jammed and not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Witnessed proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 May 2022
Resolved
Vessel's crew was unable to complete a satisfactory man overboard drill. Demonstrate crew competency to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Witnessed satisfactory drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2022
Resolved
The aft fire hose had multiple leaks throughout its length. Replace with satisfactory fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 31 May 2022
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 September 2021
Resolved
Genset forward flexible wet exhaust piping deteriorated, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2021
Resolved
main deck RLB is deteriorated, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 September 2021
Resolved
IBA cradle cracked, must be repaired/replaced after this operating season.
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 1 March 2022
Resolution: IBA cradle properly repaired.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 September 2021
Resolved
Spanner wrench at main deck fire station not the correct size for the hose fitting, must be replaced with correct size wrench.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 September 2021
Resolved
Fire pump flexible pipe has leak, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 September 2021
Resolved
Engine room access hatch cover gasket must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 26 October 2021
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 28 May 2020
Resolved
Port remote fuel shutoff valve found to leak during opening and closing of the valve. Make fuel shutoff valve operable to the satisfaction of the Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 23 July 2020
Resolution: Replaced with new valve, operational check completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019
Resolved
Replace 57 rejected adult PFDs. Inspected all [name withheld] PFDs and found 56 had cracked coating and when manipulated cracks continued into the buoyancy foam. Replaced all 56 and 1 other rejected prior to our departure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
Resolution: replaced prior to departure from vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 September 2018
Resolved
First frame afore the collision bulkhead fractured at attachment to port chine, must be permanently repaired prior to operating in 2019 and before 31MAY2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 11 April 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 September 2018
Resolved
First frame afore the aft bulkhead in void #1 fractured near port chine, must be permanently repaired prior to operating in 2019 and before 31MAY2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 11 April 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2018
Resolved
Replace deteriorated ring life buoy at wheelhouse before 11OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2018
Resolved
Portable fire extinguisher at upper deck exterior in poor but operable condition, base rusted, pressure gauge illegible, tamper seal missing, must be serviced or replaced before 11OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: replaced with inspection ready PFE.
Engineering › Steering Gear System › Linkage
Issued 10 October 2017
Resolved
Helm excessively loose on hydraulic unit spindle at operating station, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: corrected during inspection.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 10 October 2017
Resolved
Conductors loose on main engine cranking battery terminals, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: corrected during inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 October 2016
Resolved
Provide record of current radio inspection for VHFFM marine radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 1 June 2017
Resolution: Sighted.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 26 October 2016
Resolved
Port and starboard fuel oil tank vents shall be fitted with removable flame screen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 1 June 2017
Resolution: Installed.
Stability › Watertight Integrity › General
Issued 26 October 2016
Resolved
Lubricate and demonstrate proper operation of forepeak scuttle, before carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 1 June 2017
Resolution: Corrected, found to be operational.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2016
Resolved
Make permanent repairs to last transverse frame in void #1 beneath cabin, in way of connection to 2nd bottom longitudinal stiffener inboard of port chine, according an approved repair proposal.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 10 April 2017
Stability › Intact Righting Energy › General
Issued 26 October 2016
Resolved
All buoyancy foam is deteriorated and must be replaced according to approved plans, to include a resilient covering to resist penetration by oils and vapor.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 17 April 2017