FELICITY

Built
1972
Last inspected
13 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 July 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY2616
Flag
UNITED STATES
Maury page id
psix-47208

Documentation record

Registered dimensions (L × B × D)64.7 ft × 18.1 ft × 8.3 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROWN POINT, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMACKINAW CITY, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 21 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

13 July 2026 In-Service Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8437489
5 May 2025 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113848
22 October 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8040706
8 May 2023 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7688879
10 May 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7447507
1 March 2022 Deficiency Check · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7403118
7 February 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7392253
20 September 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339398
24 September 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7064904
5 August 2020 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026301
28 May 2020 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6962560
1 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6859480
11 April 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667700
20 November 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619895
12 November 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599665
27 September 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6547681
10 October 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6289540
3 July 2017 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6198902
1 June 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167142
10 January 2017 Plan Review "T" Boat · Inclining Experiment · Construction Oversight · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6093854
26 October 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6032996
14 April 2016 In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5873678

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 July 2026 Resolved
During an In-Service Inspection, MI's found multiple hull plate fractures allowing the ingress of water into the #2 void. Crop and renew affected areas to the satisfaction of Coast Guard Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2026
Resolved 21 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 10 May 2022 Resolved
The man overboard recovery davit is jammed and not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Witnessed proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 May 2022 Resolved
Vessel's crew was unable to complete a satisfactory man overboard drill. Demonstrate crew competency to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
Resolution: Witnessed satisfactory drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2022 Resolved
The aft fire hose had multiple leaks throughout its length. Replace with satisfactory fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 31 May 2022
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 September 2021 Resolved
Genset forward flexible wet exhaust piping deteriorated, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2021 Resolved
main deck RLB is deteriorated, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 September 2021 Resolved
IBA cradle cracked, must be repaired/replaced after this operating season.
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 1 March 2022
Resolution: IBA cradle properly repaired.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 September 2021 Resolved
Spanner wrench at main deck fire station not the correct size for the hose fitting, must be replaced with correct size wrench.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 September 2021 Resolved
Fire pump flexible pipe has leak, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 26 October 2021
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 September 2021 Resolved
Engine room access hatch cover gasket must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 26 October 2021
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 28 May 2020 Resolved
Port remote fuel shutoff valve found to leak during opening and closing of the valve. Make fuel shutoff valve operable to the satisfaction of the Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2020
Resolved 23 July 2020
Resolution: Replaced with new valve, operational check completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019 Resolved
Replace 57 rejected adult PFDs. Inspected all [name withheld] PFDs and found 56 had cracked coating and when manipulated cracks continued into the buoyancy foam. Replaced all 56 and 1 other rejected prior to our departure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
Resolution: replaced prior to departure from vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 September 2018 Resolved
First frame afore the collision bulkhead fractured at attachment to port chine, must be permanently repaired prior to operating in 2019 and before 31MAY2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 11 April 2019
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 September 2018 Resolved
First frame afore the aft bulkhead in void #1 fractured near port chine, must be permanently repaired prior to operating in 2019 and before 31MAY2019.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 11 April 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2018 Resolved
Replace deteriorated ring life buoy at wheelhouse before 11OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2018 Resolved
Portable fire extinguisher at upper deck exterior in poor but operable condition, base rusted, pressure gauge illegible, tamper seal missing, must be serviced or replaced before 11OCT2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 25 October 2018
Resolution: replaced with inspection ready PFE.
Engineering › Steering Gear System › Linkage
Issued 10 October 2017 Resolved
Helm excessively loose on hydraulic unit spindle at operating station, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: corrected during inspection.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 10 October 2017 Resolved
Conductors loose on main engine cranking battery terminals, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: corrected during inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 October 2016 Resolved
Provide record of current radio inspection for VHFFM marine radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 1 June 2017
Resolution: Sighted.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 26 October 2016 Resolved
Port and starboard fuel oil tank vents shall be fitted with removable flame screen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 1 June 2017
Resolution: Installed.
Stability › Watertight Integrity › General
Issued 26 October 2016 Resolved
Lubricate and demonstrate proper operation of forepeak scuttle, before carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 1 June 2017
Resolution: Corrected, found to be operational.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2016 Resolved
Make permanent repairs to last transverse frame in void #1 beneath cabin, in way of connection to 2nd bottom longitudinal stiffener inboard of port chine, according an approved repair proposal.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 10 April 2017
Stability › Intact Righting Energy › General
Issued 26 October 2016 Resolved
All buoyancy foam is deteriorated and must be replaced according to approved plans, to include a resilient covering to resist penetration by oils and vapor.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2017
Resolved 17 April 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.