MAURY USCG vessel records Sign in
← All vessels

OCEAN VICTORY

OCEAN VICTORY is a 1972 research vessel. The Coast Guard has recorded 82 inspections since 1985, most recently in January 2026, along with 73 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2011.

Records from 1985 to 2026. Most recent: inspection, 20 January 2026.

Built
1972
Last inspected
20 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7121140 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG8218
Flag
UNITED STATES
303327000
Maury page id
psix-47209

Inspections, by type

…with no type recorded16
…past their stated due date1
Years with a record 38 calendar years (1985–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)205.7 ft × 56.0 ft × 15.4 ft
Registered tonnagegross 497 / net 338
ITC dimensions (L × B × D)205.0 ft × 56.0 ft × 16.0 ft
ITC tonnagegross 2,257 / net 677
BuilderAMERICAN MARINE CORP · NEW ORLEANS, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 April 2026 · expires 31 May 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it497 - Regulatory (Subpart C or D), Gross Ton
2257 - Convention (Subpart B), Gross Ton
338 - Regulatory (Subpart C or D), Net Ton
677 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG8218MMSI 303327000 · active · compulsorily equipped · granted 14 March 2023, expires 18 May 2033
WZH2523MMSI 367124340 · expired · compulsorily equipped · granted 23 August 2006, cancelled 12 November 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

20 January 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8300946
29 July 2025 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8197748
22 February 2025 MARPOL Annex I Examination · In-Service Inspection · COI Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8088990
6 May 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7921931
8 December 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7836343
28 August 2023 MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7778943
8 August 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7763669
24 August 2022 Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7542157
16 August 2021 MARPOL Annex IV Survey · Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7288501
23 September 2020 MARPOL Annex VI Survey · Deficiency Check · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7063444
10 July 2020 Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7017136
14 May 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6986506
9 September 2019 Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6807192
18 December 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6599720
24 August 2018 Periodic Inspection · ISM Oversight · MTSA Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6521246
2 April 2018 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6383060
31 March 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6387579
30 March 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6383062
14 July 2017 MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Activities Europe · Activity 6209166
22 February 2017 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6092403
16 March 2016 MARPOL Annex VI Survey · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 5824498
28 August 2015 Permit to Proceed
Administrative · Activities Europe · Activity 5231870
14 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5231866
8 October 2014 MTSA/ISPS Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Activities Europe · Activity 4997196
27 June 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4365103
29 September 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4098556
4 September 2011 Type not recorded
No type recorded · Activities Europe · Activity 4138297
8 August 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4112848
29 July 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4098587
13 October 2010 Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3869224
18 November 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202210
13 May 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3036399
24 April 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2916912
6 December 2005 MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2546821
21 December 2004 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2263347
9 December 2004 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2256582
6 April 2004 Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2038347
13 February 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2006105
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971049
26 March 2003 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1762937
17 December 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1736364
13 February 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1486364
31 January 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440481
5 April 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369604
21 January 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418642
24 February 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1473095
7 July 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 793736
13 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 778778
10 December 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1436019
20 February 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445162
25 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445082
9 March 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433014
25 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1189812
28 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1191797
5 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1192233
22 March 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1174360
30 March 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1169182
18 February 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1164448
16 April 1993 Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 837777
29 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829921
1 December 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830396
7 April 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258165
4 October 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 941357
24 April 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 932515
9 October 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1215893
5 September 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241662
3 April 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1237985
1 December 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898682
29 September 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1314069
25 September 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898246
19 April 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886481
9 November 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353155
7 April 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1344132
3 December 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335712
20 October 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329425
10 April 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304699
18 March 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1305284
15 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996589
15 October 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994750
11 October 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302211
8 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292061
27 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1291995

Deficiency record · 73

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 7 March 2025 No resolution recorded
The owner of a vessel subject to inspection under section 3301 shall-(1) ensure that such vessel is equipped with a vessel master key control, Signage, and Surveillance requirements regarding the Coast Guard's Sexual Assault and Sexual Harassment Prevention and Response programs for commercial vessels. Follow guidance in implementation IAW Coast Guard Policy Letters 23-04, 23-05, and 23-06. Vessel owner will ensure vessel is in compliance with the cited policy upon completion of the current DoD contract.
Action required: 705 - Other - as specified
Due 7 March 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2024 Resolved
Structural repair deficiencies found during DD/ISE. Crop and renew as identified in worklist (uploaded).
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2024
Resolved 12 June 2024
Resolution: All worklist items repaired and tested, SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 August 2021 Resolved
Each Class 2 watertight door must be designed, constructed, tested, and marked in accordance with ASTM F 1196 (incorporated by reference, see §170.015). Steering gear room, forward port and starboard engine room doors exceeded closure tolerances per ASTM F 1196. To be completed by Dry dock 2022 to the satisfaction of attending marine inspector and ABS
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 October 2022
Resolution: Examined proper installation of new class 3 water tight doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 August 2021 Resolved
The following plans must be submitted to the Coast Guard for approval in accordance with §50.20-5 and §50.20-10 of this chapter: Design Verification and Periodic Safety test procedures described in subpart 61.40 of this chapter. Approved DVTPs do not match current vessel configuration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2021
Resolved 3 October 2022
Resolution: Vessel has approved DVTPs, and Now PSTPs. The current PSTPS have been sent to MSC for final review.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 August 2021 Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Test points for main diesel engine were not set in accordance with approved DVTP.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2021
Resolved 21 August 2021
Resolution: Adjusted automation system to match approved DVTP
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 August 2021 Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Generators #1,2 and 3 set points identified as follows: oil pressure was designed to be set to 30PSI but alarmed at 20PSI, jacket water temp designed to be set to 200 degrees Farenheit but alarmed at 212, oil temp designed to be set to 200 degrees Farenheit but alarmed at 208. Set points were corrected on the spot, deficiency cleared
Action required: 10 - Deficiency Rectified
Resolved 18 August 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 September 2020 Resolved
A fixed carbon dioxide fire extinguishing system complying with 46 CFR 95.15 and 95.16 must be installed for internal combustion engine installations. CO2 remote pulley covers for 90 degree bends, melted and plastic. Must replace and have servicing company approve system.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 September 2020
Resolution: Viking serviced system and changed out corner pulley cover plates that were damaged. System was retested.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 24 September 2020 Resolved
Each rudder angle indicator must have a transmitter at the rudder head that is activated by movement of the rudder. Rudder angle indicators at Engine Room and Bridge wing are off up to 10 degrees. Submit a technician report certifying that all rudder angle indicators are accurate with the rudder. Vessel restricted to 12nm of the Charleston Sea buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2020
Resolved 28 September 2020
Resolution: Received Technician report
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 24 September 2020 Resolved
Each embarkation station must be adequately illuminated by lighting with power supplied from vessel's emergency source of power. Port and Stbd muster stations at lifesaving embarkation area does not have adequate lighting. Vessel restricted to 12nm of the Charleston Sea buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2020
Resolved 7 October 2020
Resolution: Vessel installed LED Spot light and put on emergency bus.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 September 2019 Resolved
The power watertight door in the Engine Room is delayed in operation. Prove proper operation of the power-operated watertight door to open and close in the required amount of time.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2019 Resolved
During testing of the Engine Room CO2 system, found the 30 second time delay activated in 27 seconds. Replace time delay and prove proper operation to the satisfaction of the attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2019 Resolved
Several portable and semi-fixed CO2 hoses are rotted. Repair discharge hoses or replace extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 September 2019 Resolved
The stbd machinery space emergency escape scuttle has a broken handwheel guard and the hatch needs to be adjusted to make watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 September 2019 Resolved
Found the forward Galley emergency escape scuttle not watertight. Adjust to make watertight to the satisfaction of the attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2019 Resolved
The Bridge lifebuoys are not sufficient for use as a deployable buoy with a smoke float attached. Provide and install the correct "bridge" lifebouys.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 September 2019 Resolved
The following vent screens were found wasted and are to be replaced: port side main deck fuel vent, port side 02 deck fuel vent, #2 stbd fuel tank vent, and the stbd waste oil tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
The #2 & #3 SSDG's have non-metallic hoses from the jacket water expansion tank to the engine cooling piping system that are bent and twisted causing a safety hazard. Realign and/or replace the flexible hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 September 2019 Resolved
The Engine Room bulkhead penetration, stbd forward side, is not watertight. Properly seal the bulkhead penetration to the satisfaction of the attending CG marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
The distribution panels in the Engine Room don't have updated breaker index's due to modifications. Provide a proper directory for each panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 24 August 2018 Resolved
Holes and penetrations in structural bulkheads allowing passage of flame and smoke. Make immediate temporary repairs prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2018
Resolved 30 August 2018
Resolution: cleared
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 24 August 2018 Resolved
Structural bulkheads do not meet the requirement ot prevent the passage of flame and smoke. Make permanent repair to the satisfaction of the OCMI prior to departure from shipyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 23 August 2019
Resolution: Vessel installed proper wire penetrations in the bulkheads that require them.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 30 March 2018 Resolved
Vessel failed to submit a Notice of Arrival as required by 33 CFR Part 160, Subpart C.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 30 March 2018
Resolution: Vessel submitted NOA.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 March 2018 Resolved
Vessel entered port in Apra Harbor Guam without a vessel response plan approved for COTP zone Guam.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 31 March 2018
Resolution: Vessel received a one-time waiver for entry into COTP Zone Guam.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 March 2016 Resolved
Jacket water leaking from Gen #1 due to blown hose.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced blown hose.
Engineering › Fuel Oil Service System › Piping
Issued 16 March 2016 Resolved
Reach rod rubbing on air pipeline
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Moved air pipeline to give clearance for reach rode.
Engineering › Compressed Air System (control) › Valve
Issued 16 March 2016 Resolved
Starboard aft MDE Air Reciever Safety Relieve Valve not working properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced Air reciever safety relief valve.
Construction/Loadline › Penetrations › Gasket
Issued 16 March 2016 Resolved
Watertight door next to E-Gen room has gaps at the seam
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced gasket.
Engineering › Fuel Oil Service System › Hose
Issued 16 March 2016 Resolved
Unapproved fuel hose installed on the #2 and #3 MDE Generators
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced fuel hoses.
Lifesaving › Buoyant Apparatus › Marking
Issued 16 March 2016 Resolved
Life Buoy markings faded.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced life buoy.
Electrical › Electric Generation Source (service) › Panelboard
Issued 16 March 2016 Resolved
Panel-board P-18 and P-6 missing breaker blanks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Installed breaker panel blanks.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 16 March 2016 Resolved
CO2 Extinguisher #9 has crack in the hose.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced hose.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 March 2016 Resolved
Missing guard for globe light fixture fwd center well
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Replaced entire light fixture, globe and guard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 March 2016 Resolved
Bulk head penetration holes in oxygen room.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 April 2016
Resolved 17 March 2016
Resolution: Plugged holes with pipe plugs.
Lifesaving › Launching Appliances › Davit
Issued 8 October 2014 Resolved
ENSURE RECUE BOAT DAVIT IS OPERATES AS DESIGNED, DAVIT ACCUMULATOR DOES NOT HOLD DESIGNED PRESSURE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2014
Resolution: Received service report from Solas Marine Service, Bahrain that the launching appliance was inspected and found "fit for purpose".
Electrical › Lighting (service) › Lighting Fixture
Issued 8 October 2014 Resolved
ENSURE STARBOARD DECK LIGHT NEAR PILOT HOUSE DOOR IS PROPERLY MOUNTED.
Condition: Improper/Lack of Maintenance
Due 8 December 2014
Resolved 17 October 2014
Resolution: Received email from master with photograph showing proper repair.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 October 2014 Resolved
ENSURE OILY WATER SEPARATOR IS FUNCTIONAL IN THAT THE SUPPLY PUMP IS REPAIRED OR REPLACED. THE VESSEL MUST RETAIN ALL OILY SLUDGE ABOARD AND DISCHARGED TO AN APPROVED SHORE SIDE FACILITY UNTIL THE OILY WASTER SEPARATOR HAS BEEN REPAIRED
Condition: Improper/Lack of Maintenance
Due 8 December 2014
Resolved 17 October 2014
Resolution: Received an email from the master with an attached report or order for the part, oil pump from the sludge tank to the OWS, has been orderd and enroute. Vessel will retain all oily sludge aboard until the pump has been installed and operational.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 8 October 2014 Resolved
ENSURE ALL PAINT AND OIL LOCKERS ARE CONSTRUCTED OF STEEL OR WHOLLY LINED IN METAL
Condition: Improper Installation
Due 8 December 2014
Resolved 17 December 2014
Resolution: Received email from the master stating the metal paint lockers have been ordered from the U.S.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 October 2014 Resolved
ENSURE THE ENTRANCE TO THE SPACE STORING, A SPACE PROTECTED BY OR ANY SPACE WHICH CO2 MAY MIGRATE TO IS CONSPICUOUSLY MARKED AS PER 46 CFR 196.37-8
Condition: Invalid
Due 8 December 2014
Resolved 17 October 2014
Resolution: Received email from the master with a photograph of the placarding for the spaces have been made.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 8 October 2014 Resolved
ENSURE VESSEL HAS NON EXPIRED DISTRESS SIGNALS (PARACHUTE FLARES)
Condition: Invalid
Due 8 December 2014
Resolved 17 October 2014
Resolution: Received email from the master stating they have acquired 12 SOLAS approved flares locally and two smoke cans. I have also ordered them from the U.S. and they were shipped but have not made it to the vessel yet.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 29 September 2011 Resolved
Insert ship specific procedures in the SOLAS Training Manual, in the places provided at the end of each chapter.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 7 October 2011
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 September 2011 Resolved
Provide a copy of the fire control plan on the outside of the house near the gangway in accordance with SOLAS 74/78 II-2/20
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 10 October 2011
Engineering › Steering Gear System › Ram Seal
Issued 29 September 2011 Resolved
Repair the hydraulic oil leak on the port - outboard steering ram.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 4 October 2011
Resolution: Seal replaced.
Fire Fighting › Fire Main › Condition
Issued 29 September 2011 Resolved
Repair pin-hole leak in the engine room fire pump discharge pipe flange.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 4 October 2011
Resolution: Pipe removed and flange rewelded by shipyard. Installed and tested satisfactorily.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 September 2011 Resolved
Install self closing valves on the sight glass for the emergency generator fuel storage tank.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 23 October 2011
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 29 September 2011 Resolved
Hydro-test all air receivers on the vessel. This may be accomplished at next drydock scheduled on or before 30 Apr 2012. The air receiver next inspection due dates listed on the Certificate of Inspection are extended until 30 Apr 2012.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 6 April 2012
Resolution: Conducted satisfactory hydrostatic test at 125% of MAWP on all 4 pressure vessels.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 September 2011 Resolved
Submit plans to the Marine Safety Center for approval of the alternative Oily Water Separator and Marine Sanitation Device treated water discharge piping systems. This item must be completed to the satisfaction of [name withheld] by the date specified and before operating on an international voyage.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 30 November 2011
Documentation › Certificates/Documents › Stability Letter
Issued 29 September 2011 Resolved
Submit to the Marine Safety Center for approval, changes to the stability book and stability instructions necessary when using the #4 port outboard ballast tank as a treated water holding tank. This item must be completed to the satisfaction of [name withheld] by the date specified and before operating on an international voyage.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 30 November 2011
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 August 2011 Resolved
Remove the oily water separator clean water discharge piping arrangement from the oil content meter to the #4P outboard ballast tank. Pipe the OCM clean water discharge to an acceptable overboard discharge location via a skin valve. Prior to making piping changes, submit plans to the Marine Safety Center for approval. Receive approval and installation verification prior to an international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2011
Resolved 4 October 2011
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 18 November 2007 Resolved
Prove proper operation of the low lube oil shut-down on the port, center and starboard ship service electrical generator diesel engines.
Due 18 December 2007
Resolved 19 June 2009
Resolution: A test loop was installed in the oil pressure sensor line so that pressure could be released and the shutdown tested without affecting the engine.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 18 November 2007 Resolved
Provide written test procedures for the low lube oil test procedures for the ship service generators.
Action required: 705 - Other - as specified
Due 18 December 2007
Resolved 5 January 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 18 November 2007 Resolved
Provide written test procedures for the low lube oil test procedures for the main engines.
Due 18 December 2007
Resolved 4 January 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 18 November 2007 Resolved
Provide written procedures for testing the ship service generator reverse power relays.
Action required: 705 - Other - as specified
Due 18 December 2007
Resolved 4 January 2008
Lifesaving › Launching Appliances › Falls
Issued 6 December 2005 Resolved
Conduct weight test of the port and STBD L/B after end-end of the falls.
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 4 January 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 December 2004 Resolved
Repair ventilation closures for emergency generator space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2005
Resolved 21 December 2004
Lifesaving › Lifebuoys
Issued 26 March 2003 Resolved
Quick release ring buoys on bridge wings not 4 Kg type.
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 26 March 2003
Lifesaving › Launching Appliances
Issued 26 March 2003 Resolved
Provide proof that new wire rope installed for lifeboat falls meets safety criteria iaw 46 CFR 199. LEGACY COMPONENT DESC: Falls
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 2 April 2003
Lifesaving › Launching Appliances
Issued 26 March 2003 Resolved
Conduct lifeboat weight tests on both port and starboard lifeboats iaw 46 CFR 199.45.
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 11 April 2003
Construction/Loadline
Issued 10 December 1997 Resolved
Guage tank top and inboard forward end of #3 port ballast tank in way of frames 24 and 25. Tank top has holes in it. The purpose is to determine extent of wastage so that a proper repair can be completed.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Construction/Loadline
Issued 10 December 1997 Resolved
Crop and renew wasted first bulkhead stiffener and first under-deck longitudinalin #5 port ballast tank inboard forward corner.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Construction/Loadline
Issued 10 December 1997 Resolved
Crop and renew tank top and any other areas wasted more than 25%.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Construction/Loadline
Issued 10 December 1997 Resolved
Reweld penetration in crane foundation in #4 port outboard ballast tank at crane electrical conduit.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Fire Fighting
Issued 7 April 1992 Resolved
PROVIDE A COPY OF THE FIRE EXTINGUISHER SERVICING COMPANY CERTIFICATE FOR THE SEPTEMBER/OCTOBER 1991 SERVICING.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Fire Fighting
Issued 7 April 1992 Resolved
TEST OR REPLACE THE HAND PORTABLE FIRE EXTINGUISHERS IN BOTH LIFEBOATS.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Lifesaving
Issued 7 April 1992 Resolved
CONDUCT A BIENNIAL WEIGHT TEST OF BOTH LIFEBOATS.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Electrical
Issued 4 October 1991 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR IN ACCORDANCE WITH THE COAST GUARD APPROVED PLANS.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Electrical
Issued 4 October 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR THE NEW EMERGENCY GENERATOR.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Construction/Loadline
Issued 4 October 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR THE EMERGENCY DE-WATERING PUMP FOR THE MOON POOL (AFT BULKHEAD OF MOON POOL).
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Engineering
Issued 5 September 1990 Resolved
PROVIDE A TEST PROCEDURE FOR THE AUTOMATION TO REFLECT THE MODIFICATIONS INCURRED DURING THE INSTALLATION OF THE NEW TRACOR MARCON 6350 AUTOMATION SYSTEM. PROVIDE THIS PROCEDURE FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Engineering
Issued 5 September 1990 Resolved
PROVE PROPER OPERATION OF COAST GUARD APPROVED TEST PROCEDURE UPON COMPLETION OF APPROVAL PROCEDURE FOR NEW TRACOR MARCON 6350 SYSTEM.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Construction/Loadline
Issued 9 November 1988 Resolved
MAKE PERMANENT REPAIRS TO STRUCTURAL LEAKS AT OUTBOARD PORT SHELL AT ATTACHMENTS OF THE OMNITHRUSTER; TO BE COMPLETED AT THE NEXT DRYDOCKING. TEMPORARY REPAIRS MAY BE EFFECTED UNTIL SUCH DRYDOCKING.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Unknown
Issued 9 November 1988 Resolved
PROVIDE CG APPROVED PLANS FOR THE OMNITHRUSTER INSTALLATION.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Engineering
Issued 8 April 1985 Resolved
PROVE OPERATION OF ENGINE ROOM AUTOMATION SYSTEM.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Engineering
Issued 8 April 1985 Resolved
PROVIDE AN AUTOMATION TEST PROCEDURE TO [name withheld]/LB.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985

Casualty record · 1

4 September 2011Routine · role: Involved in a Marine Casualty · activity 4138297
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DENNY TIDE (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.