Records from 1991 to 2024. Most recent: inspection, 3 December 2024.
Inspection history · 20
3 December 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042637
25 November 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8039993
30 March 2023
Periodic Inspection · ACP Periodic Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7659648
21 March 2022
Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7415571
4 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7406120
27 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7298319
11 May 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7195215
3 May 2021
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7188333
4 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6920787
11 February 2020
ACP COI Oversight · COI Inspection · ACP Drydock Oversight · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6872526
9 December 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6870653
21 September 2019
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6818808
20 September 2019
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6815868
11 January 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6609291
4 June 2018
In-Service Inspection · Deficiency Check · Administrative Inspection · ISM Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6435307
15 March 2018
Deficiency Check · In-Service Inspection · Re-Inspection · Administrative Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6372316
25 January 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6343575
25 April 2017
In-Service Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6132881
28 September 2016
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6011508
2 May 2016
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5865923
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 25 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port RPM indicator on bridge was inoperable.
74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 4 February 2025
Resolution: RO accepted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Gooseneck vent on flight deck near fire station 33 serving void space found holed at the base near bolted connection.
74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2024
Resolved 4 February 2025
Resolution: RO accepted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 March 2023
Resolved
The means for securing and maintain weathertightness shall be to the satisfaction of the Administration. Main deck aft house has warped ventilation closure located on the main deck port side that will not form a proper seal when secured.
ICLL(05) II/16
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 11 September 2023
Resolution: Verified proper closure.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 March 2023
Resolved
A training manual complying with the requirements of paragraph 3 shall be provided in each crew mess room and recreation room or in each crew cabin. SOLAS training manual onboard has outdated portion relating to open lifeboats which do not reflect lifeboats onboard.
74 SOLAS (20) III/35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2023
Resolved 11 September 2023
Resolution: Verified updates to training manual.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 March 2022
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment covered by the survey without the sanction of the Administration. Corroded area of ventilation trunk on aft port weatherdeck serving Pt Supply Mooring Space found holed.
60 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 31 March 2022
Resolution: Accepted by ABS
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Dead wires present of forward amidship portion of flying bridge. Properly terminate or remove dead end wires.
60 SOLAS II/27
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Breaker in main deck laundry near gangway has deteriorated and incorrect labeling, #7 listed as spare but was energized. Properly relabel panel.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Containment for forward settling tank (between bosun stores & locker) holed at the base near gooseneck and no longer capable of serving its function. Affect proper repairs to containment.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. 01 to 02 level stair (aft house) has a loose handrail. Affect proper repairs to handrail.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Bottom side of port bridge wing vent trunk that leads to electric room on bridge is wasted. Affect proper repairs.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Gooseneck on flight deck port side (3C DB HFO) and gooseneck near fire station 29 on flight deck were missing securing pins for vent cover. Replace securing pins.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Electric box for DFM Filling Tank Level Alarm System on port and starboard sides has wasted electric outlets and bottom is no longer secured to prevent water ingress. Replace or remove.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Several containments on main deck aft completely filled with water and no longer capable of serving as containment.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Gaskets on main deck house closures (forward of 5P hold) are dry rotted. Replace gaskets.
74 SOLAS I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2020
Resolved 5 February 2020
Resolution: TPO accepted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship is all respects will remain fit to proceed to sea without danger to the ship or persons on board. The flame screen on the stbd bunker station is unattached, re-attach. 74SOLAS(14)I/11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship is all respects will remain fit to proceed to sea without danger to the ship or persons on board. The steering gear had several linkage arm connections without a method to retain the bolts. 74SOLAS(14)I/11.1 (corrected on-the-spot, cotter keys installed)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 11 January 2019
Resolution: Cotter keys installed, corrected on-the-spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship is all respects will remain fit to proceed to sea without danger to the ship or persons on board. (7) easing gear cables are unserviceable, renew cables. 74SOLAS(14)I/11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 January 2019
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire main gauge line IWO shaft alley WTD is corroded, replace. 74SOLAS(14)II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 January 2019
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Each lifeboat's pryo has expired. All lifeboat equipment must be serviceable and onboard prior to the vessel leaving berth. 74SOLAS(14)III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The following material deficiencies were noted on the cargo E-deck:
-The electrical conduits for (3) high bilge level alarms are holed and do not provide sufficient protection as designed -Two of the high level alarms have been removed from the bilge well and are resting the cargo deck, and therefore would not alarm unless the entirety of the cargo deck flooded -The vents for a stbd fwd fuel tank and the 5 center fuel tank are holed -The forward port side drainage pipe is holed in multiple places
74SOLAS(14)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 January 2019
Resolved
The ship shall be fitted either with permanent bulwarks at least 1m in height, specially stiffened on the upper edge and supported by strong bulwark stays attached to the deck and provided with necessary freeing ports, or with efficient rails of the same height and of specially strong construction. There are (3) stiffener brackets on the forward weather deck (IVO mooring chocks) that are holed. D-rings and/or cleat adjacent to the wasted stiffeners are also corroded and not suitable for service. Additionally, the railing by the port gangway hydraulic control box is severed. ICLL II/43(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 January 2019
Resolution: Item accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 January 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The following material deficiencies were noted on the weather deck:
-The hatch coaming on the Aft 7 cargo hold manhole is holed, allowing water ingression to the cargo decks -Structure on the port side fwd of the gangway is holed near the deck -Electrical conduits are severely holed IVO the port gangway crane -The rail supporting the port crane hydraulics control box is severely corroded structurally inadequate -Stbd fwd vent truck on the fore castle has a hole on the aft face IVO the gasket
-#1 Deep HFO vent containment is holed
-Multiple vent containments on the main deck are missing plugs and/or their captive devices
74SOLAS(14)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 January 2019
Resolution: Item accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2019
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The stbd side B-Deck Foam Station #60 has a ball shut off valve which is not operating properly. 74SOLAS(14)II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 15 January 2019
Resolution: Item accepted by ABS.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 June 2018
Resolved
A marine casualty occurred on 27 May 2018 in which a mooring line parted and severely injured multiple crew. Upon inspection, the vessel's mooring lines were found heavily worn and deteriorated and the vessel had no accurate records of installation, maintenance, or inspections. Vessel shall develop and implement planned maintenance as outlined in the vessel's SMS. 33 CFR 96.240(b) ISM Code Part A 10.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 June 2018
Resolution: ISM Audit and NC issued by ABS.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 4 June 2018
Resolved
Vessels in oceans service shall be fitted with hawsers in general agreement with the Standards established by the American Bureau of Shipping. Based on material condition of the hawsers, the ALGOL shall provide objective evidence that they are in keeping with the standards published by ABS. 46 CFR 96.07-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2018
Resolved 11 January 2019
Resolution: New mooring line provided as per ABS spec.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2018
Resolved
Vessel overdue for ACP Annual oversight as of 1 June 2017.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Inspection completed.