Records from 1998 to 2007. Most recent: inspection, 11 September 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
11 September 2007
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3055100
22 May 2007
Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2966868
1 August 2006
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2733050
20 July 2006
MTSA/ISPS Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2719133
18 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2517029
20 June 2005
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2396812
20 May 2005
Hull Examination · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2386234
23 July 2004
MTSA/ISPS Verification · Drydock Extension · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2143067
7 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066522
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970923
29 July 2003
COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1860426
13 June 2002
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1627894
2 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1065938
3 May 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443169
30 May 2000
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448124
17 August 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777715
2 August 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 774790
29 April 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126263
24 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426199
9 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804974
1 October 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799058
15 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 54700
6 May 1998
Deadweight Survey · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378367
30 January 1998
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400771
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 July 2006
Resolved
Properly mount and route electrical supply to freezer located in machine shop space.
Due 30 July 2006
Resolved 1 August 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 20 July 2006
Resolved
Renew machine shop vent supply fan starter box.
Due 30 July 2006
Resolved 1 August 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2006
Resolved
Renew battery boxes in way og the port main engine and the generators.
Due 30 July 2006
Resolved 1 August 2006
Construction/Loadline › Structures › Ventilators
Issued 20 May 2005
Resolved
Provide engineering report for cracking in the port and starboard mid-ship section of the bulwarks
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 18 October 2005
Resolution: DEf cleared after discussion with CID, [name withheld], and [name withheld] that hull condition and cracking did not warrant an engineering analysis
Construction/Loadline › Structures › Ventilators
Issued 20 May 2005
Resolved
Monitor and report to MSO New Orleans any additional cracking and repairs made to the port and starboard bulwarks.
Due 20 May 2007
Resolved 2 June 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 May 2005
Resolved
Prove proper operation of fuel valve reach rods.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 20 May 2005
Resolved
Provide engineroom automation test report.
Due 20 June 2005
Resolved 20 June 2005
Navigation › Piloting/Steering › Pelorus
Issued 20 May 2005
Resolved
Repair abrasions to pilot house windows.
Due 20 July 2005
Resolved 18 October 2005
Resolution: See ltr from Master in documents
Lifesaving
Issued 30 May 2000
Resolved
Vessel to provide current registered EPIRB with valid hydrostatic release prior to sailing. Master is to fax statement verfuying working EPIRB onboard to [phone withheld]. Vsl is in no sail status until cleared.
Condition: Unknown
Due 30 May 2000
Resolved 12 June 2000
Unknown
Issued 24 March 1999
Resolved
PROVIDE REQUIRED ASME "U" STAMP AS PER 46 CFR 54.01-5(C)3 AND (C)4 FOR PRESSURE VESSELS CURRENTLY ONBOARD. VESSEL SHALL INFORM THE ATTENDING MARINE INSPECTOR REGARDING A PROPOSAL TO ACCOMPLISH THE ABOVE.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Unknown
Issued 24 March 1999
Resolved
VESSEL IS TO PROVE APPLICATION OF CORRECT LOADLINE(PUNCHED AND PAINTED) IDENTICAL TO CURRENT LOADLINE CERTIFICATE TO BE WITNESSED BY A CG MARINE INSPECTOR OR PROVIDE ABS OUTSTANDING CONDITION OF CLASS REPORT.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 24 March 1999
Resolved
PROVIDE UPDATED RADIOTELEPHONY CERTIFICATE WITH CORRECT CALL SIGN. TELEPHONY CERTIFICATE CALL SIGN SHOULD MATCH RADIO STATION LICENSE.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Fire Fighting
Issued 6 May 1998
Resolved
CONDUCT ABANDON SHIP, MAN OVERBOARD, AND FIRE DRILLS AS REQUIRED BY 46CFR 185.520 AND 185.524 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Documentation
Issued 6 May 1998
Resolved
PROVIDE ON BOARD A VALID F.C.C. RADIO SAFETY CERTIFICATE AS REQUIRED BY 47CFR 80.903.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Documentation
Issued 6 May 1998
Resolved
PROVIDE ON BOARD A VALID COMPASS DEVIATION CARD.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998