Records from 2014 to 2026. Most recent: inspection, 10 June 2026.
Inspection history · 31
10 June 2026
Type not recorded
No type recorded · USCGC DANIEL TARR (WPC-1136) · USCG Heartland District (CGD-H) · Activity 8401269
20 April 2026
Vessel Attendance · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8340528
3 September 2025
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226025
9 August 2025
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8219157
1 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8129718
20 March 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8097045
31 October 2024
Examination of Repairs · Administrative Inspection · Special
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8027772
2 May 2024
Special Consideration · Special · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7885269
7 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7823930
28 June 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7725906
19 May 2023
Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7694860
9 March 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648483
1 August 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7513699
9 May 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7446653
3 May 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7188295
30 March 2021
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7165366
28 July 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7018585
18 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814639
21 August 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6790988
13 August 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6782367
4 April 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6656136
27 July 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6492296
26 July 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6491720
16 October 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291680
19 September 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6275591
18 July 2017
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6212848
17 July 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6216195
3 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137952
31 March 2017
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6114912
13 July 2016
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 5939940
26 April 2016
Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5862726
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2023
Resolved
The master shall conduct sufficient fire drills to make sure that each crewmember is familiar with his or her duties. Vessels crew failed to competently conduct engine room fire drill. Conduct fire training with the crew and be prepared to repeat drill in the presence of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Master and Crewmember conducted 3 drills; engine room, galley microwave and lithium ion battery fire. All drills sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 July 2023
Resolved
Each vessel that operates on the high seas must have on board a FCC type Vessels EPIRB. EPIRB is not mounted. Mount EPIRB
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: New EPIRB was mounted in same location of old EPIRB, new hydrostatic release installed, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2023
Resolved
Shutoff valves, installed so as to close against fuel flow must be fitted on fuel supply lines….normally operable from outside the compartment. Fuel cut off valves were inoperable. Show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Fuel Cut off pull cables were serviced and one replaced, cable clamp was repositioned and both valves tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2023
Resolved
All life jackets have worn retro-reflective material. Each life jacket must be marked with type I retro-reflective material approved in accordance with 46 CFR 164.018 or other standard approved by the commandant. The arraignment of the retro-reflective material must be as specified by IMO Resolution A.658(16). Renew retro-reflective.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Retro-reflective tape was renewed on all life-jackets on-board, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water lever in each space to include unmanned spaces with through hull valves below the vessels deepest load waterline, machinery space bilge, bilge well, shaft alley or other spaces subject to flooding, a space with a non-water tight hatch on the main deck. Vessel was unable to locate and/or test the forward cabins high bilge alarm. Make high bilge alarm both operable and audible at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Aft engine room high level alarm had faulty bulb, new instalation of light was inspected sat. Advised to label locations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2023
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring life buoy was missing retro-reflective tape. Vessel limited to daylight operations until 2" of retro-reflective tape is applied to four evenly spaced points around or on both sides of the body of the life buoy. Retroreflective material on ring life buoy is missing in places and needs to be renewed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Retro-reflective tape was installed on life ring, sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 July 2023
Resolved
At each inspection the bilges and other spaces may be examined to see there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Vessels engine room, primarily the starboard side has engine leaking excessive oil on and below the engine, missing intake filters causing fine particulate oil mist to emit during operation, oily rags in the bilge, oil in the overhead and the engines raw water pump access plate is leaking. Clean and make available for re-inspection of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 27 July 2023
Resolution: Bilges and excessive oil was cleaned off, bilges were cleaned and raw water pump leak secured. Advised to install oil diaper rags under the engines to ensure no pollution.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 July 2023
Resolved
Each battery used in an item of lifesaving equipment, must be replaced during the annual inspection if the expiration of the battery has passed. While both operational, ring life buoy water light battery & port life float battery were expired. Vessel is limited to daylight operations only until batteries are replaced with unexpired batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 27 July 2023
Resolution: Both float lights were replaced with approved ACR led style marker lights, sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 July 2023
Resolved
At each inspection the steering system shall be made available for inspection and prepared to test to the extent necessary to determine that they are in suitable condition and fit for the service intended. Vessels steering ram was missing mounting bolt. Replace bolt.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: Bolt and nut were reinstalled in steering gear assmebly.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 July 2023
Resolved
A vessel must be fitted with ground tackle necessary for the vessel to safely anchor. Vessels D-ring attaching the anchor to the anchor chain was wasted. Replace D-ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: New anchor hardware installed.
10 - Safety of Navigation › N/A - No Subsystem › GNSS receiver/terrestrial radio navigation system
Issued 24 July 2023
Resolved
General equipment requirements for all ships subject to this subpart shall be provided with equipment capable of transmitting an automatic distress alert which includes position of the ship must have either an integral navigation receiver or capability of being connected to an external navigation receiver. Vessels VHF does not have a latitude and longitude input. Show VHF with lat/long coordinates.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: New VHF radio installed with GPS. Verified MMSI input and radio check, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 July 2023
Resolved
Operational readiness, maintenance, and inspection of lifesaving equipment is not being logged or overwise documented for review by the U.S. Coast Guard. Implement log.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: Began log for safety equipment maintenance, drills, and vessel maintenance.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 July 2023
Resolved
A power-driven vessel underway shall exhibit sidelights. Vessels starboard navigation sidelight was not operating as intended. Show proper operation of navigation light. Daylight only operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 27 July 2023
Resolution: New nav light installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 July 2023
Resolved
On a vessel where the upper decks on the vessel are limited the maximum number of passengers allowed on the upper deck must be indicated in durable marking of at least 1” numbers and letters at the entranceway to that deck. Vessel did not have signage stating no passengers on the 02 deck. Install signage preventing passengers on the 02 deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 27 July 2023
Resolution: "Crew only" sign installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete required drydock examination. Vessel restricted from operating until drydock examination is conducted.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2023
Resolution: drydock inspection complete
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2022
Resolved
Vessels without power driven fire pump must have at least three 2.5 gallon buckets attached with lanyards. Vessel doesn't have fire buckets on board. Show proper installation of fire buckets.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2022
Resolved 1 August 2022
Resolution: Received objective evidence of installed fire buckets.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 August 2022
Resolved
Each vessel that operates on the high seas must have on board a FCC type Vessels EPIRB. EPIRB is registered in the previous owner and vessel name. Renew EPIRB documentation to show current vessel name and owner and install sticker on EPIRB.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2022
Resolved 25 August 2022
Resolution: Received documentary evidence of FCC registration on current vessel name.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 1 August 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel had no alcohol swabs on board. Provide enough alcohol swabs to test all members that could be directly involved in a Serious Marine Incident. Vessel is limited to an operating area that is within 2 hours of ability for chemical testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2022
Resolved 1 August 2022
Resolution: Received objective evidence of replaced testing devices.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 August 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection against person. Machinery guards are missing on stbd engine and generator. Reinstall guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 1 August 2022
Resolution: Received objective evidence of reinstallation of machinery guards.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2022
Resolved
Each conductor must be made within an enclosure. Dead-end wiring was noted in engine room. Remove or enclose in a junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 1 August 2022
Resolution: Received objective evidence of electrical repairs.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 August 2022
Resolved
Vessel subject to Part III of title III of the communications act must have a detailed inspection of radio installation by an FCC licensed tech every 5 years and issued a safety radiotelephony certificate. Vessels radiotelephony cert was expired. Provide current FCC radiotelephony cert.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2022
Resolved 3 October 2022
Resolution: documentary evidence received
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022
Resolved
A vessel must have one or more ring life buoys on board. Vessels life ring buoy is worn beyond its service life. Repair or replace life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2022
Resolved 3 October 2022
Resolution: documentary evidence received.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2022
Resolved
Each battery must be located in a well ventilated space and protected from falling objects. Batteries were missing their protective covers. Reinstall covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 1 August 2022
Resolution: Received objective evidence of replaced covers on all batteries.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 May 2021
Resolved
Vessels EPIRB registration was expired. Vessel is limited to 3NM from shore until EPIRB registration is renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2021
Resolved 10 May 2021
Resolution: Submitted proof of registration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 May 2021
Resolved
Vessel has a opening in the FWD collision blkhd. Vessel must make watertight the opening in the collision blkhd.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2021
Resolved 10 May 2021
Resolution: Provided proof of repair.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 May 2021
Resolved
Vessels port side engine room vent closure broke during op test. Repair broken vent closure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2021
Resolved 10 May 2021
Resolution: Provided proof of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
Vessels port rudder post packing gland was leaking during op test. Tighten rudder packing gland.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 10 May 2021
Resolution: Provided proof of repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
Vessels alcohol testing swabs were expired. Replace alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 10 May 2021
Resolution: Replaced alcohol swabs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2021
Resolved
Vessels emergency lighting in the fwd cabin area was found to be very dim when tested. Replace batteries in fwd e-lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 10 May 2021
Resolution: Batteries replaced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 May 2021
Resolved
Vessel was missing the most recent Light List, Coast Pilot, and Local Notice to Mariners to update charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 10 May 2021
Resolution: Provided proof of updated Light List, Coast Pilot, and Local Notice to Mariners.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 August 2020
Resolved
GENERATOR EXHAUSE HOSE IS WORN, CRACKED AND IN NEED OF REPLACING.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2020
Resolved 18 August 2020
Resolution: Vessel O/O submitted objective evidence clearing deficiency
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 August 2020
Resolved
VESSEL NEEDS CURRENT CHARTS FOR OPERATING AREA AND APPROACH. REPLACE WITH CURRENT CHARTS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2020
Resolved 18 August 2020
Resolution: Vessel O/O submitted objective evidence clearing deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 August 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel's chart is out of date. Must have updated chart onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2019
Resolution: Purchased an up to date chart.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2019
Resolved
Vessel is over due for an Annual Inspection beyond the 3 month window of the anniversary date. Vessel is no longer in compliance with its COI, rendering it invalid. Vessel may not operate with passengers until an Annual Inspection is completed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2019
Resolution: Vessel Owner provided payment for user fees.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2018
Resolved
NLT 24OCT18 Vessel shall provide a special consideration request to allow PVC piping in bilge system or remove all rigid non-metallic piping in the bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 28 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2018
Resolved
Life float painter line frayed. Replace painter line.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: The life painter line was completely replaced
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 July 2018
Resolved
FLoating waterlight for life float requires an 18ft lanyard attached around the body of the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: Floating waterlight lanyard was renewed with 18 feet of line attached around the life float
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 July 2018
Resolved
Life ring buoy is deteriorated. Replace as necessary.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: Owner provided an approved replacement life ring
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 July 2018
Resolved
FCC Radio Station Authorization is expired. Provide new Station Authorization.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: Owner provided a new FCC Radio Station Authorization Certificate
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 July 2018
Resolved
Provide up to date/corrected charts and Local Notice to Mariners.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: Owner provided new charts that were up to date and Local Notice to Mariners
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2018
Resolved
One hose clamp on port main engine exhaust broken. Provide new clamp.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2018
Resolved 20 August 2018
Resolution: New clamp was installed on Port Main Engine exhaust
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 19 September 2017
Resolved
Lube oil guage for STBD main engine was found inoperable. Repair or replace guage to prove proper opperation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2017
Resolved 16 October 2017
Resolution: Sending unit was replaced and oil preasure guages operation was witnessed sat. Def Cleared.
Construction/Loadline › Structures › Deck Plating
Issued 18 July 2017
Resolved
Repair damaged fiberglass and electrical caused by fire damage to the satisfaction of the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 September 2017
Resolution: Effective repairs have been made.
Deck/Cargo › Fishing › General
Issued 20 April 2017
Resolved
Replace/repair cracked pipe on port outrigger.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 3 May 2017
Resolution: Repairs made to port outrigger.
Engineering › Bilge Water Management System › Piping
Issued 20 April 2017
Resolved
Replace all rigid non-metallic piping in bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 July 2018
Resolution: Cleared deficiency and subsequently reissued IAW SECMOB OCMI guidance regarding PVC piping in bilge systems.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 May 2016
Resolved
Needs a better seal when shut or closed during E/R fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Provided sufficient insulation to properly secure fire vent dampers.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 May 2016
Resolved
Outlets in E/R need new covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Replaced outlets in E/R with new covers.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 9 May 2016
Resolved
Update charts and nav rules book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Charts and nav rules book was updated.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 May 2016
Resolved
Missing smoke detectors in each accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Provided smoke detectors in each accommodation space.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 May 2016
Resolved
Emergency instructions not posted at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Emergency instructions were posted at operating station.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 May 2016
Resolved
DAPI letter needs updated with new crew member.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: DAPI letter was updated with new crew member.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 May 2016
Resolved
VHF radio at operating station needs the DSC switch. Also new safety cert for new radio.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Replaced radio at operating station with DSC switch. Provided new safety certificate.