HAWAIIAN RAINBOW

HAWAIIAN RAINBOW is a 1972 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in July 2011, along with 120 deficiencies — 2 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2004 and 2005.

Records from 1985 to 2011. Most recent: inspection, 19 July 2011.

Built
1972
Last inspected
19 July 2011
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ5490
Flag
UNITED STATES
366773620 (licence lapsed)
Maury page id
psix-47224

Inspections, by type

…with no type recorded16
…past their stated due date1
Years with a record 24 calendar years (1985–2011)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.7 ft × 19.5 ft × 6.7 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIARD BOAT WORKS · COSTA MESA CA, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ5490MMSI 366773620 · expired · compulsorily equipped · granted 29 August 2009, cancelled 28 December 2019
WCP4665MMSI not assigned · expired · compulsorily equipped · granted 21 December 1994, cancelled 26 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

19 July 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4087745
18 July 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4086505
13 October 2010 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3869483
2 April 2009 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3445286
1 May 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3196538
3 July 2007 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2959970
26 February 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2976091
31 March 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2611607
18 April 2005 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2336915
1 April 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2324092
17 March 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2320236
2 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2025166
7 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2025877
2 May 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1785241
21 January 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1733382
26 December 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1695113
19 November 2001 Deficiency Check · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370421
9 April 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379364
13 January 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1045523
2 December 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812891
2 December 1999 Plan Review "T" Boat · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375989
5 October 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386607
15 November 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1184365
9 November 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 676901
28 September 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385548
20 September 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1462463
2 September 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 34208
27 July 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446244
23 June 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392249
21 January 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1183068
17 November 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370952
15 November 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 707495
12 September 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372460
15 November 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1426845
14 October 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1468301
13 September 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442060
26 July 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154237
15 December 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 830735
16 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 831392
8 April 1992 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357924
13 March 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 944613
5 December 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248269
18 March 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 920397
14 February 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219692
8 January 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902508
27 December 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 917585
20 December 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1220311
13 November 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235711
7 November 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 912892
13 March 1990 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 906572
24 January 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902713
9 February 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1035569
22 December 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1347878
22 September 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340376
15 April 1988 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1195218
12 February 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1335353
16 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004992
18 February 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314043
22 October 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316719
11 March 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 992267
3 March 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989554
13 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300682
13 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 981428
23 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980973

Deficiency record · 120

Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 April 2009 No resolution recorded
Complete an approved Coast Guard 5-year (COI) inspection prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Serviceable
Issued 1 May 2008 Resolved
3 life ring buoys are deteriorated due to ultraviolet light deterioration. Provide 3 serviceable buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 2 May 2008
Resolution: New life rign buoys purchased for vessel.
Communications › Radio Communications › EPIRB
Issued 1 May 2008 Resolved
Renew hydrostatic release on EPIRB.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 2 May 2008
Resolution: New hydrostatic release purchased for EPIRB
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2008 No resolution recorded
Remove dead end wires forward of collision bulkhead.
Action required: 705 - Other - as specified
Due 7 May 2008 — due date passed with no resolution recorded
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 3 July 2007 Resolved
Replace all propelller shaft strut bearings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 24 July 2007
Resolution: Strut bearings renewed, shafting reinstalled and engines realigned.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 July 2007 Resolved
Ensure all oily water is removed from bilges. Engine rooms and compartments fwd of E/R's.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 24 July 2007
Construction/Loadline › Structures › Superstructure
Issued 3 July 2007 Resolved
Provide approval letter for the installation of the covering on the upper deck. If approval letter is not available, submit plans to USCG Sector Honolulu, Prevention Dept. Plans need to include: Design and construction layout, type of materials used in framing and cover, and approximate total weight of materials installed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2007
Resolved 10 August 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 March 2006 Resolved
Service engine room fixed firefighting system; provide record of servicing prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2006
Resolved 1 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 March 2006 Resolved
Service all out of date fire extinguishers prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2006
Resolved 19 April 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 March 2006 Resolved
Replace all lifejackets identified during exam.
Condition: Improper/Lack of Maintenance
Due 17 April 2006
Resolved 19 April 2006
Construction/Loadline › Structures › Door
Issued 31 March 2006 Resolved
Repair crack at forward watertight door, reweld and remove crack.
Condition: Improper/Lack of Maintenance
Due 17 April 2006
Resolved 19 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2006 Resolved
Remove dead end wiring throughout vessel (engine compartments, forward collision space, sewage holding tank, etc.).
Condition: Improper/Lack of Maintenance
Due 17 April 2006
Resolved 19 April 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 31 March 2006 Resolved
Provide metal fasteners throughout vessel.
Condition: Improper/Lack of Maintenance
Due 17 April 2006
Resolved 19 April 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 31 March 2006 Resolved
Provide working tachometer at operating station (starboard engine).
Condition: Improper/Lack of Maintenance
Due 27 April 2006
Resolved 27 April 2006
Resolution: Tachometer installed and operating properly.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 March 2006 Resolved
Mark fuel cutoff switches.
Due 17 April 2006
Resolved 19 April 2006
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 31 March 2006 Resolved
Mount refrigerator & ice maker.
Condition: Improper Installation
Due 17 April 2006
Resolved 19 April 2006
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 31 March 2006 Resolved
Mount hot water heater in engine compartment (starboard side).
Condition: Improper Installation
Due 17 April 2006
Resolved 19 April 2006
Construction/Loadline › Structures › Manhole
Issued 31 March 2006 Resolved
Provide chain to permanently attach manhole covers to the deck.
Condition: Improper Installation
Due 17 April 2006
Resolved 19 April 2006
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 31 March 2006 Resolved
Ensure all smoke detectors installed and working properly.
Due 17 April 2006
Resolved 19 April 2006
Navigation › Piloting/Steering › Marine Charts
Issued 31 March 2006 Resolved
Provide navigation charts for operating areas.
Due 17 April 2006
Resolved 19 April 2006
Engineering › Fuel Oil Service System › Filter
Issued 31 March 2006 Resolved
Fuel filters must be provided with metal bowls, ensure installed as per CFR's.
Condition: Improper Installation
Due 17 April 2006
Resolved 19 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 31 March 2006 Resolved
Repair high-water alarms on vessel (prove proper operations).
Due 17 April 2006
Resolved 19 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 31 March 2006 Resolved
Permanently mount bilge pump and hose throughout vessel.
Due 17 April 2006
Resolved 19 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 31 March 2006 Resolved
Replace or repair covers on lights throughout the vessel.
Condition: Improper/Lack of Maintenance
Due 17 April 2006
Resolved 19 April 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 31 March 2006 Resolved
Make engine room space vapor tight, IAW 46 CFR 182.465.
Due 17 April 2006
Resolved 19 April 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove combustibles/trash from port engine room battery box and fit with suitable cover IAW 46 CFR 176.25-50 and 183.05-20.
Due 15 April 2005
Resolved 2 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove excess oil and debris from port engine room bilge IAW 46 CFR 176.25-50.
Due 15 April 2005
Resolved 1 April 2005
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 1 April 2005 Resolved
Plug (2) two holes in aft bulkhead of port engine room making space vapor tight.
Due 15 April 2005
Resolved 7 July 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove excess oil and debris from stbd engine room IAW 46 CFR 176.830(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove inoperable salt water pump and associated wiring from stbd engine room.
Due 15 April 2005
Resolved 1 April 2005
Fire Fighting › Means of Escape › Blocked
Issued 1 April 2005 Resolved
Remove snorkel gear from emergency egress route located aft of collision bulkhead IAW 46 CFR 176.830(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove combustibles/debris from forepeak space IAW 46 CFR 176.25-50.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 1 April 2005 Resolved
Remove dead end wires/old lighting from forepeak space.
Due 15 April 2005
Resolved 7 July 2005
Construction/Loadline › Structures › Deck Plating
Issued 1 April 2005 Resolved
Make temporary repair to rotted/soft wood located IWO fwd escape hatch stbd side. Permenant repair to be made at vessel drydock NLT 30MAY05.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove oil and combustibles from stbd storage area aft of engine room in vicinity of breaker boxes IAW 46 CFR 176.25-50.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 April 2005 Resolved
Repair passenger seating on upper deck port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 April 2005 Resolved
Remove combustibles/debris from behind radio panel/operating station IAW 46 CFR 176.25-50.
Due 15 April 2005
Resolved 7 July 2005
Engineering › Bilge Water Management System › Not Operational
Issued 1 April 2005 Resolved
Prove operation of bilge systems IAW 46 CFR 182.25-10.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 April 2005 Resolved
Prove operation of fixed firefighting system engine shutdowns IAW 46 CFR 181.420. Install heat detector with audible alarm at operating station while waiting on parts for relay switch (stbd engine room system). Permanent repairs to be made NLT 8APR05.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2005
Construction/Loadline › Structures › Deck Plating
Issued 1 April 2005 Resolved
Renew rotted deck (approx 5' X 3' section) located above #2 space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2005 Resolved
Prove operation of navigation lights IAW 46 CFR 183.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 April 2005 Resolved
Perfom MOB and fire drills.
Action required: 705 - Other - as specified
Resolved 2 April 2005
Communications › Audible Communications › SPD (Other)
Issued 1 April 2005 Resolved
Prove operation of public address system as required by 184.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 April 2005 Resolved
Replace EPIRB battery IAW 46 CFR 180.64. Vessel route restricted to no more than (1) one mile from shore until replacement battery is received.
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 7 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 July 2004 Resolved
Remove all dead end wires below operating station IAW 46 CFR 183.340.
Due 16 July 2004
Resolved 2 July 2004
Resolution: All dead end wires removed/secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 July 2004 Resolved
Remove inoperable high level bilge alarm indicator from operating station IAW 46 CFR 182.530.
Due 16 July 2004
Resolved 2 July 2004
Lifesaving › Lifebuoys › Serviceable
Issued 2 July 2004 Resolved
Replace line around port side ring buoy located at operating station IAW 46 CFR 180.70.
Due 16 July 2004
Resolved 8 July 2004
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 July 2004 Resolved
Cover exposed space within stbd engine space panel box IAW 46 CFR 183.340.
Due 16 July 2004
Resolved 8 July 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 2 July 2004 Resolved
Prove proper operation of fixed fire fighting system for stbd engine space IAW 46 CFR 176.810(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2004
Resolution: Relay switch replaced and system test satisfactory to include alarms and shutdowns.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 26 December 2002 Resolved
Provide means of locking MSD overboard valve. LEGACY COMPONENT DESC: MSD Overboard Valve
Due 26 January 2003
Resolved 16 January 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 December 2002 Resolved
Repair or replace starboard engine RPM guage at pilothouse. LEGACY COMPONENT DESC: Starboard RPM Gauge at Pilothouse
Due 26 January 2003
Resolved 16 January 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 December 2002 Resolved
Provide a means of securing BMDEs at pilothouse. LEGACY COMPONENT DESC: Shutdowns at pilothouse
Due 26 January 2003
Resolved 16 January 2003
Engineering
Issued 19 November 2001 Resolved
Make permanent repairs to starboard main engine salt water cooling line in accordance with 46 CFR 182.422.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Vessel operator make permanent repairs to the stbd main engine.
Construction/Loadline
Issued 19 November 2001 Resolved
Provide handle for emergency escape hatch in the forward storage hold in accordance with 46 CFR 171.124.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Vessel operator provided a handle for the emergency escape hatch.
Lifesaving
Issued 19 November 2001 Resolved
Remove the stencil "Emergency Exit" on watertight doors leading to the forward void space.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Vessel operator provided a handle for the emergency escape hatch.
Fire Fighting
Issued 19 November 2001 Resolved
Prove proper operation of lower deck cabin smoke detectors in accordance with 46 CFR 176.810(a)(7). LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Due 3 December 2001
Resolved 3 December 2001
Resolution: Replace faulty smoke detectors in lower deck cabin.
Engineering
Issued 19 November 2001 Resolved
Make permanent repairs to starboard main engine exhaust manifold in accordance with 46 CFR 182.425.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Permanent repairs were made to the exhaust system on the stbd main engine.
Fire Fighting
Issued 19 November 2001 Resolved
Prove proper operation of fixed fire extinguishing controls in accordance with 46 CFR 181.420. LEGACY COMPONENT DESC: FFE Annual Inspection
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Fixed fire extininguishing systems was serviced.
Construction/Loadline
Issued 19 November 2001 Resolved
Provide lanyards for all hatch covers in accordance with 46 CFR 171.124. LEGACY COMPONENT DESC: Hatch Lanyards
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Resolution: Vessel operator provided lanyards for all hatches on vessel.
Documentation
Issued 28 September 1995 Resolved
POST ORIGINAL COI.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 28 September 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 3 ADDITIONAL RED AND 3 ADDITIONAL ORANGE DISTRESS SIGNALS.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CONFIRM THAT ADULT AND CHILD PFD'S ARE PROPERLY STOWED.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 28 September 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, MAKE PROPER REPAIRS AND PROVE PROPEROPERATION OF THE ELECTRICAL GENERATOR.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 28 September 1995 Resolved
PROVIDE BRACKET FOR B II EXTINGUISHER AT GAS GRILL.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 28 September 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROPERLY SERVICE B-II FIRE EXT FOR GAS GRILL.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 28 September 1995 Resolved
MASTER FAX STATEMENT TO MSOHONO ATTESTING TO THE SAT MEGGER READINGS, INSTALLATION IAW 46 CFR 183, 2 HOUR LOAD TEST, INSTALLED SHIP SERVICE DIESEL GENERATOR AND THAT ALL SYSTEMS ARE OPERATING PROPERLY AND PROVIDE TECHNICIANS REPORT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 28 September 1995 Resolved
PROVIDE CG-2692 FOR GENERATOR CASUALTY.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Electrical
Issued 2 September 1995 Resolved
FAILED MAIN GENERATOR. GENERATOR REPAIRED, REINSTALLED AND TESTED AS PER INSPECTION DEPT. REQUIREMENTS #4 & 8 OF CASE # MI95036400.
Condition: Unknown
Due 16 September 1995
Resolved 16 September 1995
Resolution: Replace generator and tested. All satisfactory.
Documentation
Issued 23 June 1995 Resolved
PROVIDE FCC SAFETY CERTIFICATE. UNTIL CORRECTED VESSEL IS RESTRICTED TO LESS THAN 1000 FEET FROM SHORE.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 23 June 1995 Resolved
PROPERLY MOUNT CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Fire Fighting
Issued 21 January 1995 Resolved
Install a Coast Guard approved fixed fire extinguishing and heat detection system in the machinery space in accordance with 46 CFR 181.20 and NVIC _x001C_ 6-72. Prove proper operation in the presence of a Coast Guard marine inspector.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 21 January 1995 Resolved
Post warning sings and instructions in the immediate vicinity of the gas BBQ grill.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 21 January 1995 Resolved
For the gas BBQ grill provide the following components: (1) A tank valve indicator which will indicate whether the valve is open or closed, and_x001C_ (2) Provide an in-line pressure gauge on the low pressure side of the pressure regulator.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 21 January 1995 Resolved
Conduct and log biweekly tests of the gas system on the BBQ grill.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Fire Fighting
Issued 21 January 1995 Resolved
Install a Coast Guard approved smoke detection system in both enclosed accommodation spaces. Prove proper operation in the presence of a Coast Guard marine inspector.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 21 January 1995 Resolved
Provide one additional B-II extinguisher in the immediate vicinty of the gas BBQ grill.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 21 January 1995 Resolved
Provide suitable fireproof decking or a catchment tray beneath the gas BBQ grill.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Fire Fighting
Issued 21 January 1995 Resolved
Show that the machinery space boundaries are lined with noncombustible insulation approved by 46 CFR 164.009.
Condition: Unknown
Due 21 January 1995
Resolved 21 January 1995
Accommodation/Occupational Safety
Issued 12 September 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 12 September 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 14 October 1993 Resolved
PROVE PROPER OPERATION OF ELECTRICAL OUTLET ON FORWARD SIDE OF PORT ENGINE ROOM FORWARD BULKHEAD, LOWER DECK.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Lifesaving
Issued 16 November 1992 Resolved
PROVIDE RETROREFLECTIVE TAPE AND APPLY IT PROPERLY TO ALL FOUR BUOYANT APPARATUS. THE VESSEL IS RESTRICTED TO OPERATIONS NOT MORE THAN ONE MILE FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Construction/Loadline
Issued 16 November 1992 Resolved
REPAIR THE MAIN DECK, WHERE FRACTURED, IN WAY OF THE AFT STARBOARD DECK CLEAT.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Accommodation/Occupational Safety
Issued 16 November 1992 Resolved
REPLACE THE CRACKED AND MISSING PLEXIGLASS WINDOWS IN THE MAIN PASSENGER ACCOMODATION SPACE AND THE DIVE SPACE, AFT OF THE MACHINERY SPACE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 16 November 1992 Resolved
CONDUCT UNDERWAY DRILLS WITH A MARINE INSPECTOR IN ATTENDANCE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Construction/Loadline
Issued 16 November 1992 Resolved
REINSTALL AND PROVE PROPER OPERATION OF THE ENGINE DRIVEN BILGE PUMP. VESSEL IS TO CARRY ONE ADDITIONAL PORTABLE 60 GPM PUMP UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Documentation
Issued 16 November 1992 Resolved
PROVIDE A CURRENT FCC OPERATOR'S CERTIFICATE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Fire Fighting
Issued 16 November 1992 Resolved
STENCIL VESSEL'S NAME ON THE FIRE AXE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Fire Fighting
Issued 16 November 1992 Resolved
PROVE PROPER OPERATION OF THE ELECTRIC FIRE PUMP.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Construction/Loadline
Issued 16 November 1992 Resolved
PROVE PROPER OPERATION OF THE ELECTRIC BILGE PUMP.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Lifesaving
Issued 16 November 1992 Resolved
STENCIL ALL CHILD'S LIFE PRESERVERS WITH VESSEL'S NAME.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Documentation
Issued 16 November 1992 Resolved
MAINTAIN THE ORIGINAL CERTIFICATE OF INSPECTION AND THE ORIGINAL CERTIFICATE OF DOCUMENTATION ON BOARD VESSEL.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Engineering
Issued 16 November 1992 Resolved
REPAIR THE LEAKS IN THE PORT SIDE WET EXHAUST MANIFOLD.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Construction/Loadline
Issued 16 November 1992 Resolved
SUBMIT PLANS TO THE LOCAL OCMI FOR APPROVAL OF THE INSTALLATION FOR THE SLIDE PLATFORM, PORT SIDE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Documentation
Issued 16 November 1992 Resolved
PROVIDE AND POST AN EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Documentation
Issued 16 November 1992 Resolved
PROVIDE PROOF OF COMPLIANCE WITH RANDOM DRUG TESTING REGULATIONS. FAILURE TO COMPLY WITH THESE REGULATIONS WILL RESULT IN THE REVOCATION OF THE VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 16 November 1992 Resolved
PROVIDE TWO WATER LIGHTS FOR TWO OF THE REQUIRED FOUR BUOYANT APPARATUS._x001C_ THE VESSEL IS RESTRICTED TO OPERATIONS NOT MORE THAN ONE MILE FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Fire Fighting
Issued 16 November 1992 Resolved
TEST THE FIRE HOSES.
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Lifesaving
Issued 16 November 1992 Resolved
STOW STARBOARD SIDE BUOYANT APPARATUS PROPERLY WITH WEAK LINK, AND LASH BOTH BUOYANT APPARATUS TO THE PAINTER. THE VESSEL IS RESTRICTED TO OPERATIONS NOT MORE THAN ONE MILE FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 16 November 1992 Resolved
REPLACE ONE OF THE BUOYANT APPARATUS SUSPECTED OF BEING WATERLOGGED (DEFECTIVE BUOYANT APPARATUS MARKED AND INDICATED TO VESSEL MASTER.) THE VESSEL IS RESTRICTED TO OPERATIONS NOT MORE THAN ONE MILE FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Electrical
Issued 27 December 1990 Resolved
PLACE A BLANK OR BREAKER IN THE OPEN SLOT ON THE SWITCHBOARD IN THE STARBOARD ENGINEROOM.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Electrical
Issued 27 December 1990 Resolved
REPLACE ALL WASTED BATTERY BOXES.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Navigation
Issued 27 December 1990 Resolved
PLACE ONBOARD A LARGE SCALE CHART OF THE VESSEL'S OPERATING AREA.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Construction/Loadline
Issued 27 December 1990 Resolved
LABEL ALL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Lifesaving
Issued 27 December 1990 Resolved
REPAIR THE SMALL TEAR IN THE BUOYANT APARATUS.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Lifesaving
Issued 24 January 1990 Resolved
CLEAN LIFEJACKETS AND RENEW ADHESIVE FOR RETROREFLECTIVE TAPE AS NEEDED ON ALL LIFEJACKETS.
Condition: Unknown
Due 24 January 1990
Resolved 24 January 1990
Electrical
Issued 12 February 1988 Resolved
REPAIR PORT MACHINERY SPACE VENTILATOR AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Fire Fighting
Issued 12 February 1988 Resolved
REPLACE 600 PSI NON-UL APPROVED FIREHOSE WITH A 1-1/2" FIREHOSE COMPLYING WITH THE REQUIREMENTS OF 46 CFR 181.15-10(D).
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
LABEL EMERGENCY FUEL SHUTOFF VALVES.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
LABEL FOREPEAK BILGE SHUTOFF VALVE.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 12 February 1988 Resolved
LABEL PERSONAL FLOATION DEVICE STOWAGE AREA.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
REPAIR STARBOARD MAIN ENGINE WATER TEMPERATURE GAUGE.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Unknown
Issued 18 February 1987 Resolved
DEMONSTRATE PROPER OPERATION OF THE PORT AND STARBOARD ENGINE EMERGENCY SHUTDOWNS LOCATED ON THE BRIDGE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Unknown
Issued 3 March 1986 Resolved
MAKE NECESSARY REPAIRS TO PORT AND STARBOARD MAIN ENGINE DIESEL FUEL FILTERS AND OIL FILTERS TO PREVENT DIESEL FUEL/ENGINE OIL FROM LEAKING INTOBILGES.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Unknown
Issued 3 March 1986 Resolved
PROVIDE A WATERLIGHT FOR ONE OF THE REQUIRED RING BUOYS.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Unknown
Issued 3 March 1986 Resolved
SERVICE VESSEL'S SEVEN PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Unknown
Issued 3 March 1986 Resolved
REMOVE ALL DISCONTINUED WIRING FROM STEERING LAZARETTE AND PORT AND STARBOARD FORWARD GEAR LOCKERS.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Construction/Loadline
Issued 23 April 1985 Resolved
INSTALL FINAL FIBERGLASS LAYER AND DECK COATING ON THE EXTERNAL AREAS OF DECK PLANKING IN WAY OF RENEWED DECK ABOVE THE FORWARD STAIRS AND PASSAGEWAY.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Electrical
Issued 23 April 1985 Resolved
INSTALL PERMANENT CABLE SUPPORTS AND SPLICE WIRING IN WAY OF FORWARD PASSAGEWAY REPAIRS.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985

Casualty record · 2

7 February 2004Routine · role: Involved in a Marine Casualty · activity 2025877
17 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2320236
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.