Inspection record

Last inspected 26 July 2024
…with no type recorded4
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9202326
WDE9213
472267
Flag
UNITED STATES
Maury page id
psix-472267

Documentation record

Registered dimensions (L × B × D)130.9 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.9 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 443 / net 132
BuilderBOLLINGER SHIPYARDS INC · LOCKPORT, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 May 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Net Ton
132 - Convention (Subpart B), Net Ton
551 - Dead Weight, Ton
90 - Regulatory (Subpart C or D), Gross Ton
443 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

26 July 2024 ORV Letter of Designation · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7967790
1 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7872689
26 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7856034
18 October 2023 Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7811045
29 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7658672
8 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7554451
2 August 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7555115
25 June 2021 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7235642
25 June 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7236017
5 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7168389
19 March 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7159071
23 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7013135
2 August 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6770376
4 April 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6385361
27 March 2018 Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6379373
3 March 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6366278
22 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6359614
19 June 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6180645
6 July 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5934194
28 March 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5842153
21 March 2016 Internal Structural Exam · Deficiency Check · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5842123

Deficiency record · 20

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 December 2023 No resolution recorded
Vessel shall be maintained in a safe and seaworthy condition. Vessel has an installed module on deck that is determined to be a Portable Accommodation Module (PAM) IAW CG-ENG Policy Letter 01-16 (PAM is an offshore lab where person(s) will take shifts to monitor equipment and readings) that has deficiencies in Electrical installation, Lifesaving, Fire Detection and fire-fighting equipment, Fire Hazards, and Working Conditions. During the inspection, the following was observed, but not limited to: The electrical wiring was using extension cords and splitters were interconnected ("daisy chained"). Module lacked fire detection, emergency lighting, emergency communication of the general alarm and PA system, and lifejackets. Flammable wooden shelving (2X4 and Plywood) were built into the module. Fire/Safety plan was not updated with the modules. Vessel's electrical system has been modified as Module and survey equipment is being powered by ship's electrical system with power cords being run from the top of the bridge down to the modules.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2023 Resolved
Fuel system piping including RACORs shall be steel, copper or nickel copper. Vessel did not have a metal bottom shell for the RACOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 18 October 2023
Resolution: Vessel rep emailed copy of invoice and picture of new installed RACOR bottom.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 October 2023 Resolved
Vessel shall remail watertight. Vessel had a top watertight penetration and QAWTD or ER Escape had loose dogs.
Action required: 10 - Deficiency Rectified
Resolved 18 October 2023
Resolution: Vessel corrected the watertight penetration and tightened the dogs for the WTD during the inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 June 2021 Resolved
A survey shall be made every time an accident occurs which affects the safety of the vessel. vsl was involved in a marine casualty causing damage. vsl shall be repaired in accordance with all regulations in applicable subchapters. vsl may movee to local shipyard for reparis upon notification of msu houma marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2021
Resolution: Repairs and NDT performed SAT witnessed by attending USCG MIs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2019 Resolved
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. vessel did not complete inspection within required timeframe. 46 CFR 126.510 17c
Action required: 10 - Deficiency Rectified
Due 2 August 2019
Resolved 2 August 2019
Resolution: COI inspection conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 August 2019 Resolved
No repairs or alterations may be made to the hull or machinery without notice to the cognizant OCMI in the inspection zone where the repairs are to be made.
Action required: 10 - Deficiency Rectified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Dye pen NDT conducted and verified by MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 August 2019 Resolved
Vessel must have adequate emergency lighting fitted along the line of escape to the main deck. Emergency lighting in the engine room and accommodations is inadequate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2019
Resolved 14 August 2019
Resolution: CIV S. Manning witnessed corrections to E-Lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2019 Resolved
Electrical installations on vessels must ensure protection of crew from electrical hazards. Main switchboard has an opening where the methanol breaker was installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2019
Resolved 14 August 2019
Resolution: CIV S. Manning verified blank installed on MSB.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2019 Resolved
Electrical installations on vessels must ensure maintenance of services necessary for safety under normal conditions. Light indicator on fuel oil service transfer pump is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2019
Resolved 14 August 2019
Resolution: CIV S. Manning witnessed operation of indicator light on F/O transfer pump motor controller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 August 2019 Resolved
Each propulsion control system operable from the pilot house must enable shutdown of each propulsion engine. Shutdowns currently malfunctioning.
Action required: 10 - Deficiency Rectified
Due 2 August 2019
Resolved 2 August 2019
Resolution: Replaced sticking emergency stop button.
Electrical › Electric Generation Source (service) › Generator
Issued 4 April 2018 Resolved
Clean generator windings (Port)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2018
Resolved 4 April 2018
Resolution: Generator windings cleaned, rep provided pictures and report from tech
Lifesaving › Inflatable Liferafts › Painter
Issued 4 April 2018 Resolved
Provide proper installation of liferafts. (painter lines not installed properly)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2018
Resolved 4 April 2018
Resolution: Painter lines installed properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 April 2018 Resolved
Replace line on lifebuoys at port wheelhouse light and handline on STBD O2 deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2018
Resolved 4 April 2018
Resolution: Replaced buoyant lifeline on both lifebuoys
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 June 2017 Resolved
Show proper operation of watertight doors and emergency escape hatch from engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 June 2017
Resolution: Replaced hatch and repaired door to satisfaction of attending ABS Surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 June 2017 Resolved
Remove oily bilge water from rudder room, show proper disposal reciept or proof.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 June 2017
Resolution: Proper removal and disposal was shown to attending Marine Inspector.
Stability › Unintentional Flooding › General
Issued 19 June 2017 Resolved
Vessel shall operate within ABS issued stability letter dated 19MAY2005.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 April 2018
Resolution: Reviewed logs, inspected rudder compartment and ensured vessel was operating IAW stability letter on 4APR18 Act # 6385361.
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 June 2017 Resolved
Show proper operation indicators for bus in engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 June 2017
Resolution: Extinguished buls were replaced, ground fault located and repaired in galley stove.
Lifesaving › Lifebuoys › Stowage
Issued 19 June 2017 Resolved
Install life buoy on stern of vessel.
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 20 June 2017
Resolution: Life buoy installed on stern
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 June 2017 Resolved
Replace "E" lighting on 02 deck.
Due 26 June 2017
Resolved 20 June 2017
Resolution: E lighting replaced.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 19 June 2017 Resolved
Repair fuel leak on manifold.
Due 26 June 2017
Resolved 20 June 2017
Resolution: Fuel Manifold leak repaired.