← All vessels
MISS ILLINOIS
MISS ILLINOIS is a 1998 towing vessel. The Coast Guard has recorded 30 inspections since 2002, most recently in April 2026, along with 16 deficiencies.
Records from 2002 to 2026. Most recent: inspection, 28 April 2026.
- Built
- 1998
- Last inspected
- 28 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1064642
WDI7292
472314
Flag
UNITED STATES
367727240
Maury page id
psix-472314
Inspections, by type
…with no type recorded1
Years with a record
23 calendar years (2002–2026)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 18.0 ft × 6.3 ft
Registered tonnagegross 45 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO, INC · GUILD TN · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Net Ton
45 - Simplified, Gross Ton
45 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI7292MMSI 367727240 · active · compulsorily equipped · granted 18 February 2026, expires 14 April 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
28 April 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8372236
21 January 2026
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8300019
1 August 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8173863
1 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7937209
9 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7738339
16 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7478990
12 March 2021
Initial Certification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7155202
21 July 2020
Spot Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7008918
6 January 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6883783
27 November 2019
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6864125
11 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6758152
4 May 2018
Spot Check (Safety) · Administration
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6417827
15 June 2017
Uninspected Other · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6178022
26 April 2016
Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5862421
19 August 2015
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5219563
10 March 2015
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5081418
10 July 2014
Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4922099
6 September 2013
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4717299
16 August 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4412499
16 June 2011
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4047930
9 June 2010
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3762681
19 June 2009
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3508073
14 December 2008
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3379756
1 July 2008
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3254624
5 June 2007
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2952312
28 July 2005
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2447699
20 April 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2344257
3 January 2005
Uninspected Other · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2267852
24 March 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2032040
7 February 2002
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1484774
Deficiency record · 16
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. When flanking rudder at hard to port, the port outboard rudder arm hits port flanking rudder stop with significant pressure to flex deck plate under rudder stop.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 August 2025
Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. Bilge and diesel fuel lines, listed on piping color key, were not clearly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2021
Resolved
For a vessel on which a new installation that is not a “replacement in kind” verification of compliance with the construction and arrangement design standards (noted in 46 CFR 144) must be performed before the new installation is performed. New installation of radar and AIS, class A device, completed prior to completion of verification of compliance. Vessel may continue operating within route restrictions noted on COI until a copy of the radar/AIS installation plan (verified as per 46 CFR 144.145(d)) is provided to the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2021
Resolved
Engine alarm required to continue until acknowledged. Generator oil pressure and coolant temperature alarms unable to be acknowledged. Correct alarm system to include capability to acknowledge alarms.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 12 August 2021
Resolved
Each operator must hold a restricted (radio) operator's license or higher. The vessel master was unable to provide their radio operator's license. Make license available for exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 July 2019
Resolved
Vessel generator required to be equipped with a RPM gauge. Generator was not equipped with an RPM gauge. Properly install an RPM gauge on the generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2019
Resolved
Hydraulic, cooling, and fuel piping: required to be color coded or valves labeled. Labels were missing or unreadable on several valves. Replace labels or properly color code piping.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 July 2019
Resolved
Hydraulic steering ram for starboard rudder leaking hydraulic fluid at stern of vessel. Properly repair steering ram to secure leak.
Engineering › Fuel Oil Service System › Hose
Issued 15 June 2017
Resolved
Starboard main diesel engine fuel oil return line wept (leaked) fuel at union of check valve and non-metalic pipe (hose) located just aft of forward engine room bulkhead.
Engineering › Pressure Vessel › Safety Valve
Issued 15 June 2017
Resolved
At time of exam, unable to determine whether or not vessels (2) air receivers were protected with properly sized safeties. Vessel operator to prove properly sized safeties are installed.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 June 2017
Resolved
Port main diesel engine RPM gauge at operator station did not work.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 July 2008
Resolved
Valid COD not availble for inspection.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 February 2002
Resolved
Vessels remote fuel shut off system is missing the required labeling. LEGACY COMPONENT DESC: Lables
Communications › Alarms/Indicators › General Alarm
Issued 7 February 2002
Resolved
Vessels general alarm is missing the required labeling.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 February 2002
Resolved
Vessels fire detection system is missing the required certification from a Registered Professional Engineer.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 February 2002
Resolved
Vessels fire detection control panel is missing the required labeling indicating the location/origin of fire.