Inspection history · 51
28 April 2026
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8371929
1 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8173877
1 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7937203
9 August 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7736101
22 June 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7478997
18 March 2021
Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7153725
21 July 2020
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7008914
11 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6685677
5 April 2018
Examination of Repairs · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6389078
8 February 2018
Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6351987
12 June 2017
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6168314
25 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6155098
26 April 2016
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5853454
26 January 2016
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5803775
31 August 2015
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5231355
26 August 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5227106
18 August 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5219882
25 June 2014
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4899425
21 November 2013
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4756824
3 September 2013
Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4704381
25 June 2013
Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4631620
16 August 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4403611
16 June 2011
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4028673
4 June 2010
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3757514
19 June 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3512971
27 October 2008
Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3352421
1 July 2008
Administrative Inspection · Annual Inspection · Drydock Extension
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3235136
11 March 2008
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162358
12 April 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2906820
25 July 2006
Excursion Permit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2724348
22 June 2006
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2688356
15 March 2006
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2603263
2 August 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2448688
27 July 2005
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2400770
16 November 2004
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2242016
18 June 2004
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2103066
23 July 2003
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1839629
22 July 2003
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1854250
8 July 2003
Hull Examination · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1822271
12 August 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1658513
24 July 2002
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1643959
3 July 2001
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435236
26 September 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1054316
10 July 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1421901
30 July 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1110002
7 July 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460323
17 November 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 806458
1 September 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 801994
25 August 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 798460
12 August 1998
Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 796257
7 July 1998
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1433360
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 August 2021
Resolved
Vessel required to have a approved first aid kit or equivalent. First aid kit on board ferry contained expired supplies. New first aid kit, with contents within expiration dates, placed on board by the end of the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 12 August 2021
Resolution: New kit placed on board ferry.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 August 2021
Resolved
Vessel required to have 3 life ring buoys. One buoy was worn beyond service life and taken out of service. New buoy placed on board by the end of the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 12 August 2021
Resolution: Life ring buoy replaced with new buoy.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 August 2021
Resolved
Vessel required to have an emergency broadcast cast placard. Ferry did not have a placard posted at operator's station. Placard on board by the end of the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 12 August 2021
Resolution: Placard placed on board ferry.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 July 2019
Resolved
Emergency broadcast placard required to be posted in vicinity of vessel radio. Placard not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 11 July 2019
Resolution: Proper emergency broadcast placard posted by the end of the inspection.
Electrical › Electrical Distribution System (service) › Conductor
Issued 26 April 2016
Resolved
Connection in conductor was not made within an enclosure as per 46CFR183.340. Proper connection required.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 3 May 2016
Resolution: Vessel operator properly made connection within enclosure.
Fire Fighting › Fire Pumps › Arrangement
Issued 19 August 2015
Resolved
Fire pump discharge piping is fitted with a small (10") flexible hose on the dischagre side of the pump.
Action required: 705 - Other - as specified
Due 19 September 2015
Resolved 21 August 2015
Resolution: Receieved email notification, with photos, identifying that the flexible hose on discharge side of fire pump had been replaced with rigid, metallic piping.
Operations/Management › Passenger Operations › Safety Orientation
Issued 10 July 2014
Resolved
Update sign showing location of life saving equipment with current information.
Action required: 705 - Other - as specified
Due 10 August 2014
Resolved 15 July 2014
Resolution: Vessel rep provided report and photos showing updated sign installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 July 2014
Resolved
Renew electrical cable in vicinity of barge/tow vessel interface at point where cable enters hull of barge.
Action required: 705 - Other - as specified
Due 10 August 2014
Resolved 15 July 2014
Resolution: Vessel rep provided report and photos showing new electrcial cable installed.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 21 May 2007
Resolved
Life ring and a light for a life ring were unserviceable.
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: Items removed from vessel and replaced with serviceable equipment.
Construction/Loadline › Structures › Superstructure
Issued 15 March 2006
Resolved
Submit proper plan approval to CG MSO St. Louis from a certified professional engineer for your newly installed tow coupling lifting post, proving strength, affects on vessels stability, and any other factors it may have on the vessels hull or coupling prior to future use.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 2 May 2006
Resolution: Engineering report submitted.
Documentation › Logs/Records › Logbook (official)
Issued 27 July 2005
Resolved
Keep ashore a passenger count I.A.W 46 CFR 185.504
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 August 2005
Resolved 8 November 2005
Fire Fighting › Fire Hoses › Condition
Issued 23 July 2003
Resolved
Replaced fire hose due to a failure of the hoses jacket.
Condition: Improper/Lack of Maintenance
Due 23 July 2003
Resolved 23 July 2003
Engineering › Bilge Water Management System
Issued 24 July 2002
Resolved
Remove all debris from voids which could clog bilge suction strainers in the event of an emergency. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 24 August 2002
Resolved 12 August 2002
Engineering
Issued 3 July 2001
Resolved
Prove proper operation of volt gauges in pilot house.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Construction/Loadline
Issued 3 July 2001
Resolved
Repair or replace pressure gauge on bilge pump.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Engineering
Issued 3 July 2001
Resolved
Properly secure engine gauges.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Construction/Loadline
Issued 3 July 2001
Resolved
Install portable hand bilge pump.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Electrical
Issued 3 July 2001
Resolved
Prove proper operation of AMP gauge on generator.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Engineering
Issued 3 July 2001
Resolved
Repair or replace bracket on Port engine Air intake.
Condition: Unknown
Due 31 July 2001
Resolved 1 August 2001
Deck/Cargo
Issued 10 July 2000
Resolved
RENEW ALL BARGE RAMP AIR HOSES
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Deck/Cargo
Issued 10 July 2000
Resolved
MOUSE ALL HOOKS ON ANCHOR RIGGING
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Navigation
Issued 10 July 2000
Resolved
REPAIR HYDRALIC LEAK ON TOW BOAT STEERING FILTER.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Lifesaving
Issued 7 July 1999
Resolved
Prove proper operation of tow vessel waterlight.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Construction/Loadline
Issued 7 July 1999
Resolved
Remove excess oil/rags from tow vessel bilge.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Engineering
Issued 7 July 1999
Resolved
Remove fuel from filling station overfill.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Electrical
Issued 7 July 1999
Resolved
Install globe and guard on deck light fixture.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Documentation
Issued 7 July 1999
Resolved
Mount marpol and garbage placards.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Fire Fighting
Issued 7 July 1999
Resolved
Provide proof of fire extinguisher servicing.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Fire Fighting
Issued 25 August 1998
Resolved
Ensure fire & bilge pumps are interconnected, or provide one additional bilge pump. Ensure bilge pumps produce 50 GPM, as per 46 CFR 182.520(a).
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Fire Fighting
Issued 25 August 1998
Resolved
Prior to getting underway with passengers, ensure fire pump produces 50 GPMat 60 PSI, as per 46 CFR 181.300(b).
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Lifesaving
Issued 25 August 1998
Resolved
Install approved first aid kit, as per 46 CFR 184.710
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Fire Fighting
Issued 25 August 1998
Resolved
Ensure safe access to fire main sea chest valve.
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Construction/Loadline
Issued 25 August 1998
Resolved
Provide audible & visual high water alarm for bilge space with through hullfitting. Alarm must sound at operator station, as per 46 CFR 182.530(c)(i).
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Lifesaving
Issued 7 July 1998
Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Lifesaving
Issued 7 July 1998
Resolved
PROVIDE EVIDENCE OF SATISFACTORY COMPLAINCE WITH DRUG TESTING REQUIREMENTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998