← All vessels
SUPER QUEEN
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named SUPER QUEEN
SUPER QUEEN is a 1972 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1985, most recently in May 2026, along with 166 deficiencies, 1 operational control and 7 casualty investigations between 2008 and 2022.
Records from 1985 to 2026. Most recent: inspection, 13 May 2026.
- Built
- 1972
- Last inspected
- 13 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 166 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 7 investigations · 2008–2022
Identity
541178
WAO9076
47232
Flag
UNITED STATES
367056010
Maury page id
psix-47232
Inspections, by type
…with no type recorded12
Years with a record
40 calendar years (1985–2026)
The 94 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)75.1 ft × 32.0 ft × 9.4 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMONARK CUSTOM CRAFT INC · JEANERETTE, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 21 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WAO9076MMSI 367056010 · active · compulsorily equipped · granted 19 August 2025, expires 21 September 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 94
13 May 2026
Deficiency Check · Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8357982
16 September 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8235638
25 February 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8073830
23 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7861297
19 October 2023
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7806217
10 July 2023
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7738622
31 May 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7694972
21 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7633160
21 December 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7613512
25 April 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7422180
25 October 2021
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7326389
9 April 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7171921
21 July 2020
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6991834
31 October 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6808501
23 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6725983
15 May 2018
Administrative Inspection · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6394636
13 November 2017
Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6310078
10 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6305985
2 November 2017
Welding Related Inspections Qualification Testing · Examination of Repairs · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6299541
20 April 2017
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6100238
26 July 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5953506
8 October 2015
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5738686
21 July 2015
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5190487
27 May 2014
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4870865
26 May 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4873681
1 May 2012
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4299260
1 August 2011
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4102017
30 July 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4210775
10 February 2009
Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3423066
13 November 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3362907
22 July 2008
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3275955
7 July 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3260845
14 March 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3195887
24 September 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3065461
8 May 2007
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2924869
13 February 2007
Examination of Repairs · Hull Examination · Drydock Extension
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2871278
16 August 2006
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2748384
9 August 2005
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2455638
17 February 2005
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2295221
22 December 2004
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2271753
5 August 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2156000
24 June 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1826062
29 May 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1798170
8 November 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1694104
21 June 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1636894
16 May 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1614473
19 June 2001
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1425151
8 August 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1052744
27 June 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408559
18 May 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 810247
18 May 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386576
24 November 1998
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468016
6 July 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399063
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 780762
22 July 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464738
3 June 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464737
23 April 1997
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368201
22 May 1996
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1388054
21 September 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191160
30 August 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 875428
12 June 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664420
23 May 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 878242
2 May 1995
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210448
18 August 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 84987
15 June 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960399
25 May 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170342
27 May 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146294
12 May 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152413
3 June 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 948824
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937647
26 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1245973
17 June 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351736
12 June 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1194174
17 September 1990
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 922686
6 September 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899808
11 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900387
19 June 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214956
21 February 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1237493
16 June 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200671
8 August 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343236
17 June 1988
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208695
13 May 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1205621
20 October 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1323202
2 September 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1323860
22 June 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029633
30 April 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1016742
6 March 1987
Drydock Extension
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1321687
28 October 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023447
26 September 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1316003
25 June 1986
COI Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994738
2 June 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302065
25 July 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 985003
24 June 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 977972
7 June 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 978501
Deficiency record · 166
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 13 May 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. During inspection of port engine room with engines running and underway, inspector’s 4 gas meter alerted for high levels of H2S and CO. Determine cause and affect repairs so an operational test of port engine room can be completed.
46CFR177.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
A vessel of more than 19.8 meters (65 feet) in length
must carry a minimum of three life buoys. One life buoy
was in deteriorated, unserviceable conditions and must
be replaced.
46CFR180.70
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 May 2026
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Each hatch exposed to the weather must be watertight. FWD starboard hatch cover gasket was not watertight and must be replaced.
46 CFR 177.13-1 OLD T; 46 CFR 171.124 (a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2026
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except:(1) As allowed under Sections 400.10 and 400.12 of NFPA 70. Uses Not Permitted (400.12) Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: As a substitute for the fixed wiring of a structure...Where run through doorways, windows, or similar openings. Freezer on aft deck must be permanently wired or removed.
46 CFR 183.340(r)
46 CFR 111.60-13(b)(1)
NFPA 70 Section 400.12
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 May 2026
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Master must provide valid medical certificate.
46CFR10.301
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 February 2025
Resolved
Each buoyant apparatus on the vessel before March 11,
1996 may be used as long as its in good and serviceable
condition.
It was deemed that the one of the 4 buoyant apparatus
has reached the end of its serviceable life and shall be
replaced with a life float meeting 46CFR160.027.
46 CFR 180.15
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2025
Resolved
The vessel must have on board a number of child size
life jackets equal to at least 10% (16) of the number of
persons permitted.
The vessel only had on board 15 of the 16 required child
life jackets. Vessel operations are limited to 15
persons under 90lbs until the additional child life
jacket is on board and labeled.
46 CFR 180.71
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 February 2025
Resolved
Each life float and buoyant apparatus shall be fitted
with lifelines and pendants.
The life lines and pendants on the buoyant apparatus'
are deteriorated and dry rotting. Replace with new dark
colored synthetic line.
46 CFR 180.175
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 February 2024
Resolved
In the design of a control, interlock, or indicator circuit, the disconnect device and its connections, including each terminal block for terminating the vessel's wiring, must not have any electrically unshielded or uninsulated surfaces.
MI Observed an open section in the distribution panel.
46 CFR 183.330
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
MI Observed multiple dead in wires in the engine machinery space.
46 CFR 183.200
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 February 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material.
MI observed the globe in the emergency light in the engine room to not be a high strength material.
46 CFR 183.410
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2023
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
MI observed port emergency fuel shut off valve was leaking fuel into the bilge.
46 CFR 176.25-50
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2023
Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
MI observed starboard emergency fuel shut off valve was leaking fuel into the bilge.
46 CFR 176.25-50
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where the neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus. The neutral bus shall be connected to ground. If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This ground connection must be at the switchboard or at the common ground plate, which must be accessible.
The neutral for the dual voltage generator is not connected to the ground at the switchboard. The dual voltage generator is not grounded presenting an electrocution hazard to all persons onboard.
46 CFR 183.376 and 46 CFR 183.10-30
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023
Resolved
Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor IAW 46 CFR 183.370.
The generator ground is not installed in the distribution panel and the distribution panel does not have a ground bus bar or grounding conductors to each electrical outlet/device powered by AC current throughout the entire vessel which presents an electrocution hazard to all persons onboard.
46 CFR 183.10-20 and 46 CFR 183.370
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023
Resolved
The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus.
Ground detection must be provided that: For an alternating current system, meets § 111.05-27 in subchapter J of this chapter.
Ground fault detection is not installed at the switchboard.
46 CFR 183.10-30 and 46 CFR 183.324
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023
Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc., shall be drip proof protected. Drip proof protected means that equipment and machinery is so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt, and rotating or uninsulated parts cannot be inadvertently touched or approached nearer than a safe distance by any person. Switchboards shall be fitted with drip hoods and hand
rails. Non-conducting mats or grating shall be provided on deck in front and rear of switchboards.
The 240V switchboard was found without an enclosure or drip shield. The equipment is open in the back, bottom, sides and top and all live conductors can be touched by the crew.
46 CFR 183.10-10 and 46 CFR 183.330
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 21 February 2023
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. All wiring shall be installed as high as possible above the bilge.
Welding cable found installed between battery installations in the port/stbd hull. Welding cable is connected to each battery system between the cross deck of the catamaran hull. Welding cable does not have an adequate thermal plastic to protect the conductor from heat due to resistance and presents a fire hazard. Replace with Marine Grade electrical conductors rated for the current carrying capacity of the electrical load. The starboard generator starting conductor and negative conductor were found installed in the bilge.
46 CFR 183.10-20 and 46 CFR 183.340
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 February 2023
Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required,
but are installed, the system or equipment and its installation shall meet the requirements of this Part.
The vessel is outfitted with two fire pumps on each engine in each separate hull. The starboard fire pump belt drive was found cracked and damaged making the unit inoperable. The port fire pump operated as intended.
46 CFR 181.05-5
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 February 2023
Resolved
Except where all or a part of the emergency instructions are deemed unnecessary by the Officer in Charge of Marine Inspection the emergency checkoff list shall contain not less than the applicable portions of the Recommended Emergency Checkoff List §185.25-5. Fire at sea. (1) Cut off air supply to fire-close hatches, ports, doors, and ventilators, etc.
The engine room fire damper closures are constructed of fiberglass for this aluminum vessel. The port damper closing hatch was found damaged and does not cover the damper. Fire damper construction should match the construction material of the vessel.
46 CFR 185.25-1
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 February 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
18 adult life jackets were found damaged and destroyed by the crew.
Passenger count reduced to 135 plus 3 crew.
46 CFR 180.71
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2022
Resolved
EPIRB installation must be a float free arrangement.
The Hydrostatic release is expired
46 CFR 180.64
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2022
Resolved
Portable fire extinguishers must be maintained and inspected in accordance with NFPA 10.
Vessel did not have a record of monthly checks on their extinguishers.
46 CFR 176.810(b)(1)
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 May 2021
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or many overboard conditions. Vessel did not have emergency instructions written or posted on board.
46 CFR 185.510 (a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2021
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. 02 portable extinguishers, meant to protect accommodation space on main deck, were found to be stored in closet with no brackets to secure from movement.
46 CFR 181.520
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2021
Resolved
The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge was stuck at 40psi. MI verified that pressure and discharge did increase despite gauge remaining at 40 psi.
46 CFR 181.300 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 May 2021
Resolved
Each buoyant apparatus on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition. 01 buoyant apparatus found to have resin failure. Passenger count reduced to 120 until chosen to repair or replace.
46 CFR 180.15 (b)
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 May 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. While conducting man overboard drill, the crew experienced difficulty communicating and identifying respective responsibilities to retrieve the man in the water. At one point, no crew member had eyes on the man in the water. The master could not see and was not receiving directions from the crew.
46 CFR 176.808 (g)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 May 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Kit had expired ammonia inhalants, aspirin, and eye wash.
46 CFR 184.710
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 May 2021
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel’s stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 2 mm (1 inch) numbers and letters at the entranceway to that deck. Maximum passengers allowed on upper deck was not found at the entranceway to that deck.
46 CFR 185.602 (g)
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 11 May 2021
Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. Vessel printed out Garbage Management Plan while MI was on board. Plan meets requirements in accordance with 33 CFR 151.57.
46 CFR 184.702
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 May 2021
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side. Hatches identified as emergency escapes routes were over-tightened and unable to be opened by one person from inside the space. Crew members loosened handles to allow persons inside the space to be able to open.
46 CFR 177.500 (h)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2021
Resolved
Protection must be approved in compliance with 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. MI found small portion of dry exhaust pipe exposed. Crew member repaired insulation to prevent future injuries.
46 CFR 182.430 (a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2021
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. MI found 03 adult life jackets and 02 child life jackets with deteriorated retroreflective material. Crew members replaced retroreflective material on the life jackets identified.
46 CFR 185.604
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 July 2019
Resolved
Safety Radiotelephony Certificate expired. Provide a valid Safety Radiotelephony Certificate. 46 CFR 184.502
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2019
Resolved
Replace plastic piping arrangement with metallic shut off valve at hull penetration in both engine rooms. 46 CFR 182.520
Engineering › Bilge Water Management System › Valve
Issued 15 May 2018
Resolved
Replace wasted bilge / fire cross over valve port side as original. Provide proposal for use of non-metallic piping in bilge system or replace flex hose metallic piping as original. 46 CFR 182.710
Construction/Loadline › Structures › Superstructure
Issued 15 May 2018
Resolved
Replace cracked glass window port side main deck using safety glazing materials IAW 46 CFR 177.1020
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 May 2018
Resolved
Electrical equipment on a vessel must installed and maintained to minimize accidental personnel contact with energized parts. Replace missing breakers in pilot house panel. 46 CFR 183.200(e)
Construction/Loadline › Hull › Hull Plating
Issued 13 November 2017
Resolved
Repair pinhole prior to carrying passengers IAW 46 CFR 176.610.
Construction/Loadline › Hull › Weld
Issued 6 November 2017
Resolved
Found cracked weld at fore peak tunel area, grind down and re-weld to the satisfaction of the attending marine inspector. 46CFR177.300(d)
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 April 2017
Resolved
Found 24 adult lifejackets in not serviceable condition, replace with 24 adult lifejackets in good serviceable condition to the satisfaction of attending marine inspector. Persons count reduce to 124.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 April 2017
Resolved
Radar dome found cracked at support bracket, repair to the satisfaction of attending marine inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017
Resolved
Found nav lights not in compliance with UL1104, replace with appropriate type to the satisfaction of the attending marine inspector. Restricted to day time only.
Construction/Loadline › Structures › Door
Issued 25 April 2017
Resolved
Found starboard side engine watertight door with a broken handle, repair to the satisfaction of attending marine inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 25 April 2017
Resolved
Main dry exhaust systems found with broken lagging, repair or replace to satisfaction of marine inspector. 46 cfr 176.25-10
Engineering › Bilge Water Management System › Not Operational
Issued 25 April 2017
Resolved
Bilge pump manifold system not functioning on stbd side at engine room and aft stern. make repairs as needed and prove proper operation.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 July 2016
Resolved
Vessel is restricted to carry 14 children until 2 more PFDs are provided iaw 46 CFR 180.71(b).
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 26 July 2016
Resolved
FCC Bridge to Bridge certificate is not onboard and not valid for vessel iaw 47 CFR 80.1101.
Fire Fighting › Fire Main › Condition
Issued 26 July 2016
Resolved
Fire main piping has 2 pinhole leaks in each side and must be repaired or replaced prior to operation iaw 46 CFR 81.314.
Fire Fighting › Fire Pumps › Pressure
Issued 26 July 2016
Resolved
Main Fire Pump not operating iaw 46 CFR 181.300.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 July 2016
Resolved
Emergency fuel shutoff valve tested with fuel leaking at valve stem iaw 46 CFR 182.455(b)(4).
Accommodation/Occupational Safety › Heating › Piping
Issued 26 July 2016
Resolved
Stbd engine exhaust pipe needs to be replaced iaw 46 CFR 182.425.
Stability › Watertight Integrity › General
Issued 26 July 2016
Resolved
Stuffing tubes on port and stbd side need to be replaced iaw 46 CFR 182.40-1.
Electrical › Lighting (service) › Conductor
Issued 26 July 2016
Resolved
Loose wiring needs to be addressed in port engine room iaw 46 CFR 176.806.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 26 July 2016
Resolved
Loose connections on port battery 46 CFR 176.806(f).
Construction/Loadline › Structures › Deck Plating
Issued 8 October 2015
Resolved
Crop and renew deck plating at least as marked on port fore peak/super strucutre connection weld. 46CFR 176.600
Construction/Loadline › Hull › Weld
Issued 8 October 2015
Resolved
Grind ans re-weld three broken welds on STBD/PORT fore peak overhead. 46CFR 176.600
Engineering › Fuel Oil Service System › Valve
Issued 21 July 2015
Resolved
Fuel shut off valves must be labeled with lettering at least 1" in height. 46CFR185.608
Electrical › Electrical Distribution System (service) › Cable
Issued 21 July 2015
Resolved
Wiring in both engine rooms must not have wire ties to support them. Support with insulated clamps. 46CFR183.340(b)(4)
Engineering › Lubricating Oil Service System › Cooler
Issued 27 May 2014
Resolved
Reduction gear oil cooler inoperable and leacking oil. 46CFR182.220
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 April 2013
Resolved
Crop and renew indentation at cabin access door leading edge on door bottom threshold, to eliminate knife edge hazard to crew and passengers. IAW 46 CFR 177.800(c).
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 May 2012
Resolved
Port side fwd eng rm junction box overhead needs plug. IAW46CFR183.340.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 May 2012
Resolved
Port side aft eng rm overhead junction box wires need proper connection & cover. IAW46CFR183.340.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 May 2012
Resolved
Port/Starboard emergency exit at eng rm need to be operable and labeled at both sides. IAW46CFR177.500 and 46CFR185.606.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2012
Resolved
Starboard side aft eng rm light fixture needs to be mounted properly. IAW46CFR193.05-50
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 May 2012
Resolved
Stbd side eng rm overhead penetration for head pipe needs replacement. IAW46CFR182.40-1(a)(1)(i)
Documentation › Markings/Placards › Capacity Marking
Issued 1 May 2012
Resolved
Properly label second deck passenger capacity IAW Stability Letter (80). IAW46CFR183.602(g) and 46CFR160.062.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 July 2008
Resolved
Circuit Breaker panel on stbd-aft 01 deck IWO galley missing labels for circuits.
Construction/Loadline › Structures › Door
Issued 7 July 2008
Resolved
Approx 6 J-bolts were found missing from two aft tonnage doors on the 01 deck. Vsl required to install missing J-bolts.
Fire Fighting › Fire Hoses › Connections
Issued 7 July 2008
Resolved
Stbd fire hose was found w/ improper connection fittings on both the hydrant and nozzle sides; vsl to make proper repairs or replace hose.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 July 2008
Resolved
07 pfd's were found in not-ready condition in regards to connection fittings/straps, labeling, and retro-reflective tape. Vsl to make proper repairs to all pfd's.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 July 2008
Resolved
Vsl missing required draft markings IAW the vsl's stability letter; vsl required to affix draft markings by the end of their next drydocking date.
Stability › Watertight Integrity › General
Issued 7 July 2008
Resolved
Void space hatch door on aft stbd side IWO stbd lazarette was found to be fractured; vsl to make proper repairs or replace watertight hatch prior to operation.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 July 2008
Resolved
At next drydock, make permanent repair to 4 fractures in the stbd lazzerette in way of the port & stbd longitudinal deep web frames. Monitor the fractures weekly and report any changes to the cognizant OCMI immediately.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 May 2007
Resolved
Provide machinery guards for PORT & STBD main engines to protect pulley and belt for fire/bilge pumps as discussed. Pulley assembly has a half shield leaving the PTO pulley exposed on both engines.
Stability › Watertight Integrity › General
Issued 8 May 2007
Resolved
Renew gasket on PORT and STBD engine room door. They have used improper combing gasket material, which is falling off.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 May 2007
Resolved
Repair water tight door alarm on PORT engine room door. While U/W, engine room doors must remain closed with a alarm on the bridge to notify the master that the door is open.
Fire Fighting › Fire Pumps › Pressure
Issued 8 May 2007
Resolved
Replace fire pump gauge. Ample pressure in system, but gauge is OOC.
Stability › Weathertight Integrity › General
Issued 8 May 2007
Resolved
Repair fractures in the main deck and super structure IWO the FWD PORT and STBD corners where the super structure and the deck meet. Found small stress cracks.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 16 August 2006
Resolved
Prior to the carriage of passengers, repair water leak on STBD engine, inboard FWD as discussed. While engine RPM's are increased, water was streaming out form a rubber hose connection from the block to the expansion tank.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 16 August 2006
Resolved
Prior to the carriage of passengers, repair oil leak on PORT engine, inboard AFT breather cap. Side breather cap was blowing out exhaust and oil mist while running.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 16 August 2006
Resolved
Prior to the carriage of passengers, repair water leak on PORT engine, outboard AFT.
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 16 August 2006
Resolved
Clean up oil on engines and determine and/or repair oil leaks. They had oil on top of engine between blowers and down along the side of block.
Engineering › Bilge Water Management System › Valve
Issued 16 August 2006
Resolved
Prior to the carriage of passengers, repair reach rod to bilge valve connection in STBD FWD void.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 9 August 2005
Resolved
Provide proof of MIS report submission by consortium IAW 46CFR16.500. They had last years report, but the POC claimed he never got a copy this year. He called consortium while onboard and left a message with agent.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2005
Resolved
Update first aid kit. Several items were past the expiration dates.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 August 2005
Resolved
Label amount and style of life preservers stowed on the upper deck. They had no signage what so ever on the life preserver stowage locker.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 August 2005
Resolved
Post donning placards through out vessel. They had no donning placards posted.
Lifesaving › Lifefloat › Markings
Issued 9 August 2005
Resolved
Replace retro-reflective tape on the bottom two life floats as discussed. Tape was worn off.
Lifesaving › Lifebuoys › Approval
Issued 9 August 2005
Resolved
Replace STBD ring buoy and provide retro-reflective tape for PORT ring buoy. STBD buoy had several small cuts in ring.
Engineering › Bilge Water Management System › Piping
Issued 9 August 2005
Resolved
Prove proper operation of the installed bilge piping cross over system. Failed to take a vacuum from the PORT FWD void, utilizing the STBD bilge pump. Same happened when system were reversed. The pump would start to create a vacuum, but then lose it's prime. Both pumps work properly, but just can't draw a vacuum when the cross over vale is opened.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 August 2005
Resolved
Replace cracked FWD window on bridge as discussed.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 9 August 2005
Resolved
Provide covers for the engine room vents as discussed. At this time, they have no means of securing ventilation in a timely manner.
Engineering › Bilge Water Management System › Pump
Issued 9 August 2005
Resolved
Provide a 5 GPM hand held bilge pump. The pump onboard did not work.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2004
Resolved
REPAIR 24 VOLT EMERGENCY LIGHTING IWO STARBOARD ENGINE ROOM.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 August 2004
Resolved
REPLACE RETRO TAPE AND SNAPS ON LIFEJACKETS AS IDENTIFIED.
Construction/Loadline › Structures › Manhole
Issued 5 August 2004
Resolved
INSTALL BREAKER BARS IN VICINITY OF ESCAPE HATCHES.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 May 2003
Resolved
Repair oil leaks on both MDE's in way of old PTO cover plate, and on the PORT engine, in way of the oil lines forward of the oil filter. LEGACY COMPONENT DESC: PTO cover
Fire Fighting › Fire Hoses › Condition
Issued 29 May 2003
Resolved
Prior to the carriage of passengers, repair PORT fire hose nozzle connection.
Lifesaving › Lifejacket/PFD (General)
Issued 29 May 2003
Resolved
Repair or replace 12 adult and 5 child sized Type I lifejackets. (Buckles and/or retro-reflective material) Passenger count reduced to 138 until completed. LEGACY COMPONENT DESC: Condition
Communications › Radio Communications
Issued 29 May 2003
Resolved
Update FCC Radiotelephone Safety Certificate. LEGACY COMPONENT DESC: FCC safety cert
Engineering › Bilge Water Management System
Issued 29 May 2003
Resolved
Label high bilge level alarm panel. LEGACY COMPONENT DESC: Alarm panel
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Replace retro-reflective tape on BA's as needed prior to the carriage of passengers. LEGACY COMPONENT DESC: BA''s retro
Engineering › Bilge Water Management System
Issued 16 May 2002
Resolved
Remove flex hose from bilge piping system. Both hulls contains sections of pipe that are connected by flex hose. Correct during next drydocking of vessel. LEGACY COMPONENT DESC: Piping
Lifesaving › Buoyant Apparatus
Issued 16 May 2002
Resolved
Replace worn/frayed lifelines on all buoyant apparatus. Replaced line must be installed IAW approved procedures contained in 46CFR subchapter Q.
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 May 2002
Resolved
Replace/repair to serviceable condition 15 Adult Type I lifejackets. Vessel's COI is reduced to 140 total persons until this CG-835 has been cleared by the attending Marine Inspector. LEGACY COMPONENT DESC: Condition
Lifesaving
Issued 19 June 2001
Resolved
REPAIR/REPLACE 8 ADULT TYPE I LIFE JACKETS. PASSENGERS REDUCED TO 142 UNTIL COMPLETION.
Documentation
Issued 19 June 2001
Resolved
PROVIDE COPY OF CURRENT CONSORTIUM CONTRACT AND CREW LIST.
Lifesaving
Issued 19 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, SECURE HOT PLATE IN GALLEY.
Construction/Loadline
Issued 19 June 2001
Resolved
PRIOR TO CARRIAGE OF PASENGERS, REPAIR STBD FOREPEAK REACH ROD. _x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 19 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, REPAIR MAIN BILGE PUMP. _x001C_ _x001C_ _x001C_
Lifesaving
Issued 27 June 2000
Resolved
REPLACE 13 ADULT LIFEJACKETS. TOTAL PASSENGERS REDUCED TO 137 UNTIL COMPLETION.
Electrical
Issued 27 June 2000
Resolved
INSTALL BLANK IN PORT DISTRIBUTION PANEL.
Lifesaving
Issued 27 June 2000
Resolved
REMOVE COMBUSTIBLE MATERIALS FROM STBD FOREPEAK PRIOR TO CARRIAGE OF PASSENGERS.
Unknown
Issued 27 June 2000
Resolved
POST PLACARD ON UPPER DECK STATING MAXIMUM PASSENGERS ALLOWED.
Lifesaving
Issued 27 June 2000
Resolved
INSTALL MACHINERY GUARD ON PORT GENSET.
Engineering
Issued 27 June 2000
Resolved
INSTALL FLAME BOWL ON PORT GENSET FUEL STRAINER.
Lifesaving
Issued 27 June 2000
Resolved
DEMONSTRATE RETRIEVAL OF HELPLESS PERSON FROM THE WATER.
Lifesaving
Issued 18 May 1999
Resolved
PASSENGER CAPACITY REDUCED TO 147 PENDING REPLACEMENT/REPAIR OF THREE ADULTPFD'S. CONDUCT PREVENTATIVE MAINTENANCE ON CORRODED PFD FASTENERS AS NEEDED.
Navigation
Issued 18 May 1999
Resolved
PAINT NAV LIGHT SHIELDS MATTE BLACK.
Lifesaving
Issued 6 July 1998
Resolved
Replace deteriorated webbing on 25 adult-size PFD's and remove corrosion from metal fittings on an additional 14 adult-size PFD's. Total number of adults allowed on board, including required crew, is restricted to 116 adults pending completion.
Lifesaving
Issued 6 July 1998
Resolved
Install retro-reflective material on liferings. Install/replace tending line with buoyant line.
Lifesaving
Issued 6 July 1998
Resolved
Increase first-aid kit inventory to match USCG approved inventory.
Lifesaving
Issued 22 July 1997
Resolved
PASSENGER CAPACITY REDUCED TO 127 PENDING REPLACEMENT OF 23 ADULT-SIZE PFD'S.
Lifesaving
Issued 22 May 1996
Resolved
INSTALL ADEQUATE RETRO-REFLECTIVE MATERIAL ON BUOYANT APPARATUS.
Lifesaving
Issued 22 May 1996
Resolved
REPAIR/REPLACE SEVEN (7) ADULT PFD'S, PASSENGER CAPACITY REDUCED TO ONE HUNDRED AND FORTY THREE (143) PENDING REQUIREMENT COMPLETION.
Accommodation/Occupational Safety
Issued 30 August 1995
Resolved
Replace 3 broken windows starboard side main deck.
Lifesaving
Issued 23 May 1995
Resolved
Renew retro reflective tape on all pfds.
Navigation
Issued 23 May 1995
Resolved
Provide a method for lubrication of steering ram pins to rudders.
Construction/Loadline
Issued 23 May 1995
Resolved
Reposition watertight door indicator light to a location on the console which is readily visable to the operator.
Navigation
Issued 23 May 1995
Resolved
Prevent hydraulic hoses from chafing at steering ram.
Lifesaving
Issued 23 May 1995
Resolved
Replace spacers between port side lifefloats.
Accommodation/Occupational Safety
Issued 2 May 1995
Resolved
Renew broken glass on window, starboard side pilothouse door.
Construction/Loadline
Issued 2 May 1995
Resolved
Renew pipe servicing in bilge pump suction in starboard forepeak & reconnect pump suction.
Construction/Loadline
Issued 2 May 1995
Resolved
Renew top dog on starboard pilothouse door.
Construction/Loadline
Issued 25 May 1994
Resolved
Stencil "emergency escape keep clear" above and below all emergency escape hatches.
Unknown
Issued 27 May 1993
Resolved
Provide an approved relief valve for air receiver under pilot house console. Demonstrate operation in presence of marine inspector.
Engineering
Issued 27 May 1993
Resolved
Renew all fuel vent flame screens.
Electrical
Issued 27 May 1993
Resolved
Remove or reconnect abandoned electrical cable under pilot house console.
Lifesaving
Issued 27 May 1993
Resolved
Relabel forward lifejacket stowage box.
Lifesaving
Issued 17 June 1991
Resolved
REPAIR 1 BOUYANT APPARATUS LIGHT. LIMITED TO 120 PERSONS UNTIL COMPLETED.
Electrical
Issued 17 June 1991
Resolved
ADJUST AMMETERS P & S GENERATORS.
Fire Fighting
Issued 17 June 1991
Resolved
REPAIR FIRE PUMP PRIOR TO CARRYING PASSENGERS.
Electrical
Issued 17 June 1991
Resolved
SEAL SWITCHBOARD OPENINGS IN DISTRIBUTION SECTION.
Fire Fighting
Issued 17 June 1991
Resolved
STBD FIREMAIN OUTLET IS TO BE MODIFIED TO POINT HORIZONTAL OR DOWNWARD.
Fire Fighting
Issued 19 June 1990
Resolved
PROVIDE APPROX 20 FEET DISCHARGE HOSE AND CLAMPS ON HAND FIREPUMP BY 26JUL90.
Lifesaving
Issued 19 June 1990
Resolved
PROVIDE A SUITABLE RESCUE PLATFORM BY 19SEP90.
Electrical
Issued 19 June 1990
Resolved
SUBMIT ELECT DRAWINGS OF NEW GEN INSTALLATION SHOWING GEN NAME PLATE DATA, CABLE MFG, TYPE, SIZE AND CIRCUIT PROTECTION BY 19JUL90
Electrical
Issued 19 June 1990
Resolved
INSTALL BELT GUARD STBD GEN BY 19JUL90.
Documentation
Issued 17 June 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 17 June 1988
Resolved
PROVIDE PROOF OF FIXED CO2 SYSTEMS SERVICING.
Electrical
Issued 20 October 1987
Resolved
MAKE INDEPENDENT GENERATOR AVAILABLE FOR OPERATIONAL TEST PRIOR TO PLACING INTO SERVICE.
Electrical
Issued 22 June 1987
Resolved
BLANK THE TWO MISSING CIRCUIT BREAKERS IN THE PILOTHOUSE PANEL.
Navigation
Issued 22 June 1987
Resolved
PROVIDE A TIDE CHART FOR THE VESSEL'S AREA OF OPERATION.
Electrical
Issued 22 June 1987
Resolved
MAKE INDEPENDENT GENERATOR AVAILABLE FOR OPERATIONAL TEST PRIOR TO PLACING INTO SERVICE.
Documentation
Issued 22 June 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 28 October 1986
Resolved
REMOVE NON-OPERATIONAL AUXILIARY GENERATOR. MAKE NEW INSTALLATION AVAILABLE FOR INSPECTION PRIOR TO PLACING VSL IN SERVICE WITH NEW GENERATOR.
Construction/Loadline
Issued 25 June 1986
Resolved
MAKE OPERATIONAL, THE REACH ROD FOR THE BILGE SUCTION VALVE IN THE STAR- BOARD HULL FORWARD PEAK TANK.
Electrical
Issued 25 June 1986
Resolved
PROVE OPERATION OF THE AUXILIARY GENERATOR.
Engineering
Issued 25 June 1986
Resolved
INSTALL OPERATIONAL TACHOMETER FOR THE STARBOARD ENGINE.
Fire Fighting
Issued 25 June 1986
Resolved
PROVIDE SERVICING OF THE FIXED CO2 SYSTEM.
Accommodation/Occupational Safety
Issued 25 July 1985
Resolved
PROVIDE 42" SAFETY RAIL HEIGHT ON UPPER DECK PRIOR TO SPRING 1986 OPERATINGSEASON.
Electrical
Issued 24 June 1985
Resolved
MAKE BOTH INDEPENDENT GENERATORS AVAILABLE FOR TESTING AFTER REPAIRS ARE COMPLETED.
Construction/Loadline
Issued 24 June 1985
Resolved
MAKE ANCHOR WINCH AVAILABLE FOR TESTING.
Fire Fighting
Issued 24 June 1985
Resolved
MAKE ELECTRIC FIRE AND BILGE PUMP AVAILABLE FOR TESTING.
Casualty record · 7
14 March 2008Routine · role: Involved in a Marine Casualty · activity 3195887
13 November 2008Routine · role: Involved in a Marine Casualty · activity 3362907
25 March 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4274365
21 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4553958
2 April 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4562596
10 November 2017Routine · role: Involved in a Marine Casualty · activity 6305985
21 December 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7613512
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.