MAURY USCG vessel records Sign in
← All vessels

ENDEAVOR

ENDEAVOR is a 1972 passenger vessel (inspected). The Coast Guard has recorded 105 inspections since 1985, most recently in March 2025, along with 206 deficiencies and 3 casualty investigations between 2015 and 2022.

Records from 1985 to 2025. Most recent: inspection, 31 March 2025.

Built
1972
Last inspected
31 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7144
Flag
UNITED STATES
367452860
Maury page id
psix-47233

Inspections, by type

…with no type recorded19
Years with a record 37 calendar years (1985–2025)
The 105 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 19.0 ft × 7.2 ft
Registered tonnagegross 63 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO. · LONG BEACH, CA, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 17 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7144MMSI 367452860 · active · voluntarily equipped · granted 15 March 2019, expires 15 March 2029
WDF4521MMSI 367452860 · cancelled · compulsorily equipped · granted 18 May 2010, cancelled 22 February 2019
WCZ8758MMSI 366783840 · expired · compulsorily equipped · granted 14 June 2000, cancelled 14 August 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 105

31 March 2025 Deficiency Check · In-Service Inspection · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8093843
5 April 2024 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7890577
25 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7879885
17 January 2024 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7850541
11 January 2024 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7848532
18 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841005
16 October 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7806665
31 May 2023 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7704107
26 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7676089
18 November 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7558937
4 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7426685
25 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7437332
26 January 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385723
31 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7263320
25 February 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7125171
7 April 2020 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933372
29 January 2020 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6891878
18 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6837093
26 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6737095
5 June 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6679744
21 May 2018 Annual Inspection · Drydock Exam · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6419620
7 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6178048
8 June 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5901068
26 April 2016 Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5862801
29 September 2015 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5735928
29 September 2015 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5788246
11 June 2014 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4885474
7 May 2014 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4852483
16 July 2012 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4381178
27 June 2012 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4333527
22 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3189692
21 April 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3194127
8 April 2008 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3163716
17 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2905900
28 April 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2628748
11 April 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2606755
14 April 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2327059
13 May 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2047963
26 April 2004 Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2047591
13 April 2004 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2043395
15 July 2003 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1846867
12 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1875161
24 June 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1825477
28 May 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1799239
13 June 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1630524
4 June 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601675
9 April 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601700
4 February 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1483917
29 January 2002 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1482232
13 August 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 56251
24 May 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1366362
1 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1425072
27 June 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1053361
31 May 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429361
27 January 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373057
2 November 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1131953
2 November 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1132113
4 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369375
16 April 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1123945
23 December 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 811258
8 December 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1420037
17 April 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1469506
12 January 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404496
30 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378252
30 October 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439928
15 October 1997 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439927
27 January 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442506
12 March 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1363545
12 March 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1447538
28 December 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396425
3 November 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 714631
25 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 53246
25 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 212552
17 January 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1459160
9 November 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392113
31 October 1994 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 867691
19 January 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362913
22 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1135973
9 April 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150034
1 March 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840467
1 February 1993 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830405
5 January 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138530
8 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137728
2 March 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945711
16 October 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1245094
6 September 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1308537
28 August 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937393
1 February 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928324
23 January 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931212
9 January 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1231519
10 January 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203372
6 July 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 895959
17 February 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330885
11 January 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1322549
7 May 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023050
21 April 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007560
25 February 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312670
23 January 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1317375
15 July 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297365
9 June 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 994213
11 March 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299837
6 February 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1305435
9 January 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984701
24 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295340
9 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1286221

Deficiency record · 206

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 March 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's VHF radio was missing GPS input for DSC functionality. Install GPS input into VHF radio to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 1 April 2025
Resolution: Vessel replaced VHF radio and installed MMSI and GPS input. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2025 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.(1) Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Floating water light was cracked. Vessel installed new one on site during inspection. Deficiency rectified.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 31 March 2025
Resolution: Vessel replaced floating water light.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2024 Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have the passenger safety bill posted in passenger accommodation spaces. Post passenger safety bill to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 4 April 2024
Resolution: Passenger Safety Bill posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 March 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel's stern light was inoperable. Stern light was replaced during inspection.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel provided the (3) required fire buckets during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 25 March 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel provided and installed emergency radio placard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Accommodation)
Issued 25 March 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Vessel's emergency lighting was not working when initially tested by the marine inspector. Vessel identified a wiring issue, which was corrected. A satisfactory test of the passenger accommodation emergency lighting was witnessed by marine inspector.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 July 2021 Resolved
A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. When tested, the speaker located in the passenger bunk room was inoperable. Vessel moved a speaker from the forward weather deck and demonstrated operation to ensure ability to communicate to the bunkroom. Provide speaker for forward weather deck and demonstrate operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2021
Resolved 1 August 2021
Resolution: Vessel installed replacement speaker and demonstrated operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2021 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. The water light for the ring buoy was found during in-service inspection to be missing its battery. Vessel replaced battery during inspection.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 31 July 2021
Resolved 31 July 2021
Resolution: Corrected during inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 February 2021 Resolved
Provide operating instruction for the installed CO2 system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Instruction posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2021 Resolved
Replace grab lines and/or ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Ring buoy was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 February 2021 Resolved
Provide day shapes.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 February 2021
Resolved 11 March 2021
Resolution: Day shapes provided.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 25 February 2021 Resolved
Provide non-combustible waste bins.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2021
Resolved 11 March 2021
Resolution: Proper waste bins provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 February 2021 Resolved
FCC Safety certificate had the incorrect call sign. Have the certificate corrected.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2021
Resolved 26 March 2021
Resolution: FCC Safety Certificate has been reissued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessel's electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection. To be completed within 90 days. 46 CFR 177.05-1(a)(6).
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 January 2020
Resolved 14 April 2020
Resolution: Wiring diagram and insepction conducted. All sat.
Operations/Management › Drills/Instruction › Fire
Issued 7 June 2017 Resolved
Conduct emergency drill (fire/MIB) in presence of CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2017
Fire Fighting › Grease Extraction Hood › General
Issued 7 June 2017 Resolved
Clean galley ventelation ducting.
Due 7 July 2017
Resolved 16 June 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 June 2017 Resolved
Prove operation of FWD STBD emergency light in bunk room.
Due 7 June 2017
Resolved 16 June 2017
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 June 2017 Resolved
Ensure EPRIB test and drills are logged
Due 7 July 2017
Resolved 16 June 2017
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 June 2017 Resolved
Provide port fuel vent screen
Due 7 July 2017
Resolved 16 June 2017
Lifesaving › Lifefloat › Serviceable
Issued 7 June 2017 Resolved
Repair damaged life float (bottom STBD) Ser#3767. Damage is a hole/dent; COI passenger allowance is reduced by12 people until repaired; total people allowed is now 36.
Due 7 July 2017
Resolved 16 June 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 June 2016 Resolved
Renew one starboard side lifefloat waterlicht battery.
Due 8 July 2016
Resolved 16 June 2016
Resolution: Received battery purchase receipt from vessel's Master via email.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 26 April 2016 Resolved
Stbd cutlass bearings show uneven wear, replace.
Action required: 705 - Other - as specified
Resolved 2 May 2016
Resolution: Verified install of new stbd cutlass bearings.
Construction/Loadline › Hull › Hull Plating
Issued 29 September 2015 Resolved
Submit repair plan and make repairs to starboard bow.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 16 October 2015
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 June 2014 Resolved
Provide updated Coast Pilot
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: Updated coast pilot onboard
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 June 2014 Resolved
Install ammeter for gnerator
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: Ammeter for the genrator was installed and tested.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 June 2014 Resolved
Install a proper guard on bilge pump shaft in E/R
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: New gaurd installed and verified.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 11 June 2014 Resolved
Re-install 30/30 mesh flame screen on port fuel vent pipe terminal end.
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: A new flame screen was installed.
Documentation › Markings/Placards › Warning Signs
Issued 11 June 2014 Resolved
Re-label galley emergency exit to read "Emergency Exit Keep Clear"
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 11 July 2014
Resolution: The emergency exit was properly labeled.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 11 June 2014 Resolved
Prove proper operation of MF transmittor prior to operating beyond 20NM
Action required: 705 - Other - as specified
Resolved 11 July 2014
Resolution: Conducted a satisfactory test of the MF radio onboard.
Engineering › Bilge Water Management System › Valve
Issued 4 June 2012 Resolved
Provide plans for installation of check valves in each bilge line before manifold
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 27 June 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 June 2012 Resolved
Provide CG approved floating waterlight for lfie float
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 16 July 2012
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2012 Resolved
Post most recent stability letter onboard vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 16 July 2012
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 June 2012 Resolved
Obtain FCC Radio Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 16 July 2012
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 22 April 2008 Resolved
Vsl is restricted to 100 n-mile from shore until DSC Sideband is intalled.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 27 May 2009
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 April 2008 Resolved
Renew charts and outdated pubs
Action required: 705 - Other - as specified
Resolved 20 May 2008
Resolution: Charts and outdated pubs were renewed
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2007 Resolved
Replace floating waterlight on one lifefloat. Vessel restricted to nmt 36 persons until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 24 May 2007
Lifesaving › Lifefloat › Paddle
Issued 17 May 2007 Resolved
Attach all lifefloat paddles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 24 May 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 May 2007 Resolved
Renew retroreflective tape on two lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 24 May 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 May 2007 Resolved
Renew retroreflective tape on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 24 May 2007
Documentation › Certificates/Documents › FCC SSL
Issued 17 May 2007 Resolved
Provide proof of current FCC Safety Radio Telephony certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 24 May 2007
Lifesaving › Hand Flares › Quantity
Issued 28 April 2006 Resolved
Procure 3 smoke signals
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Lifesaving › Lifefloat › Platform
Issued 28 April 2006 Resolved
Repair steel platform in life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 28 April 2006 Resolved
Procure NAVTEX receiver w/ approved printer.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Resolution: O/OP did not procure NAVTEX but COI will be amended to reflect restriction in vessel operating over 100nms from shore.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2006 Resolved
Replace expired items in first aid kit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 28 April 2006 Resolved
Clean galley hood of accumulated grease.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 April 2006 Resolved
Label emergency fuel shut-offs.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2006 Resolved
Repair exhaust lagging on both MDE's.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 28 April 2006 Resolved
Provide a way to properly shut-off ventilation to engine room.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2006 Resolved
Clean or replace starboard navigation light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 2 June 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 April 2005 Resolved
Outdated pub. Vsl had a 1999 Edition of the Coast Guard Light List and no current updates.
Due 30 April 2005
Resolved 18 April 2005
Resolution: Vsl owner purchased a new 2005 Light List.
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2005 Resolved
Outdated navigational chart for the area transiting.
Due 30 April 2005
Resolved 18 April 2005
Resolution: Vsl owner purchased new charts.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 April 2005 Resolved
No Tidal Current Table pub on board.
Due 30 April 2005
Resolved 18 April 2005
Resolution: Vsl owner purchased a new 2005 Tidal Current Table book.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 April 2005 Resolved
Outdated pub. Vsl had a 1999 edition of the U. S. Coast Pilot and no updates.
Due 30 April 2005
Resolved 18 April 2005
Resolution: Vsl purchased a new 2005 Coast Pilot book.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 April 2005 Resolved
Missing pub. No Tide Table book on board.
Due 30 April 2005
Resolved 14 April 2005
Resolution: Vsl owner obtained a Tide Table book from the main office.
Communications › Radio Communications › EPIRB
Issued 13 May 2004 Resolved
Replace hydrostatic release on EPIRB.
Due 30 June 2004
Resolved 13 May 2004
Engineering › Bilge Water Management System › Not Operational
Issued 13 May 2004 Resolved
Demonstrate proper operation of bunkroom bilge alarm visual alarm.
Due 30 June 2004
Resolved 30 June 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 May 2004 Resolved
Renew lanyard on waterlight and 60' lifeline for ring buoy.
Due 30 June 2004
Resolved 30 June 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 May 2004 Resolved
Provide one additional childsize lifejacket for a total of 6 lifejackets.
Due 30 June 2004
Resolved 30 June 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 13 May 2004 Resolved
Install guards on fans in Laz adn forepeak.
Due 30 June 2004
Resolved 30 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2004 Resolved
Provide one additional package of Aspirin.
Due 30 June 2004
Resolved 30 June 2004
Operations/Management
Issued 13 April 2004 Resolved
13 April 2004- Mailed a DDE letter disapproving [name withheld] request for Dry Dock extension. Furthermore, we faxed a copy of a CG-835 to [name withheld] for the following deficiency: 1) A U.S. Coast Guard Marine Inspector shall conduct a hull inspection prior to carrying passengers for hire. LEGACY COMPONENT DESC: Dry Dock extension disapproval
Due 26 April 2004
Resolved 26 April 2004
Resolution: 26 April 2004-[name withheld] attended vsl. in Dry Dock. Cleared CG-835 issued 13 April 2004 limiting carriage of passengers.
Stability › Watertight Integrity
Issued 28 May 2003 Resolved
Remove rotten wood from forward bulkhead in lazarette and make ready for CG inspection IAW 46 CFR 179.320.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Operations/Management › Drug and Alcohol Testing
Issued 28 May 2003 Resolved
Provide valid enrollment in drug testing prograam IAW 46 CFR 16.230. LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Enrollment verified.
Operations/Management › Drug and Alcohol Testing
Issued 28 May 2003 Resolved
Provide annual drug and alcohol testing report for 2002 IAW 46 CFR 16.500. LEGACY COMPONENT DESC: Recordkeeping
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Owner provided report.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 May 2003 Resolved
Test EPIRB monthly and log results IAW 46 CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 28 November 2003
Resolved 12 August 2005
Accommodation/Occupational Safety › Ventilation
Issued 28 May 2003 Resolved
Provide vent screen for port vent in bunkroom IAW 46 CFR 177.600.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Operator installed screen over ventillation duct.
Accommodation/Occupational Safety › Ventilation
Issued 28 May 2003 Resolved
Clean galley vent hood IAW 46 CFR 184.220.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 29 May 2003
Electrical › Electric Supply System (service)
Issued 28 May 2003 Resolved
Install metallic clamps for overhead wiring in lazarette and engineroom IAW 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 29 May 2003
Electrical › Electrical Distribution System (service)
Issued 28 May 2003 Resolved
Remove extension cord for microwave IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 29 May 2003
Electrical › Electric Generation Source (service)
Issued 28 May 2003 Resolved
Clean generator windings IAW 46 CFR 183.200 & 176.830(b). LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 29 May 2003
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 May 2003 Resolved
Perform satisfactory man overboard drill IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2003
Fire Fighting › Means of Escape
Issued 28 May 2003 Resolved
Restencile or repaint "Emergency Exit, Keep Clear" above and below exit from bunk room IAW 46 CFR 185.606. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: New lettering was installed as required.
Fire Fighting › Means of Escape › Landings
Issued 28 May 2003 Resolved
Remove mat obstructing emergency exit in galley IAW 46 CFR 177.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2003
Engineering › Bilge Water Management System
Issued 28 May 2003 Resolved
Repair visual alarms for bilge system in forepeak and bunk room IAW 46 CFR 182.530(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2003
Engineering › Bilge Water Management System
Issued 28 May 2003 Resolved
Install metallic valve on metallic sie of piping for lazarette bilge system IAW 46 CFR 182.720(d)(1)(ii)(c). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Valve installed.
Engineering › Bilge Water Management System
Issued 28 May 2003 Resolved
Repair inoperable bilge alarm in lazarette/pump room IAW 46 CFR 183.340.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2003
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 May 2003 Resolved
Double clamp salt water suction for generator cooling and MSD intake.
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 29 May 2003
Electrical › Electric Supply System (service)
Issued 28 May 2003 Resolved
Place cover on junction box for washdown pump IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Verified installation of proper cover
Lifesaving › Rescue Boat Equipment
Issued 28 May 2003 Resolved
Provide adequate rescue ladder of a metallic/aluminum type to prevent ladder from swinging under vessel.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 24 June 2003
Resolution: Inspected ladder, all SAT
Documentation › Certificates/Documents
Issued 4 June 2002 Resolved
Provide "Small Passenger Vessel Sticker" IAW 46 CFR 176.107
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 19 June 2002
Documentation › Logs/Records
Issued 4 June 2002 Resolved
Provide drug testing documentation for new crew member prior to using individual for trips for hire.
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 19 June 2002
Documentation › Logs/Records
Issued 4 June 2002 Resolved
Log epirb testing IAW 46 CFR 185.728 (c). LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 19 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 June 2002 Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 19 June 2002
Lifesaving › Launching Appliances
Issued 4 June 2002 Resolved
Replace expired hydrostatic release for epirb.
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 19 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 June 2002 Resolved
Remove excess oil from tops of both port and starboard engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2002
Resolved 5 June 2002
Accommodation/Occupational Safety
Issued 24 May 2001 Resolved
Provide proof of payment of user fees for current year.
Condition: Unknown
Due 7 June 2001
Resolved 30 June 2001
Accommodation/Occupational Safety
Issued 24 May 2001 Resolved
Provide additional wording to make clear location of emergency exit from STBD side of berthing space.
Condition: Unknown
Due 7 June 2001
Resolved 30 June 2001
Navigation
Issued 24 May 2001 Resolved
Provide operable magnetic compass light.
Condition: Unknown
Due 24 June 2001
Resolved 30 June 2001
Construction/Loadline
Issued 1 February 2001 Resolved
Provide metallic valves and penetrations for PVC piping traversing watertight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 4 February 2002
Resolution: Vessel meets non-metallic piping installation requirements of 46 Code of Federal Regulations 182.700
Construction/Loadline
Issued 1 February 2001 Resolved
Provide damage control kit consisting of a mallet, various sized cone plugsand oakum in a labeled container/bag. Kit is to be stored in an accessible area above the bulkhead deck.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Electrical
Issued 31 May 2000 Resolved
Provide electrical plans detailing rewire of vessel.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Documentation
Issued 8 December 1998 Resolved
Make available for inspection complete Drug Polciy/Program and testing results.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Construction/Loadline
Issued 8 December 1998 Resolved
Make aft bulkhead of engine room water tight around both engine exhausts and the generator exhaust as well as repairing hole at lower port side of the bulkhead. This item shall be completed prior to carrage of passengers.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998 Resolved
Renew common painter for 12 + 15 person life floats.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 8 December 1998 Resolved
Bond starboard fuel tank fill to fuel tank prior to carrage of passengers.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Navigation
Issued 8 December 1998 Resolved
Repair leaking packing around starboard rudder stock prior to carrage of passengers.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Documentation
Issued 8 December 1998 Resolved
Provide current deviation table.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 12 January 1998 Resolved
Permanently secure port engine sea water strainer._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Unknown
Issued 30 December 1997 Resolved
Repair one 12 man lifefloat.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Replace the EPIRB automatic release devise.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Repair or replace the collision bulkhead.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Provide update charts and nautical publications as per 46 CFR 184.420
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Generator raw water suction, replace cracked hose and double clamp all hoses.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Stbd main engine exhaust repair cracks in the aft comaprtment, double clampboth main engine exhaust systems.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Generator fuel filter, supply a flame bowl.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Unknown
Issued 30 December 1997 Resolved
Have one 6 man and one 12 man lifefloat replaced.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Engineering
Issued 15 October 1997 Resolved
Reinstall belt guards for generator and stbd main engine.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Construction/Loadline
Issued 15 October 1997 Resolved
Remove oil from engine room bilge.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Construction/Loadline
Issued 15 October 1997 Resolved
Remove water from bilgesthuorgh out the vessel.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Engineering
Issued 15 October 1997 Resolved
Replace Generator exhaust piping prior to carring passengers.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Accommodation/Occupational Safety
Issued 15 October 1997 Resolved
Reconnect sewage overboard to the holding tank and close the discharge valve within three miles of shore.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Documentation
Issued 12 March 1996 Resolved
Vessel voyage restricted to 20 miles from a Harbor of Safe Refuge until owner provides an approved Class A EPIRB on board the vessel.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Documentation
Issued 12 March 1996 Resolved
Provide proof of payment of overdue inspection fee.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Documentation
Issued 12 March 1996 Resolved
Provide proof of change of name and ownership of vessel.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Documentation
Issued 12 March 1996 Resolved
Provide written designation for Senior Deckhand.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
REPAIR STBD FORWARD RAIL: REPLACE BROKEN WOOD AND REGLASS.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
TREAT DAMAGE TO PORT FORWARD ABOVE CHINE WHERE TOP TWO PLYWOOD LAMINATES ARE CRACKED.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
PROVIDE A PICTURE AS PROOF OF REPAIR TO BITTER END OF SKEG ABOVE THE WORM SHOE.
Condition: Unknown
Due 12 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
REPAIR DAMAGE SIGHTED BY LOSMS 28DEC95.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
PROVIDE REPAIR PROPOSAL AND REPAIR BILGE STRINGERS IN FISH HOLD AFTER MAKING AVAILABLE FOR COAST GUARD INSPECTION (REMOVING GLASS).
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 12 March 1996 Resolved
CONDUCT UNDERWAY CHECK RIDE PRIOR TO RECEIVING CREDIT DRYDOCK.
Condition: Unknown
Due 12 March 1996
Resolved 18 March 1996
Documentation
Issued 19 January 1994 Resolved
PROVIDE AND MAKE AVAILABLE FOR EXAMINATION BY CG MARINE INSPECTOR A CURRENTRADIO OPERATORS PERMIT FOR ALL VESSEL MASTERS EMPLOYED BY PARADISE SPORT FISHING WHO OPERATE VESSELS.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Navigation
Issued 19 January 1994 Resolved
PROVIDE FOR IMPROVED VENTILATION OF STEERING COMPARTMENT TO REDUCE CONDENSATION ON WOOD SURFACES IN COMPARTMENT.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Lifesaving
Issued 19 January 1994 Resolved
PROVIDE EVIDENCE OF ESTABLISHED TRAINING PROGRAM FOR ALL MASTERS & CREW MEMBERS IN DEALING WITH EMERGENCIES ON BOARD VESSEL.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Accommodation/Occupational Safety
Issued 19 January 1994 Resolved
PROVIDE PROPER REPAIRS FOR LADDER BASE SUPPORTS AT TOP OF LADDER LEADING FROM MAIN DECK TO PILOT HOUSE AS NOTED DURING INSPECTION.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Construction/Loadline
Issued 19 January 1994 Resolved
PROVIDE PROPER SUPPORT OF PVC PIPING SO THAT IT DOES NOT INTERFERE WITH OPERATION OF SEA VALVE IN WAY OF PORT PASSENGER BERTHING BILGE AREA.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Fire Fighting
Issued 19 January 1994 Resolved
PROVIDE & INSTALL PROPER BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS AS NOTED DURING THE INSPECTION.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Electrical
Issued 19 January 1994 Resolved
REMOVE ALL UNUSED DEADENDED WIRING, REPAIR WASTED WIRING, & PROVIDE PROPER SUPPORTS FOR CABLE RUNS EVERY 24" AS NOTED DURING INSPECTION. USE 46 CFR 183.05-.10 FOR GUIDANCE.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Construction/Loadline
Issued 19 January 1994 Resolved
REMOVE OILY WATER FROM ENGINE COMPARTMENT BILGES PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Navigation
Issued 19 January 1994 Resolved
PROVIDE CURRENT CHARTS & PUBLICATIONS FOR AREA OF OPERATION TO INCLUDE THE FOLLOWING; LOCAL NOTICE TO MARINERS, COAST PILOT, LIGHT LIST, TIDE TABLES, & CURRENT COPY OF SUBCHAPTER T REGULATIONS OF 46 CFR.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Engineering
Issued 9 April 1993 Resolved
REPLACE VESSELS PROPS.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 April 1993 Resolved
REPLACE WORM SHOE FROM DEPTH SOUNDER TRANSDUCER FORWARD.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 April 1993 Resolved
REPAIR GOUGES IN VARIOUS HULL LOCATIONS AND PROPERLY FIBER GLASS REPAIRS.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Engineering
Issued 9 April 1993 Resolved
REPLACE COOLING WATER INTAKE HOSE TO PORT ENGINE.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 April 1993 Resolved
REPAIR DAMAGED CAP RAIL AND CHAFFED AREA BELOW CAP RAIL ON FWD STBD SIDE OFVSL.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 April 1993 Resolved
REPLACE STEM IRON TO VSLS STEM.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Navigation
Issued 9 April 1993 Resolved
REPLACE FLANGE BEARING TO STBD RUDDER POST.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Engineering
Issued 9 April 1993 Resolved
REPLACE ALL CUTLASS BEARINGS.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 April 1993 Resolved
RECAULK WORM SHOE AND VESSEL'S KEEL.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Electrical
Issued 9 April 1993 Resolved
REPAIR OR REMOVE BARE WIRES IN WAY OF E/R BATTERY CHARGER.
Condition: Unknown
Due 9 May 1993
Resolved 22 April 1993
Engineering
Issued 9 April 1993 Resolved
REPLACE VSLS PROPS AND BEARINGS
Condition: Unknown
Due 9 April 1993
Resolved 9 April 1993
Lifesaving
Issued 5 January 1993 Resolved
REPAIR HOLES IN TOP PORT SIDE LIFE FLOAT.
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE WATER LIGHT FOR 6MAN LIFE FLOAT VSL IS RESTRICTED TO CARRYING 45 TOTAL PERSONS.
Condition: Unknown
Due 30 January 1993
Resolved 9 January 1993
Documentation
Issued 5 January 1993 Resolved
PROVIDE RADIO OPERATORS PERMIT FOPR VSL MASTER, RICHARD S. SEIBERT.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE ADEQUATE MEANS FO RETRIEVING A MAN OVER BOARD.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Engineering
Issued 5 January 1993 Resolved
REPAIR/ REPLACE PROT FUEL VENT FLAME SCREEN.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
REPAIR/ REPLACE EPIRB AND PROVIDE CURRENT BATTERY. VSL IS RESTRICTED TO WITHIN 20 MILES OF A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Electrical
Issued 5 January 1993 Resolved
REPAIR/ REPLACE ELECTRICAL PANEL DOOR IN ENGINE ROOM.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Electrical
Issued 2 March 1992 Resolved
PROPERLY INSULATE WIRING TO STERN LIGHT IN LAZARETTE.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Unknown
Issued 2 March 1992 Resolved
PROVIDE CURRENT MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Electrical
Issued 2 March 1992 Resolved
REPAIR OR REMOVE LIGHT FIXTURE ON PORT SIDE FORWARD IN ENGINE ROOM.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Construction/Loadline
Issued 2 March 1992 Resolved
BEEF UP STATIONS ON LIFE FLOAT DECK OF VESSEL.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Construction/Loadline
Issued 2 March 1992 Resolved
REPAIR/REPLACE FLOOR BOARDS IN BAIT TANK.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Accommodation/Occupational Safety
Issued 2 March 1992 Resolved
PROVIDE SECURING DEVICE FOR MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Electrical
Issued 2 March 1992 Resolved
PROVIDE BLANK FOR ELECTRICAL PANEL IN ENGINE ROOM.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Electrical
Issued 6 September 1991 Resolved
PROVIDE GLOBE AND GUARD FOR 12V LIGHT FIXTURE IN ENGINEROOM.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Electrical
Issued 6 September 1991 Resolved
REPAIR STARBOARD EMERGENCY LIGHTING IN BERTHING SPACE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Electrical
Issued 6 September 1991 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT (NEED TOTAL OF 3.)
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Engineering
Issued 6 September 1991 Resolved
MOUNT SPANNER WRENCH IN WAY OF EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Documentation
Issued 6 September 1991 Resolved
PROVIDE RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 6 September 1991 Resolved
PROVIDE DEBRIS SCREEN FOR BILGE SUCTION LINE IN LAZARETTE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 6 September 1991 Resolved
HAVE INSTALLED HALON SYSTEM SERVICED. PROVIDE COPY OF SERVICING REPORT TO USCG.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Navigation
Issued 6 September 1991 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 6 September 1991 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Lifesaving
Issued 6 September 1991 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Engineering
Issued 6 September 1991 Resolved
PROVIDE HOSE FOR DISCHARGE SIDE OF HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 6 September 1991 Resolved
REPLACE MISSING STEP ON PILOTHOUSE LADDER.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 28 August 1991 Resolved
SUBMIT PROPOSAL TO OCMI FOR PROVIDING ADEQUATE VENTILATION TO ENGINEROOM AND LAZARETTE TO REDUCE FURRING OF WOODEN STRUCTURAL MEMBERS.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Engineering
Issued 23 January 1990 Resolved
LABLE BILGE MANIFOLD LINES
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 23 January 1990 Resolved
SCRAPE AND TREAT FURRING IN PORT SIDE OF LAZERETTE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Engineering
Issued 23 January 1990 Resolved
LABLE FOREPEAK BILGE SHUTOFF VALVE AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Electrical
Issued 23 January 1990 Resolved
PROVIDE DEAD COVERS FOR LARGE CIRCUT BREAKER BOX IN ENGINE ROOM
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 9 January 1990 Resolved
REPAIR LOCK DOWN SCREWS ON THE FORWARD AND AFT HATCH COVERS.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Lifesaving
Issued 9 January 1990 Resolved
PROVIDE LIGHTS FOR TEN ADULT LIFE PRESERVERS, AND PROVIDE FOUR CHILD SIZE LIFE PRESERVERS. VESSEL IS RESTRICTED ON THE NUMBER OF PEOPLE IT CAN CARRY UNTIL THE LIFE JACKETS ARE PROVIDED.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Engineering
Issued 9 January 1990 Resolved
REATTACH THE STAINLESS BOWL ON THE STARBOARD REMOTE FUEL SHUT OFF.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Electrical
Issued 9 January 1990 Resolved
REPLACE THE RADIATOR MOUNTING BRACKET ON THE GENERATOR DURING UPCOMING DRYDOCK INSPECTION BUT NOT LATER THAN 09FEB90.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Engineering
Issued 10 January 1989 Resolved
REPAIR EXHAUST LEAK IN AFT STEERING COMPARTMENT ON PORT SIDE.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Accommodation/Occupational Safety
Issued 10 January 1989 Resolved
REPLACE CORRODED SEA VALVE ON PORT MSD OVERBOARD.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Navigation
Issued 10 January 1989 Resolved
PROVIDE SSB RADIO. (VESSEL IS LIMITED TO 20 MILES FROM A MAINLAND SAFE HARBOR UNTIL SSB PROVIDED.)
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Documentation
Issued 10 January 1989 Resolved
PROVIDE RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 10 January 1989
Resolved 10 January 1989
Construction/Loadline
Issued 6 July 1988 Resolved
REPAIR HOLE IN HATCH COVER OF BOW COMPARTMENT.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Engineering
Issued 11 January 1988 Resolved
REPAIR OR REPLACE BOTH TEMPERATURE GAUGES ON MAIN ENGINES.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Lifesaving
Issued 11 January 1988 Resolved
REPLACE WEAK LINK ON 6 MAN LIFE FLOAT.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Accommodation/Occupational Safety
Issued 11 January 1988 Resolved
SECURE HOT WATER HEATER TANK.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Construction/Loadline
Issued 11 January 1988 Resolved
CLEAN AND TREAT FURRING AT BUTT JOINTS IN ENGINEROOM UNDER FUEL TANKS.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Engineering
Issued 11 January 1988 Resolved
REPAIR OR REPLACE PORT MAIN ENGINE TACHOMETER.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Lifesaving
Issued 11 January 1988 Resolved
REPLACE PENDANTS ON 6 MAN LIFE FLOAT.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Lifesaving
Issued 11 January 1988 Resolved
REPLACE MAN LINE ON LIFE FLOAT.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Engineering
Issued 11 January 1988 Resolved
REPAIR OR REPLACE OIL PRESSURE GAUGES ON MAIN ENGINES AND GENERATOR.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Construction/Loadline
Issued 23 January 1987 Resolved
REPAIR FURRED WOOD IN ER OVERHEAD USING SOUND MARINE PRACTICES.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Navigation
Issued 23 January 1987 Resolved
REPLACE EPIRB BATTERY AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Fire Fighting
Issued 23 January 1987 Resolved
INSTALL BRASS NOZZLE TO FIRE HOSE.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 23 January 1987 Resolved
REPAIR PORT MAIN ENGINE TACHOMETER ON BRIDGE.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Construction/Loadline
Issued 23 January 1987 Resolved
REINSTALL SAFETY CHAIN ON LAZARETTE HATCH COVER.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Engineering
Issued 23 January 1987 Resolved
INSTALL DRIP TRAY TO CENTER FUEL FILTER.
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Navigation
Issued 23 January 1987 Resolved
REPAIR SINGLE SIDE BAND RADIO AND PROVE OPERATION OF 2182 DISTRSS FREQUENCY
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Lifesaving
Issued 23 January 1987 Resolved
PROVIDE TWO (2) ADULT PFD'S
Condition: Unknown
Due 23 January 1987
Resolved 23 January 1987
Construction/Loadline
Issued 9 June 1986 Resolved
REPAIR AS NECESSARY KEEL FRP TO FORWARD ONE-THIRD OF KEEL.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Navigation
Issued 9 June 1986 Resolved
REPACK RUDDER POSTS.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Engineering
Issued 9 June 1986 Resolved
CONDUCT UNDERWAY OPERATIONAL TEST (STEERING & ENGINES).
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Fire Fighting
Issued 9 January 1986 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Navigation
Issued 9 January 1986 Resolved
REPAIR STERN LIGHT AND PROVE OPERATION.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Lifesaving
Issued 9 January 1986 Resolved
PROVIDE 4 ADULT LIFE PRESERVERS WITH PROPER STENCIL, REFLECTIVE TAPE AND WATERLIGHTS.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Lifesaving
Issued 9 January 1986 Resolved
REPLACE OR REPAIR WATERLIGHT ON 1 LIFEFLOAT AND 1 RING BOUY AND PROVE OPERATION.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Engineering
Issued 9 January 1986 Resolved
PROVIDE PROPER LABEL FOR EMERGENCY FUEL SHUT OFFS (PORT AND STBD).
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986

Casualty record · 3

29 September 2015Routine · role: Involved in a Marine Casualty · activity 5788246
26 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6737095
25 April 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7437332
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.