MAURY USCG vessel records Sign in
← All vessels

CHEM VEGA

CHEM VEGA is a 1998 tank ship. The Coast Guard has recorded 40 inspections since 1998, most recently in March 2014, along with 13 deficiencies and 9 operational controls.

Records from 1998 to 2014. Most recent: inspection, 30 March 2014.

Built
1998
Last inspected
30 March 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9175743 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
472414
Flag
MARSHALL ISLANDS
—
Maury page id
psix-472414

Inspections, by type

…with no type recorded19
Years with a record 11 calendar years (1998–2014)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3253 - Convention (Subpart B), Net Ton
10300 - Dead Weight, Ton
13621 - Displacement, Ton
5994 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

30 March 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4825558
11 March 2014 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4814460
11 March 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4815954
19 July 2007 MARPOL Annex V Examination · STCW 95 Exam · ILO-147 Exam · ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3000614
25 June 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2986701
18 June 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2966288
15 June 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2962853
29 May 2007 MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2939187
13 October 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2800183
26 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2725403
18 July 2006 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2716777
1 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2593760
1 March 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2594208
26 February 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2592242
7 November 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2530328
11 October 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2511634
14 August 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2462103
27 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2449160
13 July 2005 ISPS II Exam · COC-CHEM Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2425033
1 November 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2232829
17 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2177166
30 May 2004 Certificate of Compliance · MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2086114
9 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2021473
9 February 2004 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2002965
13 September 2003 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1903957
2 May 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1785253
24 April 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1779817
14 February 2003 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745009
8 September 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1672392
7 June 2002 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1623354
7 May 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1640229
4 May 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1612730
29 April 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 289610
29 April 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362169
27 April 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277359
27 April 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 818110
8 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 37726
20 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 428849
2 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415444
2 May 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1123816

Deficiency record · 13

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 March 2014 Resolved
2555: Objective evidence discovered in expanded ISM exam revealed following non-conformities: Failure of Master and crew to properly implement company's environmental policy- failed to maintain ORB; failed to maintain a daily sounding book in accordance with SMS; report and perform proper repairs to OWS overboard discharge line. Internal audit is recommended. SOLAS IX/3 & 5 ISM Code: 2,7,9,10.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2014
Resolution: Received Class Report #14NYM0017.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 March 2014 Resolved
1740: The Vessel's oil content meter data log does not correspond with entries in the oil record book. The oil record book has a discharge entry dated 04MAR14 with no corresponding log data in the oil content meter. MARPOL Annex I/6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2014
Resolution: Received Class Report #14NY0087. Manufacture service tech to attend vessel by 11APR14.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 March 2014 Resolved
1730: Vessel's oil water separator overboard discharge piping was found with a temporary repair approximately 12 inches from the overboard valve.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2014
Resolution: Vessel completed permanent repair to overboard pipe.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 March 2014 Resolved
2199- The engineering department was not familiar with: operational maintenance of equipment (OWS); record keeping for machinery space operations (ORB). MARPOL Annex I/11.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2014
Resolution: Received Class Report #14NYM0017.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 19 July 2007 Resolved
The vessel's high level alarm on deck is not operating properly. The vessel may not load cargo in the United States until repairs are made.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 26 July 2007
Resolution: High level alarm fixed to the satisfaction of CG Marine Inspector.
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 May 2007 Resolved
Chemical washing station piping wasted. repair as origional to the satisfaction of the attending Coast Guard marine inspector within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 20 June 2007
Resolution: Vessels outstanding deficiency for wasted chemical washing station piping, has been repaired as evidenced by a total replacement and renewal of the chemical washing station to the original design. Proper operation was demonstrated, Successfully.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 July 2006 Resolved
Provide class report attesting to the proper operation of the oil content meter on the oily water separator.
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 26 July 2006
Resolution: Cleared per class (NK) report.
Fire Fighting › Means of Escape › Blocked
Issued 13 July 2005 Resolved
Ensure all Doors and Hatches are able to open from the inside Flag / Class to address the safety & security of all restricted access . Flag /Class to provide written report to local U.S. Coast Guard prior to 11Aug 2005
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 17 August 2005
Resolution: Received class report stating that all Doors/ Hatches have been checked and verified that they can be opened.
Deck/Cargo › Vapor Control Systems
Issued 2 May 2003 Resolved
All vapor collection manifolds do not have stud located at the top (12 o'clock position) of the flange. 46 CFR 39.20-1. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 5 May 2003
Resolution: Rcvd class report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 2 May 2003 Resolved
CT #5 Center overfill device inoperative. 33CFR155.480/46CFR153.408. Repair prior to loading cargoes requiring overfill device in CT#5C. LEGACY COMPONENT DESC: Liquid Level Gaging
Condition: Improper/Lack of Maintenance
Due 2 June 2003
Resolved 5 May 2003
Resolution: Rcvd class report attesting to repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 2 May 2003 Resolved
CT #5 Center deepwell pump leaking hydraulic fluid. SOLAS 74 Reg 26/I. Repair prior to loading cargo in CT #5 Center. LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 5 May 2003
Resolution: Rcvd class report attesting to repairs.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 February 2003 Resolved
Malfunctioning turbocharger (SOLAS 74, I/11): Determine cause of turbocharger problems, make permanent repairs, & conduct satisfactory tests to satisfaction of certificate issuing authority. LEGACY COMPONENT DESC: Turbocharger
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2003
Resolution: Per Master''s attestation vessel''s main engine turbocharger operated normally while underway offshore
Unknown
Issued 27 April 2000 Resolved
Prior to issue of vapor recovery endorsement, provide flange with stud for each vapor control connection.
Condition: Unknown
Due 4 May 2000
Resolved 18 May 2000

Ownership record