MAURY USCG vessel records Sign in
← All vessels

EURO SPIRIT

EURO SPIRIT is a 1998 freight ship. The Coast Guard has recorded 16 inspections since 1998, most recently in February 2020, along with 3 deficiencies.

Records from 1998 to 2020. Most recent: inspection, 24 February 2020.

Built
1998
Last inspected
24 February 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9153551 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
472484
Flag
LIBERIA
—
Maury page id
psix-472484

Inspections, by type

…with no type recorded3
Years with a record 13 calendar years (1998–2020)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13904 - Convention (Subpart B), Net Ton
15483 - Dead Weight, Ton
28222 - Displacement, Ton
46346 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

24 February 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6910274
14 August 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6781279
1 October 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6550846
5 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6348790
18 June 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6176712
21 December 2016 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6058574
9 February 2016 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5811383
4 August 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4099327
7 December 2009 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3645749
7 January 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3125791
16 March 2006 PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2603495
26 June 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2122445
19 March 2004 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2027631
12 May 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 289955
30 March 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 276293
26 December 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 423883

Deficiency record · 3

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2016 Resolved
1730 - Oily-water separating equipment - Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. The oily water separator was not operational and pressure gauges on stange one and two of oily water separator were not functional. - MARPOL 73/78 Annex I/14.2 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2016
Resolved 9 February 2016
Resolution: Deficiency rectified to the satisfaction of the coast guard. Class will oversee operation at the next US port.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 March 2006 Resolved
Emergency fire pump lacked shield for rotating machinery at vacuum pump (for removing air in suction line).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2006
Resolved 23 March 2006
Resolution: Received fax from class
Fire Fighting › Firemans Outfit › Air Hose
Issued 16 March 2006 Resolved
SCBA mask hose had hole and therefore was not kept in good order and available for immediate use at all times.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2006
Resolved 16 March 2006
Resolution: Witnessed removal of air hose from service and replacement in kind with new spare. Verified SMS maintenance logs: no omissions evident; SMS properly implemented. Determined that ship''s crew inadvertantly used mask that had been removed from service.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.