Inspection history · 39
15 June 2026
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8404997
13 April 2026
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8346861
12 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8294623
12 November 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8267108
25 October 2025
PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256385
16 June 2025
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8161293
8 May 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8130596
3 March 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8088210
6 November 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8029274
1 June 2024
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7924653
29 May 2024
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7922197
24 May 2024
Deficiency Check · PSC B · COC-CVE Quarterly
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7917022
27 March 2024
Administrative Inspection · ISPS Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7885043
25 March 2024
ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7884839
15 March 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7879460
14 March 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7879108
10 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7876736
9 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7876584
30 December 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7843757
4 November 2023
COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7819971
15 August 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7769135
12 May 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7692009
1 May 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7676792
13 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7608573
16 November 2022
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7591415
18 March 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7483924
23 February 2022
COC-CVE Annual · Ballast Water Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7398810
19 November 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7354038
3 August 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7276104
8 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937196
7 October 2019
COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829898
2 February 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618933
29 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6589524
13 November 2018
ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6577342
26 September 2018
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6549376
5 March 2018
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6362790
25 September 2017
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6328126
5 September 2017
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260345
2 September 2017
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6270218
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 May 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboat #2 rudder unable to rotate due to propeller impeding its movement and lifeboat #11 rudder unable to move.
74 SOLAS 20 III/20.2 17 ac cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Lifeboats were troubleshooted, fixed and operational prior to PSCOs departure. Deficiency was cleared by PSCO's prior to departing the cruiseship.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 May 2025
Resolved
The emergency spurce of electrical power shall be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the following services for th eperiods specified hereinafter, if the depend upon an electrical source for their operation. PSCO observed 04 inoperable embarkation lighting on starboard side; 03 located aft and 01 near the vicinity of lifeboat #09.
74 SOLAS 04/II-1/42.2 10ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2025
Resolution: Lightbulbs were exchanged and operational prior to PSCOs departure. Deficiency was cleared by PSCO's prior to departing the cruiseship.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 November 2024
Resolved
07103 - Where "A" class divisions are penetrated for the passage of electric cables, pipes, trucks, ducts, etc., or for griders, beams or other structual members, arrangements shall be made to ensure that the fire resistance is not impaired. PSCO observed a smoke machine installed in a theater compatment with air duct piping packed with towels leading through an A-60 boundary leaving a penetration in the bulkhead allowing smoke to pass. Code:17ac, Cite:74 SOLAS 97 II-2/18.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2024
Resolved 6 November 2024
Resolution: Vessel packed the through hole with a class approved A-60 fire compound which was accepted by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 November 2024
Resolved
07105 - Fire doors in main vertical zone bulkheads and stairway enclosures, designed to re-open upon contacting an object its path shall re-open sufficiently to allow a clear passage of at least 0.75 m but not more that 1 m. Fire door #6.17 re-opens completely, exceeding the maximum 1 m. Code: 16ac, Cite: 74 SOLAS 97 II-2/30.4.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 6 November 2024
Resolution: Vessel repaired the door so when the crash bar is activated, the door retract to the maximum 1 m.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 November 2024
Resolved
07105 - Fire doors in main vertical zone bulkheads and stairway enclosures shall be self closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. Fire doors #2.14, 9.05, and 8.19, were found closing under 10 seconds. Code: 16ac, Cite: 74 SOLAS 97 II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 6 November 2024
Resolution: Vessel conducted satisfactory repairs to the doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2024
Resolved
09209 - Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. A water pipe was found to be leaking over the control panel of compressor #4 creating an electrical hazard. Code: 16ac, Cite: 74 SOLAS 04 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 6 November 2024
Resolution: Class submitted satisfactory report attesting to the repair of the water pipe penetration preventing further water from affecting the #4 compressor control panel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2024
Resolved
Means of escape systems and appliances, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed excessive storage of gear in corridor on approach to carpenters office and throughout the bulkhead deck.
07123, 74 SOLAS (20) II-2/14.2.1.1.3
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2024
Resolved 25 May 2024
Resolution: DNV Report attached
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 May 2024
Resolved
The hull, superstructures, structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent. PSCO observed fire insulation missing above the water tight door 04 on deck 0 and on deck 2 above fire hydrant 02-21.
07101 SOLAS (97) II-2/23.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2024
Resolved 25 May 2024
Resolution: DNV Report attached
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 May 2024
Resolved
In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminescent strip indicators placed not more than 0.3 m above the decks at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily escape exits. PSCO observed the following emergency lighting locations as being INOP: entrance galley on deck 5, at carpenter workshop on deck 1, on I-95 corridor, zone 5 entire section of lights on both sides.
07120 74 SOLAS (97) II-2/28.1.10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2024
Resolved 25 May 2024
Resolution: DNV Report attached
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed that on deck 1 fire door 1-92 was not properly latching. On the same deck door 1-55 in the garbage room had a broken latch. On deck 4 fire door 4.18 in the stairway did not properly latch.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2024
Resolved 25 May 2024
Resolution: Repairs were made to the satisfaction of the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2024
Resolved
Fires hoses shall be of non-perishable material approved by the Administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. In interior location passengers ships carrying more than 36 passengers fire hoses shall be connected to the hydrants at all times. PSCO observed deck 0 laundry room locker hose not connected and deck 1 garbage room hose 01-24 hoses were not connected.
07110 74 SOLAS (97) II-2/4.7.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2024
Resolved 24 May 2024
Resolution: Repairs (hoses were connected) were made to the satisfaction of the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2024
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed on deck 1 hose station 01-06 had a leak on the hose connection valve.
07123 74 SOLAS (20) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2024
Resolved 25 May 2024
Resolution: Repairs were made to the satisfaction of the attending PSCO.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 10 March 2024
Resolved
All ships of 300 gross tonnage and upwards and passenger ships irrespective of size shall be fitted with, an echo depth sounding device, or other electronic means, to measure and display available depth of water. The staff captain for the VISION OF THE SEAS reported to the Marine Safety Unit Port Canaveral that the vessels Echo Depth Sounder is inoperable and therefore has no means of measuring water depth.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2024
Resolved 15 March 2024
Resolution: Replaced existing Echo Depth Sounder with new unit. TECH made all necessary connections, configured both transducer and system settings. New Echo Depth Sounder in good working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 December 2023
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD.
PILOT REPORTED TO THE DUTY PSCO THAT THE VESSEL EXPERIENCED AN ISSUE WITH ITS PORT SIDE PROPULSION SYSTEM, WHICH RESULTED IN A PORT SIDE LOSS OF PROPULSION; STARBOARD SIDE PROPULSION SYSTEM REMAINED FULLY OPERATIONAL.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 December 2023
Resolution: It was discovered that the port propulsion motor LV excitation breaker tripped due to faulty/burned out breaker charging motor & wornout plastic gear.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 November 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of open[ing]s and penerations in these divisions. FSDTT.04 for port separator room does not close when the exhaust ventilation is running. Fire door 0.27 with hold-back subject to remote release found propped open with a 35 lb dumbell. Engine workshop double leaf door 0.44 closes in less than 2 seconds.
7105 - 16ac
74 SOLAS 20 II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 9 November 2023
Resolution: Received DNV report no. N2567626, which reports that DNV carried out remote survey and confirmed to their satisfaction that FD TT.04 has been adjusted, FD 0.27 weight has been removed, and FD 0.44 adjusted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 November 2023
Resolved
Where pipes, scuppers, electrical cables etc are carried through watertight subdivision bulkheads, arrangements shall be made to ensure the watertight intergrity of the bulkheads. A multi-cable transit in transvere watertight bulkhead at frame 160 near EL S/Stations FZ N3 was found not properly sealed.
03108 - 16ac
74 SOLAS 04 II-1/15.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 9 November 2023
Resolution: Received DNV report no. N2567626, which reports that DNV carried out remote survey and confirmed to their satisfaction that the damaged penetration has been replaced by a new one.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2023
Resolved
Means of escape,including stairwells and exits, shall be marked by lighting or photoluminiscent strip indicators placed not more than 0.3m above the deck at all points of the escape route including angles and intersections. A strip of low location lighting in the forward passenger stairwell at deck 8 on both sides was found inoperable.
07120 - 16ac
74 SOLAS 97 II-2/28.1.10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 9 November 2023
Resolution: Received DNV report no. N2567626, which reports that DNV carried out remote survey and confirmed to their satisfaction that the inoperable low location lighting has been repaired, tested, and found operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2023
Resolved
Marking must enable passengers to identify all routes of escape and identify the escape exit. PSCO observed the men's sauna changing room sign is missing an exit sign.
07120 - 10c
74 SOLAS 97 II-2/28.1.10
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 4 November 2023
Resolved 4 November 2023
Resolution: Crew added an exitsign to bulkhead. Deficiency was resolved to the satisfacion of the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 November 2023
Resolved
Any required automatic sprinkler shall be capbale of immediate operational all times. PSCO found that the sprinkler head on stairway 43, compartment ten in way of cabins 1681-1713 and 1414-1429 was corroded and did not activate when actuated. Additionally, on deck six near ships had a leaking sprinkler head.
07109 - 10c
74 SOLAS 01 II-2/12.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2023
Resolved 5 November 2023
Resolution: Sprinkler heads were replaced. Deficiency was resolved to the satisfacion of the attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2023
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed in fan room 507 electrical equipment was secured but not tagged out.
09209 - 10c
74 SOLAS 04 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 November 2023
Resolved 4 November 2023
Resolution: Crew properly tagged out piece of equipment. Deficiency was resolved to the satisfacion of the attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2023
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements: double-leaf doors equipped with a latch necessary to their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. Sequence devices on double-leaf doors (8.15 and 9.26) are not operating as designed and did not properly indicate their open position from the bridge. 74SOLAS (97 CONS) ii-2/30.4.5 10ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 May 2023
Resolution: Doors were adjusted properly and new sequencing bars were installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 May 2023
Resolved
…the means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than .3m above the deck at all points of the escape route including angles and intersections. The lighting in deck 4 zone 1 was found to be non-operational. 74SOLAS (97 CONS) II-2/28.1.10 10ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 May 2023
Resolution: Low location lighting was made operational by ships electrician.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 November 2022
Resolved
Remote controlled sliding or power-operated doors shall be equipped...and designed to open sufficently to allow a clear passage of least 0.75m but no more than 1m. Fire doors existing the Aquarius Dinging Room would not re-open upon contact.
74 SOLAS (97) II-2/30.4.2 (16 ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 13 December 2022
Resolution: Class attestation provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2022
Resolved
Any required automatic sprinkler, fire detection, and fire alarm system shall be capable of immediate operation. PSCOs observed a smoke detector (C02.03) covered with a plastic bag rendering it in-operable.
74 SOLAS (97) II-2/12 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 16 November 2022
Resolution: Vessel personnel removed bag and the smoke detector alarmed correctly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 October 2019
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures space satisfy the following requirements...The doors shall be self closing. Fire doors 1.69, 5.11, 6.08, 8.15, 8.25, and 8.27 would not close due to either inoperable sequencing bars or worn/missing hinges. 74SOLAS (97 CONS.) II-2/Reg. 30.4; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 24 October 2019
Resolution: Class report submitted. Deficiency cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone. On the eleventh deck one of the means of escape was through a sliding glass door which was locked and could only be open by breaking the glass. In addition, door 2.19 in the AC Room was locked and needed a key to exit. 74SOLAS (97 Cons.) II-2/Reg. 28.1.2 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 24 October 2019
Resolution: Class report submitted. Deficiency cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019
Resolved
The addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photo-luminescent strip indicators. Exit sign in fan room S10B was not illuminated. In addition, emergency exit sign across from crew cabin 1977 was missing. 74SOLAS (97 CONS.) II-2/ Reg. 28.1.10 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 24 October 2019
Resolution: Class report submitted. Deficiency cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019
Resolved
Above the bulkhead deck there shall be at least two means of escape from each vertical zone. The photo lab on deck 0 converted a locker into an office that did not have proper means of escape. 74SOLAS (97 CONS.) II-2/Reg. 28.1.2 (16 ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 24 October 2019
Resolution: Class report submitted. Deficiency cleared
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 November 2018
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed liferaft team unable to properly deploy liferaft for safe entry.
74 SOLAS (2014) III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 22 November 2018
Resolution: Vessel submitted satisfactory evidence of completed life raft deployment
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2018
Resolved
The construction of all doors and door frames in "A" class divisions shall provide resistance to fire as well as to the passage of smoke and flame, equivalent to that of the bulkheads in which the doors are situated. PSCO observed multiple fire doors around vessel unable to properly close, compromising "A" class boundary. Fire screen doors include: 1.92, 5.29, 1.73, 2.42, 3.18, 4.10, 6.44, 7.08, 9.03, and 9.10.
74 SOLAS (1997) II-2/30.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 29 November 2018
Resolution: DNV-GL class report submitted attesting to the rectification.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 November 2018
Resolved
The means of escape including stairways and exits shall be marked by lighting or photo luminescent strip indicators at all points of the escape route. PSCO observed low location lighting on decks 1, 3, 4, 5, and 8 to be out in sections.
74 SOLAS (1997) II-2/28.1.10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 29 November 2018
Resolution: DNV-GL class report submitted attesting to the rectification.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 November 2018
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed. PSCO observed toe locks on glass theater doors outside masquerade.
74 SOLAS (1997) II-2/28.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 29 November 2018
Resolution: DNV-GL class report submitted attesting to the rectification.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 November 2018
Resolved
Where the contents and use of a space are such that there is a doubt as to it's classification, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Flammable storage cabinets located at centerline deck 0 in the fork lift room designated as a category 13 space instead of being stored in a category 14 space.
74 SOLAS (1997)/ II-2/26.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 29 November 2018
Resolution: DNV-GL class report submitted attesting to the rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 November 2018
Resolved
All life saving appliances shall be fitted with retro-reflective material where it will assist in detection. Lifeboats 7, 8, 9, and 10 have retro-reflective tape on the underside of the craft painted over, rendering material ineffective.
74 SOLAS (1997)/ 30.2.7
Action required: 10 - Deficiency Rectified
Due 27 November 2018
Resolved 13 November 2018
Resolution: Ship personnel replaced the retro-reflective tape on all lifeboats.
Communications › Alarms/Indicators › Fire Alarm
Issued 5 March 2018
Resolved
Required fire detection system shall be capable of immediate operation. Vessel found with an active fault in loop 10, zone C. Vessel crew unable to determine cause at time of examination. Cite: 74 SOLAS (97 Cons) II-2/12.1.1
Action required: 705 - Other - as specified
Due 19 March 2018
Resolved 19 March 2018
Resolution: Received Class report attesting to faulty sensor found in loop. Replaced and found in SAT working order.
Documentation › Certificates/Documents › International Load Line Exemption Certificate
Issued 5 March 2018
Resolved
The periodic inspections of this article shall be endorsed on the International Load Line Exemption Certificate. Vessel was missing 4th periodic endorsement on ILLC Exemption Certificate. Cite: ILLC (96) Article 14(2)
Action required: 705 - Other - as specified
Resolved 5 March 2018
Resolution: Class surveyor onboard provided survey report and attested to missing signature as an oversight. Cleared on the spot.
Communications › Radio Communications › EPIRB
Issued 5 March 2018
Resolved
A satellite EPIRB shall be capable of floating free. Vessel is equipped with 02 EPIRBs, one on each bridge wing which are located adjacent to an overhead awning which may impede float free arrangement. Cite: 74 SOLAS (2014) IV/7.6.6.4
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 19 March 2018
Resolution: Received Class report and pictures from Master attesting to relocation of EPIRB to Deck 12.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 5 March 2018
Resolved
Fire doors in main vertical zones shall upon contacting an object in its path shall re-open to allow a clear passage no more than 1 meter. PSCO found fire door 9-19 would open completely upon activation of door's panic bar. Cite: 74 SOLAS (97 Cons) II-2/30.4.2
Action required: 705 - Other - as specified
Resolved 5 March 2018
Resolution: Crew adjusted door and witnessed SAT operational test. Cleared on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 September 2017
Resolved
A DOOR DESIGNED TO RE-OPEN UPON CONTACTING AN OBJECT IN ITS PATH SHALL REOPEN NOT MORE THAN 1M FROM THE POINT OF CONTACT. SLIDING FIRE DOOR 4.10 DID NOT REOPEN UPON CONTACT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 7 September 2017
Resolution: Corrected on the spot