Records from 1998 to 2010. Most recent: inspection, 5 October 2010.
Inspection history · 23
5 October 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3861189
12 May 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3472962
3 July 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3253632
3 July 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3255665
9 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202437
9 May 2008
MARPOL Annex V Examination · PI Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202586
1 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3196886
28 April 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3194116
23 April 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3190882
14 April 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3184181
23 October 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3085327
8 October 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3075424
14 June 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2961689
13 June 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2960817
13 June 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2961869
12 June 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2959763
23 September 2006
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2784096
1 March 2005
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2301148
25 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1992339
20 January 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1988229
18 June 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279017
28 September 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 420725
5 March 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 414113
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2008
Resolved
The vessel was involved in an allision with a barge that had broken loose, resulting in a 2ft by 2ft inset with a 1ft by 1 inch gash to the starboard bow in way of forepeak tank
Action required: 705 - Other - as specified
Due 9 May 2008
Resolved 16 May 2008
Resolution: Received class report from NKK satisfying requirement.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 October 2007
Resolved
Vessel fire control plan does not clear indicate the difference between class "A" and class "B" doors. It is unclear which doors needed to be self closing. The FIRE CONTROL PLAN is to be reviewed and amended as appropriate b a class representative during next dry dock prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 April 2008
Resolution: Received Approved and corrected fire control plan satisfying requirement.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 7 October 2007
Resolved
Received notification that the 10cm radar onboard the vessel is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2007
Resolution: Received notification that the 10cm radar onboard the vessel is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 13 June 2007
Resolved
Vessel had mixed garbage at final collection point.
Action required: 705 - Other - as specified
Resolved 15 June 2007
Resolution: Garage was sorted.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 June 2007
No resolution recorded
Received notification that the 10cm radar onboard the vessel is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Received satisfactory tech report that repairs have been made.
Lifesaving › Lifeboat Equipment
Issued 20 January 2004
Resolved
Food rations in port lifeboat not airtight. Replace food rations prior to departure and fax receipt to Marine Safety Office Miami. LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2004