Records from 1998 to 2001. Most recent: inspection, 14 August 2001.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 14 August 2001
Resolved
SPANNER WRENCHES FOR ENGINEROOM FIRE STATIONS; THREE MISSING. SOLAS 74 AMENDED II-2/4.7.2.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Fire Fighting
Issued 14 August 2001
Resolved
FIRE HOSE IN ENGINE ROOM HAS A HOLE. SOLAS 74 II-2/4.7.2.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Engineering
Issued 23 April 1998
No resolution recorded
Vessels lube oil fill pipe does not have required oil containment, as per MARPOL 73/78 Annex I/Reg.9(1) and 33CFR155.320.
Condition: Unknown
Due 23 May 1998 — due date passed with no resolution recorded
Navigation
Issued 28 March 1998
Resolved
Required pre arrival tests were not conducted nor logged in non-adherence with 33CFR164.25
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 28 March 1998
Resolved
While conducting the deck walk it was found that the flame screens were missing from vents number 17, 18, and generator oil service. SOLAS 74 amended I/11
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 28 March 1998
Resolved
Found guard rails missing/deteriorated on the ladders leading to the forecastle starboard and at the mast landing in non-adherence with ICLL 66 reg. 25
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Documentation
Issued 28 March 1998
Resolved
While looking at the vessels dangerous cargo manifest, it was found that the DCM was missing required information. Missing were the vessels flag, call sign, hazard class for materials, the preparers statement and signature, and number of packages in non-adherence with 49CFR176.30.
Condition: Unknown
Due 28 March 1998
Resolved 21 April 1998
Accommodation/Occupational Safety
Issued 28 March 1998
Resolved
Starboard door forward of superstructure leading to engine room will not close properly in non-adherence with ICLL 66 reg. 12
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Documentation
Issued 28 March 1998
Resolved
Freight container carrying class 8 hazardous material was missing placard in non-adherence with 49CFR172.504.
Condition: Unknown
Due 30 March 1998
Resolved 21 April 1998
Fire Fighting
Issued 28 March 1998
Resolved
While conducting the test of the fire pumps it was found that the riser pipe from the emergency fire pump was holed. The crew corrected the leak the following day by welding a new section in the pipe._x001C_ SOLAS 74 amended II-2/4
Condition: Unknown
Due 29 March 1998
Resolved 23 April 1998
Accommodation/Occupational Safety
Issued 28 March 1998
Resolved
While conducting a deck walk it was found that the ladder steps at the engine room escape, aft entrance to starbord passageway, emergency generator room hatch, and the aft entrance to port passageway are deteriorated in non-adherence with ICLL 66 reg. 25
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Construction/Loadline
Issued 28 March 1998
Resolved
Vent closures for the paint locker could not be secured in the event of a fire. Also found stack vent to be frozen and unable to operate. (this deficiency was later corrected.) ICLL 66 reg. 19
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Electrical
Issued 28 March 1998
Resolved
Lighting fixtures on the port passageway and lifeboat embarkation station were not operating in non-adherence with SOLAS 74 amended I/11
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 28 March 1998
Resolved
Vessel disposes of plastic at sea. Vessel did not segregate the garbage._x001C_ _x001C_ _x001C_ 33CFR151.67
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 28 March 1998
Resolved
Fire station was found to be missing fire hose and nozzles at the forward most station port side aft of the bos'n locker. SOLAS 74 amended II-2/21_x001C_
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 28 March 1998
Resolved
During deck walk it was found that the lube oil fill pipes were missing containment around each fill pipe in non-adherence with MARPOL 73/78 annex I/reg 9(1).
Condition: Unknown
Due 23 May 1998
Resolved 4 May 1998
Documentation
Issued 28 March 1998
Resolved
While conducting the examination of the galley it was found that the vesseldid not have a waste management plan onboard or posted in non-adherence with 33CFR151.57 and MARPOL 73/78 annex 1/reg. 9
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998