MISS BUFFALO II

MISS BUFFALO II is a 1972 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1980, most recently in May 2026, along with 117 deficiencies, 1 operational control and 3 casualty investigations between 2005 and 2016.

Records from 1980 to 2026. Most recent: inspection, 27 May 2026.

Built
1972
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WK3162
Flag
UNITED STATES
367095150
Maury page id
psix-47264

Inspections, by type

…with no type recorded16
Years with a record 41 calendar years (1980–2026)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)81.9 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 88 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF BOAT BUILDING CORP · BILOXI MS, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBUFFALO, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WK3162MMSI 367095150 · active · compulsorily equipped · granted 18 June 2026, expires 19 April 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS BUFFALO Passenger (Inspected) · MISLE 46291 · 5 June 2002 · activity 1627494CG49413 Public Vessel, Unclassified · MISLE 588124 · 5 June 2002 · activity 1627494

Inspection history · 76

27 May 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8381718
29 May 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8145296
18 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8004848
18 June 2024 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7947193
23 May 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7918082
8 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7683666
18 April 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7433073
13 July 2021 Examination of Repairs · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7253609
6 May 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7183525
10 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7051988
29 May 2019 Annual Inspection · Drydock Exam · DAPI Audit · Administrative Inspection · MTSA Verification · Internal Structural Exam · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6697245
8 May 2018 Administrative Inspection · Annual Inspection · In-Service Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6366218
3 April 2017 COI Inspection · MTSA Verification · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6163302
1 October 2016 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6013183
1 September 2016 Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5989567
12 April 2016 MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5852638
30 March 2016 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5843770
16 May 2014 DAPI Audit · In-Service Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4841340
10 May 2012 DAPI Audit · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4302225
9 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4205116
11 July 2011 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4077940
11 May 2009 Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3472559
20 May 2008 Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3213621
11 May 2007 MTSA Verification · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2928022
10 May 2007 Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2926842
25 May 2006 Re-Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2658952
20 August 2005 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2478517
4 August 2005 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2451135
24 July 2005 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2522712
24 July 2005 Hull Examination · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2523356
23 June 2005 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2400246
20 May 2005 MTSA Verification · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2363541
26 May 2004 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2078741
16 April 2004 Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2045251
2 October 2003 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1919450
28 May 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1820619
29 July 2002 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1653593
17 June 2002 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1631832
5 June 2002 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1627494
26 April 2002 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1609829
3 May 2001 Deficiency Check · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1448278
17 August 2000 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 660548
8 June 2000 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 213112
8 June 2000 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1052508
26 May 2000 Deficiency Check · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1461291
2 May 2000 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 100669
26 July 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1106463
4 May 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1129898
4 May 1999 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1450297
23 April 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1125141
11 March 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 811413
31 December 1998 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1464813
16 September 1998 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 800544
22 May 1998 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1419953
2 June 1997 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 787087
6 May 1997 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1368217
3 May 1996 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1390251
12 May 1995 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1422510
3 May 1995 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1390053
10 May 1994 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1428337
21 October 1993 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1426837
16 June 1993 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 660547
6 May 1993 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1370600
4 June 1992 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 948437
11 May 1992 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1462298
13 August 1991 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 660549
23 May 1991 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1234501
4 May 1990 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 929165
9 May 1989 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1208463
26 October 1988 Deficiency Check · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1200385
10 May 1988 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1041802
8 May 1987 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1326785
16 May 1986 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 988083
21 May 1985 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1288134
5 November 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277786
17 December 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277034

Deficiency record · 117

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 May 2026 Resolved
Each vessel that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery was expired. Vessel is restricted to operations within one mile from shore. Repair, replace, or renew lights to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2026
Resolved 14 July 2026
Resolution: Recieved EPIRB with new battery installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2026 Resolved
The master of the vessel shall ensure that each EPIRB be tested monthly and logged or otherwise documented. EPIRB must be tested and logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2026
Resolved 14 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2026 Resolved
Each life float must be fitted with a light. Two life float lights were inoperable. Vessel is restricted to operations within one mile of shore. Repair, replace, or renew lights to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2026
Resolved 24 June 2026
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 May 2026 Resolved
The owner or operator must make the vessel available for all specific inspection and drills, including man overboard (MOB) and fire drills. Vessel crew must conduct Coast Guard supervised MOB and fire drill to complete annual inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2026
Resolved 14 July 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2026 Resolved
Stations in the maritime service must be licensed by the FFC. FCC Station License expired 19Apr2026. Renew license to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2026
Resolved 24 June 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the a Serious Marine Incident. Alcohol testing devices were expired. Use alternative method of ensuring 2 hour timeline is met and replace testing device to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2026
Resolved 24 June 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2026 Resolved
The Vessel Security Officer must keep records of each drill or exercise including the date held, description of drill or exercise, list of participants, and any best practices or lessons learned which may improve the Vessel Security Plan. Vessel did not record most recent security drill or exercise.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2026
Resolved 14 July 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2026 Resolved
A fire hose with a nozzle must be attached to the each fire hydrant at all times. The fire hose connected to the port hydrant leaked when tested. Vessel replaced hose.
Action required: 10 - Deficiency Rectified
Due 27 May 2026
Resolved 24 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 May 2025 Resolved
A vessel on a Great Lakes route must carry six hand red flare distress signals and 6 orange smoke distress signals. Red hand flare distress signals may be substituted for orange smoke distress signals. Outfit vessel with proper number of flares to the satisfaction of attending CG Marine Inspector. 46 CFR 117.68
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 13 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2025 Resolved
Each life float must be fitted with a light. Light was not put on station at the beginning of the season. Light was put on station during annual. Corrected on the spot. 46 CFR 117.175 (d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 May 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect persons from electrical hazards. Main panel disconnect switch selector knob is missing. Replace knob to the satisfaction of attending CG Marine Inspector. 46 CFR 120.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 13 June 2025
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 May 2024 Resolved
Each vessel that operates beyond three nautical miles from the coastline of the Great Lakes must have on board an EPIRB. Vessels EPIRB was not onboard. Vessel is not to operate beyond 3NM until a new EPIRB is registered to the vessel and onboard. 46 CFR 117.64
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 May 2026
Resolution: Vessel has registered epirb, but battery is expired. Cleared this def and issued a new one for battery replacement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2024 Resolved
Rail and courses IWO starboard quarter access gate and mooring bitts have excessive clearance overboard. Employ temporary safety policies to ensure passenger safety. Submit repair proposal to attending CG Marine Inspector. 46 CFR 116.900
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 2 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022 Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 122.604 of this chapter. 02 life jackets were mislabeled but replaced with 02 new life jackets during inspection.
Action required: 10 - Deficiency Rectified
Due 5 May 2022
Resolved 5 May 2022
Resolution: o/o repalced worn life jackets with 02 new properly labeled life jackets
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 April 2022 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Testing records of crew were not available. Submit test results of crew
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 5 May 2022
Resolved 13 May 2022
Resolution: POC provided docs to MI showing crew compliance
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 April 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The ends of the fuel tanks did not have the correct mesh screens. Replace with required 30x30 screen.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 10 May 2022
Resolution: MI witnessed replacement of screens with required type
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2022 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in a machinery space bilge. While testing engine room bilge alarm, the light at operation station was inoperable. Replace light to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 13 May 2022
Resolution: POC provided objective evidence to MI
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 April 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 in sub chapter A of this chapter shall comply with the requirements of § 4.06 in sub chapter A of this chapter. Drug and alcohol testing swabs were not on board vessel. Either acquire enough testing kits for the whole crew and stow on board, or submit a plan to OCMI to have testing done off site within required regulatory time frame.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 5 May 2022
Resolved 9 May 2022
Resolution: MI witnessed testing kits onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2021 Resolved
Starboard loss of propulsion
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 May 2021 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Although length of hoses currently allows pressure of water to reach all spaces protected, pressure gage reading at pump is reading 15 PSI. Rectify pressure to meet requirement of not less than 60 PSI at pump outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 28 May 2021
Resolution: Replaced pump.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 May 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. First aid kit contents expired. Replace required contents of first aid kit with unexpired items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 28 May 2021
Resolution: Replaced expired items/
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 May 2019 Resolved
Each vessel certificated for Great Lakes service must have emergency positioning indicating radiobeacon (EPRIB) installed in a readily accessible location, at or near the principal steering station. Vessel did not have EPIRB on board at time of inspection. Please provide operable EPIRB. Vessel restricted to 3 nautical miles.
Action required: 705 - Other - as specified
Resolved 12 June 2019
Resolution: Provided satisfactory EPIRB
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 May 2019 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date charts, coast pilots and light lists. Vessel did not have corrected charts or latest publications of coast pilot and light list. Please provide corrected or updated nautical publications
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 12 June 2019
Resolution: Provided satisfactory charts
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 May 2019 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Deadend wire was found on port side under instrument panel in pilothouse.
Action required: 10 - Deficiency Rectified
Due 29 May 2019
Resolved 29 May 2019
Resolution: Corrected on spot by heat-shrinking cap onto end of wire.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 April 2017 Resolved
Need additional 4 lifejackets to complete the total 198 required count
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Vessel obtained an additional 4 lifejackets in satisfactory condition to complete the total 198 required count
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 April 2017 Resolved
Re-stencil 1 Box to account for total 198 adult life jacket count
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Adult Life Jacket storage box was restenciled to account for total 198 adult life jacket count.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 April 2017 Resolved
Properly secure loose electrical junction box aft engine room bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2017 Resolved
Properly protect loose individual wiring above low voltage panel aft of the Engine room bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2017 Resolved
Properly secure individual wires to backside of start power switch on stbd side console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 April 2017 Resolved
Remove low voltage ground wire to hull port side console
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 April 2017 Resolved
Double clamp all jacket water hosed to keel cooler connectios.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 5 May 2017
Resolution: Cleared to the satisfaction of the attending marine inspector.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 September 2016 Resolved
Starboard shaft sheared approximately 1" forward of shaft seal.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 4 September 2016
Resolution: shaft replaced.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 May 2016 Resolved
Post SAP name and contact information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Poster with required information place on vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2016 Resolved
Fulfill content requirements of first aid kit IAW 160.041.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: New first aid kit provided with all required items and marked externally with the expiration date of appropriate items.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 May 2016 Resolved
Conduct drills, MOB, Firefighting, and Security with seasonal crew once on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 7 June 2016
Resolution: U/W drills completed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2016 Resolved
Provide proof of FCC Radio Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 19 May 2016
Resolution: Vessel has a valid FCC Radio Safety Certificate with annual servicing certificate provided.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 10 May 2016 Resolved
Daily inspections are not being conducted. Log daily vessel inspections IAW EPA VGP requirements. [name withheld], CG Sector Buffalo NY, [phone withheld], [email withheld]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Review of vessel log finding daily check are being completed and logged. Discussed with POC requirements finding adequate knowledge of required rounds.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 10 May 2016 Resolved
Routine inspections are not being conducted. Document and acknowledge vessel inspections IAW EPA VGP requirements appendix K. [name withheld], CG Sector Buffalo NY, [phone withheld], [email withheld]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Reviewed vessel log and VGP forms finding requirement satisfied.
Stability › Unintentional Flooding › General
Issued 10 May 2016 Resolved
Replace bilge suction strainer in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Entered lazarette and inspection installation of new suction strainer finding arrangement sat.
Fire Fighting › Firemans Outfit › Axe
Issued 10 May 2016 Resolved
Install fire axe in appropriate mount.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Fire axe mounted to bridge bulkhead and appropriately marked.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 May 2016 Resolved
Starboard ring life buoy, secure lifeline around body of ring buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Inspection of life buoy provided line attached to grab line vice as required around the body. POC corrected on the spot.
Lifesaving › Lifefloat › Lifeline
Issued 10 May 2016 Resolved
All lifefloats properly secure all lifeline hanks with twine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Inspected installations finding requirement satisfied.
Lifesaving › Lifefloat › Painter
Issued 10 May 2016 Resolved
Aft lifefloats remove electrical tape from painters and properly secure with twine
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Inspected installations finding requirement satisfied.
Lifesaving › Lifefloat › Markings
Issued 10 May 2016 Resolved
Topside lifefloat; A. Properly secure waterlight around body of lifefloat. B. Stencil vessel name on paddles. C. Renew type II retro reflective material on lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: Inspected installations finding requirement satisfied.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 10 May 2012 Resolved
Improve crankcase ventilation exhaust in engine room to reduce oil misting in compartment.
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 31 May 2012
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 10 May 2012 Resolved
Install guard / screen on port crankcase ventilation exhaust fan.
Due 1 June 2012
Resolved 31 May 2012
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2012 Resolved
Repair shore power / junction box connections.
Due 1 June 2012
Resolved 31 May 2012
Lifesaving › Launching Appliances › Release Mechanism
Issued 10 May 2012 Resolved
Replace expired EPIRB hydrostatic release.
Due 1 June 2012
Resolved 31 May 2012
Lifesaving › Lifefloat › Painter
Issued 11 May 2009 Resolved
Properly stow painter on wheelhouse roof lifefloat.
Due 25 May 2009
Resolved 22 May 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 May 2009 Resolved
Secure refrigerator and keg cooler to prevent shifting underway.
Condition: Improper Installation
Due 25 May 2009
Resolved 22 May 2009
Electrical › Electric Supply System (service) › Cable
Issued 11 May 2009 Resolved
Properly support electrical wiring in engine room & aft void IAW 46CFR120.340(4).
Condition: Improper Installation
Due 11 June 2009
Resolved 22 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2009 Resolved
Replace electrical connector on STBD main engine glow plug.
Condition: Unknown
Due 25 May 2009
Resolved 22 May 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Waste Heat Recovery
Issued 11 May 2009 Resolved
Fix or replace cracked coolant line for generator overflow tank.
Due 25 May 2009
Resolved 22 May 2009
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 May 2009 Resolved
Repair visual high water alarm in wheelhouse.
Due 25 May 2009
Resolved 22 May 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 May 2007 Resolved
Emergency lighting did not activate when pushing the "test" button. Proper operation of emergency lighting in the forward main deck passegner cabin will need to be proven.
Action required: 705 - Other - as specified
Due 28 May 2007
Resolved 17 May 2007
Resolution: Emergency lighting is now working to proper operation.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 May 2007 Resolved
Complete hydro-testing of B-II fire extinguisher in the engine room. Extinguisher has expired past 5 year hydro-test date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Hydro-testing of B-II fire extinguisher in the engine room has been completed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 May 2007 Resolved
Provide properly working portable lighting in entrance of machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Portable lighting is now operating properly at entrance to machinery space.
Fire Fighting › Firemans Outfit › Axe
Issued 14 May 2007 Resolved
Properly stencil fire axe with name of the vessel.
Action required: 705 - Other - as specified
Due 28 May 2007
Resolved 17 May 2007
Resolution: Fire axe is now properly senciled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2006 Resolved
install metal supports spaced not more that 24" apart in such a manner as to avoid chafing on the wiring attached to the top canopy
Due 25 June 2006
Resolved 19 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 25 May 2006 Resolved
move one B-II fire extinguisher from the engine room to outside the engine room in close proximity to the space
Due 25 June 2006
Resolved 19 June 2006
Engineering › Reduction Gearing/Clutches › Shaft
Issued 24 July 2005 Resolved
Replace port shaft and prove proper operations prior to returning vessel to commercial service.
Action required: 705 - Other - as specified
Due 24 July 2005
Resolved 28 July 2005
Resolution: MSU Cleveland complete damage survey witnessing satisfactory installation of new shaft and fit-up of prop.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 May 2005 Resolved
Operator does not have an EAP program and does not display required information.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 23 June 2005
Resolution: EAP information properly displayed.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 May 2005 Resolved
Replace chaffed cable in steering lazarett in way of forward bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 23 June 2005
Resolution: Cable replaced
Fire Fighting › Fire Pumps › Arrangement
Issued 20 May 2005 Resolved
Prove proper operation of fire pump pressure gauge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 23 June 2005
Resolution: Gauge tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 May 2005 Resolved
Inspect all life jackets and replace retro-reflective material as needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 June 2005
Resolved 23 June 2005
Resolution: sat
Engineering › Bilge Water Management System
Issued 2 May 2002 Resolved
Replace bilge suction strainer in aft compartment. LEGACY COMPONENT DESC: Strainer
Due 2 June 2002
Resolved 13 June 2002
Lifesaving
Issued 2 May 2002 Resolved
Store all lifesaving, firefighting, and other safety equipment in accordance with applicable regulations.
Due 2 June 2002
Resolved 13 June 2002
Operations/Management › Drills/Instruction
Issued 2 May 2002 Resolved
Conduct drills in presence of marine inspector.
Due 2 June 2002
Resolved 13 June 2002
Lifesaving
Issued 3 May 2001 Resolved
REPLACE EPIRB RELEASE MECHANISM PRIOR TO IT'S 31MAY01 EXPIRATION DATE
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 8 June 2000 Resolved
PROVIDE PROPER AMOUNT OF CHILD SIZE PFD FOR EACH PERSON UNDER 90 POUNDS IN ACCORDANCE WITH 46 CFR 180.71(b).
Condition: Unknown
Due 8 June 2000
Resolved 6 September 2000
Lifesaving
Issued 26 May 2000 Resolved
update contents of first aid kitin accordance with 121.710/160.041
Condition: Unknown
Due 26 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 26 May 2000 Resolved
provide proper nozzles for fire hoses in accordance with 118.320
Condition: Unknown
Due 26 May 2000
Resolved 31 May 2000
Lifesaving
Issued 26 May 2000 Resolved
equip the 5 lifefloats with the required equipment, retroreflective tape, paddles, lights and provide float free configuration to their storage
Condition: Unknown
Due 26 May 2000
Resolved 31 May 2000
Navigation
Issued 26 May 2000 Resolved
reconfigure navigation lights to conform with specifications found in annexI of the navigation rules
Condition: Unknown
Due 26 May 2000
Resolved 31 May 2000
Construction/Loadline
Issued 26 May 2000 Resolved
replace suction hose on aux. bilge pump on port side main engine
Condition: Unknown
Due 26 May 2000
Resolved 31 May 2000
Engineering
Issued 4 May 1999 Resolved
REPLACE F/O TANK VENT SCREENS.
Condition: Unknown
Due 21 June 1999
Resolved 26 July 1999
Documentation
Issued 4 May 1999 Resolved
PROVIDE STATION BILL.
Condition: Unknown
Due 21 June 1999
Resolved 15 June 1999
Documentation
Issued 4 May 1999 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 21 June 1999
Resolved 26 July 1999
Accommodation/Occupational Safety
Issued 4 May 1999 Resolved
PROVIDE 3/4 FULL LEVEL INDICATOR FOR SEWAGE HOLDING TANK
Condition: Unknown
Due 21 June 1999
Resolved 26 July 1999
Construction/Loadline
Issued 11 March 1999 Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REGULATIONS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Unknown
Issued 6 May 1997 Resolved
PROVIDE SECURE STORAGE FOR CO2 BOTTLES IN FWD STOREROOM.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Unknown
Issued 6 May 1997 Resolved
OPERATING CREW TO PERFORM SATISFACTORY DRILLS WHEN FULLY MANNED.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Unknown
Issued 6 May 1997 Resolved
PROVIDE CURRENT FCC GREAT LAKES RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Unknown
Issued 6 May 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 6 May 1997 Resolved
VESSEL LIMITED TO CARRIAGE OF 222 PEOPLE UNTIL ADDITIONAL LIFE PRESERVERS PROVIDED.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Unknown
Issued 6 May 1997 Resolved
REMOVE OUT OF HYDRO CO2 BOTTLES IN STORAGE ROOM.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 3 May 1996 Resolved
Renew stenciling on life floats and ring buoys iaw 46 CFR 122.604.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Post to the satisfaction of the attending USCG marine inspector Emergency Instructions at the operating station.
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Navigation
Issued 3 May 1996 Resolved
Obtain to the satisfaction of the attending USCG marine inspector current Light List or appropriate extract.
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Post to the satisfaction of the attending USCG marine inspector Emergency Radio Placard._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Navigation
Issued 3 May 1996 Resolved
Obtain to the satisfaction of the attending USCG marine inspector most current Inland Rules of the Road (NAVRULES).
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Post to the satisfaction of the attending USCG marine inspector PFD placard.
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Renew to the satisfaction of the attending USCG marine inspector retroreflective material on 35 adult and 10 child PFDs._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Replace onboard additional sat. type 1 PFDs to bring numbers onboard to that required by COI.
Condition: Unknown
Due 3 May 1996
Resolved 7 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Conduct to the satisfaction of the attending USCG marine inspector fire andman overboard drills iaw 46 CFR 122.520 & .524.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Lifesaving
Issued 3 May 1995 Resolved
Post Emergency Checkoff List in conspicious place accessible to crew and passengers iaw 46 CFR 185.25-1_x001C_
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
Replace three missing adult PFDs to the satisfaction of the attending CoastGuard Marine Inspector prior to operating vessel with more than 227 personson board.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Electrical
Issued 3 May 1995 Resolved
Reinstall missing lights and globes.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
MARK FUEL SHUTOFF PER 46 CFR 185.30-20.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Fire Fighting
Issued 10 May 1994 Resolved
PROVIDE 1 ADDITIONAL 1&1/2" x 50' FIRE HOSE PRIOR TO TAKING PASSENGERS FOR HIRE.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Lifesaving
Issued 10 May 1994 Resolved
HOLD MAN OVERBOARD AND FIRE DRILLS UPON THE RETURN OF THE VESSEL'S CREW.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 21 October 1993 Resolved
RENEW TO ORIGINAL STBD DECKHOUSE BULKHEAD (EXTERIOR) IN VICINITY OF VENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Engineering
Issued 21 October 1993 Resolved
REPLACE OR REMOVE KEEL COOLER VALVE IN COMPARTMENT #2_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1993
Resolved 22 October 1993
Construction/Loadline
Issued 21 October 1993 Resolved
REPLACE DETERIORATED BILGE STRAINERS IN VOID AREA PORT SIDE IN VICINITY OF COMPARTMENT #2 AND FOREPEAK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1993
Resolved 22 October 1993
Construction/Loadline
Issued 21 October 1993 Resolved
REPLACE TO ORIGINAL DETERIORATED HULL PLATING IN VICINITY OF FRAMES 1 AND 2STBD SIDE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1993
Resolved 22 October 1993
Construction/Loadline
Issued 21 October 1993 Resolved
CROP AND RENEW DETERIORATED FRAMING AND KEELSON IN FOREPEAK TO ORIGINAL TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Engineering
Issued 11 May 1992 Resolved
Provide nut for main diesel engine foundation bolt where missing, (inboard aft mount for port engine.)
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Engineering
Issued 11 May 1992 Resolved
Provide approved F/O supply and return hoses for S/S generator._x001C_ (46 CFR 182.20-40)
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Deck/Cargo
Issued 11 May 1992 Resolved
Provide suitable second anchor.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 11 May 1992 Resolved
Provide battery for "ACR" water light prior to carrying passengers.
Condition: Unknown
Due 15 June 1992
Resolved 15 May 1992
Fire Fighting
Issued 9 May 1989 Resolved
PROVE OPERATION OF MAIN ENGINE DRIVEN FIRE AND BILGE PUMP.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Lifesaving
Issued 9 May 1989 Resolved
PROPERLY MARK ALL LIFE PRESERVER STORAGE BOXES AS REQUIRED BY 46CFR185.30
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Navigation
Issued 8 May 1987 Resolved
PROVE PROPER OPERATION OF ENGINE START FROM PILOT HOUSE.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Navigation
Issued 8 May 1987 Resolved
PROVIDE LIGHT LIST
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Navigation
Issued 8 May 1987 Resolved
PROVIDE NOTICE TO MARINERS
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Lifesaving
Issued 16 May 1986 Resolved
10 ADULT PFD FOUND UNSERVICABLE
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Lifesaving
Issued 16 May 1986 Resolved
FLOAT FREE LINKS INPROPERLY INSTALLED ON LIFE FLOATS
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986

Casualty record · 3

24 July 2005Routine · role: Involved in a Marine Casualty · activity 2522712
20 August 2005Routine · role: Involved in a Marine Casualty · 1 injured · activity 2478517
1 October 2016Routine · role: Involved in a Marine Casualty · activity 6013183
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.