Inspection history · 19
5 March 2025
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069247
21 February 2024
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7868443
14 February 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865213
27 February 2023
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7642874
2 February 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631143
13 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608561
28 February 2022
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7403491
23 February 2022
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7389181
3 June 2021
Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 7215067
11 March 2021
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7152742
3 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6920017
25 February 2020
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914886
2 December 2019
Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6866796
17 June 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6717200
26 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6631693
5 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6366042
20 February 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6358357
21 February 2017
Internal Structural Exam · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6081626
17 March 2016
Deficiency Check · Internal Structural Exam · Examination of Repairs · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5835563
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2025
Resolved
A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle ... The bell or gong or both may be replaced by other equipment having the same respective sound characteristics, provided that manual sounding of the prescribed signals shall always be possible. During testing, the horn was found to be inoperable. Conduct repairs to the satisfaction of the attending Marine Inspector.
33 CFR 83.33(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 14 April 2025
Resolution: Received video of horn.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 March 2025
Resolved
The marine employer must ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of subpart 4.06 of this chapter. Marine Inspector identified that the alcohol test swabs on board were expired. Replace expired test swabs.
46 CFR 16.240
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 12 March 2025
Resolution: Operator replaced expired alcohol test swabs. Sent photos to Marine Inspector for resolution.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 5 March 2025
Resolved
At a minimum, each placard must notify the reader of the operating requirements contained in §§ 151.67 through 151.73 as they apply to that ship. The following requirements should also be prominently stated:(1) The discharge of all garbage is prohibited into the navigable waters of the United States and into all other waters except as specifically allowed;(2) The discharge of all forms of plastic into all waters is prohibited; (3) person who violates the above requirements is liable for civil and/or criminal penalties; and(4) Regional, state, and local restrictions on garbage discharges also may apply. Marine Inspector identified that the garbage placard on board contained insufficient information to meet the requirement. Replace garbage placard with one that meets the requirements of 33 CFR 151.59(c).
33 CFR 151.59(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 14 April 2025
Resolution: Operator replaced old garbage placard with updated garbage placard containing the requirements identified in 33 CFR 151.59.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 March 2025
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Marine Inspector identified a cracked weld seam near the forward portion of the collision bulkhead overhead. Conduct repairs to the satisfaction of the Attending Marine Inspector.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 February 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must: (1) Be approved by the Commandant;(2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector:...(4) Be installed in accordance with the manufacturer's instructions. System has been modified using unauthorized parts. Restore to original and have certified by NFPA certified technician.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2024
Resolved 15 March 2024
Resolution: documentation was provided of fire servicing report and has been uploaded to the documents tab
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 February 2024
Resolved
A vessel under 46 CFR 175.110(c) requirements must conduct a training program to address firefighting proficiency,emergency egress and must include; Training in the use and location of firefighting equipment and general firefighting knowledge and egress for each member of the crew. No logs were provided showing the crew training for fire fighting and egress.
46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 4 June 2024
Resolution: Recieved documents showing corrected deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 February 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Master of the vessel has expired medical certification.
46 CFR 10.301
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 4 June 2024
Resolution: Verfied that medical certificate was receieved.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 14 February 2024
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements;the radio operator must hold a marine radio operator permit or higher class license. Master of the vessel does not have a marine radio operator permit.
47 CFR 80.159(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 7 March 2024
Resolution: documentation was provided of MROP and has been uploaded to the documents tab
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 February 2024
Resolved
Each vessel must have permanent draft marks at each end of the vessel. Vessel is missing draft marks.
46 CFR 185.602(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 11 March 2024
Resolution: Corrected defieciency on during drydock exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 February 2024
Resolved
Through hull fittings and shutoff valves must be metallic. Through hull fittings on Port/STBD side are plastic.
46 CFR 182.720(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 11 March 2024
Resolution: Verified through hull replaced with metallic valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2023
Resolved
A portable hand bilge pump must be: capable of pumping water, but not necessarily simultaneously, from all watertight compartments. The hand bilge pump for the forward void in front of the collision bulkhead does not provide sufficient suction to effectively de-water the space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 15 March 2023
Resolution: Received verification of the installation of new hand pump for the forward void.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2023
Resolved
A hatch exposed to the weather must be watertight. The hatch to the forward void is not watertight and is permitting an ingress of water from the deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 26 March 2023
Resolution: Received satisfactory evidence of new seal for hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2023
Resolved
A hatch cover must: be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The hatch cover to the forward void is not secured to the vessel by any means.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 15 March 2023
Resolution: Received satisfactory evidence of securing device for hatch cover.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 February 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The anchor light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 13 March 2023
Resolution: Received satisfactory evidence of repairs of anchor light.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 February 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The Communications Act Safety Radiotelephony Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 13 March 2023
Resolution: Received satisfactory evidence of renewed certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 February 2022
Resolved
The construction and arrangment of a vessel must allow the safe operation of the vessel IAW the terms of its COI. A cracked weld was observed in the STBD engine room FWD outboard side on an overhead frame where the frame is welded to the deck. Another crack was found on the deck/frame used for support for the ladder. Deficiency must be corrected prior to next credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 March 2022
Resolution: Accepted photos for repaired welds.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 March 2021
Resolved
For fixed-Gas fire extinguishing system, inspections and tests required by table 176.810 (b) owner or operator must provide satisfactory evidence to the [name withheld] noticed there were no service records for the Fire Boy equipment being properly tested by qualified servicing facility. Vessel is to have Fire Boy tested in accordance with Table 176.810(b).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2021
Resolution: Vessel rep provided picture of servicing documentation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2020
Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible for the intended voyage. The chart carried on board was out dated and did not have corrections/updates. Replace with a new and updated chart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2020
Resolved 11 March 2020
Resolution: Accepted photo of operators receipt as proof of purchase for a new chart for the Monterey bay area.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 March 2020
Resolved
The master and crew of a vessel shall have mounted emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard conditions. The posted emergency instructions for man overboard do not accurately reflect the procedure followed by the crew. Update the emergency instructions using 46 CFR 185.512 as guidance to accurately reflect vessel procedures and mount at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2020
Resolved 11 March 2020
Resolution: Operator updated emergency procedures placard and sent a photo of it corrected and properly posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2019
Resolved
Submersible electric bilge pumps must meet the requirements in UL1113. Vessel's bilge pumps did not meet standard. UL 1113 approved electric bilge pumps shall be installed.
46 CFR 182.520(e)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Purchased UL approved bilge pumps. (see documents for photos).
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 26 February 2019
Resolved
Fuel tank vent pipes shall be installed gradient upward to prevent fuel from being trapped in the line. Tank vent line was installed without upward gradient, instead utilizing a drain to prevent the entrapment of fuel oil. Drain is made of PVC in lieu of approved piping. Vessel shall install drain meeting requirements of 46 CFR 182.455 (a)(2).
46 CFR 182.450(h)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Fuel tank vent pipe installed with approved piping material (see documents for photos).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart and in such a manner as to avoid chafing and other damage.
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Metal electrical wire supports properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 February 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Current chart is from 2013. Update chart from 2013 or buy an up-to-date chart.
46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Updated chart was purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 February 2019
Resolved
At each initial and subsequent inspection for all observed unsafe practices must be corrected. Supports to
3-way valve in both engine room spaces were made of
looped plastic zip ties. Provide permanent supports for
3-way valve.
46 CFR 176.830(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Permanent metal bracket and supports were added.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 February 2019
Resolved
Must provide satisfactory evidence of required servicing of all three portable fire extinguishers and both pre-engineered fixed gas fire extinguishing systems to the marine inspector. Servicing is due at the beginning of March. Provide servicing receipt once complete.
46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Proof of portable fire extinguishers servicing was provided (see documents for photos).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 February 2019
Resolved
An inflatable buoyant apparatus must be serviced at a facility specifcally approved by the Commandant no later than the month and year on its servicing sticker. Although no overdue, servicing of the IBA and hydrostatic release is due at the end of this month. Provide servicing receipt once complete.
46 CFR 185.730(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 18 March 2019
Resolution: Proof of liferaft servicing was provided (see documents for photos).
Construction/Loadline › Hull › Side Shell
Issued 18 March 2016
Resolved
Make proper repairs to crack in stbd hull outboard at the chine in amidship void. Prove sideshell is watertight to the satisfaction of marine inspector.
Due 21 March 2016
Resolved 21 March 2016
Resolution: Damage repaired during emergency drydock. Repairs found satisfactory by attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2016
Resolved
Remove portable cables (extension cords) connecting coffee maker and microwave.
Due 15 April 2016
Resolved 21 March 2016
Resolution: Extension cords removed to satisfactory of attending marine inspector.