Records from 2014 to 2026. Most recent: inspection, 7 July 2026.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: annual maintenance and recharging of extinguishers. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. All portable fire extinguishers and the Fireboy system were last serviced in September 2024.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2025
Resolution: The portable and fixed extinguishers have been serviced by [name withheld] Services LLC.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 December 2025
Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The battery of the vessel's EPIRB was found to be expired. The vessel may not transit more than three miles from the coastline with passengers until these requirements are met.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 2 December 2025
Resolution: The vessel's EPIRB has been fitted with a new battery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 December 2025
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. A stream of water was noted emanating into the lazarette space from the bulkhead just below the exhaust piping penetration.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 5 March 2026
Resolution: MI satisfactorily inspected the repaired exhaust piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2025
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. One of the two clamps on the flexible exhaust piping in the engine room was found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 4 December 2025
Resolution: New hose clamps have been installed on the exhaust piping.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 18 August 2025
Resolved
Provide repair plan for and complete repairs on the aft port side rub rail where damage was noted after the sling removed the vessel from the water.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2025
Resolved 21 August 2025
Resolution: Repairs were completed on the port side rub rail.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 August 2025
Resolved
Make repairs to the external rail stanchions as follows:
1P - secure stanchion bracket and repair base damage.
2P - secure stanchion bracket.
6P/7P - secure the stanchion brackets with backing plates as discussed.
2S - repair deck material to provide good wood below the stanchion bracket for screw fastenings.
All - caulk/seal all stanchion brackets to the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2025
Resolved 21 August 2025
Resolution: Repairs were completed in way of each of the noted stanchions.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 18 August 2025
Resolved
Remove damaged fiberglass and wood on port quarter, provide repair plan, and effect repairs.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2025
Resolved 21 August 2025
Resolution: Repairs were completed on the port quarter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 August 2025
Resolved
Mount the submersible bilge pumps in the engine room and lazarette spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 21 August 2025
Resolution: The two submersible bilge pumps have been mounted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 November 2024
Resolved
Provision must be made for closing all supply duct cowls for a space protected by a fixed gas extinguishing system. The vessel's port and starboard vent covers were unable to be properly affixed due to deteriorated Velcro strips.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: New Velcro was found to be installed and the vent covers were appropriately closed off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The alternator belt was found to be loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 3 December 2024
Resolution: The alternator belt was found to be tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required. Three flexible hoses in the forward part of the engine room need second clamps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: Double hose clamps were added to the three identified flexible pipes in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 November 2024
Resolved
A vessel on a limited coastwise route must carry six hand red flare and six hand orange smoke distress signals. The vessel only maintained four red hand flare and four hand orange smoke distress signals on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 22 November 2024
Resolution: Additional red hand flares were provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 November 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard. Each of the vessel's fire buckets were in excess of the required size.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 22 November 2024
Resolution: Holes were drilled in the existing fire buckets at the 2.5 gallon mark.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2024
Resolved
Each ring life buoy must be approved in accordance with 46 CFR subchapter Q. The grab line had been replaced in the past and is now too short.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: Received a picture of the life ring re-strung correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2024
Resolved
Each life jacket must be marked with Type I retro reflective material. Two life jackets were noted missing the material on the top.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 22 November 2024
Resolution: Retro reflective tape was added to the identified life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard between three and six feet in length, securing the waterlight around the body of the ring life buoy. it must be attached to the lanyard with a corrosion-resistant clip. The waterlight lanyard was found to be more than six feet in length and no clip was present.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: The lanyard was shortened and a corrosion-resistant clip was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 November 2024
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch stays were not present for the forecastle, forward, and aft hatches.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: Stays have been installed on the three identified deck hatch covers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 November 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers and crew. The clips of many of the removable rails were found to be deteriorated and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 24 November 2024
Resolution: New clips have been installed for the removable deck rails.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 November 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The vessel crew could not prove compass illumination.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2024
Resolved 10 January 2025
Resolution: Received pictures from Hal showing the newly-installed compass with illumination.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 November 2024
Resolved
Abandon ship, man overboard, and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the date of the drill and training and a general description of the drill scenario and training topics. The vessel log was missing some logs of the drills and did not contain entry information.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 3 December 2024
Resolution: The vessel crew is documenting their drills in the vessel log.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 November 2024
Resolved
Each EPIRB must be tested monthly, which shall be logged or otherwise documented. Vessel crew said they do not test the EPIRB and therefore have not logged the tests.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 3 December 2024
Resolution: The vessel crew is documenting their EPIRB tests in the vessel log.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 November 2024
Resolved
A vessel must carry adequate and up-to-date tide/current tables. These tables were not made available on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 7 December 2024
Resolution: A paper copy of the tide tables are maintained on board the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 November 2024
Resolved
A marine employer shall comply with the requirements of
46 CFR 4.06. The marine employer must have a sufficient
number of alcohol testing devices readily accessible on
board the vessel to determine the presence of alcohol in
the system of each individual who was directly involved
in a Serious Marine Incident. The vessel could not produce alcohol testing devices for all crewmembers serving on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2024
Resolved 7 December 2024
Resolution: The vessel maintains six (in excess of required amount) alcohol test strips on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 November 2024
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. Vessel is required to have a crewmember with a valid FCC operator permit. Captains Jason and Lauren do not possess a permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2024
Resolved 3 January 2025
Resolution: Owner provided proof of receipt for the two Marine Radio Operator Permits.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 November 2024
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. The vessel's Communications Act Safety Radiotelephony Certificate has the incorrect call sign.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2024
Resolved 11 December 2024
Resolution: Owner provided a picture of the newly-issued FCC Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2024
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Three life jackets were not appropriately marked.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 November 2024
Resolution: Crewmembers marked the life jackets during the inspection.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 25 August 2023
Resolved
Inspection of all water tight closures in the hull, decks and bulkheads including through hull fittings and sea valves. Repair leak in stern bulkhead were leaking exhaust system is visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 12 September 2023
Resolution: Exhaust leak has been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2023
Resolved
On a vessel of at least 7.9 meters in length, a visual and audible alarm must be provided at the operating station. Replace broken float swith located in the stern compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 12 September 2023
Resolution: Float switch has been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2023
Resolved
Twist-on type connectors may not be used in making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Remove wire nuts from vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 12 September 2023
Resolution: Wire nut has been removed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 August 2023
Resolved
A vessel must carry adequate and up-to-date: Coast Guard light list, tide tables and Current tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 12 September 2023
Resolution: Up to date tables have been placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2022
Resolved
A vessel reqiured to have a EPIRB must have a FCC type accepted category, 406 MHz EPIRB installed to automatically float free and activate. Hydrostatic release had expired last month.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2022
Resolved 16 October 2022
Resolution: Installed new Hydrostatic Release.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 October 2022
Resolved
Certification or licensing by a state or local jurisdiciction as a fire extinguishing serving agency will be accepted by the CG as meeting the personnel certification requirement of NFPA 10 for annual maintenance and recharging of extinguishers. Current inspection stickers or paperwork must be provided to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2022
Resolved 15 October 2022
Resolution: All extinguishers were serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2022
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Remove and replace all twist type connectors with proper connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2022
Resolved 15 October 2022
Resolution: Heat shrink butt connectors installed on all connections where twist on connectors were found.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a active station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 24 December 2021
Resolution: Receive photo documentation of new FCC cert.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 November 2021
Resolved
On a avessel of at least 26ft. in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Visual alarm was not working in every space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
Resolution: Vessel SAT. tested alarms at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 October 2020
Resolved
Stowage markings were sun faded and need renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2020
Resolved 13 November 2020
Resolution: New labels affixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2020
Resolved
Double hose clamp exhaust cooling supply hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2020
Resolved 13 November 2020
Resolution: Clamp attached and secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2020
Resolved
Lifebouy did not have the approperiate lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2020
Resolved 27 October 2020
Resolution: 3-6' lanyard attached.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 November 2019
Resolved
Orange smoke flares expired. Flares are required before vessel can take passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 December 2019
Resolved 18 November 2019
Resolution: New flares provided prior to the end of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2019
Resolved
Multiple PFDs (11 Adult and 03 child) retroreflective tape inadequate. Vessel passenger count restricted to number of remaining serviceable PFDs until repaired/replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 18 December 2019
Resolution: PFDs fixed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 November 2019
Resolved
Vessel is required to have the VHF-FM radio inspected every five years by the FCC. Vessel certificate was out of date.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 1 December 2019
Resolution: Vessel had radio inspected and serviced by a qualified FCC tech.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019
Resolved
Ring life buoy lifeline beyond service life. Replace lifeline.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Life line replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2019
Resolved
Eyewash in first aid kit has expired. Replace with new unexpired item.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 6 December 2019
Resolution: Replaced with new.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 November 2019
Resolved
Engine room hatch gasket in disrepair. Replace/repair gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 6 December 2019
Resolution: E/R hatch gasket replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 November 2019
Resolved
Repair leak in forward cabin window.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 6 December 2019
Resolution: Leak secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2019
Resolved
The required water light was of an older design not currently accepted by regulations, water light did not flash. Require new water light.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Vessel purchased new approved water light and placed into service.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 October 2018
Resolved
Port side engine room support needs replacing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2018
Resolved 17 October 2018
Resolution: Engine room deck support replaced. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 October 2018
Resolved
Thru bulkhead penetrations need to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2018
Resolved 17 October 2018
Resolution: Thru bulkhead penetrations were sealed effectively.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 October 2018
Resolved
Fire bouy must be serviced annually.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2018
Resolved 17 October 2018
Resolution: Fire bouy was serviced and tested.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 October 2018
Resolved
Replace mast head light with a clear lens.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2018
Resolved 17 October 2018
Resolution: Lens replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2018
Resolved
Vessels electrical wiring must be in accordance with standards. Remove loose wires and dead ends.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2018
Resolved 24 October 2018
Resolution: Loose wiring and dead ends removed.