Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2026
Resolved
All vessels, 26ft up to 65ft and carry not more than 49 passengers, shall be provided with 01 fixed power pump and 01 portable hand pump. Fixed bilge pump was found to be inoperable. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 June 2026
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 01 child life jacket was found dry-rotted. Decrease passenger count to 23, max child passengers limited to 2. 46CFR180.71
Action required: 705 - Other - as specified
Resolved 12 June 2026
Resolution: Received confirmation of new life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 June 2026
Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, a painter and a light. Floating water light was missing. Vessel restricted to daylight operations. 46CFR180.175(d)
Action required: 705 - Other - as specified
Resolved 11 June 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 1 July 2025
Resolved
Master that was present during this inspection had a valid MMC but did not have the Medical Certification (card)as required by 46 CFR 10.301(a) available for review. Master did not know if he had it or lost it.
Provide medical certificate or attain new medical card showing proof of meeting medical and physical standers IAW 46 CFR 10. 302
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2025
Resolved 10 July 2025
Resolution: Master provided current medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 July 2025
Resolved
Air test of the weld repair to the collision bulkhead failed.
Repair two leaks found during the air test and re-test to the satiscation of the attending marine inspector.
Operator proposed to grind and apply a new complete weld that secures the forward portside of the collision bulkhead to the port bow side shell. this should ensure water tightness.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2025
Resolved 10 July 2025
Resolution: Completed succesful air test of forward port side collision bulkhead repair with no discrepancies noted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Medical kit had multiple items which had exceeded its exipry date. Replace expired items or replace medical kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 10 July 2025
Resolution: Vessel rep provided updated items to replace expired items in first-aid kit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 July 2025
Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40.
Vessel operates on a L,B,S, and LC route and was found with expired Alcohol test strips. Replace alcohol test strips new.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2025
Resolved 10 July 2025
Resolution: Vessel rep provided receipt for newly purchased alcohol test strips enroute from supplier.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2024
Resolved
All portable fire extiguishers installed on vessels shall be of an approved type. MI found 02 fire extinguisher brackets are not of the approved type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 20 June 2024
Resolution: Received pictures. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables. MI noted the vessel had charts and nautical publication out of date or not on vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 7 June 2024
Resolution: Received Pictures of new Charts and Pubs. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2024
Resolved
In addition, a number of child size life jackets equal to 10% of the number of persons permitted on board must be provided. MI noted that 01 child life jacket was unservicable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 7 June 2024
Resolution: Received pictures of new Child life jacket. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Marine inspector observed vessel generator failed to start. Vessel owner determined that generator starter was faulty. Replace starter with new. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 22 May 2023
Resolution: Received, reviewed, and accepted photos from vessel rep showing installation of new generator starter.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 May 2023
Resolved
At each initial and subsequent inspection for certification, re inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine inspector observed bilge piping system susceptible to failure and flooding. Threaded cap needs to be installed on bilge piping system. 46 CFR 176.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 16 June 2023
Resolution: Recieved photos attestting to the proper repair.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 16 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel missing children life jacket donning procedures. Master needs to display proper child life jacket procedures. 46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 16 June 2023
Resolution: Received photo attesting to the proper placement of child PFD instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped. Double hose clamping is required where practicable. Inspector found missing hose clamps on port and startboard wet exhaust. Install required hose clamps. 46 CFR 182.410(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 16 June 2023
Resolution: Recieved photos showing proper installation of hose clamps.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2023
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon buckets. Marine inspector observed only two buckets on board vessel. Master will need to acquire additional fire bucket. 46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 16 June 2023
Resolution: Recieved photo attesting to proper amount of fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2023
Resolved
Each major generator and motor shall be fitted with a name-plate of corrosion-resistant material. Generator on board was missing name-plate with applicable information. Install manufactures name-plate. 46 CFR 183.10-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 7 August 2023
Resolution: Received photograph evidence of custom placard for vessel generator.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Upon examination of required EPIRB, it was found not functional. Vessel owner/operator is not allowed to operate the vessel beyond three miles from the coast line until a replacement EPIRB is properly installed.
46CFR180.64
705c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2022
Resolved 25 May 2022
Resolution: Recieved documentation from operator for replacement EPIRB and updated registration number in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 May 2022
Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Operator was not able to provide any required logs or documentation regarding monthly testing of the EPIRB.
46CFR185.728
50c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 23 May 2022
Resolution: Received copy of maintenance log that was implemented post examination.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2022
Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 50 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. For peripheral body apparatus each strip must extend completely over the top and bottom surface of the body. For box type apparatus, the strip must extend at least 300 mm (12 in.) inboard from the edge over the top and bottom surface. Each strip must be positioned near the center of the side or end, but so that it is not obscured by any strap. A typical arrangement is shown in Figure 160.010-3(p). MI observed degraded retro reflective material on both buoyant apparatus. Owner/Operator to replace as per reference with on hand stock.
46CFR160.010-4
16c.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 25 May 2022
Resolution: Operator provided photo documentation of retro reflective tape replaced on life floats.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 May 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Upon examination of the first aid kit, it did not contain the required items as per the applicable reference.
46CFR184.710
50c.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 16 June 2022
Resolution: Received documentation for replacement first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022
Resolved
The engine cooling water system shall be in accordance with the following provisions: A suitable hull strainer shall be installed in the circulating water intake line.
Upon examination of the main propulsion engines, MI observed the main engine sea water strainers had been removed and straight piped from the hull to engine driven pump.
46CFR182.20-10
50c.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 25 April 2023
Resolution: Owner installed sea strainers. Inspected at AN 7668804.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 May 2022
Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following:
(1) The location of emergency exits, survival craft embarkation areas, and ring life buoys;
(2) The stowage location(s) of life jackets;
(3) Either:
(i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or
(ii) That passengers may contact a crew member for a demonstration as appropriate, prior to beginning an oceans or coastwise voyage;
(4) The location of the instruction placards for life jackets and other lifesaving devices;
(5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and
(6) If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter.
Operator was only able to verbally recite a portion of the information required by the safety orientation. Operator is required to inform passengers of all require
required information listed above.
46CFR185.506
16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 27 May 2022
Resolution: Received confirmation that safety orientation has been drafted and implemented.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 June 2021
Resolution: FCC radio station license issued and post onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2021
Resolved
Portable fire extinguisher must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the [name withheld] fire extinguishers not properly mounted on to approved mounts and found loose allowing for possible accidental movement. Use proper mounting bracket as provided by manufacture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 June 2021
Resolution: Three portable fire extinguishers properly mounted on approved brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2021
Resolved
Life saving equipment must be clearly marked as required. Life rings and life floats found with faded vessel name and/or number of persons. Re-mark lifesaving equipment as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 June 2021
Resolution: Life rings and life float re-marked, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 June 2021
Resolved
Crew training and drills shall be logged and made available for inspection. No logs made available.
Conduct drills, training and log. Make avaliable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 15 June 2021
Resolution: Verified last crew drills and training have been logged on to vsl log book.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 June 2021
Resolved
Port side most outboard MDE exhaust pipe leaking cooling water from the pipe's non-metallic joint into bilge.
Tighten loose clamp to ensure no water leaks out.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 15 June 2021
Resolution: Non metallic flex pipe re-adjusted and tightened to prevent cooling water from leaking into bilge.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2021
Resolved
All vessels must undergo an annual inspection within the 3 months before or after each anniversary date of the vessel's inspection for certification. Vessel did not have an annual inspection conducted in CY2020. Vessel must complete an annual inspection during CY2021 prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 30 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 July 2019
Resolved
Missing all required items in first aid kit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 4 July 2019
Resolution: Received picture of medkit with number of items meeting subchapter T requirements.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 2 July 2019
Resolved
Post correct EAP contact phone numbers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 23 September 2019
Resolution: Received picture of updated EAP info.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 July 2019
Resolved
Have a log bok for fire and abandon ship drills and for survey/repair of lifesaving equipment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 4 July 2019
Resolution: Notified by vessel Master that new logbook has been acquired and will be filled out for drills and maintenance.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 July 2019
Resolved
Connect GPS to VHF-DSC radio and program in the MMSI number.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 3 December 2019
Resolution: GPS connected to DSC-VHF radio and MMSI programmed in.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 July 2019
Resolved
Post in bridge a compass deviation chart.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2019
Resolution: Issued in error, not required.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 July 2018
Resolved
EPIRB battery was inoperable. Request owner provide new battery prior to traveling 3 miles offshore.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2018
Resolved 11 July 2018
Resolution: Owner provided three pictures confirming replacement of new battery and proper installation of EPIRB. All sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 April 2017
Resolved
Replace one child lifejacket with approved type prior to carrying more than 2 child passengers. 46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 11 April 2017
Resolution: Received pictures with new child life jacket with tags still attached.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 6 April 2017
Resolved
Tighten mountings on port side main engine prior to carrying passengers. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2017
Resolved 11 April 2017
Resolution: Received pictures showing bolts on the mountings have been tightened.
Engineering › Steering Gear System › Rudder Bearing
Issued 6 April 2017
Resolved
Tighten rudder post packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 11 April 2017
Resolution: Received pictures that the packing for the rudder post have been tightened.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 7 July 2016
Resolved
During testing of ship's horn, MIs observed a homemade pressure vessel made out of an old propane tank supplying air to ship's horn. A means to relieve pressure was not installed and the system was not a CG approved design. Ordered owner remove and disconnect tank; recommended temporarily using canned air until an appropriate sound producing arrangement was installed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2016
Resolved 11 July 2016
Resolution: Propane tank removed in accordance with CG-835.
Lifesaving › Lifefloat › Lifeline
Issued 7 July 2016
Resolved
Replace rotting grablines on both lifefloats.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 26 July 2016
Resolution: Grablines on both lifefloats have been replaced.
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 July 2016
Resolved
Replace worn retroreflective material on both lifefloats.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 26 July 2016
Resolution: Retroreflective material replaced on both lifefloats.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 7 July 2016
Resolved
Replace non-servicable ring bouy and install properly arranged floating light.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 12 July 2016
Resolution: Ring bouy replaced and properly arranged floating light installed.
Engineering › Generator (propulsion-electric) › Winding
Issued 7 July 2016
Resolved
Windings on generator are dirty and require cleaning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 26 July 2016
Resolution: Generator windings have been cleaned.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 July 2016
Resolved
Replace expired items in first aid kit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 2 August 2016
Resolution: Replaced expired first aid kit items.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 July 2016
Resolved
Vessel needs a valid FCC radio safety certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 2 August 2016
Resolution: FCC radio safety survey complete; new certificate issued.