MAURY USCG vessel records Sign in
← All vessels

IBIS

IBIS is a 1972 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 1985, most recently in June 2022, along with 39 deficiencies and 1 operational control.

Records from 1985 to 2022. Most recent: inspection, 2 June 2022.

Built
1972
Last inspected
2 June 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-47282

Inspections, by type

Years with a record 24 calendar years (1985–2022)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 11.5 ft × 2.1 ft
Registered tonnagegross 20 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELHI MANUFACTURING CORP · DELHI, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSCHENECTADY, NY
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

2 June 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7466650
20 February 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912211
15 June 2018 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443269
17 July 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6211590
25 January 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077126
6 June 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4880838
10 July 2012 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4376192
1 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4204116
26 October 2010 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3873848
15 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3131547
26 November 2007 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3104601
3 November 2005 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2528345
2 November 2004 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2234538
10 February 2004 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2124597
29 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1943612
10 December 2002 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1718921
5 December 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1389524
15 December 1999 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1421768
15 December 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445408
15 December 1997 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 780644
11 December 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1094170
8 December 1995 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880297
13 January 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1132650
13 December 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159254
9 March 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 836284
29 January 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1005496
19 February 1991 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 915170
18 January 1991 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224597
2 October 1985 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1292703

Deficiency record · 39

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 June 2018 Resolved
Vessels over 5 net tons must obtain a certificate of documentation. Owner has applied for COD and is waiting to receive it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2018
Resolved 15 June 2018
Resolution: COD arrived, see documents for picture.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 June 2018 Resolved
Vessel must carry adequate up-to-date publications. Vessel missing coast pilot, light list, and currents/tide tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2018
Resolved 29 June 2018
Resolution: Correct publications now on vessel.
Fire Fighting › Fire Bucket › Availability
Issued 15 June 2018 Resolved
Vessels not required to have a power driven fire pump must have at least 3 2.5 gallon buckets. Vessel only had two fire buckets.
Action required: 10 - Deficiency Rectified
Due 15 July 2018
Resolved 15 June 2018
Resolution: Vessel purchased the required bucket.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 June 2018 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel had none.
Action required: 10 - Deficiency Rectified
Due 15 July 2018
Resolved 15 June 2018
Resolution: Owner purchased the required lights.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2014 Resolved
Permanently install metal support for wiring throughout vessel. IAW 46CFR183.340
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2014
Resolution: Metal support provided for wiring throughout.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 6 June 2014 Resolved
Remove dead end wiring throughout the vessel. IAW 46CFR183.340(H)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2014
Resolution: All dead end wiring removed from vessel.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 June 2014 Resolved
Provide EAP and drug program for company, including the 2013 MIS report. IAW 46CFR 16.401
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2014
Resolution: Company now in compliance with DAPI requirements.
Stability › Intact Righting Energy › General
Issued 6 June 2014 Resolved
Vessel swapped out electric outboard with gasoline without making notification to OCMI. (Operator was unfamiliar with who to contact in regards to request change approval-- stated he contacted NVDC after he had applied for COD to ensure he was cleared, they indicated he was. No contact with MSC or local unit was made. A new stability test is required. IAW 46CFR176.700(B)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2014
Resolution: Stability test conducted 08SEP14. Activity # 4977588
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 August 2012 Resolved
Clean life Jackets
Due 30 August 2012
Resolved 16 August 2012
Stability › Water on Deck › General
Issued 10 July 2012 Resolved
Dry dock vessel for CG inspection and repair for water leak on deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2012
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 10 July 2012 Resolved
Replace life ring
Due 30 August 2012
Resolved 16 August 2012
Engineering › Bilge Water Management System › Pump
Issued 1 December 2011 Resolved
Mount bilge pump.
Due 7 December 2011
Resolved 6 December 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2011 Resolved
Replace first aid kit
Due 7 December 2011
Resolved 6 December 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 November 2007 Resolved
Broken mount for the starboard running light shall be repaired prior to operating at night, but NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 15 January 2008
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 November 2007 Resolved
Vessel shall attach the waterlight to the ring buoy via a 3' lanyard and corrosion resistant clip prior to operating at night, but NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 15 January 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 November 2007 Resolved
Forward embarkation area shall be provided with rails or equivelant means of protection to meet the 39.5" height requirement.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 15 January 2008
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 November 2007 Resolved
The #3 starboard propulsion motor battery shall be replaced due to excessive wastage of the battery caused by acid.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 15 January 2008
Resolution: Corrected
Construction/Loadline › Structures › Trunk
Issued 27 November 2007 Resolved
Vessel is to renew the glass bottom/framing due to excessive leakage NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 15 January 2008
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 November 2004 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION
Due 9 November 2004
Resolved 9 November 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2004 Resolved
POST UPDATED COI REFLECTING DECK HAND AMENDMENT
Due 9 November 2004
Resolved 9 November 2004
Construction/Loadline › Penetrations › Gasket
Issued 2 November 2004 Resolved
REPAIR WATER LEAK ON GLASS BOTTOM
Due 30 November 2004
Resolved 9 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 November 2004 Resolved
RE MARK LIFE JACKETS WITH VESSEL NAME
Due 9 November 2004
Resolved 9 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 November 2004 Resolved
PROVIDE COAST GUARD APPROVED OR EQUIVALENT FIRST AID KIT
Due 9 November 2004
Resolved 9 November 2004
Electrical › Electric Supply System (service)
Issued 10 December 2002 Resolved
Permanently install fuse located on starboard side under after seating, in a watertight electrical box. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2003
Resolved 28 January 2003
Electrical › Electric Supply System (service)
Issued 10 December 2002 Resolved
Install a watertight cap on the electrical charging cable. LEGACY COMPONENT DESC: Cable
Due 30 January 2003
Resolved 28 January 2003
Electrical › Electrical Distribution System (service)
Issued 10 December 2002 Resolved
Properly terminate all loose wiring located in the operators area. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Fire Fighting › Miscellaneous Items
Issued 10 December 2002 Resolved
Add 3 buckets with 10 feet of line attached to be used for additional fire fighting while vessel is in service.
Due 30 January 2003
Resolved 28 January 2003
Personnel › Certificates/Documents/Licenses
Issued 10 December 2002 Resolved
Operators of all vessels are required to have the original license and a copy of current first aid and cpr card onboard while the vessel is carrying passengers for hire. LEGACY COMPONENT DESC: License, Master
Due 30 January 2003
Resolved 28 January 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 December 2002 Resolved
Permanently mount operators seat.
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Engineering › Electric Propulsion System
Issued 10 December 2002 Resolved
Permanently mount guard over control circuit to prevent electric shock to operator. LEGACY COMPONENT DESC: Conductor
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 December 2002 Resolved
Replace the loose /worn retro tape on 8 child life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 30 January 2003
Resolved 28 January 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 December 2002 Resolved
Properly label the location of child life jackets & post donning procedures for all passengers to see. LEGACY COMPONENT DESC: Storage
Due 30 January 2003
Resolved 28 January 2003
Electrical › Lighting (emergency)
Issued 10 December 2002 Resolved
Place 2 electric lights on vessel. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 30 January 2003
Resolved 28 January 2003
Documentation
Issued 15 December 1998 Resolved
PROVIDE OCMI WITH CORRECTED COPY OF DOCUMENTION.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Documentation
Issued 11 December 1996 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION REFLECTING CURRENT VESSEL OWNER.
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Accommodation/Occupational Safety
Issued 11 December 1996 Resolved
POST EMER CHECK-OFF LIST.
Condition: Unknown
Due 18 December 1996
Resolved 23 December 1996
Lifesaving
Issued 11 December 1996 Resolved
MARK CONTAINER/BOX HOLDING SHILD-SIZED PFDS.
Condition: Unknown
Due 18 December 1996
Resolved 23 December 1996
Documentation
Issued 29 January 1992 Resolved
PROVIDE PROOF OF VESSEL DOCUMENTATION. CERTIFICATE OF DOCUMENTATION MUST BEPLACED ABOARD THE VESSEL.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Construction/Loadline
Issued 18 January 1991 Resolved
REPAIR SMALL HOLE (1") LOCATED ON THE INTERIOR BULKHEAD AFT OF THE NUMBER THREE BATTERY, PORT SIDE.
Condition: Unknown
Due 18 January 1991
Resolved 18 January 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.