Records from 2005 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 27
28 May 2026
COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383614
27 May 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395489
24 May 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395587
23 May 2026
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395121
28 May 2025
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8148155
16 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7915606
3 November 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7821489
4 August 2023
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7762335
30 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7701777
31 August 2022
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7548597
30 August 2022
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7871977
29 August 2022
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7553606
18 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7467374
10 June 2021
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7191621
28 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7094614
27 August 2019
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6802537
18 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6720992
2 April 2019
Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6654493
12 February 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6624268
31 October 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6572471
4 October 2018
Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6554600
4 October 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6554765
7 December 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6322952
21 November 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6314082
24 March 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6113850
15 November 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6043903
28 September 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6018159
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2026
Resolved
During inspection of the vessel's propulsion fuel system, the electric fuel pump installed on the Port propulsion engine fuel supply line was found to be faulty, causing an unexpected shutdown of the propulsion engine during operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 30 May 2026
Resolution: Received video evidence from the vessel owner verifying the installation of the fuel pump with no signs of leakage. The vessel's crew operated the boat for several hours without incident.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2024
Resolved
Lifejackets were not on station. Relocate all lifejackets to the appropriate storage area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024
Resolved
Liferings were found with deteriorated retro reflective tape. Replace retro reflective tape on all liferings as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 28 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 May 2024
Resolved
Aft main deck engineroom hatches were not sealed and bolted down. Secure all aft main deck engine room hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2024
Resolved
Port navigation light was inoperable. Repair or replace port navigation light prior to operation beyond dusk or in low visibility.
Action required: 705 - Other - as specified
Resolved 17 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2024
Resolved
Ships newly rebuilt generator was found inoperable. Make repairs to bring generator back into service. Verified generator provides no power or back up to any vital system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2023
Resolved
Masthead light was inoperable. Repair or replace masthead light and associated wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023
Resolved
High water alarm wiring was unprotected in sewage tank space. Secure wiring above float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2022
Resolved
Vessel experienced vibrations in the port shaft and discovered excess water in the bilge. Discover cause and make appropriate repairs to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2022
Resolved 31 August 2022
Resolution: Vessel re-positioned shaft and torqued coupling. Op test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2022
Resolved
Corrosion resistant clip was not installed on the waterlight lanyard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 29 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2022
Resolved
Install protective guard on port engine flywheel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 29 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2021
Resolved
Vessel did not have a current COD reflecting new
ownership.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: NVDC issued updated COD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021
Resolved
Lifejackets were not marked with the vessels name. Label
lifejackets with vessel name as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Lifejackets were marked with vessels new name.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 June 2021
Resolved
Emergency instructions were not updated to reflect
vessels current operating area. Provide updated
emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Emregency Instruction placard was updated to reflect the current operating area and crew.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 June 2021
Resolved
The number of passengers allowed on the upper deck was
not labeled correctly. The maximum number of passengers
allowed on an upper deck must be indicated
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: The upper deck area passenger capacity was labeled IAW stability letter in block lettering at entrance to the upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021
Resolved
The number and identification of the items stowed
inside, and their sizes, must be marked in clearly
legible letters and numbers on each container for life
jackets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Lifejacket boxes were labeled IAW vessels safety plan and a accurate count of items inside.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2021
Resolved
Port side engine room battery box was not secured.
Ensure battery box is secured to protect against
shifting with the roll and pitch of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Battery box was secured to a platform in engine room.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2021
Resolved
Pre engineered Fixed fire fighting system was not
installed to shut down engines during automatic
discharge of agent.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel owner contacted local fire system company to come out and examine and inspect the fire system main engine shutdowns. The company was able to fix the error, witnessed new test while on site.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 10 June 2021
Resolved
Sewage holding tank fill flange was not sealed. Ensure
tank is sealed to not leak or vent into the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2021
Resolution: Sewage holding tank fill flange was sealed.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 10 June 2021
Resolved
Newly assigned crew was not trained in the emergency
operations.The owner, charterer, master or managing
operator shall instruct each crew member, upon first
being employed and prior to getting underway for the
first time on a particular vessel and at least once
every three months, as to the duties that the crew
member is expected to perform in an emergency including,
but not limited to, the emergency instructions listed on
the emergency instruction placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel owner/operator used the time while waiting to clear other deficiencies to conduct proper crew training. Had a discussion with the crew on site regarding emergency instruction to ensure competency.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2021
Resolved
New name and hailing port were not marked on the vessel.
The name of the vessel must be marked on some clearly
visible exterior part of the port and starboard bow and
the stern of the vessel. The hailing port of the vessel
must be marked on some clearly visible exterior part of
the stern of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel name and hailing port were marked to reflect the information on the COD.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 June 2021
Resolved
Copy of MIS report for drug testing was not available.
Ensure compliance with chemical testing reporting
requirements by providing a copy of the previous year
MIS report to the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2021
Resolution: MIS report was printed prior to arrival.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 October 2020
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing for the fixed-gas fire extinguishing systems to the marine inspector. The pre-engineered fixed-gas fire extinguishing had not been annually serviced.
46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: Fixed-extinguishing system was serviced by J.T.'s Fire Extinguisher Service, Inc.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 October 2020
Resolved
A power-driven vessel underway shall exhibit a masthead light forward. Masthead light was inoperable.
46 CFR 183.420
33 CFR 83.23(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: masthead light was replaced and operable
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020
Resolved
The marine employer shall ensure that all persons directly involved in a serious mearine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with 46 CFR 4.06. Alcohol test strips expired 6/2020.
46 CFR 16.240
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: new alcohol test strips were purchased with expiration date 09-15-2022.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 April 2019
Resolved
Vessel struck an object while underway. As a result, vessel’s steering gear was compromised. The following requirements must be meet prior to carrying passengers for hire:
1. Provide a copy of the dive report for inspection of any hull damage that may have incurred as a result of the vessel striking a submerged object.
2. Provide Service Tech Report attesting to the repairs and proper operation of the vessel’s rudder, steering system and associated components.
3. Vessel is required to conduct Sea trials in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2019
Resolved 24 April 2019
Resolution: Vessel Owner provided dive report and Service Tech Report attesting to the repairs and proper operation of the vessel’s rudder, steering system and associated components. In addition, satisfactory Sea trials were conducted in the presence of an attending
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2018
Resolved
Provide a copy of a dive report for inspection of any hull damage incurred from vessel running aground.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 10 October 2018
Resolution: Vessel Operator provide this office with a valid copy of a dive report - there were no noticable damage in hull or propulsion system - ALL SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2018
Resolved
Vessel required to conduct Sea Trial in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 11 October 2018
Resolution: Vessel Sea Trial were conducted in the presence of an attending Coast Guard Marine Inspector; ALL SAT.
Fire Fighting › Fire Pumps › Pressure
Issued 21 November 2017
Resolved
Fire pump was not able to produce more than 20 PSI at outlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 November 2017
Resolved
Replaced expired battery with approved battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 November 2017
Resolved
Emergency instructions not ship specific.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Construction/Loadline › Hull › Bottom Plating
Issued 15 November 2016
Resolved
Provide Repair Plan to address the areas of concern (i.e. pitting) that were identified in way of the bottom hull plating of the vessel’s Starboard and Port mid-sections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified Repair Plan and the actual repair work performed were IAW with the appropriate NVIC. In addition, verifed proof of Ultrasonic Testing Report that owener provided to this office.