SENECA SPIRIT

SENECA SPIRIT is a 1998 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in May 2026, along with 32 deficiencies and 7 casualty investigations between 2005 and 2026.

Records from 2005 to 2026. Most recent: inspection, 28 May 2026.

Built
1998
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG6125
472831
Flag
UNITED STATES
Maury page id
psix-472831

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded6
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 16.0 ft × 4.5 ft
Registered tonnagegross 71 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWATKINS GLEN, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 27

28 May 2026 COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383614
27 May 2026 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395489
24 May 2026 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395587
23 May 2026 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8395121
28 May 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8148155
16 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7915606
3 November 2023 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7821489
4 August 2023 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7762335
30 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7701777
31 August 2022 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7548597
30 August 2022 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7871977
29 August 2022 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7553606
18 May 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7467374
10 June 2021 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7191621
28 October 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7094614
27 August 2019 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6802537
18 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6720992
2 April 2019 Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6654493
12 February 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6624268
31 October 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6572471
4 October 2018 Deficiency Check · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6554600
4 October 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6554765
7 December 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6322952
21 November 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6314082
24 March 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6113850
15 November 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6043903
28 September 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6018159

Deficiency record · 32

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2026 Resolved
During inspection of the vessel's propulsion fuel system, the electric fuel pump installed on the Port propulsion engine fuel supply line was found to be faulty, causing an unexpected shutdown of the propulsion engine during operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2026
Resolved 30 May 2026
Resolution: Received video evidence from the vessel owner verifying the installation of the fuel pump with no signs of leakage. The vessel's crew operated the boat for several hours without incident.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2024 Resolved
Lifejackets were not on station. Relocate all lifejackets to the appropriate storage area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2024 Resolved
Liferings were found with deteriorated retro reflective tape. Replace retro reflective tape on all liferings as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 28 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 May 2024 Resolved
Aft main deck engineroom hatches were not sealed and bolted down. Secure all aft main deck engine room hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2024 Resolved
Port navigation light was inoperable. Repair or replace port navigation light prior to operation beyond dusk or in low visibility.
Action required: 705 - Other - as specified
Resolved 17 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2024 Resolved
Ships newly rebuilt generator was found inoperable. Make repairs to bring generator back into service. Verified generator provides no power or back up to any vital system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 May 2023 Resolved
Masthead light was inoperable. Repair or replace masthead light and associated wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023 Resolved
High water alarm wiring was unprotected in sewage tank space. Secure wiring above float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 August 2022 Resolved
Vessel experienced vibrations in the port shaft and discovered excess water in the bilge. Discover cause and make appropriate repairs to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2022
Resolved 31 August 2022
Resolution: Vessel re-positioned shaft and torqued coupling. Op test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2022 Resolved
Corrosion resistant clip was not installed on the waterlight lanyard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 29 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2022 Resolved
Install protective guard on port engine flywheel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 29 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2021 Resolved
Vessel did not have a current COD reflecting new ownership.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: NVDC issued updated COD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021 Resolved
Lifejackets were not marked with the vessels name. Label lifejackets with vessel name as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Lifejackets were marked with vessels new name.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 June 2021 Resolved
Emergency instructions were not updated to reflect vessels current operating area. Provide updated emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Emregency Instruction placard was updated to reflect the current operating area and crew.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 June 2021 Resolved
The number of passengers allowed on the upper deck was not labeled correctly. The maximum number of passengers allowed on an upper deck must be indicated
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: The upper deck area passenger capacity was labeled IAW stability letter in block lettering at entrance to the upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Lifejacket boxes were labeled IAW vessels safety plan and a accurate count of items inside.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2021 Resolved
Port side engine room battery box was not secured. Ensure battery box is secured to protect against shifting with the roll and pitch of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Battery box was secured to a platform in engine room.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2021 Resolved
Pre engineered Fixed fire fighting system was not installed to shut down engines during automatic discharge of agent.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel owner contacted local fire system company to come out and examine and inspect the fire system main engine shutdowns. The company was able to fix the error, witnessed new test while on site.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 10 June 2021 Resolved
Sewage holding tank fill flange was not sealed. Ensure tank is sealed to not leak or vent into the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2021
Resolution: Sewage holding tank fill flange was sealed.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 10 June 2021 Resolved
Newly assigned crew was not trained in the emergency operations.The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel owner/operator used the time while waiting to clear other deficiencies to conduct proper crew training. Had a discussion with the crew on site regarding emergency instruction to ensure competency.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2021 Resolved
New name and hailing port were not marked on the vessel. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2021
Resolution: Vessel name and hailing port were marked to reflect the information on the COD.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 10 June 2021 Resolved
Copy of MIS report for drug testing was not available. Ensure compliance with chemical testing reporting requirements by providing a copy of the previous year MIS report to the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 June 2021
Resolution: MIS report was printed prior to arrival.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 October 2020 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing for the fixed-gas fire extinguishing systems to the marine inspector. The pre-engineered fixed-gas fire extinguishing had not been annually serviced. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: Fixed-extinguishing system was serviced by J.T.'s Fire Extinguisher Service, Inc.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 October 2020 Resolved
A power-driven vessel underway shall exhibit a masthead light forward. Masthead light was inoperable. 46 CFR 183.420 33 CFR 83.23(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: masthead light was replaced and operable
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020 Resolved
The marine employer shall ensure that all persons directly involved in a serious mearine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with 46 CFR 4.06. Alcohol test strips expired 6/2020. 46 CFR 16.240
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2020
Resolved 4 November 2020
Resolution: new alcohol test strips were purchased with expiration date 09-15-2022.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 April 2019 Resolved
Vessel struck an object while underway. As a result, vessel’s steering gear was compromised. The following requirements must be meet prior to carrying passengers for hire: 1. Provide a copy of the dive report for inspection of any hull damage that may have incurred as a result of the vessel striking a submerged object. 2. Provide Service Tech Report attesting to the repairs and proper operation of the vessel’s rudder, steering system and associated components. 3. Vessel is required to conduct Sea trials in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2019
Resolved 24 April 2019
Resolution: Vessel Owner provided dive report and Service Tech Report attesting to the repairs and proper operation of the vessel’s rudder, steering system and associated components. In addition, satisfactory Sea trials were conducted in the presence of an attending
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2018 Resolved
Provide a copy of a dive report for inspection of any hull damage incurred from vessel running aground.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 10 October 2018
Resolution: Vessel Operator provide this office with a valid copy of a dive report - there were no noticable damage in hull or propulsion system - ALL SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2018 Resolved
Vessel required to conduct Sea Trial in the presence of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2018
Resolved 11 October 2018
Resolution: Vessel Sea Trial were conducted in the presence of an attending Coast Guard Marine Inspector; ALL SAT.
Fire Fighting › Fire Pumps › Pressure
Issued 21 November 2017 Resolved
Fire pump was not able to produce more than 20 PSI at outlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 November 2017 Resolved
Replaced expired battery with approved battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 November 2017 Resolved
Emergency instructions not ship specific.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 7 December 2017
Construction/Loadline › Hull › Bottom Plating
Issued 15 November 2016 Resolved
Provide Repair Plan to address the areas of concern (i.e. pitting) that were identified in way of the bottom hull plating of the vessel’s Starboard and Port mid-sections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2016
Resolution: Verified Repair Plan and the actual repair work performed were IAW with the appropriate NVIC. In addition, verifed proof of Ultrasonic Testing Report that owener provided to this office.

Casualty record · 7

6 August 2005Routine · role: Involved in a Marine Casualty · activity 2474093
4 October 2018Routine · role: Involved in a Marine Casualty · activity 6554765
30 August 2022Routine · role: Involved in a Marine Casualty · activity 7871977
4 August 2023Routine · role: Involved in a Marine Casualty · activity 7762335
23 May 2026Routine · role: Involved in a Marine Casualty · activity 8395121
24 May 2026Routine · role: Involved in a Marine Casualty · activity 8395587
27 May 2026Routine · role: Involved in a Marine Casualty · activity 8395489
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HARBOUR BELLE (2005–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.