Records from 2016 to 2026. Most recent: inspection, 2 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 27.0 ft × 8.5 ft
Registered tonnagegross 32 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEA ISLAND BOATWORKS LLC · MT PLEASANT, SC, UNITED STATES · built 1998
Hull materialWood
PropulsionGasoline Outboard
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 9 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
2 April 2026
Internal Structural Exam · Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8340906
3 March 2025
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8087368
4 December 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8043218
30 April 2024
Special · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7903859
27 March 2024
Deficiency Check · Examination of Repairs · Annual Inspection · Equivalency · Administrative Inspection · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7883014
18 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7670889
2 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7603230
7 April 2022
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426291
16 February 2022
Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397504
15 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7154924
6 January 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120300
6 April 2020
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933075
29 April 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6673177
30 January 2019
Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6618648
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580554
21 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6415740
16 November 2017
Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308106
1 May 2017
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6131251
24 January 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6076407
20 April 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5858041
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 March 2024
Resolved
The vessel requires bilge high level alarms in all spaces with hull valves. The two aft compartments do not have high water alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2024
Resolved
All submersible electrical bilge pumps must be permanently mounted and operational. Both auto float lever for the starboard hull pumps are not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024
Resolved
All remote fuel valves stations need to be properly labeled. Both valve locations need to be labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 March 2024
Resolved
All radio equipment must be serviced by a licensed FCC Technician at the appropriate intervals. The Safety Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2018
Resolved
The vessel is required to meet the strucural standards for a small passenger vessel (T). The vessel has a stringer on the STBD side that has a fracture at the attachement to the hull. The vessel owner is required to conduct repairs to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 15 June 2018
Resolution: corrected, all SAT.
Construction/Loadline › Hull › Side Shell
Issued 12 December 2017
Resolved
Delamination was found on top of and below rub rail locted on port bow. Sand out and make repairs as needed. This is located 04 feet above water line.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 21 February 2018
Resolution: Damage repaired to the inspectors satisfaction.
Lifesaving › Hand Flares › Quantity
Issued 1 May 2017
Resolved
Provide 4 Red Flares or Orange Smoke.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 1 May 2017
Resolution: Witnessed
Engineering › Bilge Water Management System › Hose
Issued 1 May 2017
Resolved
Portable bilge hose need to connect correctly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 1 May 2017
Resolution: Bought a new hose.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 May 2017
Resolved
Need to meet the 2 hour window for Alcohol.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: ordered new ones.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2016
Resolved
Renew reflective tape on Life Ring Buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 April 2016
Resolved
Renew Reflective tape on 08 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 20 April 2016
Resolved
High water alarm Audible and Visual indicators
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016