MAURY USCG vessel records
← All vessels

ISLAND TIME

ISLAND TIME is a 1998 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2026, along with 12 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 April 2026.

Built
1998
Last inspected
2 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM7010
472962
Flag
UNITED STATES
Maury page id
psix-472962

Documentation record

Registered dimensions (L × B × D)50.0 ft × 27.0 ft × 8.5 ft
Registered tonnagegross 32 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEA ISLAND BOATWORKS LLC · MT PLEASANT, SC, UNITED STATES · built 1998
Hull materialWood
PropulsionGasoline Outboard
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 9 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

2 April 2026 Internal Structural Exam · Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8340906
3 March 2025 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8087368
4 December 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8043218
30 April 2024 Special · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7903859
27 March 2024 Deficiency Check · Examination of Repairs · Annual Inspection · Equivalency · Administrative Inspection · Special Consideration
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7883014
18 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7670889
2 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7603230
7 April 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426291
16 February 2022 Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397504
15 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7154924
6 January 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120300
6 April 2020 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933075
29 April 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6673177
30 January 2019 Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6618648
14 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580554
21 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6415740
16 November 2017 Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308106
1 May 2017 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6131251
24 January 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6076407
20 April 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5858041

Deficiency record · 12

04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 March 2024 Resolved
The vessel requires bilge high level alarms in all spaces with hull valves. The two aft compartments do not have high water alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2024 Resolved
All submersible electrical bilge pumps must be permanently mounted and operational. Both auto float lever for the starboard hull pumps are not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2024 Resolved
All remote fuel valves stations need to be properly labeled. Both valve locations need to be labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 March 2024 Resolved
All radio equipment must be serviced by a licensed FCC Technician at the appropriate intervals. The Safety Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 8 April 2024
Resolution: Corrected.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2018 Resolved
The vessel is required to meet the strucural standards for a small passenger vessel (T). The vessel has a stringer on the STBD side that has a fracture at the attachement to the hull. The vessel owner is required to conduct repairs to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 15 June 2018
Resolution: corrected, all SAT.
Construction/Loadline › Hull › Side Shell
Issued 12 December 2017 Resolved
Delamination was found on top of and below rub rail locted on port bow. Sand out and make repairs as needed. This is located 04 feet above water line.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 21 February 2018
Resolution: Damage repaired to the inspectors satisfaction.
Lifesaving › Hand Flares › Quantity
Issued 1 May 2017 Resolved
Provide 4 Red Flares or Orange Smoke.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 1 May 2017
Resolution: Witnessed
Engineering › Bilge Water Management System › Hose
Issued 1 May 2017 Resolved
Portable bilge hose need to connect correctly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 1 May 2017
Resolution: Bought a new hose.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 May 2017 Resolved
Need to meet the 2 hour window for Alcohol.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: ordered new ones.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2016 Resolved
Renew reflective tape on Life Ring Buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 April 2016 Resolved
Renew Reflective tape on 08 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 20 April 2016 Resolved
High water alarm Audible and Visual indicators
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 26 April 2016

Ownership record