DELTA THUNDER is a 1998 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 1998, most recently in December 2011, along with 6 deficiencies.
Records from 1998 to 2011. Most recent: inspection, 2 December 2011.
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for DELTA THUNDER (ON 1065173), retrieved 18 September 2026. mauryrecords.com/v/psix-472967.html
Documentation record
Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 5.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton 21 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF8553MMSI 367496110 · active · compulsorily equipped · granted 7 May 2021, expires 21 June 2031
WDA4479MMSI 366809880 · cancelled · compulsorily equipped · granted 5 April 2011, cancelled 9 August 2011
WCY7465MMSI not assigned · expired · compulsorily equipped · granted 26 October 1998, cancelled 27 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
2 December 2011Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4201606
23 March 2009Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438506
17 April 2008Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3186496
23 April 2007Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2913568
26 April 2006COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2633690
20 January 2006Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569872
20 April 2005Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2347289
Due 10 May 2007
Resolved 23 April 2007
Resolution: Remote Shut off labeled.
Personnel › Training › First Aid/CPR
Issued 26 April 2006Resolved
Provide proof of First Aid training for 50% of the crew (1person).
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 17 May 2006
Construction/Loadline › Hull
Issued 4 May 2004Resolved
Gouge and weld stbd strut 100% inside and out as marked prior to returning to service. LEGACY COMPONENT DESC: Strut/Cross Tie
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2004
Resolved 4 May 2004
Resolution: Vsl was hauled out at local shipyard, strut had cracked weld and small pinhole. Repaired descrepancies and water tested satisfactory.
Engineering › Bilge Water Management System
Issued 4 May 2004Resolved
Prove proper operation of visual bilge alarm indicator on steering console in pilothouse. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2004
Resolved 7 May 2004
Resolution: Received invoice of new light bulb for visual indication.
Lifesaving › Lifebuoys
Issued 4 May 2004Resolved
Prove installation of new batteries in both float lights. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2004
Resolved 7 May 2004
Resolution: Received invoice of new batteries purchased.
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 24 April 2002
Resolution: Replaced hose.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National