MAURY USCG vessel records
← All vessels

CAPTAIN CAL II

CAPTAIN CAL II is a 1972 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in April 2026, along with 74 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 14 April 2026.

Built
1972
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN2774
Flag
UNITED STATES
Maury page id
psix-47297

Documentation record

Registered dimensions (L × B × D)77.2 ft × 19.2 ft × 5.0 ft
Registered tonnagegross 65 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM I HAMMARSTROM · WARETOWN, NJ, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 20 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

14 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8349732
28 May 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8146040
17 April 2025 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8112726
13 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8092045
18 April 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7987612
27 April 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7677329
8 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7647823
8 July 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7500701
28 January 2022 COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7387270
18 January 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7381642
19 August 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7291102
14 June 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7225293
15 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7156303
28 January 2021 Deficiency Check · Appeal
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7132576
10 December 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7110263
3 December 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6866079
19 March 2019 Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6643295
27 November 2018 Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6580293
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505986
31 January 2018 Plan Review "T" Boat · Examination of Repairs · Construction Oversight · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6347186
14 November 2017 DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6304016
21 March 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106675
8 December 2016 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6053920
16 May 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5878283

Deficiency record · 74

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2026 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns, for each fixed gas fire extinguishing system and detection system to determine that the system is in operating condition. Vessel operator was unaware of functions of fixed Fire Boy system. Vessel operator was also unaware on how to operationally test system nor comfortable with the process. Conduct operational test of system in accordance with manufactures manual with certified third party and USCG to ensure full operation of system. 46 CFR 176.810 (a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2026
Resolution: MI attended vessel with Associated Fire to test all functions of system with O/O. All sat. Training provided to O/O and mates.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them water tight. Port and starboard longitudinal beams running through watertight bulkheads have gaps between bulkheads and beams. Seal all identified gaps and make watertight. 46 CFR 171.114(a)(2)(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 16 April 2026
Resolution: MI observed all sections previous in concern sealed and made water tight. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 April 2026 Resolved
Protective gratings shall be provided at such locations where persons gear might come in contact with the exhaust pipe. Insulation lagging on starboard main engine exhaust has worn and exposed exhaust piping is visible. Replace insulation to cover all exposed exhaust piping. 46 CFR 182.15-20(g) (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 16 April 2026
Resolution: MI observed all sections of insulation / lagging added where missing and or worn. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 April 2026 Resolved
Where required.(a) All vessels required to be provided with a power-driven fire pump shall also be provided with a fire main system Including fire main, hydrants, hose and nozzles. Starboard side fire pump could not produce adequate pressure when initially tested. Operator replaced drive belt during course of exam. MI retested fire pump and found satisfactory. 46 CFR 181.15-1 (OLD T)
Action required: 10 - Deficiency Rectified
Due 15 April 2026
Resolved 14 April 2026
Resolution: o/o replaced belt on pump to engine and tested hose pressure in presence of MI
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2025 Resolved
Fire hose shall be 1 1/2 inches in diameter and 50 feet in length. During testing, port side hose ruptured and was cut down by three feet to stop leaking. Replace hose with lined commercial fire hose to satisfaction of MI. 46 CFR 181.15-10(c) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Fire hose was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 April 2025 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Multiple strainers found broken/clogged. Repair or replace to satisfaction of MI. 46 CFR 182.25-5(b) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Strainer was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2025 Resolved
Flexible hose shall be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. The hose cover shall be adjudged self-extinguishing per ASTM D1692, and the hose assembly be capable of withstanding free burning gasoline for 2 minutes. Fuel hoses to and from fuel filter on generator are chaffed into the wire braiding. Replace with approved hoses to satisfaction of MI. 46 CFR 182-20-40(a)(ii)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 28 May 2025
Resolution: Hoses were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2025 Resolved
The Marine Inspector shall examine the following items to determine that they are in proper operating condition. Hydraulic hose in forepeak is corroded to wire braid. Replace to satisfaction of MI. 46 CFR 182.40-1(a)(4) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Hydraulic hose was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 April 2025 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Starboard engine alternator is missing protective guard. Install guard to satisfaction of MI. 46 CFR 177.35-15(a) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Guard was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2025 Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deckhouse sides, and at ladders and hatches where passengers or crew might have normal access. Forward ladder from main deck to upper deck is loose. Repair to satisfaction of MI. 46 CFR 177.35-5(a) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Forward ladder was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2025 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Port side chain used in lieu of rail is not affixed properly. Repair to satisfaction of MI. 46 CFR 177.35-1(a) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Chain was satisfactorily attached.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 April 2025 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shutoffs were not marked. Additionally, tool used to open shutoff access were not in the vicinity of the openings. Mark port and starboard shutoffs and place tool near shutoff openings to satisfaction of MI. 46 CFR 185.30-20 (a)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: Shutoffs marked and tool was relocated.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 17 April 2025 Resolved
The maximum number of passengers allowed on the upper decks must be indicated by a durable marking of numbers and letters at least one inch in height at the entranceway to each such deck. Upper deck pax marking is not at entranceway. Relocate marking to entranceway to upper deck to satisfaction of MI. 46 CFR 185.30-3(e)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 15 May 2025
Resolution: New marking installed near entranceway to upper deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2025 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Port and starboard main engine flexible hoses, including cooling, oil, and fuel hoses, show signs of degradation. Replace hoses with approved types to the satisfaction of MI. 46 CFR 182.01-5(a)OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 28 May 2025
Resolution: Hoses were replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 February 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down...all engines that draw intake air from within the protected space. While testing the equipment, the pre-engineered fixed fire system did not shut down the main engines or the generator in the engine room. Additionally, the pressure gauge that determines the amount of agent in the cylinder indicated that there was abnormality with the volume of the product in the cylinder. Service pre-engineered system, prove proper operation, and provide servicing report for fixed and portable fire fighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Remotely witnessed sat operation of pre-engineered ff using FaceTime.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2022 Resolved
...[O]n a vessel of more than 19.8 meters (65 feet) in length, each hose must: Be lined commercial fire hose...When testing the fire hose, a hole was detected. Replace fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 February 2022 Resolved
Each paddle must be...lashed to the life float to which it belongs...Paddles were not lashed. Lash paddles in the lifefloats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 February 2022 Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Lifelines for lifefloat were found ziptied together. Replace zip ties for hand lines with breakable ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 February 2022 Resolved
Each item of survival craft equipment must...be secured by lashings, stored in lockers, compartments, brackets, or have equivalent mounting or storage arrangements that do not: Interfere with launching, recovery, or rescue operations...The water light lines for the life floats were not organized. Properly stow water light lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Adult and child life jackets were not separated. Stow and mark child life jackets in a separate location from adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2022 Resolved
The regulations contained in this part are substantially in accord with, and in general are based upon established codes and recognized marine standards and practices...A list of the publications follows: Standard for Marine Type Electric Lighting Fixtures, Subject 595, published by Underwriters' Laboratories, Inc....One lighting fixture in the lazarette was missing the globe. Replace globe on the lighting fixture in lazarette. 46 CFR 183.01-15(b)(4) "OLD T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2022 Resolved
Each ungrounded conductor of circuit supplying lights, motors or appliances shall be equipped with a circuit breaker or switch and fuses at the point of attachment to the power source. Fuse plugs were missing in the electrical panel at the bottom of the engine room ladder. Replace missing fuse plugs in electrical panel at the bottom of the engine room ladder. 46 CFR 183.05-15(c) "OLD T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 24 February 2022
Resolution: Via photo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 January 2022 Resolved
COI has expired and is no longer valid. Contact Sector Delaware Bay to schedule COI Renewal Inspection. COI Renewal inspection must be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2022
Resolution: USCG Marine Inspector attended the vsl on 03FEB2022 and issued Temporary COI. Deficiency rectified.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 July 2021 Resolved
Vessel's EPIRB was not registered. Vessel restricted to 03 NM until proof of registration received.
Action required: 705 - Other - as specified
Due 1 July 2021
Resolved 3 July 2021
Resolution: Owner purchased new EPIRB and provided proof of registration.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 July 2021 Resolved
Provide EPIRB registration, FCC station license, radio telephony certificate, update MMSI in VHF, update emergency broadcast placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 19 August 2021
Resolution: Administratively cleared outstanding CG-835 Item 1 issued 01JUL2021 to "Provide EPIRB registration, FCC station license, radio telephony certificate, update MMSI in VHF, update emergency broadcast placard." Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 March 2021 Resolved
Replace rotting wormshoe in forward section of keel. Repair and epoxy superficial wood rot where the keel meets the hull.46 CFR 176.802.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 25 March 2021
Resolution: O/O replaced rotted wormshoe, photo evidence.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2021 Resolved
Wire run that penetrates the bulkhead in the #3 space needs to be resealed. 46 CFR 176.806.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 March 2021 Resolved
Remove minor delignification in engine room and re epoxy to prevent further rotting. 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2020 Resolved
NAVIGATION LIGHTS: Port and Starboard Navigation Lights on side of wheelhouse were missing the bulb mounting sockets causing improper focal plane for nav lights per conversation with manufacturer. Repair/Replace with appropriate navigation lights/sockets. 33 CFR 83.20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2020 Resolved
STARBOARD MDE TURBO: Slight oil leak noted at seal for turbocharger on the starboard main engine. Investigate, clean, and properly repair. 46 CFR 182.425
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2020 Resolved
ELECTRICAL EXTENSION POWER-STRIP - GALLEY: Remove power-strip from the galley drain. 46 CFR "Old T" 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 28 January 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2020 Resolved
FREEZER POWER CORD - GALLEY: Repair/Replace power-cord plug for the galley freezer. 46 CFR "Old T" 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 28 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 December 2020 Resolved
NIGHT FISHING LIGHTS, WIRING - UPPER DECK: Either remove all flood lights and associated wiring from the upper deck for historic night fishing, or repair and replace installation to comply with marine installation.46 CFR "Old T" 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 24 February 2022
Resolution: Cleared via emailed photo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2020 Resolved
110V ELECTRICAL PANEL - WHEELHOUSE: Install blank cover in 120V electrical panel in wheelhouse to prevent/protect from accidental contact. 46 CFR "Old T" 183.10-20(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 December 2020 Resolved
DRAFT MARKS: At next dry dock scheduled for March 2021, affix permanent draft marks to vessel. 46 CFR 185.602 705c - Completed at Mar 2021 DD/ISE.
Action required: 705 - Other - as specified
Due 17 April 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 December 2020 Resolved
LIFEFLOAT: Remove all zip ties from life float grab lines and netting. 46 CFR 180.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
Resolution: Verified life raft had zip ties removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2020 Resolved
POLY-LINE ON SOME LIFE FLOATS & LIFE RINGS: Replace all yellow poly-lines affixed to life floats and life rings with UV marine black poly-line. Corrected on the spot. 46 CFR 180.200
Action required: 10 - Deficiency Rectified
Resolved 10 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 December 2020 Resolved
BILGE PIPING: Multiple hoses were on bilge lines in the #2 and #3 spaces. Replace all rubber hose and hose clamped pipe connection on copper bilge piping with properly installed copper couplings or unions OR Install valves at watertight bulkhead in accordance with 46 CFR "Old T" 40-1(a)(ii). 46 CFR "Old T" 182.40-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 3 March 2021
Resolution: Reconsideration granted on this def. Owner notified through email.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 10 December 2020 Resolved
WINCH HYDRAULIC LINE FOR WINCH - ANCHOR LOCKER: Provide for chafing protection. 46 CFR "Old T" 176.25-40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 28 January 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2020 Resolved
GENERATOR SWITCH BOARD: Re-secure switchboard cover for generator in main engine space. Install blank in open wire hole in side of switchboard. 46 CFR "Old T" 183.10-20(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
Resolution: Verified resecured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2020 Resolved
OUTLETS: Multiple Electric outlets inside main deck accommodation area were found to have open grounds or the hot and neutral wires were reversed. Conduct testing on all outlets and make repairs as necessary. 46 CFR "Old T" 183.10-20(o)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 28 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2020 Resolved
FIRE EXTINGUISHER - GALLEY: Perform housekeeping around galley fire extinguisher. Corrected on the spot. 46 CFR 81.500
Action required: 10 - Deficiency Rectified
Resolved 10 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2020 Resolved
MAIN ENG EXHAUST, TEMP PROTECT: Address the high-temp of surrounding wood in way of main engine exhaust. (The wood surrounding the exhaust from the main engines thru the overhead is being damaged from excessive heat. The wood temp was measured at 190 degrees and insulation at 300 degrees; prolonged impingement can lead to degradation of the wood and increase chance for fire. Installation of add'l insulation is required. 46 CFR "Old T" 182.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 3 February 2022
Resolution: A USCG Marine Inspector went to the vessel on 03FEB2022 and confirmed that the deficiency was rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 December 2019 Resolved
Vessel required six red hand and six orange smoke distress signals; all smoke signals expired. Replaced prior to operation outside inlet. 46 CFR 180. 68 (a)
Action required: 705 - Other - as specified
Due 22 January 2020
Resolved 22 January 2020
Resolution: Flares purchased.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 December 2019 Resolved
VHFDSC does not have MMSI or location. Program MMSI number and provide GPS location information to VHFDSC radio. 46 CFR 184. 502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 17 April 2020
Resolution: Received proof of VHF being interfaced with GPS and programmed with MMSI in the form of an invoice.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 December 2019 Resolved
Monthly testing of the EPIRB is not being conducted. Conduct monthly test and login. USCG witnessed test is satisfactory for December 2019 test. 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 22 January 2020
Resolution: Vessel will be logging EPIRB tests.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 December 2019 Resolved
Two hatch covers are not secured to the vessel by securing device. Secure hatch covers to vessel. 46 CFR 171.124 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 22 January 2020
Resolution: Chains added to hatch covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 November 2018 Resolved
Ammeter for generator is not working. Prove proper operation of gauge. Place covers over openings in generator panel. 46 CFR "Old T" 183.10-5(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 9 July 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 November 2018 Resolved
Bilge alarm light for #5 on panel displays light whenever another space alarms. Fix alarm panel so each alarm only gives visible indication for appropriate space. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2018 Resolved
Place bonding wire on flexible fuel fill lines. 46 CFR "Old T" 182.20-30(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2018
Resolved 20 March 2019
Resolution: Owner istalled bonding wires to both fuel tank flexible fill lines.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: Incorrect NAME.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Accommodation/Occupational Safety › Heating › Radiator
Issued 14 November 2017 Resolved
MAB01: Space heater in engine room: remove due to fire hazard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Owner will remove prior to going underway.
Lifesaving › Lifefloat › Serviceable
Issued 14 November 2017 Resolved
MAB02: Repair hole and relabel 10-person lifefloat. Persons limited to 50 until cleared by CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Repairs were made to Life Float and verified in person.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 November 2017 Resolved
MAB03: Sewage overboard discharge is not properly secured: secure by either ziptie, lock, or remove handle of discharge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Valve handle was secured to toilet.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 November 2017 Resolved
MAB04: Containers for lifejackets labeled w/ incorrect #: relabel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Proper labeling amount was posted on container.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 November 2017 Resolved
MAB05: Provide updated Coast Pilot and tide tables for operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2017
Resolved 21 November 2017
Resolution: Operator provided updated Coast Pilot.
Engineering › Bilge Water Management System › Pump
Issued 8 December 2016 Resolved
Fixed bilge system cannot pump out spaces 2 and 3. Prove proper operation to Coast Guard Marine Inspector (CGMI) 46CFR182.25-5 Prior to carrying passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2016
Resolved 3 January 2017
Lifesaving › Lifebuoys › Serviceable
Issued 8 December 2016 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 3 January 2017
Documentation › Logs/Records › Logbook (official)
Issued 8 December 2016 Resolved
Fire and man overboard drills not logged monthly. Drills must be conducted and logged. 46CFR185.520(d) Corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 December 2016 Resolved
Vessel is missing 04 child lifejackets to satisfaction of CGMI. 46CFR176.105. Prior to carrying more than 8 children.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2017
Engineering › Bilge Water Management System › Valve
Issued 8 December 2016 Resolved
Automatic bilge pumps in engine room and 5th compartment have check valves installed. Valves must be manual shut off valves. 46CFR182.50(e)(7). 8JAN17
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Fire Fighting › Fire Hoses › Condition
Issued 8 December 2016 Resolved
STBD firehose has splice in it. Shorten hose to splice. 8JAN17
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Navigation › Piloting/Steering › Marine Charts
Issued 8 December 2016 Resolved
Charts and Coast Pilot are 2006 edition. Provide updated charts and Coast Pilot for operating area. 46CFR184.420. 8JAN17
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Communications › Radio Communications › EPIRB
Issued 8 December 2016 Resolved
EPIRB test not logged monthly. Must test and log EPIRB monthly. 46CFR185.728. Corrected on the spot.
Condition: Improper Installation
Due 16 December 2016
Resolved 8 December 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2016 Resolved
Multiple items in first aid kit, including burn cream, ammonia inhalants, aspirin are expired. Replace all expired items in kit to satisfaction of CGMI. 8JAN17
Condition: Improper/Lack of Maintenance
Due 8 January 2017
Resolved 3 January 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 December 2016 Resolved
Provide appropriate life jacket donning placard. 8JAN17
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Construction/Loadline › Penetrations › Gasket
Issued 8 December 2016 Resolved
Manhole on aft deck fwd of aft door is corroded and cannot be dogged. Repair/replace to satisfaction of CGMI. 8JAN17
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Lifesaving › Lifefloat › Float Free
Issued 8 December 2016 Resolved
Make lifefloat painter and weak link a float-free arrangement to satisfaction of CGMI. 15DEC16
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 3 January 2017
Engineering › Bilge Water Management System › Vent
Issued 8 December 2016 Resolved
Bilge system has flex hose, with only one hose clamp on each side. Install two hose clamps per side. 8JAN17
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2016 Resolved
Make visual and audible indicators of bilge high level in #5 & #6 compartments indicate/alarm as labeled at operating station. (#5 visual indicator indicator lights up when all other spaces' float is raised and #5 & #6 audible alarms do not work.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Verified all indicators (audible/visual) are working correctly.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 May 2016 Resolved
Install automatic shutdown for generator upon activation of pre-engineered fixed fire system in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Witnessed shutdown of generator upon simulation of fixed system activation.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 16 May 2016 Resolved
Remove flexible hose penetrating watertight bulkheads and use proper penetrations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 3 August 2016
Resolution: OCMI granted special consideration to allow installation as is. When hose needs to be replaced, the installation must meet the regulations.
Stability › Watertight Integrity › General
Issued 16 May 2016 Resolved
Make #5 compartment hatch watertight.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: O/O provided hatch cover, but it does not have the ability the be dogged down. The hatch is located in a relatively protected area and the O/O will replace the hatch at the next drydock
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 May 2016 Resolved
Crew shall conduct drills underway.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Witnessed satisfactory underway drills.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.